• Title/Summary/Keyword: 2D Video

Search Result 910, Processing Time 0.029 seconds

Intensity Compensation for Efficient Stereo Image Compression (효율적인 스테레오 영상 압축을 위한 밝기차 보상)

  • Jeon Youngtak;Jeon Byeungwoo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.101-112
    • /
    • 2005
  • As we perceive the world as 3-dimensional through our two eyes, we can extract 3-dimensional information from stereo images obtained from two or more cameras. Since stereo images have a large amount of data, with recent advances in digital video coding technology, efficient compression algorithms have been developed for stereo images. In order to compress stereo images and to obtain 3-D information such as depth, we find disparity vectors by using disparity estimation algorithm generally utilizing pixel differences between stereo pairs. However, it is not unusual to have stereo images having different intensity values for several reasons, such as incorrect control of the iris of each camera, disagreement of the foci of two cameras, orientation, position, and different characteristics of CCD (charge-coupled device) cameras, and so on. The intensity differences of stereo pairs often cause undesirable problems such as incorrect disparity vectors and consequent low coding efficiency. By compensating intensity differences between left and right images, we can obtain higher coding efficiency and hopefully reduce the perceptual burden of brain to combine different information incoming from two eyes. We propose several methods of intensity compensation such as local intensity compensation, global intensity compensation, and hierarchical intensity compensation as very simple and efficient preprocessing tool. Experimental results show that the proposed algerian provides significant improvement in coding efficiency.

Design of video encoder using Multi-dimensional DCT (다차원 DCT를 이용한 비디오 부호화기 설계)

  • Jeon, S.Y.;Choi, W.J.;Oh, S.J.;Jeong, S.Y.;Choi, J.S.;Moon, K.A.;Hong, J.W.;Ahn, C.B.
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.732-743
    • /
    • 2008
  • In H.264/AVC, 4$\times$4 block transform is used for intra and inter prediction instead of 8$\times$8 block transform. Using small block size coding, H.264/AVC obtains high temporal prediction efficiency, however, it has limitation in utilizing spatial redundancy. Motivated on these points, we propose a multi-dimensional transform which achieves both the accuracy of temporal prediction as well as effective use of spatial redundancy. From preliminary experiments, the proposed multi-dimensional transform achieves higher energy compaction than 2-D DCT used in H.264. We designed an integer-based transform and quantization coder for multi-dimensional coder. Moreover, several additional methods for multi-dimensional coder are proposed, which are cube forming, scan order, mode decision and updating parameters. The Context-based Adaptive Variable-Length Coding (CAVLC) used in H.264 was employed for the entropy coder. Simulation results show that the performance of the multi-dimensional codec appears similar to that of H.264 in lower bit rates although the rate-distortion curves of the multi-dimensional DCT measured by entropy and the number of non-zero coefficients show remarkably higher performance than those of H.264/AVC. This implies that more efficient entropy coder optimized to the statistics of multi-dimensional DCT coefficients and rate-distortion operation are needed to take full advantage of the multi-dimensional DCT. There remains many issues and future works about multi-dimensional coder to improve coding efficiency over H.264/AVC.

New Decision Rules for UWB Synchronization (UWB 동기화를 위한 새로운 결정 법칙들)

  • Chong, Da-Hae;Lee, Young-Yoon;Ahn, Sang-Ho;Lee, Eui-Hyoung;Yoo, Seung-Hwan;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2C
    • /
    • pp.192-199
    • /
    • 2008
  • In ultra-wideband (UWB) systems, conventionally, the synchronization is to align time phases of a locally generated template and any of multipath components to within an allowable range. However, the synchronization with a low-power multipath component could incur significant performance degradation in receiver operation (e.g., detection) after the synchronization. On the other hand, the synchronization with a high-power multipath component can improve the performance in receiver operation after the synchronization. Generally, the first one among multipath components has the largest power. Thus, the synchronization with the first path component can make better performance than that with low-power component in receiver operation after the synchronization, Based on which, we first propose an optimal decision rule based on a maximum likelihood (ML) approach, and then, develope a simpler suboptimal decision rule for selecting the first path component. Simulation results show that the system has good demodulation performance, which uses new synchronization definition and the proposed decision rules have better performance than that of the conventional decision rule in UWB multipath channels. Between macroblocks in the previous and the current frame. On video samples with high motion and scene change cases, experimental results show that (1) the proposed algorithm adapts the encoded bitstream to limited channel capacity, while existing algorithms abruptly excess the limit bit rate; (2) the proposed algorithm improves picture quality with $0.4{\sim}0.9$dB in average.

A Methodology for Making Military Surveillance System to be Intelligent Applied by AI Model (AI모델을 적용한 군 경계체계 지능화 방안)

  • Changhee Han;Halim Ku;Pokki Park
    • Journal of Internet Computing and Services
    • /
    • v.24 no.4
    • /
    • pp.57-64
    • /
    • 2023
  • The ROK military faces a significant challenge in its vigilance mission due to demographic problems, particularly the current aging population and population cliff. This study demonstrates the crucial role of the 4th industrial revolution and its core artificial intelligence algorithm in maximizing work efficiency within the Command&Control room by mechanizing simple tasks. To achieve a fully developed military surveillance system, we have chosen multi-object tracking (MOT) technology as an essential artificial intelligence component, aligning with our goal of an intelligent and automated surveillance system. Additionally, we have prioritized data visualization and user interface to ensure system accessibility and efficiency. These complementary elements come together to form a cohesive software application. The CCTV video data for this study was collected from the CCTV cameras installed at the 1st and 2nd main gates of the 00 unit, with the cooperation by Command&Control room. Experimental results indicate that an intelligent and automated surveillance system enables the delivery of more information to the operators in the room. However, it is important to acknowledge the limitations of the developed software system in this study. By highlighting these limitations, we can present the future direction for the development of military surveillance systems.

The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy (방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Patient dose verification is one of the most Important responsibilities of the physician in the treatment delivery of radiation therapy. For the task, it is necessary to use an accurate dosimeter that can verify the patient dose profile, and it is also necessary to determine the physical characteristics of beams used in intensity modulated radiation therapy (IMRT) The Beam Intensity Scanner (BInS) System is presented for the dosimetric verification of the two dimensional photon beam. The BInS has a scintillator, made of phosphor Terbium-doped Gadolinium Oxysulphide (Gd$_2$O$_2$S:Tb), to produce fluorescence from the irradiation of photon and electron beams. These fluoroscopic signals are collected and digitized by a digital video camera (DVC) and then processed by custom made software to express the relative dose profile in a 3 dimensional (3D) plot. As an application of the BInS, measurements related to IWRT are made and presented in this work. Using a static multileaf collimator (SMLC) technique, the intensity modulated beam (IMB) is delivered via a sequence of static portals made by controlled leaves. Thus, when static subfields are generated by a sequence of abutting portals, the penumbras and scattered photons of the delivered beams overlap in abutting field regions and this results in the creation of “hot spots”. Using the BInS, inter-step “hot spots” inherent in SMLC are measured and an empirical method to remove them is proposed. Another major MLC technique in IMRT, the dynamic multileaf collimator (DMLC) technique, has different characteristics from SMLC due to a different leaf operation mechanism during the irradiation of photon and electron beams. By using the BInS, the actual delivered doses by SMLC and DMLC techniques are measured and compared. Even if the planned dose to a target volume is equal in our experimental setting, the actual delivered dose by DMLC technique is measured to be larger by 14.8% than that by SMLC, and this is due to scattered photons and contaminant electrons at d$_{max}$.

  • PDF

Playing Trauma -A Study on the Representation of History in Taiwan Horror Game Detention (플레잉 트라우마 -대만 호러게임 <반교>의 역사 재현 연구)

  • Bae, Ju-Yeon
    • Journal of Popular Narrative
    • /
    • v.26 no.2
    • /
    • pp.87-122
    • /
    • 2020
  • This study explores the method of representation of traumatic history in 2D horror game Detention developed by Taiwan game production company Red Candle through an analysis of its method of storytelling. Unlike conventional public media, video/digital games are based on interactivity, in which game players engage in the narratives. Thus, the relationship between players and the history in the game world may also change. This research investigates how the players build their way of remembering and recognizing the past in a different relationship. Detention, which was well received, not only in Taiwan but also around the world upon its launch in 2017, is set in a middle school during the martial law era in Taiwan in the 1960s. In the game, the main character encounters her lost memories in the process of following clues and game rules, and finally realizes she is implicated in the 1960s' event. Detention was cinematized after the success of the game. The film achieved enormous popularity both in terms of box office success and criticism. In this paper, the strategy of the game's storytelling is introduced in comparison to the film's approach in the representation of historical events. In particular, the paper explores elements such as the interactivity of the game medium, narrative fragmentation, quests, hints and cues, and the horror genre, that asks users to understand history beyond the game world differently from the point of view of other media. Though this study, it can be considered that the digital game is a medium exploring history in a serious manner. In particular, Detention invokes the matter of game-mnemonics as well as cine-mnemonics. Compared to plentiful research in cine-mnemonics, game-mnemonics has not been extensively studied to date. Therefore, through the analysis of Detention, this paper explores the relationship between digital games, history and memory.

Effects of a Self-Help Program including Stretching Exercise on Reduction of Symptom in Patients with Fibromyalgia (신장운동을 포함한 자조관리프로그램이 섬유조직염환자의 증상완화에 미치는 효과)

  • Han, Sang-Sook
    • Journal of muscle and joint health
    • /
    • v.5 no.1
    • /
    • pp.39-56
    • /
    • 1998
  • This study was an quasi-experimental study, done to identify factors Influencing the reduction of symptoms in patients with fibromyalgia. The primary purpose of the study was to develop a Self-Help Program suitable for patients with fibromyalgia in Korea. The secondary purpose was to identify the effects of a Self-Help Program which included stretching exercise. This study was carried out between Feb. 24 and July 8, 1997 and patients in the study Included out patient diagnosed with fibromyalgia based on the criteria developed by the American College of Rheumatology(1990) and H, University which is a tertiary patient care clinic for Rheumatism. The experimental group included 38 patients who were residents of Seoul or Kyungi province, and a control group of 38 patients who were residents of other areas. The control patients were matched to the experimental group patients and they were selected considering the number of tender points on the Fibromyalgia Impact Questionnaire score and a score of self-efficacy. The experimental group participated in a Self-Help Program based on the American Arthritis Foundation(1995) guidelines. The program participants participated in a small group which consisted of 12-15 members attending the program once a week, for 6 weeks with each program lasted two to two and a half hours. The stretching exercise was carried out in each patient's home every day following the video tape exercise provided by the researcher, and the researcher provided encouragement and concern to the patients by calling them once a week. The number times the exercise was performed was divided by the number of participants to calculate the percentage of performance and determine the amount of exercise. Self-efficacy was measured by the Self-Efficacy Scale developed by Lorig et al. (1989) for arthritis patients. The degree of pain was converted to scores based on the Visual Analog Scale, the number of tender points was converted to scores based on the criteria of the ACR(1990) and of Yunus. Depression was measured by CES-D and physical disability, sleep disturbance, fatigue, and anxiety of patients with fibromyalgia were measured by the Fibromyalgia Impact Questionnaire. The level of the exercise performance was converted to scores using the number of times the exercise was performed following the video tape prepared by Association of Rheumatology Health Professionals. Data were analyzed by SPSS windows and the results ire described below. 1. The experimental group which participated in the Self-Help Program showed higher efficacy scores than the control group when both groups were analyzed for depression and the number of tender points as common variables(F=9.146, p=.003). 2. The experimental group which participated in the Self-Help Program showed lower scores than the control group, for pain, the number of tender points, depression, physical disability, fatigue, sleep disturbance and anxiety. These symptoms of fibromyalgia can all be seen to have subsided(F=9.483, p=.003 : F=32.680, p=.001 ; F=11.104, p=.001, F=5.344 : p=.024, F=7.630 : P=.007, F=15.6512, p=.003 : F= 7.5412, p=.008). 3. In the experimental group, the self-efficacy score for the first three weeks showed a positive correlation with the exercise-performance score for four to six weeks (r=.387, p=.043). 4. In the experimental group, the relationship between the level of exercise-performance and the reduction of symptoms showed a significant correlation only to physical disability(r= -.500, p=.001). 5. In the experimental group, the relationship between the self-efficacy score and pain, the number of tender points, depression, physical disability, fatigue, sleep disturbance and anxiety score showed inverse correlations and thus, a reduction of symptoms occured when the self-efficacy score increased(r=-.325, p=.004 ; r= -.253, p=.027, r=-.452, p=.001 : r=-.434, p=.001 ; r=-.316, p=.005 ; r=-.460, p=.001 ; r=-.397, p=.014). Therefore, self-efficacy improved following the Self-Help Program including the stretching exercise. It was also found that physical symptoms (pain, number of tender points, level physical disability) and psychological symptoms (depression, fatigue, sleep disturbance, anxiety) were reduced. Moreover, It was found that the higher the self-efficacy, the the higher the degree of achievement of goals set for the stretching exercises. In addition, the level of exercise-performance influenced the level of physical disability, one of the symptoms of fibromyalgia. Accordingly, the conclusions from this study are that exercise-performance and the reduction of symptoms is achieved through promotion of self-efficacy. Therefore, it is proposed that are the Self-Help Program including stretching exercises is an appropriate nursing intervention for the reduction of symptoms of fibromyalgia.

  • PDF

Evaluation of Cerebral Cortices Associated with Sexual Arousal in Healthy Male Using BOLD-based Functional MRI

  • Kim, Hyung-Joong;Seo, Jeong-Jin;Kang, Heoung-Keun;Jeong, Gwang-Woo;Park, Jin-Gyoon;Jeong, Yong-Yeon;Chung, Tae-Woong;Woong Yoon;Park, Kwang-Sung
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.137-137
    • /
    • 2001
  • Purpose: The purpose of this study was to identify cerebral cortices related with sexual arousal fro visual sexual stimulation in healthy males using BOLD-based functional MR imaging Method: Sixteen male volunteers with sexually potent(mean age:24) were examined for thi study. Functional MRI was performed on a 1.5T MR scanner(GE Signa Horizon) with birdcage-type head coil. In this study, blood oxygenation level dependent(BOLD) technique was utilized to create fMR image reflecting local brain activities. The BOLD-based fMRI d were obtained from 7 oblique planes using gradient-echo EPI with $90^{\circ}$flip angle, 50ms TE 6000ms TR, $26cm{\times}26$ cm FOV, $128{\times}128$ matrix, and 10mm slice thickness. The sexual stimulation paradigm consisted of two alternating periods of rest and activati and it began with a 1 minute rest, followed by a 2 minute stimulation by a documentary a erotic video film. Brain activation maps were generated by cross-correlation of imag acquired during rest and activation periods. The index of activation was used to compare t number of pixels activated by each task in each volunteer, where the significance of th differences was evaluated by using Students t-test.

  • PDF

Measurement of Respiratory Motion Signals for Respiratory Gating Radiation Therapy (호흡동조 방사선치료를 위한 호흡 움직임 신호 측정)

  • Chung, Jin-Beom;Chung, Won-Kyun;Kim, Yon-Lae;Lee, Jeong-Woo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.59-63
    • /
    • 2005
  • Respiration motion causes movement of internal structures in the thorax and abdomen, making accurate delivery of radiation therapy to tumors in those areas a challenge. Accounting for such motion during treatment, therefore, has the potential to reduce margins drawn around the clinical target volume (CTV), resulting in a lower dose to normal tissues (e.g., lung and liver) and thus a lower risk of treatment induced complications. Among the techniques that explicitly account for intrafraction motion are breath-hold, respiration gating, and 4D or tumor-tracking techniques. Respiration gating methods periodically turn the beam on when the patient's respiration signal is in a certain part of the respiratory cycle (generally end-inhale or end-exhale). These techniques require acquisition of some form of respiration motion signal (infrared reflective markers, spirometry, strain gauge, thermistor, video tracking of chest outlines and fluoroscopic tracking of implanted markers are some of the techniques employed to date), which is assumed to be correlated with internal anatomy motion. In preliminary study for the respiratory gating radiation therapy, we performed to measurement of this respiration motion signal. In order to measure the respiratory motion signals of patient, respiration measurement system (RMS) was composed with three sensor (spirometer, thermistor, and belt transducer), 4 channel data acquisition system and mobile computer. For two patients, we performed to evaluation of respiratory cycle and shape with RMS. We observed under this system that respiratory cycle is generally periodic but asymmetric, with the majority of time spent. As expected, RMS traced patient's respiration each other well and be easily handled for application.

  • PDF

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF