• 제목/요약/키워드: 2D Imaging

검색결과 1,148건 처리시간 0.029초

HWAW방법을 사용한 지반의 전단파 속도 2-D 영상화 (Two-dimensional imaging of shear wave velocity in the soil site using HWAW method)

  • 박형춘;김동수;김종태;박헌준;방은석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.7-13
    • /
    • 2008
  • To obtain a shear-wave velocity profile in geotechnical practice, various seismic investigation methods which have their own strength and weakness are being frequently used. Generally, geotechnical site have lateral variation of the properties, so it is needed to determine 2-dimensional shear wave velocity imaging of the site. In this study, harmonic wavelet analysis of wave (HWAW) method is applied to determination of 2-D $V_s$ imaging. HWAW method which is based on time-frequency analysis using harmonic wavelet transform have been developed to determine phase and group velocities of waves. HWAW method uses the signal portion of the maximum local signal/noise ratio to evaluate the phase velocity to minimize the effects of noise. HWAW method determine detailed local $V_s$ profile because one experimental setup which consists of one pair of receivers with spacing of 1~3m is used to determine the dispersion curve of the whole depth. So, 2-D Vs imaging with relatively high resolution can be determined through a series of HWAW test. In order to estimate the applicability of HWAW method, field tests were performed in 4 sites. Through field applications and comparison with other test results, the good accuracy and applicability of the proposed method were verified.

  • PDF

Development of Ultrasonic Wave Propagation Imaging System

  • Chia, Chen-Ciang;Lee, Jung-Ryul;Kim, Jong-Heon
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.283-292
    • /
    • 2009
  • Laser-based ultrasonic sensing requires the probe with fixed fecal length, but this requirement is not essential in laser-based ultrasonic generation. Based on this fact, we designed a pulsed laser-based ultrasonic wave propagation imaging (UWPI) system with a tilting mirror system for rapid scanning of target, and an in-line band-pass filtering capable of ultrasoaic mode selection. 1D-temporal averaging, 2D-spatial averaging, and 3D-data structure building algorithms were developed far clearer results allowing fur higher damage detectability. The imaging results on a flat stainless steel plate were presented in movie and snapshot formats which showed the propagation of ultrasound visible as a concentric wavefield emerging from the location of an ultrasonic sensor. A hole in the plate with a diameter of 1 mm was indicated by the scattering wavefields. The results showed that this robust UWPI system is independent of focal length and reference data requirements.

High-Resolution 3-D Refractive Index Tomography and 2-D Synthetic Aperture Imaging of Live Phytoplankton

  • Lee, SangYun;Kim, Kyoohyun;Mubarok, Adam;Panduwirawan, Adisetyo;Lee, KyeoReh;Lee, Shinhwa;Park, HyunJoo;Park, YongKeun
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.691-697
    • /
    • 2014
  • Optical measurements of the morphological and biochemical imaging of phytoplankton are presented. Employing quantitative phase imaging techniques, 3-D refractive index maps and high-resolution 2-D quantitative phase images of individual live phytoplankton are simultaneously obtained without exogenous labeling agents. In addition, biochemical information of individual phytoplankton including volume, mass, and density of individual phytoplankton are also quantitatively obtained from the measured refractive index distributions. We expect the present method to become a powerful tool for the study of phytoplankton.

고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징 (Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo)

  • 조한샘;장선주;오왕열
    • 한국광학회지
    • /
    • 제25권2호
    • /
    • pp.67-71
    • /
    • 2014
  • 혈관 내 OCT (optical coherence tomography) 는 혈관 벽 내부의 3차원적 미세구조를 영상화할 수 있어서 임상에서 각광을 받고 있다. 하지만 아직도 충분하지 못한 이미징 속도, 특히 내시경 프로브의 이미징 광 스캐닝 속도의 부족으로 혈관 길이 방향의 이미징 간격이 실제 시스템의 광학적 해상도보다 5배 이상 커서 혈관 종방향으로의 고해상도 이미징이 얻어지지 못하고 있는 상황이다. 본 논문에서는 초당 350장의 혈관 벽 단층 영상을 제공하는 고속 혈관 내 OCT 시스템을 기술한다. 본 시스템과 내시경 장치를 이용하여 47 mm 길이의 살아있는 토끼 대동맥을 3.7초만에 34 micron의 혈관 종방향 간격으로 얻는데 성공하였다. 34 micron의 종방향 간격은 실제 내시경의 그 방향 광학적 해상도와 비슷한 정도로서 3차원 모든 방향으로의 고해상도 이미징을 구현하였음을 보여준다. 얻어진 이미징 데이터의 3차원 영상 구현을 통해 혈관의 미세구조 및 이미징 전 삽입된 스텐트의 자세한 구조를 보였다.

안테나 결합형 볼로미터 방식 테라헤르츠 센서를 이용한 이차원 주사 방식의 투과형 테라헤르츠 영상 취득에 관한 연구 (Terahertz Transmission Imaging with Antenna-Coupled Bolometer Sensor)

  • 이경일;임병직;원종석;홍성민;박재현;이대성
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.311-316
    • /
    • 2018
  • An antenna-coupled bolometer-type terahertz sensor was designed, fabricated, evaluated, and utilized to obtain terahertz transmission images. The sensor consists of a thin film bowtie antenna that resonates accordingly in response to an incident terahertz beam, a heater that converts the applied current in the antenna into heat, and a microbolometer that converts the rise in temperature into a change in resistance. The device is fabricated by a bulk micromachining process on a 4-inch silicon wafer. The fabricated sensor chip has a size of $2{\times}2mm$ and an active area of $0.1{\times}0.1mm^2$. The temperature coefficient of resistance (TCR) of the bolometer film (VOx) is 2.0%, which is acceptable for bolometer applications. The output sensor signal is proportional to the power of the incident terahertz beam. Transmission images were obtained with a 2-axis scanning imaging system that contained the sensor. The small active area of the sensor will enable the development of highly sensitive focal plane array sensors in terahertz imaging cameras in the future.

Universal Stereoscopic Display Using 64 LCD's

  • Takaki, Yasuhiro
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.289-292
    • /
    • 2002
  • A new technique to construct an auto-stereoscopic display that offers massive horizontal parallax images is proposed Multiple telecetnric imaging systems are arranged in a modified 2D array. The horizontal parallax images displayed by LCD panels are imaged to be superimposed on a 3D screen. All parallax images are displayed in the different horizontal directions because all imaging systems have different horizontal positions. The difference of the vertical display directions due to the imaging system's vertical positions is canceled by a vertical diffuser placed at the 3D screen. Observers can percept 3D images with the binocular disparity, the vergence, and the smooth motion parallax. In addition, the accommodation function may also work because a number of parallax images are displayed with a very small angle interval in the horizontal direction. A prototype 3D display including 64 color LCD panels was constructed.

  • PDF

DIR 영상을 이용한 피질두께 측정: GRAPPA 인자 2를 이용한 비교 (Cortical Thickness Estimation Using DIR Imaging with GRAPPA Factor 2)

  • 최나래;남윤호;김동현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권1호
    • /
    • pp.56-63
    • /
    • 2010
  • 목적 : 본 논문에서는 DIR 영상을 이용하여 두뇌의 피질두께측정 연구를 수행하는 한편 평행 영상기법 중 하나인 GRAPPA (generalized autocalibrating partially parallel acquisitions)를 이용하여 GRAPPA 인자 (reduction factor, R)가 2일 때와 평행 영상기법을 이용하지 않았을 때의 결과 비교를 통해 3D DIR 영상의 획득시간 단축 가능성을 제시하고자 한다. 대상 및 방법 : 3.0T 자기공명영상장치 (Siemens Tim Trio MRI scanner)의 3D DIR 펄스열을 이용하여 6명(남자 3명, 여자 3명, $25.33{\pm}2.25$살)의 정상인 뇌에 대한 3차원 영상을 얻었다. GRAPPA 시뮬레이션은 R=2 일 때를 가정하여 수행되었고 두뇌 피질두께측정을 위해 Analyze 9.0과 Freesurfer v.4.3.0 프로그램을 사용하였다. 결과로 얻은 데이터를 T-검증을 이용하여 비교분석 하였다. 결과 : GRAPPA 기법을 통하여 복원한 영상이 잡음이 증가하는 경향을 보였으나 두뇌 피질두께 측정에는 별다른 영향을 미치지 않았다. 통계분석을 통해 비교한 결과 대부분의 두뇌 영역에서 참조영상과 GRAPPA 기법을 이용한 영상의 차이가 유의하지 않았다. 결론 : 피질두께측정 연구에 있어서 3D DIR영상의 문제점 중 하나는 긴 영상획득시간이다. 따라서 평행영상 기법 중 하나인 GRAPPA 영상기법을 적용하면 피질두께측정 연구결과의 큰 차이없이 영상 획득 시간을 단축시킬 수 있다.

평면기반 컴퓨터 집적 영상 복원 기술의 신호모델을 이용한 3D 복원 영상 분석 (Analysis of 3D reconstructed images based on signal model of plane-based computational integral imaging reconstruction technique)

  • 신동학;유훈
    • 한국정보통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.121-126
    • /
    • 2009
  • 평면기반 컴퓨터 집적 영상 복원 (CIIR)기술은 3D 물체에 대한 깊이 영상복원이 가능한 기술이다. 그러나 복원되는 깊이에 따라 영상에 잡음이 발생하게 되어 해상도를 저하시키는 문제점이 있다. 본 논문에서는 이 문제점을 극복하기 위해서 CIIR 기술에 대한 신호 모델을 설명하고, 이를 통하여 CIIR 기술에 발생하는 잡음과 이를 보정하는 방법을 소개한다. 컴퓨터적 실험을 통하여 2D Gaussian 영상의 복원 영상에 대한 잡음 특성을 조사하고, 보정 과정을 통하여 고해상도의 영상을 얻을 수 있음을 보였다.

2D TOF 자기공명 혈관조영술에서 동맥혈류의 역류로 인한 영상훼손과 이의 제거 (Artifacts due to Retrograde Flow in the Artery and Their Elimination in 2D TOF MR Angiography)

  • 정관진;이종권;김선경;박성홍
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권1호
    • /
    • pp.38-42
    • /
    • 2001
  • 2D TOF혈관조영술에서 presaturation RF펄스를 사용하여 정맥피에서 나오는 MR신호를 제거하고 얻은 동맥 angiogram에는 band형태로 동맥이 끊어져 나타나는 현상이 자주 보인다. 일부 동맥에서 피의 흐름은 한 심장 주기 동안에 3번의 펄스를 갖는데, 이 중 가운데 펄스는 짧은 기간 동안 역류를 한다. 이 역류하는 동맥피는 정맥피와 같은 방향이기 때문에 presaturation RF펄스에 의해 정맥피 처럼 saturation이 되어서 imaging slice로 흘러 들어가게 될 수 있다. 특히 이러한 경우가 phase encoding step의 dc 부근에서 발생하게 되면 그 때의 단면 영상에서 동맥이 강조가 될 수 없게 되어, 결과적으로 angiogram에는 그 단면을 지나는 동맥의 신호가 없어서 band 형태로 핏줄이 끊어져 나타나게 된다. Imaging slice와 saturation band와의 간격을 변화 시켜 가면서 angiogram을 얻어 봄으로서 이러한 현상을 실험적으로 확인하였다 나아가 saturation band를 rectangle형태에서 ramp 형태로 변경함으로써 이러한 artifacts를 제거 할 수 있는 방법을 제시하였다

  • PDF

열음향 응용을 위한 1 kW급 UHF 대역 반도체 펄스 전력증폭기 (UHF-Band 1 kW Solid State Pulsed Power Amplifier for Thermoacoustic Imaging Application)

  • 이승민;박승표;최승범;이문규
    • 한국전자파학회논문지
    • /
    • 제27권1호
    • /
    • pp.92-95
    • /
    • 2016
  • 본 논문에서는 UHF 대역인 900 MHz에서 열음향 영상(thermoacoustic imaging, TAI) 응용을 위한 1 kW급 반도체 펄스 전력 증폭기를 설계 및 제작하였다. 반도체 펄스 전력 증폭기는 단펄스(short pulse) 동작을 위하여 펄스 폭 $80{\mu}s$, 듀티사이클 1 %, 900 MHz의 캐리어 주파수 조건에서 설계되었다. 전체 전력 증폭기는 16개의 단일 전력 증폭기를 윌킨슨 전력 분배기를 통해 결합하여 제작되었고, 사용된 능동 소자는 Freescale사의 MRFE6P9220HR3 LDMOSFET이 사용되었다. 제작된 전력 증폭기는 입력 전력이 -16 dBm일 때 중심주파수에서 60.2 dBm의 출력 전력과 76.2 dB의 전력 이득, 그리고 25 %의 드레인 효율 특성을 나타내었다.