• Title/Summary/Keyword: 2-out-of-4 G structure with lockout

Search Result 1, Processing Time 0.023 seconds

Safety Assessment for the Design of Digital Reactor Protection System of Nuclear Power Plant (원자력 발전소 디지털 원자로 보호시스템의 설계에 대한 안전성 평가)

  • Kong, Myung-Bock;Lee, Sang-Yong
    • IE interfaces
    • /
    • v.23 no.1
    • /
    • pp.68-77
    • /
    • 2010
  • Digital reactor protection system which consists of many identical modules, is fault- tolerant to provide high safety. The modules themselves including DSP(digital signal processing) card are also fault-tolerant in nature. This paper assesses the safety for being-designed digital reactor protection system of 2-out-of-4 G structure with lockout. Some interesting design alternatives are compared. Fault tree analysis for assessing system safety is performed by Relex software. The selected reactor protection system fully satisfies EPRIURD stipulation of mean failure time of 50 years.