• 제목/요약/키워드: 2-stage cycle

검색결과 934건 처리시간 0.035초

하수열을 이용한 냉난방시스템에 관한 연구 (Heating and Cooling System using the Sewage Source Absorption Refrigeration and Heat Pump Cycle)

  • 이용화;신현준;윤희철;박현건
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.19-26
    • /
    • 2007
  • This paper concerns the study of absorption refrigeration and heat pump cycle to use sewage. Simulation analysis on the double-effect absorption refrigeration cycle with parallel and two-stage heat pump cycle has been performed. The working fluid is Lithium Bromide and water solution. The absorption refrigeration cycle use sewage as a cooling water for the absorber and condenser, and absorption refrigeration cycle does that as a chilled water for the evaporator of the first stage cycle. And the two-stage cycle consists of coupling double-effect with parallel and single effect cycle so that the first stage absorber and condenser produces heating water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as a absorber temperature on the coefficient of performance have been studied for absorption refrigeration and heat pump cycle.

가정생활주기에 따른 농가경제 분석 (An Analysis of Farm household Economy by Family Life Cycle)

  • 최현자;최은숙
    • 가정과삶의질연구
    • /
    • 제4권2호
    • /
    • pp.35-51
    • /
    • 1986
  • The purpose of this study is to establish family life cycle of farm and to analyze changes of economic conditions-income, consumption expenditures, savings, assets, and debts-in farm household according to the family life cycle. Income, consumption expenditures, savings, assets, and debts functions are also estimated by age of household head. The data of Farm Household Economy Survey which was conducted in 1983 by Ministry of Agriculture and Fisheries is used in this study. Among total data of 2000, 1603 are analyzed for mean, percentage, and regression using CRISP Program at Office of Rural Development. The results of study can be summarized as follows; 1) Eight stages of family life cycle of farm are established according to the growth of the first child. They are: Establishment stage, Child bearing and preschool stage, Elementary school stage, Middle and high school stage, College and vocational adjustment stage, Period of children's marriage, Re-adjustment stage, and isorganizing stage. 2) The economic conditions of farm household are significantly fluctuated by family life cycle. Among the eight stages, stage Ⅱ is considered relatively comfortable living period and stage Ⅲ, Ⅳ are the most difficult periods of farm household economy. 3) The estimated functions of income, consumption expenditures, savings, assets, and debts by age of household head are as follows; Y(income) = 2, 354, 832+98,456T-1,036T2(F=11.746) C(consumption expenditures) = 81,876+154,976T-1,552T2 (F=37.272) S(savings) = 2,272,956+56,511T+516T2(F=4.262) D(debts) = 903,929+28,300T-438T2(F=3.339) A(assets) = 200,816+1,213,336T-12,930T2(F=21.069) To carry on a reasonable farm household management, a suitable measure to cope with the desire of family and the economic conditions of farm household should be prepared.

  • PDF

한우(韓牛)의 정자발생(精子發生)에 관한 연구(硏究) (Studies on Spermatogenesis in Korean Native Cattle)

  • 이재홍;이성호;박영석
    • 대한수의학회지
    • /
    • 제26권2호
    • /
    • pp.201-210
    • /
    • 1986
  • The cycle of the seminiferous epithelia in the testis of mature Korean native cattle was divided into twelve stages, using criteria the morphological changes in the acrosomic system and the nuclei of developing spematids and germ cells. The results were summarized as follows; 1. The minimum number of tripe A spermatogonia were the average of 1.8 in both at stages I and VI, while maximum numbers were the average of 4.2 at stage XII. Some type A spermatogonia divided at stage XII to produce the type intermediate(IN) spermatogonia at following stage I. The intermediate type spermatogonia divided at stage IV to produce the type B spermatogonia at stage V. 2. The type B spermatogonia divided at stage VII to produce the preleptotene primary spermatocytes at stage XII. The pachytene primary spermatocytes divided at stage XI to produce the secondary spermatocytes at stage VII. The secondary spermatocytes observed at stag XII divided to give rise to the round spermatids at following stage I. Each numbers of the first spermatocytes and of spermatids were almost constant, respectively, through the cycle of the seminiferous epitherium. 3. The relative frequencies of each stage among stages I to XII of the cycle of the seminiferous epithelia were 6.1, 3.7, 5.2, 7.8, 2.2. 3.3, 13.8, 18.4, 11.8, 7.2, 18.1% and 2.4%, respectively.

  • PDF

단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석 (Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System)

  • ;박성룡
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

2단 Gifford-McMahon 극저온냉동기의 특성실험 (An Experimental Study of the 2-stage Gifford-McMahon Cryorefrigerator)

  • 박성제;고득용;유창종;김의준;최헌오
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.198-206
    • /
    • 1993
  • Experimental results of two stage Gifford-McMahon cryorefrigerator are described. In-prototype experiments, drive mechanism is Scotch Yoke type driven by stepping motor, copper meshes and lead balls are used for regenerator's materials in the first stage and the second stage, respectively. To find optimal conditions of the cryopump, no load temperature and refrigeration capacity according to the variation of cycle frequency and operating pressure are measured, and the cool down and load characteristics at particular cycle frequencies are presented. In general, as the cycle frequency is lowered, no load temperature is dropped but refrigeration capacity is diminished. As the representative result, in a case that the cycle frequency is 70rpm and steady state pressure is 14 atm, no load temperature of second stage is lowered to 10.5K in 55 minuters, and in this situation the refrigeration capacity of the first stage is 42W at 80K, that of the second stage is 11 W at 20K.

  • PDF

3단압축 드라이아이스 제조사이클의 압축동력과 엑서지 해석 (Compression Power and Exergy Analysis in a Dry Ice Production Cycle with 3-stage Compression)

  • 이근식
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.550-560
    • /
    • 2000
  • In order to minimize compression power and analyze the cause of exergy loss for a dry ice production cycle with 3-stage compression, the variation of compression power was investigated and the exergy analysis was peformed for the cycle. In this cycle, $CO_2$, is used both as a refrigerant and as a raw material for dry ice. The behavior of compression power and irreversibility in the cycle were examined as a function of intermediate pressure. From this result, the conditions for the minimum compression power were obtained in terms of the first stage or the third stage pressure. In addition, the irreversibilities for the cycle were investigated with respect to the efficiency of compressor. Result shows that the optimum pressure is not consistent with the conventional pressure obtained from the equal-pressure-ratio assumption. This is mainly due to the change in mass flow rate of the intermediate stage compressor by the flash gas evaporation from the flash drums. Most important is that the present exergy analysis enabled us to find bad performance components for the cycle and informed us of methods to improve the cycle performance.

  • PDF

$CO_2$용 2단압축 1단팽창 냉동 사이클의 성능 분석 (Performance Analysis of a Carbon Dioxide(R744) Two-Stage Compression and One-Stage Expansion Refrigeration Cycle)

  • 노건상;손창효
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.70-75
    • /
    • 2009
  • In this paper, cycle performance analysis of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature in the carbon dioxide two-stage refrigeration cycle. The main results were summarized as follows : The cooling capacity of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, compressor efficiency and gas cooling pressure, but decreases with the increasing mass flowrate ratio and evaporating temperature. The compression work of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, outlet temperature of gas cooler, gas cooling pressure and evaporating temperature, but decreases with the increasing compressor efficiency and mass flowrate ratio. The COP of two-stage compression and one-stage expansion refrigeration system increases with the increasing compressor efficiency, but decreases with the increasing superheating degree, gas cooling pressure, mass flowrate ratio and evaporating temperature. Therefore, superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system have an effect on the cooling capacity, compressor work and COP of this system.

  • PDF

EES를 이용한 대체냉매 작동 2단압축냉동사이클의 성능해석 (Two-Stage compression cycle operating with alternative refrigerant using by EES program)

  • 박천완;이동규;최승길;강채동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.533-538
    • /
    • 2009
  • The present study has been conducted to an analysis of two stage refrigeration cycle with alternative refrigerant R410A. In the analysis, single stage cycle (R22 and R410A) compared to COP changing with supercooling degree. Secondly, two stage refrigeration cycle is investigated to the existence of intercooler or supercooler. At results, supercooler contributes to the increase of cooling capacity and the decrease of COP.

  • PDF

프로판 냉매를 활용한 단일 및 다단 냉동 사이클의 전산모사 비교 연구 (A comparative study on the simulation of single-stage and multi-stage refrigeration cycle using propane as a refrigerant)

  • 노상균
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3327-3335
    • /
    • 2014
  • 본 연구에서는 천연가스의 냉각을 위한 프로판을 냉매로 사용한 단일 및 다단 냉동 사이클에 대한 소요 에너지를 비교하였다. 이를 위해서 천연가스의 온도를$ -37.00^{\circ}C$까지 냉각시키기 위해서 프로판을 냉매로 사용하여 1단 압축 및 2단, 3단, 4단 압축을 이용한 냉동 사이클에 대한 비교 연구를 수행하였다. 전산모사를 위해 한국가스공사로부터 제공받은 천연가스 조성을 적용하였으며, 열역학 모델식으로는 Peng-Robinson 상태방정식을 적용하였다. 냉동기 압축 단수가 증가할수록 응축기의 heatduty는 점점 줄어드는 것을 알 수 있었다. 4단 압축공정의 경우 1단 압축공정에 비해 응축기의 heatduty는 약 20.36% 정도 감소하였으며 냉매의 총 순환 유량은 약 14.53% 감소하였다. 또한 4단 압축공정의 경우 1단 압축공정에 비해 압축기의 총 소요 동력은 약 41.61% 감소함을 알 수 있었다.

한우의 세정관상피주기에 관한 연구 (Studies on the Cycle of the Seminiferous Epithelium in Korean Native Cattle)

  • 한방근;임정택;이재홍;김우권
    • 한국가축번식학회지
    • /
    • 제11권1호
    • /
    • pp.33-41
    • /
    • 1987
  • The cycle of the seminiferous epthelia in the testis of matured Korean Native Cattle was divided into eight stages. The results were summarized as follows: 1. Type A spermatogonia a, pp.ared twice as many at stage 2 as compared to stage 1, while maximum numbers were the average of 2.8 at stage 2. The intermediate and Type B spermatogonia were found during the stage 3 to 8, stage 6 to 8, respectively. The leptolene primary spermatocytes were not observed during the stage 5 to 7, while the pachytene primary spermatocytes were shown the least in number at stage 4, the secondary supermatocytes could be seen only at stage 4 and the round spermatids were not observed at stage 3, 4. 2. The relative frequencies of the eight stages of the cycle of the seminiferous eptithelia were 24.9, 14.2, 19.0, 6.3, 3.7, 7.9, 10.3 and 13.9%, respectively. 3. Some of the nuclei of Sertoli cells transformed from the "parallel" type to the "perpendicular" type. This evolution took place from stage 1 to 5, when the number of "perpendicular" type nuclei reached a peak and the number was decreased in the rest of the stages.sed in the rest of the stages.

  • PDF