• Title/Summary/Keyword: 2D fluorescence sensor

Search Result 7, Processing Time 0.02 seconds

Monitoring of Biological Processes by 2-dimensional Fluorescence Sensor (2차원 형광센서에 의한 생물공정의 모니터링)

  • 이종일;정상윤;서국화
    • KSBB Journal
    • /
    • v.16 no.5
    • /
    • pp.493-499
    • /
    • 2001
  • This work presented the monitoring technique of biological processes by a 2-dimensional fluorescence sensor. The 2-dimensional fluorescence sensor can be used to monitor some important variable during cultivation processes simultaneously. In this study we have monitored fermentation processes of a few microorganisms such as recombinant E.coli, A. terreus and T. vulgaris. and investigated the change of the fluorescence spectra in the fermentation processes qualitatively. The 2-dimensional fluorescence sensor can be also used to monitor biochemical reactions and separation processes and applied for the optimization of biological processes.

  • PDF

Application of Principal Component Analysis and Self-organizing Map to the Analysis of 2D Fluorescence Spectra and the Monitoring of Fermentation Processes

  • Rhee, Jong-Il;Kang, Tae-Hyoung;Lee, Kum-Il;Sohn, Ok-Jae;Kim, Sun-Yong;Chung, Sang-Wook
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.5
    • /
    • pp.432-441
    • /
    • 2006
  • 2D fluorescence sensors produce a great deal of spectral data during fermentation processes, which can be analyzed using a variety of statistical techniques. Principal component analysis (PCA) and a self-organizing map (SOM) were used to analyze these 2D fluorescence spectra and to extract useful information from them. PCA resulted in scores and loadings that were visualized in the score-loading plots and used to monitor various fermentation processes with recombinant Escherichia coli and Saccharomyces cerevisiae. The SOM was found to be a useful and interpretative method of classifying the entire gamut of 2D fluorescence spectra and of selecting some significant combinations of excitation and emission wavelengths. The results, including the normalized weights and variances, indicated that the SOM network is capable of being used to interpret the fermentation processes monitored by a 2D fluorescence sensor.

Development of a pH/dissolved- oxygen Monitoring System Using HPTS and Rudpp (HPTS, Rudpp를 활용한 pH 및 용존산소 모니터링 시스템 연구)

  • Dong Hyuk Jeong;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.82-87
    • /
    • 2023
  • This study proposes a pH-dissolved-oxygen monitoring system using 8-HydroxyPyrene-1,3,6-trisulfonic acid Trisodium Salt (HPTS) and tris(4,7-diphenyl-1,10-phenanthroline)Ruthenium(II) chloride (Rudpp). Commercial water-quality sensors are electrochemical devices that require frequent calibration and cleaning, are subject to high maintenance costs, and have difficulties conducting measurements in real-time. The proposed pH-dissolved-oxygen monitoring system selects a thin-film sensing layer to measure the change in fluorescence intensity. This change in fluorescence intensity is based on reactions with hydrogen ions in an aqueous solution at a given pH and specific amount of dissolved oxygen. The change in fluorescence intensity is then measured using light-emitting diodes and photodiodes in response to HPTS and Rudpp. This method enables the development of a relatively small, inexpensive, and real-time measureable water-quality measurement system.

Acridine Fluorescence Behaviors in Different Polymeric Microenvironments Directed by C2-Proton-Acidity of Imidazolium-Based Ionic Liquids

  • Ji, Myoung-Jin;Kim, Jong-Gyu;Shin, Ueon-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.8
    • /
    • pp.2489-2493
    • /
    • 2012
  • A new fluorescent system (acridine/RTIL hybrid gel) confined in the 3D micro-structure of a poly(lactic acid) membrane were prepared from 1-butyl-3-methylimidazolium-based ionic liquids ([bmim]X (X = $SbF_6$, $NTf_2$, Cl); RTILs), poly(lactic acid) (PLA), and acridine via the sol-gel route. SEM images showed that, in the presence of [bmim]$SbF_6$ and [bmim]$NTf_2$, 3D-ly paticulated structures were created inside the PLA membranes and acridine/RTIL hybrid gels were confined in gabs of particulates. However, the use of [bmim]Cl induced the formation of a 3D-ly porous structure containing the hybrid gel of acridine/[bmimCl in the micropores. The three fluorescent systems exhibited different fluorescence behaviors (fluorescence maximum and intensity) depending on the C2-H acidity scale of the RTILs (or their anion type). Acridine gels hybridized with [bmim]$SbF_6$ and [bmim]$NTf_2$ showed blue fluorescence with relative high intensity, whereas the hybrid gel with [bmim]Cl exhibited almost no fluorescence under dry conditions. However, the acridine/[bmim]Cl hybrid system in the micro-porous PLA membrane started to emit fluorescent light under humid conditions and showed a possible response, indicating that it could be applied as a humidity sensor.

Fluorescent Crack Sensor in a Polymeric Material (고분자 재료의 형광 크랙센서)

  • Cho, Sung-Youl;Kim, Ji-Eun;Kim, Joong-Gon;Chung, Chan-Moon
    • Polymer(Korea)
    • /
    • v.32 no.2
    • /
    • pp.189-192
    • /
    • 2008
  • A styrylpyrylium salt (DHSP) was synthesized and then photodimerized to obtain a cyclobutane-type dimer (DHSP dimer). Methacryloyl group was incorporated into DHSP dimer to obtain DMSP dimer. Based on FT-IR analysis of a crosslinked DMSP dimer, it was considered that the cyclobutane structure reversed to styryl C=C bonds upon crack formation. Fluorescence measurement of DHSP in solid state (excitation at 385 nm) showed emission centered at 626 nm, while DHSP dimer revealed very weak emission. Fluorescent emission from microcracks in a film of crosslinked DMSP dimer was observed upon exposure to $330{\sim}385\;nm$ light.

Comparison of organic EL characteristics of low mass dye and polymer material with the same chromophore (동일한 발광기를 가진 저분자색소와 고분자물질의 유기 EL특성의 비교)

  • Kim, Dong-Uk
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 1999
  • A Polymer material, PU-BCN and a low molar mass material D-BCN with the same chromophore were evaluated by fabricating various electroluminescent(EL) devices. A molecular structure of the chromophore was composed as two cyano groups for electron-injection and transport and two triphenylamine groups for hole-injection and transport. Various kinds of EL devices with two different types of EL materials, PU-BCN and D-BCN were fabricated, which were an Indium-tin oxide(ITO)/PU-BCN or D-BCN/MgAg device as a single-layer device(SL) and an ITO/PU-BCN or D-BCN/oxadiazole ferivative/MgAg as a double-layer device(DL-E) and an ITO/triphenylamine derivative/D-BCN/MgAg as a double-layer device(DL-H) device. Two kinds of materials, PU-BCN and D-BCN showed the same emission characteristics in the high current density and excellent EL characteristics even in the SL devices. Maximum EL peaks revealed red emission of about 640 nm, which were corresponded with the fluorescence peaks of the films of two materials.

  • PDF

Studies on Membrane Fouling Monitoring by Fluorescence Nano Particle and Fluorescent Spectrometry (형광 나노 입자 및 형광 분광 분석을 이용한 막오염 측정법 연구)

  • Seo, Mi-Rae;Nam, Mi-Yeon;Kim, Beom-Sik;Nam, Seung-Eun;Kim, In-Chul;Park, You-In
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.163-170
    • /
    • 2011
  • Membrane fouling control in water treatment may be the main obstacle for wider implementation and lower cost. A novel fluorescent spectroscope sensor device for membrane fouling integrity monitoring has been developed and evaluated in this study. PSf membranes for water treatment has been fabricated with three types of organic fluorescent materials, OB, FP, KCB. The fluorescent signal from membrane surface was analyzed throughout the filtration process. It was found that the fluorescent signal due to the membrane fouling decreased and the developed device is reliable for membrane fouling monitoring.