• Title/Summary/Keyword: 2D:4D

Search Result 28,384, Processing Time 0.075 seconds

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

Influence of Edible Oil, Casein, Calcium and Magnesium on Serum Cholesterol Level in Rabbit (식용유, 카제인 및 칼슘, 마그네슘 첨가식이가 토끼의 혈청 Cholesterol 치에 미치는 영향)

  • Nam, Hyun Keun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.12 no.2
    • /
    • pp.122-136
    • /
    • 1983
  • The effect of dietary casein, calcium, magnesium and some vegetable oils such as seasme, perilla and soybean oil on the serum cholesterol level in the rabbit were studied for a period of 5 weeks using isocalories and isonitrogenous as basal diets. The experimental rabbits fed the following basal diets containing crude protein 68.47%, carbohydrates 13.35%. fats 16.18% and vegetable oil 10%. casein 10%, calcium and magnesium according to experimental plan making. In order to calculate the feeding efficiency, protein efficiency and calorie efficiency during period, the body weight gains were measured at the same time using same balance, respectively. The results are summarized as follows. Body weight gains per week of the group fed perilla oil, calcium and basal diet were the higher than any other groups. And body weights gains per week of the group fed basal diet, vegetable oil were the lower than any other groups. In the case of efficiency of reed, protein and calorie, the efficiency ratios of the group fed perilla oil were the higher than any other groups. Especially, perilla oil and calcium diet effect on body weight gain in rabbit. In the case of serum protein, the total proteins in serum were almost same value for all the groups. Serum albumin of group fed basal diet. vegetable oil and casein were the higher than any other groups. The ${\alpha}$-globulin of the groups, fed basal diet and calcium was the lower than any other grosps. The ${\beta}$-globulins of the groups fed basad diet, perilla oil and casein were the highest value. In serum lipoprotein, lipalbumin was almost same value for the groups fed vegetable oil, but fed vegetable oil and calcium diet was the lowest value. The ${\beta}$-lipoprotein in high cholesterol level group was increased some degree, the group fed perilla oil added was lower. The ratio of ${\beta}$-lipoprotein per lipalbumin was from 0.11 to 0.26. The ratio of lipalbumin per total lipoprotein was high in calcium and soybean oil added diet. In serum triglyceride, the level of triglyceride of groups fed seasme oil or perilla oil was the higher than any othe groups, but in the group fed casein and calcium or magnesium, the level of triglyceride level was decreased. Calcium and magnesium effect on triglyceridge level lowering action. In serum total cholesterol, the group does fed vegetable oil with basal diet and casein added more, total cholesterol level increased as much as triglyceride level increased. But the group does fed perilla oil and magnesium shows total cholesterol level decreased remarkably. In the group fed basal diet with calium, the amount of serum calcium was increased, but of serum magnesium was decreased. In the case of blood glucose, the group fed basal diet and vegetable oil was decreased. According to the regression and correlation coefficient in blood components in rabbit, there are positive correlation $${\gamma}{\sim_=}1$$ between serum cholesterol and triglyceride, ${\beta}$-lipoprotein, ${\alpha}$-globulin, calcium and magnesium according to diet composition. From the above results, the serum cholesterol level lowering factors in rabbit, was the amount of triglyceride and ${\beta}$-lipoprotein which was decreased in perilla oil fed. It assumes that serum cholesterol and triglyceride level lowering factors are not only unsaturation degree of fatty acid but the amount of calcium and magnesium and the ratio calcium per magnesium 2:1 in the diet.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

The oldest Maehyang-bi (埋香碑) of Memorial Inscriptions existing on record; Yeong-am's 'Jeongwon (貞元)' Stone Monument (현존 최고(最古)의 매향비(埋香碑): 영암 정원명(貞元銘) 석비(石碑))

  • Sung, Yungil
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.1
    • /
    • pp.70-99
    • /
    • 2021
  • Yeong-am's 'Jeongwon (貞元)' stone monument, designated as the Jeollanam-do Cultural Heritage, is considered to be the oldest of the epigraphs in Jeollanam-do. Immediately after the discovery, the possibility of it being a Maehyangbi of Memorial Inscriptions was mentioned and attracted attention. However, there is an absolute age of the 'Jeongwon (貞元) of 2 years' (786), so despite it is a relatively early epigraph (金石文), there are not many papers on the theme related to this stone monument. I believe that this stone monument is a Maehyangbi (埋香碑). While reviewing and comparing the results of the existing research, I decoded the text from the 42nd character of the 4th line. As a result of the review, that was conducted, it was confirmed that this stone monument is truly a Maehyangbi (埋香碑). In particular, it was recorded in the literature of the late Joseon Dongguk-myungsanggi (東國名山記) that the letters of the Maehyangbi (埋香碑) are not recognizable. However, it is clearly stated that this stone monument is a Maehyangbi (埋香碑). Although there is no common expression for 'bury (埋)' or 'incense burial (埋香)' in the traditional Maehyangbi (埋香碑), which were popular in the late Goryeo and early Joseon Periods, it can be seen that it is a Maehyangbi (埋香碑) from the words "hide (呑藏)" and "10 bundles of fragrant incense (合香十束)" that are engraved on the stone monument with the name 'Jeongwon.' In other words, it is thought that it meant 'hide (呑藏)' instead of 'bury (埋)'. Circumstantial evidence for the monument of Jingamseonsa (眞鑑禪師), built in 888, contains the an epigraph from the Unified Silla Era. There is a phrase on it that says 'Plant incense on the shore (海岸植香)' on the monument of Jingamseonsa (眞鑑禪師), and it conveys its meaning without using the character 'bury (埋)'. As a result of the absence of the character 'bury (埋)' on the stone monument with the name 'Jeongwon', it is not considered as a Maehyangbi (埋香碑). However, there is evidence that the stone monument with the name 'Jeongwon (貞元)' is in fact a Maehyangbi (埋香碑) and it is also in the Geumpyoseok (禁標石; Forbidden Stone) around Gukjangsaeng (國長生) and at the entrance of Dogapsa Temple (道甲寺). The letters written on the gold sign suggest the possibility that the charcoal used to burn incense (香炭) at the royal tombs of King Jeongjo (正祖) was produced around at Dogapsa Temple (道甲寺) in Wolchulsan (月出山). Since the charcoal used to burn incense (香炭) is naturally related to incense (香), it has been shown that the area around Wolchulsan, where Dogapsa Temple is located, has a long history related to incense (香). The letters visible on the stone monument, the record of Dongguk-myungsanggi (東國名山記) in the late Joseon Dynasty, and the letters on the Geompyoseok (禁標石; Forbidden Stone), all show that the stone monument with the name 'Jeongwon (貞元)' is a Maehyangbi (埋香碑). Considering the fact that the earliest Maehyangbi (埋香碑) in existence is the Maehyangbi (埋香碑) in Yeongam (靈巖) Ippam-ri (笠巖里), which has two dates from 1371 at the end of Goryeo and 1410 at the beginning of Joseon, the stone monument with the name 'Jeongwon' which was set up in 786, would be the oldest Maehyangbi (埋香碑) that we know of. In addition, there is a historical significance in that the Maehyangbi (埋香碑) is proven in the record of Dongguk-myungsanggi (東國名山記), a document from the late Joseon period.

Prevalence of Salmonella Species Isolated from Old Hen Delivery Trucks in Korea and Application of Disinfectant for the Reduction of Salmonella Contamination (국내 노계 운반 전용 차량에서의 살모넬라 오염율 및 차량소독에 따른 오염도 감소 효과)

  • Na, Deok-Hwan;Hong, Young-Ho;Yoon, Mi-Young;Park, Eun-Jin;Lim, Tae-Hyun;Jang, Jun-Hyuk;Kim, Byoung-Youn;Lee, Dong-Hun;Song, Chang-Seon
    • Korean Journal of Poultry Science
    • /
    • v.40 no.1
    • /
    • pp.11-16
    • /
    • 2013
  • Salmonella is closely related with human health of modern society which has concern increased in livestock goods consumption as well as give economic damage throughout the chicken industry such as farm, hatchery, slaughter house and processing plant. From 2007 to 2011, this study investigated Salmonella prevalence from 200 old hen delivery trucks which deliver old egg-laying hens and broiler breeders in Korea. The prevalence of Salmonella species was 38.0% in old hen delivery truck. Serogroup C1 was the most frequently detected serogroup of Salmonella, followed by the serogroups D1, C2 and B. A total of 25 serotypes were identified and Salmonella infantis was the most frequently isolated serotype. In addition, we applied disinfectant to old hen delivery truck for the reduction of Salmonella contamination. The disinfectant consists of formaldehyde, glutaladehyde and quaternary ammonium compound was applied to the trucks. Salmonella isolation rate was significantly decreased after disinfection from 38.0% to 7.5%. Disinfectant could not effectively reduce Salmonella contamination at a dilution of 1:200 which is recommended by manufacturer, but Salmonella isolation rate was significantly decreased at a dilution of 1:50. Since old hen delivery truck could be a potential vector to carry Salmonella into farms and abattoirs, chicken delivery truck should be disinfected thoroughly and sufficiently to control contamination of farms and abattoirs.

A Study on the Buyer's Decision Making Models for Introducing Intelligent Online Handmade Services (지능형 온라인 핸드메이드 서비스 도입을 위한 구매자 의사결정모형에 관한 연구)

  • Park, Jong-Won;Yang, Sung-Byung
    • Journal of Intelligence and Information Systems
    • /
    • v.22 no.1
    • /
    • pp.119-138
    • /
    • 2016
  • Since the Industrial Revolution, which made the mass production and mass distribution of standardized goods possible, machine-made (manufactured) products have accounted for the majority of the market. However, in recent years, the phenomenon of purchasing even more expensive handmade products has become a noticeable trend as consumers have started to acknowledge the value of handmade products, such as the craftsman's commitment, belief in their quality and scarcity, and the sense of self-esteem from having them,. Consumer interest in these handmade products has shown explosive growth and has been coupled with the recent development of three-dimensional (3D) printing technologies. Etsy.com is the world's largest online handmade platform. It is no different from any other online platform; it provides an online market where buyers and sellers virtually meet to share information and transact business. However, Etsy.com is different in that shops within this platform only deal with handmade products in a variety of categories, ranging from jewelry to toys. Since its establishment in 2005, despite being limited to handmade products, Etsy.com has enjoyed rapid growth in membership, transaction volume, and revenue. Most recently in April 2015, it raised funds through an initial public offering (IPO) of more than 1.8 billion USD, which demonstrates the huge potential of online handmade platforms. After the success of Etsy.com, various types of online handmade platforms such as Handmade at Amazon, ArtFire, DaWanda, and Craft is ART have emerged and are now competing with each other, at the same time, which has increased the size of the market. According to Deloitte's 2015 holiday survey on which types of gifts the respondents plan to buy during the holiday season, about 16% of U.S. consumers chose "homemade or craft items (e.g., Etsy purchase)," which was the same rate as those for the computer game and shoes categories. This indicates that consumer interests in online handmade platforms will continue to rise in the future. However, this high interest in the market for handmade products and their platforms has not yet led to academic research. Most extant studies have only focused on machine-made products and intelligent services for them. This indicates a lack of studies on handmade products and their intelligent services on virtual platforms. Therefore, this study used signaling theory and prior research on the effects of sellers' characteristics on their performance (e.g., total sales and price premiums) in the buyer-seller relationship to identify the key influencing e-Image factors (e.g., reputation, size, information sharing, and length of relationship). Then, their impacts on the performance of shops within the online handmade platform were empirically examined; the dataset was collected from Etsy.com through the application of web harvesting technology. The results from the structural equation modeling revealed that the reputation, size, and information sharing have significant effects on the total sales, while the reputation and length of relationship influence price premiums. This study extended the online platform research into online handmade platform research by identifying key influencing e-Image factors on within-platform shop's total sales and price premiums based on signaling theory and then performed a statistical investigation. These findings are expected to be a stepping stone for future studies on intelligent online handmade services as well as handmade products themselves. Furthermore, the findings of the study provide online handmade platform operators with practical guidelines on how to implement intelligent online handmade services. They should also help shop managers build their marketing strategies in a more specific and effective manner by suggesting key influencing e-Image factors. The results of this study should contribute to the vitalization of intelligent online handmade services by providing clues on how to maximize within-platform shops' total sales and price premiums.

A Study on Switching Intention of Mobile Telecommunication Service User: Focused on Group Differences Based on Innovativeness (이동통신 서비스 이용자의 전환의도에 관한 연구: 개인 혁신성에 따른 집단 간의 차이를 중심으로)

  • Oh, Jong-Chul;Yoon, Sung-Joon
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.1
    • /
    • pp.9-21
    • /
    • 2009
  • Recently, the researches to explain Switching Behavior through Theory of Planned Behavior have been discovered. Many researches say that System factors of mobile telecommunication service(MTS) is positively associated with Switching Intention. But There is no difference of system factors between mobile telecommunication services because of IT technique Development. Thus, this study investigated whether switching cost and alternative's attractiveness influence switching intention concerning mobile telecommunication service by adopting Theory of Planned Behavior (TPB) as an underlying theoretical premise. The study also attempted to determine the moderating effects of personal innovativeness on switching intention. For these purposes the author has developed several hypotheses as follows: H-1. The switching cost of different MTS is associated with the attitude of MTS which is using. H-2. The switching cost of different MTS is associated with the subjective norm of MTS which is using. H-3. The switching cost of different MTS is associated with the perceived behavior control of MTS which is using. H-4. The alternative's attractiveness of different MTS is associated with the attitude of MTS which is using. H-5. The alternative's attractiveness of different MTS is associated with the subjective norm of MTS which is using. H-6. The alternative's attractiveness of different MTS is associated with the perceived behavior control of MTS which is using. H-7. The switching cost of different MTS is associated with the switching intention. H-8. The alternative's attractiveness of different MTS is associated with the switching intention. H-9. The attitude of MTS is associated with the switching intention. H-10. The subjective norm of MTS is associated with the switching intention. H-11. The perceived behavior control of MTS is associated with the switching intention. H-12. The personal innovativeness has been a moderating effects to switching intention. Data has been collected from 403 respondents for this study using a questionnaire method. The survey for the actual analysis of the research was done and analyzed with the customers who have an experience of using Mobile telecommunication service and the samples were selected among the middle and high school students who live in Seoul area, the university students who live in Seoul, Gyeonggi and Chungcheng Provinces, and the ordinary workers who are working in Seoul and Gyeonggi Province. The survey was done for 23 days from March 28, 2008 through April 12, 2008. The positive analysis was done with SPSS 12.0K statistics package and visual PLS program using the analysis techniques of frequency analysis, reliability analysis, correlation analysis and factor analysis. In addition, structural equation modeling was conducted using AMOS 5.0. The data was analyzed by frequency analysis using SPSS 12.0 and structural equation modeling using AMOS 5.0. The result of the overall model analysis is as follows: Chi-Square=378.306, d.f.=107, p-value=0.0, GFI=.904, AGFI= 0.863, IFI= 0.939, NFI= 0.917, RMSEA= 0.079, TLI= 0.922. The results of the overall model analysis were coherent. The following study results were revealed: First, switching cost was related positively to attitude, subjective norm and perceived behavior control, three components of TPB. Second, alternative's attractiveness was related negatively to subjective norm but positively to perceived behavior control. Third, switching cost and attitude was related negatively to switching intention, while perceived behavior control was related positively to switching intention. Finally, the study found the moderating effects of personal innovativeness on switching intention. Based on the results, the study offers marketing strategic implications for mobile telecommunication service industry.

  • PDF

Assessment of Metabolic Impairment in Alzheimer's Disease with [$^{18}F$]FDG PET: Validity and Role of Simplified Tissue Radioactivity Ratio Analysis (알쯔하이머병에서 양전자방출단층촬영을 이용한 국소뇌포도당대사의 변화에 관한 연구)

  • Kim, Sang-Eun;Na Duk-Lyul;Lee, Jeong-Rim;Choi, Yong;Lee, Kyung-Han;Choe Yearn-Seong;Kim, Doh-Kwan;Kim, Byung-Tae;Lee, Kwang-Ho;Kim, Seung-Tai P.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.299-314
    • /
    • 1996
  • The purpose of the present study was to validate the use of tissue radioactivity ratios instead of regional metabolic rates for the assessment of regional metabolic changes in Alzheimer's disease(AD) with [$^{18}F$]FDG PET and to examine the correlation of ratio indices with the severity of cognitive impairment in AD. Thirty-seven AD Patients(age $68{\pm}9 yrs$, $mean{\pm}s.d.$; 36 probable and 1 definite AD), 28 patients with dementia of non-Alzheimer type(age $66{\pm}7 yrs$), and 17 healthy controls(age $66{\pm}4 yrs$) underwent [$^{18}F$]FDG PET imaging. Two simplified radioactivity ratio indices were calculated from 37-66 min image: region-to-cerebellar radioactivity ratio(RCR) and a composite radioactivity ratio(a ratio of radioactivity in the most typically affected regions over the least typically affected regions: CRR). Local cerebral metabolic rate for glucose(LCMRglu) was also measured using a three-compartment, five-parameter tracer kinetic model. The ratio indices were significantly lower in AD patients than in controls(RCR in temporoparietal cortex, $0.949{\pm}0.136$ vs. $1.238{\pm}0.129$, p=0.0004; RCR in frontal cortex, $1.027{\pm}0.128$ vs. $1.361{\pm}0.151$, p<0.0001; CRR, $0.886{\pm}0.096$ vs. $1.032{\pm}0.042$. p=0.0024). On the RCR analysis, 86% of AD patients showed a pattern of bilateral temporoparietal hypometabolism with or without frontal involvement; hypometabolism was unilateral in 11% of the patients. When bilateral temporoparietal hypometabolism was considered to be suggestive of AD, the sensitivity and specificity of the RCR analysis for the differential diagnosis of AD were 86% and 73%, respectively. The RCR was correlated significantly with the macroparameter K [$K_1k_3/(k_2+k_3)$] (r=0.775, p<0.0001) and LCMRglu(r=0.633, p=0.0002) measured using the kinetic model. In patients with AD, both average RCR of cortical association areas and CRR were correlated with Mini-Mental Status Examination(r=0.565, p=0.0145; r=0.642, p=0.0031, respectively), Clinical Dementia Rating(r=-0.576, p=0.0124; r=-0.591, p=0.0077), and total score of Mattis Dementia Rating Scale (r=0.574, p=0.0648; r=0.737, p=0.0096). There were also significant correlations between memory and language impairments and corresponding regional RCRs. The results suggest that the [$^{18}F$]FDG PET ratio indices, RCR and CRR, reflect global and regional metabolic rates and correlate with the severity of cognitive impairment in AD. The simplified ratio analysis may be clinically useful for the differential diagnosis and serial monitoring of the disease.

  • PDF

Function of the Korean String Indexing System for the Subject Catalog (주제목록을 위한 한국용어열색인 시스템의 기능)

  • Yoon Kooho
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.15
    • /
    • pp.225-266
    • /
    • 1988
  • Various theories and techniques for the subject catalog have been developed since Charles Ammi Cutter first tried to formulate rules for the construction of subject headings in 1876. However, they do not seem to be appropriate to Korean language because the syntax and semantics of Korean language are different from those of English and other European languages. This study therefore attempts to develop a new Korean subject indexing system, namely Korean String Indexing System(KOSIS), in order to increase the use of subject catalogs. For this purpose, advantages and disadvantages between the classed subject catalog nd the alphabetical subject catalog, which are typical subject ca-alogs in libraries, are investigated, and most of remarkable subject indexing systems, in particular the PRECIS developed by the British National Bibliography, are reviewed and analysed. KOSIS is a string indexing based on purely the syntax and semantics of Korean language, even though considerable principles of PRECIS are applied to it. The outlines of KOSIS are as follows: 1) KOSIS is based on the fundamentals of natural language and an ingenious conjunction of human indexing skills and computer capabilities. 2) KOSIS is. 3 string indexing based on the 'principle of context-dependency.' A string of terms organized accoding to his principle shows remarkable affinity with certain patterns of words in ordinary discourse. From that point onward, natural language rather than classificatory terms become the basic model for indexing schemes. 3) KOSIS uses 24 role operators. One or more operators should be allocated to the index string, which is organized manually by the indexer's intellectual work, in order to establish the most explicit syntactic relationship of index terms. 4) Traditionally, a single -line entry format is used in which a subject heading or index entry is presented as a single sequence of words, consisting of the entry terms, plus, in some cases, an extra qualifying term or phrase. But KOSIS employs a two-line entry format which contains three basic positions for the production of index entries. The 'lead' serves as the user's access point, the 'display' contains those terms which are themselves context dependent on the lead, 'qualifier' sets the lead term into its wider context. 5) Each of the KOSIS entries is co-extensive with the initial subject statement prepared by the indexer, since it displays all the subject specificities. Compound terms are always presented in their natural language order. Inverted headings are not produced in KOSIS. Consequently, the precision ratio of information retrieval can be increased. 6) KOSIS uses 5 relational codes for the system of references among semantically related terms. Semantically related terms are handled by a different set of routines, leading to the production of 'See' and 'See also' references. 7) KOSIS was riginally developed for a classified catalog system which requires a subject index, that is an index -which 'trans-lates' subject index, that is, an index which 'translates' subjects expressed in natural language into the appropriate classification numbers. However, KOSIS can also be us d for a dictionary catalog system. Accordingly, KOSIS strings can be manipulated to produce either appropriate subject indexes for a classified catalog system, or acceptable subject headings for a dictionary catalog system. 8) KOSIS is able to maintain a constistency of index entries and cross references by means of a routine identification of the established index strings and reference system. For this purpose, an individual Subject Indicator Number and Reference Indicator Number is allocated to each new index strings and new index terms, respectively. can produce all the index entries, cross references, and authority cards by means of either manual or mechanical methods. Thus, detailed algorithms for the machine-production of various outputs are provided for the institutions which can use computer facilities.

  • PDF

A study on the incidence of anemia according to feeding patterns and the status of weaning diet (수유 방법에 따른 빈혈의 빈도 및 이유식이에 대한 조사)

  • Kim, Hyun-Ji;Shin, Mee-Yong;Kim, Sung-Shin;Park, Jae-Ock;Kim, Chang-Hwi
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.8
    • /
    • pp.875-880
    • /
    • 2009
  • Purpose : Iron-deficiency anemia remains the most common nutritional deficiency in young infants. This study aimed to survey the actual condition of feeding patterns and weaning diet and to study the association between these factors and the prevalence of anemia in infants aged over 9 months. Methods : We studied 171 infants aged 9-24 months who were hospitalized in the general ward with mild to moderate acute illnesses. The mothers answered a questionnaire about the feeding patterns and the status of the weaning diet of their infants. The infants were divided into three groups: infants who were exclusively breast-fed, those who had been given mixed feeding, and artificial milk feeders. Results : The incidence of anemia was significantly higher in exclusively breast-fed infants (23/68, 33.8%) than in the infants with mixed feeding (11/62, 17.7%) and artificial milk feeders (5/41, 12.1%). The mothers' awareness about the state of their infants󰡑 weaning diet was not related to the presence of anemia in the exclusively breast-fed infants. About 70% of the infants had started the weaning diet before age 6 months in all three groups, without any difference according to feeding patterns. Conclusion : The incidence of anemia was significantly higher in the breast-fed group than in the other infants. Many mothers of breast-fed infants with anemia also believed that their infants were taking sufficient weaning foods. Therefore, further education of the mothers about iron-rich weaning foods and the importance of iron intake during infancy is needed to prevent anemia, especially in breast-fed infants.