• 제목/요약/키워드: 2D gradient mapping method

검색결과 5건 처리시간 0.02초

2D Correlation Analysis of Spin-Coated Films of Biodegradable P(HB-co-HHx)/PEG Blends

  • Kim, Min-Kyung;Ryu, Soo-Ryeon;Noda, Isao;Jung, Young-Mee
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권11호
    • /
    • pp.4005-4010
    • /
    • 2011
  • We investigated thermal behavior of spin-coated films of P(HB-co-HHx)/PEG blends by using infraredreflection absorption (IRRAS) spectroscopy and 2D correlation spectroscopy. Based on 2D IRRAS correlation spectra, we could determine the sequence of spectral intensity changes with increasing temperature that PEG band changes first and then a band for crystalline component of P(HB-co-HHx) changes before a band for amorphous component. The intensities of bands for PEG and amorphous P(HB-co-HHx) were changed greatly as PEG weigh % of P(HB-co-HHx)/PEG blends increased. Transition temperatures of P(HB-co-HHx)/PEG blends were successfully determined by 2D gradient mapping method. The transition temperature of spincoated films of 98/2 and 90/10 P(HB-co-HHx)/PEG blends and 80/20 P(HB-co-HHx)/PEG blend determined by 2D gradient map are, respectively, about 137.5 and $132.5^{\circ}C$. Furthermore, P(HB-co-HHx)/PEG blends show an additional transition temperature that have been interpreted in terms of different lamellar thicknesses in spin coated films.

Generating Motion- and Distortion-Free Local Field Map Using 3D Ultrashort TE MRI: Comparison with T2* Mapping

  • Jeong, Kyle;Thapa, Bijaya;Han, Bong-Soo;Kim, Daehong;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권4호
    • /
    • pp.328-340
    • /
    • 2019
  • Purpose: To generate phase images with free of motion-induced artifact and susceptibility-induced distortion using 3D radial ultrashort TE (UTE) MRI. Materials and Methods: The field map was theoretically derived by solving Laplace's equation with appropriate boundary conditions, and used to simulate the image distortion in conventional spin-warp MRI. Manufacturer's 3D radial imaging sequence was modified to acquire maximum number of radial spokes in a given time, by removing the spoiler gradient and sampling during both rampup and rampdown gradient. Spoke direction randomly jumps so that a readout gradient acts as a spoiling gradient for the previous spoke. The custom raw data was reconstructed using a homemade image reconstruction software, which is programmed using Python language. The method was applied to a phantom and in-vivo human brain and abdomen. The performance of UTE was compared with 3D GRE for phase mapping. Local phase mapping was compared with T2* mapping using UTE. Results: The phase map using UTE mimics true field-map, which was theoretically calculated, while that using 3D GRE revealed both motion-induced artifact and geometric distortion. Motion-free imaging is particularly crucial for application of phase mapping for abdomen MRI, which typically requires multiple breathold acquisitions. The air pockets, which are caught within the digestive pathway, induce spatially varying and large background field. T2* map, that was calculated using UTE data, suffers from non-uniform T2* value due to this background field, while does not appear in the local phase map of UTE data. Conclusion: Phase map generated using UTE mimicked the true field map even when non-zero susceptibility objects were present. Phase map generated by 3D GRE did not accurately mimic the true field map when non-zero susceptibility objects were present due to the significant field distortion as theoretically calculated. Nonetheless, UTE allows for phase maps to be free of susceptibility-induced distortion without the use of any post-processing protocols.

High Resolution 3D Magnetic Resonance Fingerprinting with Hybrid Radial-Interleaved EPI Acquisition for Knee Cartilage T1, T2 Mapping

  • Han, Dongyeob;Hong, Taehwa;Lee, Yonghan;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권3호
    • /
    • pp.141-155
    • /
    • 2021
  • Purpose: To develop a 3D magnetic resonance fingerprinting (MRF) method for application in high resolution knee cartilage PD, T1, T2 mapping. Materials and Methods: A novel 3D acquisition trajectory with golden-angle rotating radial in kxy direction and interleaved echo planar imaging (EPI) acquisition in the kz direction was implemented in the MRF framework. A centric order was applied to the interleaved EPI acquisition to reduce Nyquist ghosting artifact due to field inhomogeneity. For the reconstruction, singular value decomposition (SVD) compression method was used to accelerate reconstruction time and conjugate gradient sensitivity-encoding (CG-SENSE) was performed to overcome low SNR of the high resolution data. Phantom experiments were performed to verify the proposed method. In vivo experiments were performed on 6 healthy volunteers and 2 early osteoarthritis (OA) patients. Results: In the phantom experiments, the T1 and T2 values of the proposed method were in good agreement with the spin-echo references. The results from the in vivo scans showed high quality proton density (PD), T1, T2 map with EPI echo train length (NETL = 4), acceleration factor in through plane (Rz = 5), and number of radial spokes (Nspk = 4). In patients, high T2 values (50-60 ms) were seen in all transverse, sagittal, and coronal views and the damaged cartilage regions were in agreement with the hyper-intensity regions shown on conventional turbo spin-echo (TSE) images. Conclusion: The proposed 3D MRF method can acquire high resolution (0.5 mm3) quantitative maps in practical scan time (~ 7 min and 10 sec) with full coverage of the knee (FOV: 160 × 160 × 120 mm3).

내부 그레디언트 정보를 이용한 일반화된 허프변환 (Generalized Hough Transform using Internal Gradient Information)

  • 장지영
    • 융합정보논문지
    • /
    • 제7권3호
    • /
    • pp.73-81
    • /
    • 2017
  • 일반화된 허프변환(GHough)은 임의의 2차원 모델 추출을 위해 사용되는 유용한 기법이다. 그러나 GHough는 모델의 회전과 축척 관련 사전 정보가 없을 경우 모든 경우의 수를 나열하는 변환 방식을 택하기 때문에 4차원 패러미터 배열이라는 방대한 메모리 사용이 불가피하며 실행시간 또한 오래 걸릴 수밖에 없다. 이를 개선하기 위해 제안된 몇몇 n-to-1 변환 방식 들은 4차원 대신 2차원 패러미터 배열 사용만으로도 임의의 모델 추출을 가능케 한 반면 2차원 패러미터 공간에 던져지는 무작위 투표 때문에 모델 추출 오류 가능성 또한 높다 하겠다. 본 논문은 이와 같은 2차원 패러미터 공간에 던져지는 무작위 투표를 감소시키기 위한 방안으로 모델 내부의 추가적인 그레디언트 정보 활용을 제안하며 모델 윤곽선 정보에 추가로 모델 내부 그레디언트 정보를 활용할 경우 2차원 패러미터 공간에 던져지는 무작위 투표수를 효과적으로 줄일 수 있으며 따라서 실행시간 또한 단축될 수 있음을 실험을 통해 입증한다.

슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가 (Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint)

  • 윤문현;성미숙;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.269-275
    • /
    • 2008
  • 슬관절 퇴행성 질환을 진단하기 위하여 자기공명영상(magnetic resonance imaging: MRI)이 많이 사용되지만 간혹 슬관절 병후 및 예후를 잘못 진단하는 경우가 종종 발생한다. 본 연구에서는 슬관절 질환의 진단에 도움을 주기 위하여 자화전이(magnetization transfer: MT) 영상법을 소개하고자 한다. 슬관절 환자 7명으로부터 스핀 에코(SE) T2 강조 영상(3,400-3,500/90-100 ms)과 슬관절 환자 7명으로부터 FSE T2 강조 영상(4,500-5,000/100-108 ms)과 또한 슬관절 환자 3명으로부터 gradient echo (GRE) T2 강조 영상들(9/4.56 ms, 50 flip angle, NEX 1)을 획득하였다. 6명의 슬관절 환자에서 지방 억제가능 T2 강조 STIR 펄스시퀀스(TR/TE=2894-3215 ms/70 ms, NEX 3, ETL 9)를 사용하였다. 지방 포화도에 있어서 위상감도 방법은 Larmor frequency 차이에 따른 위상 차이를 이용하므로, 각각의 픽셀에 대한 자화전이율(magnetization transfer ratio: MTR)의 측정은 포화된 영상과 포화되지 않은 영상의 비율에 따라 산출하였다. 따라서 각 입력된 영상들은 동차원성을 가지고, 시각적으로 신호강도 정도가 회색의 명암도만으로 평가될 수 있기 때문에 생리학적, 정량적 진단을 위하여 3차원 등방성 체적영상과 자기공명 삼원색을 매핑하였고 정량적 특정은 자화전이율 지도로서 표현하였다. 자화전이율 영상은 병변 부위에서 높은 대조도를 나타내어 환자의 병태를 추적하는데 도움을 주었고 정량화하였다. 자화전이율 영상들과 기존의 MRI 사이에 명암도 차이는 회색상으로 표현되며, 자화전이율 영상화의 효과에 대해 프로파일 그래프는 자화전이 펄스로 인하여 신호강도에 있어서 정량적 측정값이 상대적으로 감소하였다. 슬관절의 정확한 병리상태를 진단하기 위해 프로파일 그래프의 측정값을 영상과 함께 표현하였다. 본 연구에서 수행한 예비적 데이터들을 통하여 슬관절의 자화전이율 영상들이 매우 임상학적으로 유용함을 확인하였다. 자화전이율 영상에 대한 물리적 변화를 관찰함으로써 자화전이율 영상에 대한 물리적, 기술적 기반에 대한 더 많은 통찰력을 제공할 수 있다. 무릎 질환 환자의 자화전이율 영상들을 이용하여 매우 높은 대조도를 확보할 수 있으므로 슬관절 질환의 정밀 진단에 매우 도움을 줄 수 있다.

  • PDF