• Title/Summary/Keyword: 2033

Search Result 79, Processing Time 0.029 seconds

Development on Communication Device with Timeliness Guaranteed for "GIS Preventive and Diagnosis System" (GIS 예방진단 시스템을 위한 정시간성 보장형 통신기기 개발)

  • Min, B.W.;Park, C.S.;Myoung, H.C.;Choi, H.W.;Kim, J.H.;Lee, B.H.;Park, D.H.;Kim, Y.K.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2032-2033
    • /
    • 2007
  • There has been increasing interests of condition monitoring and diagnosis for electric equipment, which lead to the development of this system domestic and abroad. In the past, operators' interest was how to quickly repair and restore the electric equipments after failure. But, due to the North American Blackout in 2003 and the aging of equipments, users have paid attention to the condition based monitoring of electric equipment to prevent a fault like outrage. GIS-PDS("GIS Preventive and Diagnosis System") requiresa large amount of measurement data with timeliness for monitoring and analysis of real-time state of GIS(Gas Insulated Switchgear). We developed the timeliness-guaranteed communication device for GIS-PDS.

  • PDF

Osteocutaneous Turn-Up Fillet Flaps: A Spare-Parts Orthoplastic Surgery Option for a Functional Posttraumatic Below-Knee Amputation

  • Harry Burton;Alexios Dimitrios Iliadis;Neil Jones;Aaron Saini;Nicola Bystrzonowski;Alexandros Vris;Georgios Pafitanis
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.501-506
    • /
    • 2023
  • This article portrays the authors' experience with a complex lower limb bone and soft tissue defect, following chronic osteomyelitis and pathological fracture, which was managed by the multidisciplinary orthoplastic team. The decision for functional amputation versus limb salvage was deemed necessary, enhanced by the principles of "spare parts" in reconstructive microsurgery. This case describes the successful use of the osteocutaneous distal tibia turn-up fillet flap that allowed "lowering the level of the amputation" from a through knee to a below-knee amputation (BKA) to preserve the knee joint function. We comprehensibly review reports of turn-up flaps which effectively lower the level of amputation, also applying "spare-parts" surgery principles and explore how these concepts refine complex orthoplastic approaches when limb salvage is not possible to enhance function. The osteocutaneous distal tibia turn-up fillet flap is a robust technique for modified BKA reconstructions that provides sufficient bone length to achieve a tough, sensate stump and functional knee joint.

Digital Tomosynthesis versus Conventional Radiography for Evaluating Osteonecrosis of the Femoral Head

  • Yun Hwa Roh;Seunghun Lee;Jeong Ah Ryu;Yeo Ju Kim;Yeesuk Kim;Jiyoon Bae
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.2026-2033
    • /
    • 2021
  • Objective: The aim of this study was to compare the diagnostic performances of digital tomosynthesis (DTS) and conventional radiography in detecting osteonecrosis of the femoral head (ONFH) using computed tomography (CT), as the reference standard and evaluate the diagnostic reproducibility of DTS. Materials and Methods: Forty-five patients (24 male and 21 female; age range, 25-77 years) with clinically suspected ONFH underwent anteroposterior radiography, DTS, and CT. Two musculoskeletal radiologists independently evaluated the presence and type of ONFH. The diagnostic performance of radiography and DTS in detecting the presence of ONFH and determining the types of ONFH were evaluated. The interobserver and intraobserver reliabilities of each imaging modality were analyzed using Cohen's kappa. Results: DTS had higher sensitivity (89.4%-100% vs. 74.5%-76.6%) and specificity (97.3%-100% vs. 78.4%-83.8%) for ONFH detection than radiography. DTS showed higher performance than radiography in identifying the subtypes of ONFH with statistical significance in one reader (type 1, 100% vs. 30.8%, p = 0.004; type II, 97.1% vs. 73.5%, p = 0.008). The interobserver agreement was excellent for DTS and moderate for radiography (kappa of 0.86 vs. 0.57, respectively). The intraobserver agreement for DTS was higher than that of radiography (kappa of 0.96 vs. 0.69, respectively). Conclusion: DTS showed higher diagnostic performance and reproducibility than radiography in detecting ONFH. DTS may be used as a first-line diagnostic modality instead of radiography for patients suspected of having ONFH.

Analysis on Probable Rainfall Intensity in Kyungpook Province (경북지방(慶北地方)의 확률(確率) 강우강도(降雨强度)에 대(對)한 분석(分析))

  • Suh, Seung Duk;Park, Seung Young
    • Current Research on Agriculture and Life Sciences
    • /
    • v.4
    • /
    • pp.77-86
    • /
    • 1986
  • The purpose of this study is to estimate an optimum formula of rainfall intensity on basis of the characteristics for short period of rainfall duration in Kyungpook province for the design of urban sewerage and small basin drain system. Results studied are as follows; 1. The optimum method for Taegu and Pohang, Iwai's and Gumbel-Chow's method are recommended respectively. 2. The opotimum type of rainfall intensity for these area, $I=\frac{a}{\sqrt{t}+b}$ (Japanese type), is confirmed with 2.52~4.17 and 1.86~4.54 as a standard deviation for Taegu and Pohang respectively. The optimum formula of rainfall intensity are as follows. Taegu : T : 200 year - $I=\frac{824}{\sqrt{t}+1.5414}$ T : 100 year - $I=\frac{751}{\sqrt{t}+1.4902}$ T : 50 year - $I=\frac{678}{\sqrt{t}+1.4437}$ T : 30 year - $I=\frac{623}{\sqrt{t}+1.4017}$ T : 20 year - $I=\frac{580}{\sqrt{t}+1.3721}$ T : 10 year - $I=\frac{502}{\sqrt{t}+1.3145}$ T : 5 year - $I=\frac{418}{\sqrt{t}+1.2515}$ Pohang : T : 200 year - $I=\frac{468}{\sqrt{t}+1.1468}$ T : 100 year - $I=\frac{429}{\sqrt{t}+1.1605}$ T : 50 year - $I=\frac{391}{\sqrt{t}+1.1852}$ T : 30 year - $I=\frac{362}{\sqrt{t}+1.2033}$ T : 20 year - $I=\frac{339}{\sqrt{t}+1.2229}$ T : 10 year - $I=\frac{299}{\sqrt{t}+1.2578}$ T : 5 year - $I=\frac{257}{\sqrt{t}+1.3026}$ 3. Significant I.D.F. curves derived should be applied to estimate a suitable rainfall intensity and rainfall duration.

  • PDF

SNP Discovery in the Leptin Promoter Gene and Association with Meat Quality and Carcass Traits in Korean Cattle

  • Chung, E.R.;Shin, S.C.;Shin, K.H.;Chung, K.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.12
    • /
    • pp.1689-1695
    • /
    • 2008
  • Leptin, the hormone product of the obese gene, is secreted predominately from white adipose tissue and regulates feed intake, energy metabolism and body composition. It has been considered a candidate gene for performance, carcass and meat quality traits in beef cattle. The objective of this study was to identify SNPs in the promoter region of the leptin gene and to evaluate the possible association of the SNP genotypes with carcass and meat quality traits in Korean cattle. We identified a total of 25 SNPs in the promoter region (1,208-3,049 bp upstream from the transcription start site) of the leptin gene, eleven (g.1508C>G, g.1540G>A, g.1545G>A, g.1551C>T, g.1746T>G, g.1798ins(G), g.1932del(T), g.1933del(T), g.1934del(T), g.1993C>T and g.2033C>T) of which have not been reported previously. Their sequences were deposited in GenBank database with accession number DQ202319. Genotyping of the SNPs located at positions g.2418C>G and g.2423G>A within the promoter region was performed by direct sequencing and PCR-SSCP method to investigate the effects of SNP genotypes on carcass and meat quality traits in Korean cattle. The SNP and SSCP genotypes from the two mutations of the leptin promoter were shown to be associated with the BF trait. The average BF value of animals with heterozygous SNP genotype was significantly greater than that of animals with the homozygous SNP genotypes for the g.2418C>G and g.2423G>A SNPs (p<0.05). Analysis of the combined genotype effect in both SNPs showed that animals with the AC SSCP genotype had higher BF value than animals with BB or AA SSCP genotypes (p<0.05). These results suggest that SNP of the leptin promoter region may be useful markers for selection of economic traits in Korean cattle.

Sediment Preference and Growth of the Young Urechis unicinctus (개불, Urechis unicinctus 치충의 저질선택성 및 성장)

  • 강경호;김재민
    • Journal of Aquaculture
    • /
    • v.16 no.1
    • /
    • pp.24-30
    • /
    • 2003
  • Studies of the seed production of Urechis unicinctus were conducted under the laboratory conditions to obtain some information for the U.unicinitus culture. The experiment included developmental studies of the egg development, larval culture, sediment preference and growth of young U.unicinctus. The experiment were conducted from March to August, 2000. The adults of U.unicinctus collected in Namhae-do, Korea. The developments of the fertilized eggs were observed under a light-microscope at intervals of one hour after containing with density of one individual per 1 $m\ell$. The larvae were fed with Phaeodactylum tricornutum cultured at the laboratory. The concentration of the phytoplankton for the feed was 30,000 cells per individual larva. With progress of development, the food concentration was gradually increased, up to 10,000 cells per individual for the young U.unicinctus. Trochophore larvae appeared on the 68 hours after hatching. On the 32 days after hatching, over 50% of fertilized eggs developed into young U.unicinctus. In order to investigate the effect of sediment on the growth and burrowing of U.unicinctus, the young worms were reared in tanks with different grain sizes. The highest value of sediment preference and survival rate of U.unicinctus was shown in the mixture sediment group with below 0.10 mm, 1.01∼12.00 mm, over 3.01 mm and shell. The lowest value in both sediment preference and survival rate of U.unicinctus was observed in 1.0l∼2.00 mm grain size.

Physiological effect induced by relaxation aroma (이완 유도 향으로 발생된 생리적 효과)

  • 백은주;이윤영;문창현;전병배;양해주
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.233-237
    • /
    • 1999
  • Aromatherapy는 향을 이용하여 생리적 및 심리적 효과를 나타내는 치료법이다. 향의 종류에 따라 여러 효과들이 나타나고 있는데 본 연구에서는 이완 유도향 제품을 개발하기 위해 자율신경계로부터의 신호인 Galvanic skin resistance(GSR), 피부온도, 심박수 등과 뇌파에서의 변화를 측정하여 이완의 정도를 측정하고자 하였다. 실험방법은 4 종류의 aromatherapy용으로 조제된 복합향(#2033, #2026, #11, #13)을 이용하고 피검자는 후각기능이 정상이며 물리적 및 심리적 stress가 없고, 음주, 담배를 3일전까지 경험이 없는 군을 택하였다. 향을 주는 시간은 1분으로 하였으며 순서에 의한 효과를 없애기 위해 4 종류를 random order에 의해 실시하였다. 대조군으로는 증류수를 이용하여 실험 전, 실험 중, 실험 후에서 각각 측정하였으며 또한 각성효과가 좋은 jasmine과 이완 효과를 보이는 lavender를 같은 protocol로 시행하여 이완의 효과를 비교하였다. 뇌파는 FFT분석에 따라 각 주파수 영역 즉 beta, alpha, theta, delta로 나누어 분석하였다. Jasmine과 lavender의 이완 효과에서는 GSR의 변화와 HRV의 변화를 보고한 바 있다(백,1998). 또한 심리불안 효과와 향 이미지 검사를 동시에 시행하여 주관적지표로 삼았다. 실험 결과에서는 이러한 4 종류의 향은 모두 GSR의 현저한 감소 효과를 보였으며, 심박수와 피부온도의 감소경향을 나타내었다. 자율신경계 반응에 따라 4 종류 향의 이완 효과의 순서를 결정할 수 있었다. 주관적 검사와의 상관관계도 잘 나타났으며 이미지는 이완 정도와 섬세하다 항목이 잘 반영되었다. 뇌파의 변화에서는 의미 있는 변화는 보이지 않았다. 결론적으로 relaxation 효과는 GSR를 비롯한 자율신경계지표에서 잘 반영되었다.^2$=.792가 되었다. 설명되는 누적분산값은 67.18%였다.주관적 평가의 결과와 객관적 평가 결과를 이용해 마직물의 태를 평가하는 산출식을 제시하였다. 태 평가치의 경우 16가지 특성치를 모두 넣는 방법과 stepwise 방법, 또 Kawabatark 사용한 순차적 군 회귀법의 세가지 방법의 회귀식 중 16가지 특성치를 모두 넣는 방법의 결정계수가 가장 높았다.tosterone농도는 107.7$\pm$12.0 pmol/l이었고, 남성의 타액내 농도는 274.2$\pm$22.1 pmol/l이었다. 이상의 결과로 보아 본 연구에서 정립된 EIA 방법은 RIA를 대신하여 소규모의 실험실에서도 활용할 수 있을 것으로 사려된다.또한 상실기 이후 배아에서 합성되며, 발생시기에 따라 그 영향이 다르고 팽창과 부화에 관여하는 것으로 사료된다. 더욱이, 조선의 ${\ulcorner}$구성교육${\lrcorner}$이 조선총독부의 관리하에서 실행되었다는 것을, 당시의 사범학교를 중심으로 한 교육조직을 기술한 문헌에 의해 규명시켰다.nd of letter design which represents -natural objects and was popular at the time of Yukjo Dynasty, and there are some documents of that period left both in Japan and Korea. "Hyojedo" in Korea is supposed to have been influenced by the letter design. Asite- is also considered to have been "Japanese Letter Jobcheso." Therefore, the purpose of this study is to look in

  • PDF

Urease and nitrification inhibitors with pig slurry effects on ammonia and nitrous oxide emissions, nitrate leaching, and nitrogen use efficiency in perennial ryegrass sward

  • Park, Sang Hyun;Lee, Bok Rye;Kim, Tae Hwan
    • Animal Bioscience
    • /
    • v.34 no.12
    • /
    • pp.2023-2033
    • /
    • 2021
  • Objective: The present study was conducted to assess the effect of urease inhibitor (hydroquinone [HQ]) and nitrification inhibitor (dicyandiamide [DCD]) on nitrogen (N) use efficiency of pig slurry for perennial ryegrass regrowth yield and its environmental impacts. Methods: A micro-plot experiment was conducted using pig slurry-urea 15N treated with HQ and/or DCD and applied at a rate of 200 kg N/ha. The flows of N derived from the pig slurry urea to herbage regrowth and soils as well as soil N mineralization were estimated by tracing pig slurry-urea 15N, and the N losses via ammonia (NH3), nitrous oxide (N2O) emission, and nitrate (NO3-) leaching were quantified for a 56 d regrowth of perennial ryegrass (Lolium perenne) sward. Results: Herbage dry matter at the final regrowth at 56 d was significantly higher in the HQ and/or DCD applied plots, with a 24.5% to 42.2% increase in 15N recovery by herbage compared with the control. Significant increases in soil 15N recovery were also observed in the plots applied with the inhibitors, accompanied by the increased N content converted to soil inorganic N (NH4++NO3-) (17.3% to 28.8% higher than that of the control). The estimated loss, which was not accounted for in the herbage-soil system, was lower in the plots applied with the inhibitors (25.6% on average) than that of control (38.0%). Positive effects of urease and/or nitrification inhibitors on reducing N losses to the environment were observed at the final regrowth (56 d), at which cumulative NH3 emission was reduced by 26.8% (on average 3 inhibitor treatments), N2O emission by 50.2% and NO3- leaching by 10.6% compared to those of the control. Conclusion: The proper application of urease and nitrification inhibitors would be an efficient strategy to improve the N use efficiency of pig slurry while mitigating hazardous environmental impacts.

Deep Learning-Based Algorithm for the Detection and Characterization of MRI Safety of Cardiac Implantable Electronic Devices on Chest Radiographs

  • Ue-Hwan Kim;Moon Young Kim;Eun-Ah Park;Whal Lee;Woo-Hyun Lim;Hack-Lyoung Kim;Sohee Oh;Kwang Nam Jin
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1918-1928
    • /
    • 2021
  • Objective: With the recent development of various MRI-conditional cardiac implantable electronic devices (CIEDs), the accurate identification and characterization of CIEDs have become critical when performing MRI in patients with CIEDs. We aimed to develop and evaluate a deep learning-based algorithm (DLA) that performs the detection and characterization of parameters, including MRI safety, of CIEDs on chest radiograph (CR) in a single step and compare its performance with other related algorithms that were recently developed. Materials and Methods: We developed a DLA (X-ray CIED identification [XCID]) using 9912 CRs of 958 patients with 968 CIEDs comprising 26 model groups from 4 manufacturers obtained between 2014 and 2019 from one hospital. The performance of XCID was tested with an external dataset consisting of 2122 CRs obtained from a different hospital and compared with the performance of two other related algorithms recently reported, including PacemakerID (PID) and Pacemaker identification with neural networks (PPMnn). Results: The overall accuracies of XCID for the manufacturer classification, model group identification, and MRI safety characterization using the internal test dataset were 99.7% (992/995), 97.2% (967/995), and 98.9% (984/995), respectively. These were 95.8% (2033/2122), 85.4% (1813/2122), and 92.2% (1956/2122), respectively, with the external test dataset. In the comparative study, the accuracy for the manufacturer classification was 95.0% (152/160) for XCID and 91.3% for PPMnn (146/160), which was significantly higher than that for PID (80.0%,128/160; p < 0.001 for both). XCID demonstrated a higher accuracy (88.1%; 141/160) than PPMnn (80.0%; 128/160) in identifying model groups (p < 0.001). Conclusion: The remarkable and consistent performance of XCID suggests its applicability for detection, manufacturer and model identification, as well as MRI safety characterization of CIED on CRs. Further studies are warranted to guarantee the safe use of XCID in clinical practice.