• 제목/요약/키워드: 2D magnetic field

검색결과 517건 처리시간 0.026초

Numerical Study of Inflation of a Dipolar Magnetic Field by Injecting Plasma with Different Beta

  • Kajimura, Yoshihiro;Funaki, Ikkoh;Shinohara, Iku;Usui, Hideyuki;Nakashima, Hideki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.553-556
    • /
    • 2008
  • A Magneto Plasma Sail(MPS) produces propulsive force by the interaction between the solar wind and an artificial magnetic field inflated by injecting plasma. Using a 2D hybrid PIC code, we evaluate the inflation of magnetic field when Argon(Ar) plasma with different ${\beta}_{in}$ including the value less than one is injected into the dipolar magnetic field generated by a superconducting coil. It is found that the magnetic field can be inflated by injecting plasma within an angle of $30^{\circ}$ in the polar direction and the magnetic field decays in the polar direction according to $B{\propto}r^{-2.4}$ after the plasma(${\beta}_{in}$=0.1) is injected.

  • PDF

A New Method to Estimate the Induced Electric Field in the Human Child Exposed to a 100 kHz-10 MHz Magnetic Field Using Body Size Parameters

  • Park, Young-Min;Song, Hye-Jin;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.174-180
    • /
    • 2014
  • In this paper, a new and simple method is proposed to quickly estimate the induced electric field in the human child exposed to a 100 kHz-10 MHz magnetic field, for the sake of electromagnetic field (EMF) safety assessment. The quasi-static finite-difference time-domain (FDTD) method is used to calculate the induced electric fields in high resolution 3D human child models with various body size parameters, in order to derive the correction factor for the estimation equation. The calculations are repeated for various frequencies and incident angles of the magnetic field. Based on these calculation results, a new and simple estimation equation for the 99th percentile value of the body electric field is derived that depends on the body size parameters, and the incident magnetic field. The estimation errors were equal to or less than 5.1%, for all cases considered.

수평 자기쌍극자 송신원을 이용한 2.5차원 전자탐사 모델링 (2.5 Dimensional EM Modeling considering Horizontal Magnetic Dipole Source)

  • 권형석;송윤호;손정술;서정희
    • 지구물리와물리탐사
    • /
    • 제5권2호
    • /
    • pp.84-92
    • /
    • 2002
  • 이 연구에서는 최근에 개발되어 적용성에 대한 시험이 진행되고 있는 $1\;kHz\~1\;MHz$ 주파수대역의 수평 자기쌍극자를 송신원으로 하여 전기장과 자기장을 측정하는 탐사법의 모델링 알고리듬을 개발하고자 하였다. 이를 위해 공간주파수 영역에서 수평 자기쌍극자를 송신원으로 하는 이차장 Maxwell 방정식을 구성하고 유한요소법을 이용하여 2.5차원 모델링 알고리듬을 구현하였다. 또한, 검증된 층서구조 반응결과와 비교하여 그 정확도를 검증하였다. 개발된 알고리듬을 이용하여 균질 반무한공간 내에 전도성 및 비전도성 고립이상체가 존재하는 2차원 모형에 대한 전기장, 자기장과 임피던스를 계산하였다. 계산된 전기장, 자기장과 임피던스의 거동에 대한 고찰 결과 고립이상체와 같이 2차원 구조에서 전기장과 임피던스가 자기장에 비해 이상체의 탐지에 효과적임을 보였다. 특히, 전기장을 자기장으로 나눈 값인 임피던스는 전기장의 공간 분해능을 가지면서 보다 안정된 결과를 보여 주었다. 따라서 자기장만을 측정하는 기존의 전자탐사법에 비해 전기장과 자기장을 모두 측정하는 탐사법이 천부에 존재하는 이상체의 탐지에 보다 효과적임을 알 수 있었다.

강자성 함정 선체 및 내부 장비에 의한 수중 정자기장 신호 예측 (Prediction for Underwater Static Magnetic Field Signature Generated by Hull and Internal Structure for Ferromagnetic Ship)

  • 양창섭;정현주;주혜선;전재진
    • 한국자기학회지
    • /
    • 제21권5호
    • /
    • pp.167-173
    • /
    • 2011
  • 함정에 의한 수중 정자기장 신호는 수중 방사소음 신호에 비해 상대적으로 거리에 따라 급격히 감소되는 특성을 가지지만 근거리에서 정확한 표적 탐지가 가능하므로 감응 기뢰 체계에서 기폭 신호를 제공하는 신호원으로 널리 사용되고 있다. 본 논문에서는 상용 전자기 해석 도구를 활용하여 함정 선체, 내부 구조물 및 주요 탑재장비들에 의한 수중 정자기장 신호 특성 예측 결과에 대해 상세히 기술하였으며, 추가로 대상 함정에 소자코일을 배치하여 소자 효과도 분석을 수행하였다.

Indirect Fault Detection Method for an Onboard Degaussing Coil System Exploiting Underwater Magnetic Signals

  • Jeung, Giwoo;Choi, Nak-Sun;Yang, Chang-Seob;Chung, Hyun-Ju;Kim, Dong-Hun
    • Journal of Magnetics
    • /
    • 제19권1호
    • /
    • pp.72-77
    • /
    • 2014
  • This paper proposes an indirect fault detection method for an onboard degaussing coil system, installed to reduce the underwater magnetic field from the ferromagnetic hull. The method utilizes underwater field signals measured at specific magnetic treatment facilities instead of using time-consuming numerical field solutions in a three-dimensional space. An equivalent magnetic charge model combined with a material sensitivity formula is adopted to predict fault coil locations. The purpose of the proposed method is to yield reliable data on the location and type of a coil breakdown even without information on individual degaussing coils, such as dimension, location and number of turns. Under several fault conditions, the method is tested with a model ship equipped with 20 degaussing coils.

등가 자기저항 2D와 3D 유한요소해석에 의한 LHSM의 자계 특성 비교 (Comparison of Magnetic Field Using Equivalent Reluctance 2D and 3D FEA for Linear Homopolar Synchronous Motor)

  • 장석명;정상섭;양현섭;류동완;윤인기;성소영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.3-5
    • /
    • 1999
  • The 4-pole LHSM was composed of the figure-of-eight shaped 3-phase armature windings, DC field windings, and the segmented secondary with the transverse bar track. Three dimensional model of LHSM provided the equivalent reluctance and PM model for 2D FEA. From these 2D FEA models, when the motor was fed by DC and 3-phase currents, the magnetic field were calculated and compared with the results of 3D FEA.

  • PDF

Design and Implementation of Portable NMR Probe Magnet

  • Junxia, Gao;Yiming, Zhang;Jiashen, Tian
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.14-22
    • /
    • 2017
  • The NMR's probe consists of the static magnetic field generator (magnetic source) and the RF coil. It is very strict for the homogeneity of the static magnetic field intensity of the magnetic source, so the cost of the magnetic source is more expensive in the entire nuclear magnetic resonance instrument. The magnetic source generally consists of electromagnet, permanent magnet and superconducting magnet. The permanent magnet basically needs not to spend on operation and maintenance and its cost of manufacture is much cheaper than the superconducting magnet. Therefore, the permanent magnet may be the only choice for the static magnetic field device if we want to use the magnetic resonance instrument as an analyzer for production by reducing price. A new probe magnet was developed on the basis of the permanent magnet ring in this paper to provide a technological way for reducing the manufacturing cost, weight and volume of the existing nuclear magnetic resonance instrument (including MRI) probe.

6 MV 광자선의 선량 상승 영역에 대한 자기장 영향 (Effect of Transverse Magnetic Field on Build-up Region of 6 MV Photon Beam)

  • 신성수;최원식;안우상;곽정원
    • 한국자기학회지
    • /
    • 제27권1호
    • /
    • pp.18-22
    • /
    • 2017
  • 저 강도 자기장을 이용하여 기존의 6 MV 광자선에 대한 선량 상승보다 향상된 선량 변조 방법을 제안하고 이를 실험적으로 선량 효과를 확인하고자 하였다. 0.5 T (Tesla) 강도를 지니는 두 개의 네오디뮴 영구 자석을 광자선에 수직 방향으로 자기장을 인가하였다. 자석과 자석 간의 거리(MMD)와 자석과 물 표면 간의 거리(MSD)에 따라 자기장을 인가한 경우와 인가하지 않은 경우에서의 선량 상승 영역의 선량 변화를 측정하였다. 자석과 자석 간의 거리가 6 cm이고 자석과 물 표면 간의 거리가 2.5 cm 조건에서 기존 6 MV 광자선의 선량 상승 곡선과 비교하여 $D_{0mm}$, $D_{2mm}$, $D_{5mm}$, $D_{10mm}$ 가 각각 6.8 %, 14.6 %, 6.9 %, 2.1 %의 향상된 선량 효과를 보였다. 본 연구를 통해 피부와 매우 인접한 곳에 위치해 있는 표적 체적을 방사선 치료할 경우, 인체 외부에 바로 자기장을 인가하면서 기존 광자선보다 향상된 선량 상승을 기대할 수 있어 임상 적용 가능성이 높을 것으로 기대된다.

Design of New Type Universal Motor Using Soft Magnetic Composites

  • Kim Byung-Taek
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.211-215
    • /
    • 2006
  • This paper presents a new structure for the universal motor using soft magnetic composite (SMC). The stator for this new type of motor is made by combination of the SMC pole and the silicon steel yoke. The shape of the 3D SMC pole is designed to minimize ohmic loss and amount of stator coil. To design the pole shape, the 3D analysis in the design procedure is replaced with an equivalent 2D analysis. Finally, the optimal shape is analyzed by 3D FEM and the performance is discussed.

Electron Holography of Advanced Nanomaterials

  • Shindo, D.;Park, H.S.;Kim, J.J.;Oikawa, T.;Tomita, T.
    • Applied Microscopy
    • /
    • 제36권spc1호
    • /
    • pp.63-69
    • /
    • 2006
  • By utilizing a field emission gun and a biprism installed on a transmission electron microscope (TEM), electron holography is extensively carried out to visualize the electric and magnetic fields of nanomaterials. In the electric field analysis, the distribution of electric potential in a sharp tip made of W coated with $ZrO_2$ is visualized by applying the voltage to the tip. Denser contour lines due to the electric potential are observed with an increase in the bias voltage. In the magnetic field analysis by producing the strong magnetic field with a sharp magnetic needle made of a permanent magnet, the in situ experiment is carried out to investigate the magnetization of hard magnetic materials. The results of these experiments clearly demonstrate that electron holography is a promising advanced transmission electron microscopy technique to characterize the electric and magnetic properties of nanomaterials.