• 제목/요약/키워드: 2-stage parallel-plate ESP

검색결과 2건 처리시간 0.014초

2단 평행판 전기집진기의 서브마이크론입자 집진성능 개선 연구 (Study on improvement of submicron particle collection performance in 2-stage parallel-plate electrostatic precipitators)

  • 유경훈;오명도;이준식
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.323-332
    • /
    • 1997
  • It was reported by some researchers that two-stage parallel-plate ESPs, commonly called electronic air cleaners, show decreasing behavior of collection efficiency as particle size decreases below about $0.03{\mu}m$. This phenomenon is attributed to partial particle charging characteristics, where some of incoming particles are not charged in the charging cell of 2-stage parallel-plate ESP. One way to improve the decreasing collection efficieny in that particle size range is to enforce particle charging quantity in the charging cell. In the present study, in order to do this a 2-wire series-type charging cell modified from a 1-wire normal-type one was suggested and investigated theoretically and experimentally concerning improvement of the collection efficiency. It was confirmed from the experimental and theoretical works that the collection efficiency was apparently improved.

  • PDF

오일 미스트 포집을 위한 저전력 소비형 2단 전기집진기의 집진효율에 대한 연구 (A study on particle collection efficiency of a low power consumption two-stage electrostatic precipitator for oil mists collection)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권7호
    • /
    • pp.834-843
    • /
    • 2014
  • 본 연구에서는 마이크로 탄소 브러쉬 하전부와 평판형 금속 집진부로 구성된 저전력 소비형 2단형 전기집진기를 개발하였고, 특히 인체 위해성이 높은 $0.3{\mu}m$급의 미세한 오일 미스트에 대한 인가전압 및 소비전력별 집진효율 특성을 실험연구를 통해 고찰하였다. 하전부의 인가전압에 따른 단위 입자당 하전율과 입경별 집진효율을 측정함과 동시에 이론에 근거한 계산값과 비교해 보았으며, 9 주 동안의 장시간 운전을 통해 지속적으로 포집된 오일 미스트에 의한 전기집진기의 성능을 열유체역학적인 관점에서 변화를 조사하였다.