• Title/Summary/Keyword: 250 mm Depth

Search Result 65, Processing Time 0.043 seconds

3D Depth Estimation by a Single Camera (단일 카메라를 이용한 3D 깊이 추정 방법)

  • Kim, Seunggi;Ko, Young Min;Bae, Chulkyun;Kim, Dae Jin
    • Journal of Broadcast Engineering
    • /
    • v.24 no.2
    • /
    • pp.281-291
    • /
    • 2019
  • Depth from defocus estimates the 3D depth by using a phenomenon in which the object in the focal plane of the camera forms a clear image but the object away from the focal plane produces a blurred image. In this paper, algorithms are studied to estimate 3D depth by analyzing the degree of blur of the image taken with a single camera. The optimized object range was obtained by 3D depth estimation derived from depth from defocus using one image of a single camera or two images of different focus of a single camera. For depth estimation using one image, the best performance was achieved using a focal length of 250 mm for both smartphone and DSLR cameras. The depth estimation using two images showed the best 3D depth estimation range when the focal length was set to 150 mm and 250 mm for smartphone camera images and 200 mm and 300 mm for DSLR camera images.

Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator (6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포)

  • Yoon, Joo-Ho;Lee, Chul-Soo;Yum, Ha-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

Response of the Growth and Root Development of Shade Landscape Plants by Slit Ventilation Treatment into Indoor Container (실내용기 내 슬릿(Slit)처리가 내음성 조경식물의 생육과 뿌리발달에 미치는 영향)

  • Ju, Jin-Hee;Han, Jung-Hwa
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.105-112
    • /
    • 2009
  • This study has attempted to facilitate various new technologies related to indoor containers and develop a desirable planting environment after investigating the growth (including root growth) of shade-tolerant landscape plants under slit processing, a natural indoor ventilation system. The following results were found: In terms of the shoot growth of Fatsia japonica in a slit container, no distinctive difference was observed in comparison with the control group. However, growth was good when the container 250mm tall or taller. Therefore, it was verified that optical soil depth is more important than slit processing in shoot growth of Fatsia japonica. In Fatsia japonica root length was observed as follows: Control 2(250mm) > Slit 2(250mm) > Control 1(195mm) > Slit 3(360mm) > Control 3(360mm) > Slit 1(195mm). The largest growth was observed in Control 2(250mm), which had no slit processing. In term of root width, this was lower than the initial value in all groups, which means that the root grew vertically, not horizontally. In terms of plant height of Ophiopogon japonicus, a gradual increase was observed in the control group that had no slit processing. No significant growth was detected in the slit system, however. In terms of shoot number, slit containers were generally higher than the control group. In terms of fresh and dry weights, on the contrary, slit containers were mostly lower than the control group. In Ophiopogon japonicus, root length was observed as follows: Slit 2(250mm) > Slit 1(195mm) > Control 2(250mm) > Control 3(360mm) > Slit 3(360mm) > Control 1(195mm). In Ardisia japonica, slit containers were mostly greater than control group in terms of plant height. The greatest plant height was observed at Slit 2(250mm) instead of Slit 1(195mm) and Slit 3(360mm). Except for plant height and shoot number, however, no significant shoot and root growth was observed. Root length was observed as follows: Slit 2(250mm) > Slit 3(360mm) > Control 3(360mm) > Slit 1(195mm) > Control 2(250mm) > Control 1(195mm). Therefore, root length in slit containers was mostly greater than in the control group. The width of root, however, declined in general.

Physicochemical characterization of two bulk fill composites at different depths

  • Guillermo Grazioli ;Carlos Enrique Cuevas-Suarez ;Leina Nakanishi ;Alejandro Francia;Rafael Ratto de Moraes
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.3
    • /
    • pp.39.1-39.12
    • /
    • 2021
  • Objectives: This study analyzed the physical-chemical behavior of 2 bulk fill resin composites (BFCs; Filtek Bulk Fill [FBF], and Tetric-N-Ceram Bulk Fill [TBF]) used in 2- and 4-mm increments and compared them with a conventional resin composite (Filtek Z250). Materials and Methods: Flexural strength and elastic modulus were evaluated by using a 3-point bending test. Knoop hardness was measured at depth areas 0-1, 1-2, 2-3, and 3-4 mm. The translucency parameter was measured using an optical spectrophotometer. Real-time polymerization kinetics was analyzed using Fourier transform infrared spectroscopy. Results: Flexural strength was similar among the materials, while TBF showed lower elastic modulus (Z250: 6.6 ± 1.3, FBF: 6.4 ± 0.9, TBF: 4.3 ± 1.3). The hardness of Z250 was similar only between 0-1 mm and 1-2 mm. Both BFCs had similar hardness until 2-3 mm, and showed significant decreases at 3-4 mm (FBF: 33.45 ± 1.95 at 0-1 mm to 23.19 ± 4.32 at 3-4 mm, TBF: 23.17 ± 2.51 at 0-1 mm to 15.11 ± 1.94 at 3-4 mm). The BFCs showed higher translucency than Z250. The polymerization kinetics of all the materials were similar at 2-mm increments. At 4-mm, only TBF had a similar degree of conversion compared with 2 mm. Conclusions: The BFCs tested had similar performance compared to the conventional composite when used in up to 2-mm increments. When the increment was thicker, the BFCs were properly polymerized only up to 3 mm.

A Study on the Weldability & Indentation Depth Evaluation of Electrochemical Galvanized Steel Sheet according to the Welding Conditions (전기아연도금 강판의 점용접성에 미치는 용접조건과 압흔깊이에 관한 연구)

  • 정영훈;허우진;백승세;권일현;양성모;유효선
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.162-164
    • /
    • 2003
  • Spot welding, a kind of electric resistance welding, has been used in many fields such as automobile, aircraft, and appliance industry. This paper is to investigate the relationship between tensile shear strength and indentation depth under various welding conditions. The tensile shear strength increases with increasing the welding current in the range of 6-l3kA. The optimum welding conditions were 200∼250kg welding force and 10∼15 cycles welding time at 9kA welding current for EZNCEN. The indentation depth for optimum welding condition was 0.6mm at 9kA welding curent and 200kg welding force, 0.17mm at 9kA welding current and 300kg welding force, 0.19mm at 9kA welding current and 10cycle, 0.17mm at 9kA welding current and 15cycle welding time, respectively.

  • PDF

Computation of stress-deformation of deep beam with openings using finite element method

  • Senthil, K.;Gupta, A.;Singh, S.P.
    • Advances in concrete construction
    • /
    • v.6 no.3
    • /
    • pp.245-268
    • /
    • 2018
  • The numerical investigations have been carried out on deep beam with opening subjected to static monotonic loading to demonstrate the accuracy and effectiveness of the finite element based numerical models. The simulations were carried out through finite element program ABAQUS/CAE and the results thus obtained were validated with the experiments available in literature. Six simply supported beams were modelled with two square openings of 200 and 250 mm sides considered as opening at centre, top and bottom of the beam. In order to define the material behaviour of concrete and reinforcing steel bar the Concrete Damaged Plasticity model and Johnson-Cook material parameters available in literature were employed. The numerical results were compared with the experiments in terms of ultimate failure load, displacement and von-Mises stresses. In addition to that, seventeen beams were simulated under static loading for studying the effect of opening location, size and shape of the opening and depth, span and shear span to depth ratio of the deep beam. In general, the numerical results accurately predicted the pattern of deformation and displacement and found in good agreement with the experiments. It was concluded that the structural response of deep beam was primarily dependent on the degree of interruption of the natural load path. An increase in opening size from 200 to 250 mm size resulted in an average shear strength reduction of 35%. The deep beams having circular openings undergo lesser deflection and thus they are preferable than square openings. An increase in depth from 500 mm to 550 mm resulted in 78% reduced deflection.

Fabrication of the Micro-pump using Stereolithography Technology (Stereolithography 기술을 이용한 마이크로 펌프 제작)

  • Lee, Young-Tae;Seo, Hee-Don
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.232-238
    • /
    • 2001
  • We fabricated micro-pump using stereolithography technology. The pump was fabricated using PZT for its drive and used non-movable valve of diffuser/nozzle concept. Size of the pump chamber is, $14mm{\psi}$, narrow hole of diffuser/nozzle is $0.5mm{\psi}$ and wide hole $1mm{\psi}$ and chamber depth is 1.2mm, respectively. We confirmed its operation at frequency 100Hz, supply voltage $90{\sim}250Vp-p$. As the result of the pump working measurement, when ethanol is used, the pressure head difference between inlet and outlet of the pump is about 53mm in the frequency of 100Hz, 200V of Vp-p.

  • PDF

Effects of canal enlargement and irrigation needle depth on the cleaning of the root canal system at 3 mm from the apex (근관확대 및 세척 주사바늘의 근관 내 위치가 치근단 3 mm 부위의 근관 세정에 미치는 영향)

  • Moon, Ho-Jin;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.24-28
    • /
    • 2012
  • Objectives: The aim of this study was to test the hypothesis, that the effectiveness of irrigation in removing smear layer in the apical third of root canal system is dependent on the depth of placement of the irrigation needle into the root canal and the enlargement size of the canal. Materials and Methods: Eighty sound human lower incisors were divided into eight groups according to the enlargement size (#25, #30, #35 and #40) and the needle penetration depth (3 mm from working length, WL-3 mm and 9 mm from working length, WL-9 mm). Each canal was enlarged to working length with Profile.06 Rotary Ni-Ti files and irrigated with 5.25% NaOCl. Then, each canal received a final irrigation with 3 mL of 3% EDTA for 4 min, followed by 5 mL of 5.25% NaOCl at different level (WL-3 mm and WL-9 mm) from working length. Each specimen was prepared for the scanning electron microscope (SEM). Photographs of the 3mm area from the apical constriction of each canal with a magnification of ${\times}250$, ${\times}500$, ${\times}1,000$, ${\times}2,500$ were taken for the final evaluation. Results: Removal of smear layer in WL-3 mm group showed a significantly different effect when the canal was enlarged to larger than #30. There was a significant difference in removing apical smear layer between the needle penetration depth of WL-3 mm and WL-9 mm. Conclusions: Removal of smear layer from the apical portion of root canals was effectively accomplished with apical instrumentation to #35/40 06 taper file and 3 mm needle penetration from the working length.

An Experimental Study on Eccentrically Loaded Steel Fiber Reinforced Concrete Columns (편심축하중을 받는 강섬유보강 콘크리트 기둥의 실험적 연구)

  • 박홍용;안영진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.857-860
    • /
    • 2000
  • An experimental study on the behavior of Steel Fiber Reinforced Concrete Columns under eccentric compression are presented. Forth-one columns were tested; the variables were column type, eccentricity of load, fiber contents, and longitudinal reinforcement ratio. The column size was $250\times160$ mm in cross section with an effective length of 1150 mm. Eccentricity of load was varied in the range from 1/6 to 1/2 times the column depth. This paper is to provides a framework for basic understanding of the steel fiber concrete columns.

A STUDY ON THE EFFECT OF POLYMERIZATION SHRINKAGE OF SEVERAL COMPOSITE RESIN USING STRAIN GAUGE (스트레인 게이지를 이용한 수종 수복재의 중합수축 영향 평가)

  • Lee, In-Cheon;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.20-29
    • /
    • 2009
  • This study was performed to evaluate the effect of the shrinkage stress induced by polymerization process of several light curing filling materials according to filling methods. High power light curing unit which has a plasma arc lamp was used and filling materials used were Filtek $Z-250^{(R)}$ composite resin, $Dyract^{(R)}$ AP compomer and $Tetric^{(R)}$ Flow flowable composite resin. Cavities were prepared on the permanent molars with width 3 mm, height 3 mm and depth 1.5 mm and the filling materials were filled with 1 step, 2 step layering technique and 3 step oblique filling methods. The results can be summarized as follows; 1. Strain values showed rapid increase from the start of light curing followed by gradual decrease afterwards with time. 2. Although the shrinkage stress value of $Z-250^{(R)}$ were shown to be relatively higher than $Dyract^{(R)}$ AP and $Tetric^{(R)}$ Flow, no statistically significant could be found between tested materials(p>0.05). 3. There were no statistically significant difference between 3 filling methods when using $Dyract^{(R)}$ AP and $Z-250^{(R)}$(p>0.05). 4. There were no statistically significant difference between shrinkage stress values obtained from samples prepared by different filling methods and materials(p>0.05).

  • PDF