• Title/Summary/Keyword: 2D/3D imaging

Search Result 854, Processing Time 0.028 seconds

Convertible 3D-2D display by use of integral imaging system with plastic fiber array

  • Kim, Young-Min;Choi, Hee-Jin;Cho, Seong-Woo;Kim, Yun-Hee;Kim, Joo-Hwan;Park, Gil-Bae;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1482-1485
    • /
    • 2007
  • A three-dimensional (3D)-two-dimensional (2D) convertible display system using a plastic fiber array is proposed. The proposed system has an advantage of making use of a light source for 3D image from an arbitrary location. The optical efficiency of 3D images in the proposed system is enhanced compared with previous research.

  • PDF

Real 3D Property Integral Imaging NFT Using Optical Encryption

  • Lee, Jaehoon;Cho, Myungjin;Lee, Min-Chul
    • Current Optics and Photonics
    • /
    • v.6 no.6
    • /
    • pp.565-575
    • /
    • 2022
  • In this paper, we propose a non-fungible token (NFT) transaction method that can commercialize the real 3D property and make property sharing possible using the 3D reconstruction technique. In addition, our proposed method enhances the security of NFT copyright and metadata by using optical encryption. In general, a conventional NFT is used for 2D image proprietorial rights. To expand the scope of the use of tokens, many cryptocurrency industries are currently trying to apply tokens to real three-dimensional (3D) property. However, many token markets have an art copyright problem. Many tokens have been minted without considering copyrights. Therefore, tokenizing real property can cause significant social issues. In addition, there are not enough methods to mint 3D real property for NFT commercialization and sharing property tokens. Therefore, we propose a new token management technique to solve these problems using integral imaging and double random phase encryption. To show our system, we conduct a private NFT market using a test blockchain network that can demonstrate the whole NFT transaction process.

Distinction between Intradural and Extradural Aneurysms Involving the Paraclinoid Internal Carotid Artery with T2-Weighted Three-Dimensional Fast Spin-Echo Magnetic Resonance Imaging

  • Lee, Nam;Jung, Jin-Young;Huh, Seung-Kon;Kim, Dong-Joon;Kim, Dong-Ik;Kim, Jin-Na
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.6
    • /
    • pp.437-441
    • /
    • 2010
  • Objective : The precise intra- vs. extradural localization of aneurysms involving the paraclinoid internal carotid artery is critical for the evaluation of patients being considered for aneurysm surgery. The purpose of this study was to investigate the clinical usefulness of T2-weighted threedimensional (3-D) fast spin-echo (FSE) magnetic resonance (MR) imaging in the evaluation of unruptured paraclinoid aneurysms. Methods : Twenty-eight patients with unruptured cerebral aneurysms in their paraclinoid regions were prospectively evaluated using a T2- weighted 3-D FSE MR imaging technique with oblique coronal sections. The MR images were assessed for the location of the cerebral aneurysm in relation to the dural ring and other surrounding anatomic compartments, and were also compared with the surgical or angiographic findings. Results : All 28 aneurysms were identified by T2-weighted 3D FSE MR imaging, which showed the precise anatomic relationships in regards to the subarachnoid space and the surrounding anatomic structures. Consequently, 13 aneurysms were determined to be intradural and the other 15 were deemed extradural as they were confined to the cavernous sinus. Of the 13 aneurysms with intradural locations, three superior hypophyseal artery aneurysms were found to be situated intradurally upon operation. Conclusion : High-resolution T2-weighted 3-D FSE MR imaging is capable of confirming whether a cerebral aneurysm at the paraclinoid region is intradural or extradural, because of the MR imaging's high spatial resolution. The images may help in identifying patients with intradural aneurysms who require treatment, and they also can provide valuable information in the treatment plan for paraclinoid aneurysms.

The Effectiveness of 3D FIESTA (Three Dimensional Fast Imaging Employing Steady-state Acquisition) MRI in Sudden Hearing Loss Patients (돌발성 난청 환자에서 3D FIESTA (three dimensional fast imaging employing steady-state acquisition) MRI의 유용성)

  • Cho, Jae-Hwan;Kim, Hyun-Ju;Park, Cheol-Soo
    • Journal of Digital Contents Society
    • /
    • v.11 no.4
    • /
    • pp.425-431
    • /
    • 2010
  • This study explored the effects and the effectiveness of the new method of 3D FIESTA by making quantitative comparison with the conventional 3D FSE method which is frequently employed on patients with sudden hearing loss in clinical settings. For this study, 3D FSE images acquired with 3.0T MR scanner and T2-weighted axial plane 3D FIESTA images were respectively taken from 40 patients diagnosed with Sensorineural Hearing Loss (SSHL). When obtaining those images, sagittal reconstructions oriented perpendicular to the nerve were performed in order to get sagittal images of both right and left internal auditory canal. The findings showed that both SNR and CNR were higher among the group to whom the 3D FIESTA method was applied than the group to whom the conventional 3D FSE method was applied.

The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D FSPGR T1 Technique and Fat Suppressed Isotropic 3D FSE T1 Technique when Examining MRI of Patient with Triangular Fibrocartilage Complex (TFCC) Tear (삼각 섬유성 연골(TFCC) 손상 환자의 자기공명영상 검사 시 Fat Suppressed 3D FSPGR T1 강조 기법에 대한 Fat Suppressed Isotropic 3D FSE T1 강조 기법의 비교 분석 및 유용성에 관한 평가)

  • Kang, Sung-Jin;Cho, Yong-Keun;Lee, Sung-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.105-114
    • /
    • 2016
  • In this study, For assessment of triangular fibrocartilage complex (TFCC) injury, we acquired images by fat suppressed 3D fast spoiled gradient recalled T1 and fat suppressed Isotropic 3D fast spin echo T1 techniques. For quantitative evaluation, measured signal to noise ratio and contrast to noise ratio and verified statistical significance between two imaging techniques by Mann-Whitney U verification. And for qualitative evaluation, marked 4-grade scoring (0: non diagnostic, 1: poor, 2: adequate, 3: good) on shape of TFCC, artifacts by partial volumes, description of the lesions by two radiologist, verified coincidence between 2 observer using Kappa-value verification. We used 3.0 Tesla MR equipment and 8-channel RF coil for imaging acquisition. As quantitative evaluation results, signal to noise ratio and contrast to noise ratio value of Isotropic 3D fast spin echo T1 technique is higher in every image sections, also between two imaging techniques by Mann-Whitney U verification was statistically significant (p < 0.05). As qualitative results, observer 1, 2 marked a higher grade on Isotropic 3D FSE T1 technique, coincidence verification of evaluation results between two observers by Kappa-value verification was statistically significant (p < 0.05). As a result, during MRI examination on TFCC injury, fat suppressed Isotropic 3D fast spin echo T1 technique is considered offering more useful information about abnormal lesion of TFCC.

Cortical Thickness Estimation Using DIR Imaging with GRAPPA Factor 2 (DIR 영상을 이용한 피질두께 측정: GRAPPA 인자 2를 이용한 비교)

  • Choi, Na-Rae;Nam, Yoon-Ho;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.56-63
    • /
    • 2010
  • Purpose : DIR image is relatively free from susceptibility artifacts therefore, DIR image can make it possible to reliably measure cortical thickness/volume. One drawback of the DIR acquisition is the long scan time to acquire the fully sampled 3D data set. To solve this problem, we applied a parallel imaging method (GRAPPA) and verify the reliability of using the volumetric study. Materials and methods : Six healthy volunteers (3 males and 3 females; age $25.33{\pm}2.25$ years) underwent MRI using the 3D DIR sequence at a 3.0T Siemens Tim Trio MRI scanner. GRAPPA simulation was performed from the fully sampled data set for reduction factor 2. Data reconstruction was performed using MATLAB R2009b. Freesurfer v.4.3.0 was used to evaluate the cortical thickness of the entire brain, and to extract white matter information from the DIR image, Analyze 9.0 was used. The global cortical thickness estimated from the reconstructed image was compared with reference image by using a T-test in SPSS. Results : Although reduced SNR and blurring are observed from the reconstructed image, in terms of segmentation the effect was not so significant. The volumetric result was validated that there were no significant differences in many cortical regions. Conclusion : This study was performed with DIR image for a volumetric MRI study. To solve the long scan time of 3D DIR imaging, we applied GRAPPA algorithm. According to the results, fast imaging can be done with reduction factor 2 with little loss of image quality at 3.0T.