• Title/Summary/Keyword: 2-hydroxyethyl methacrylate

Search Result 158, Processing Time 0.029 seconds

Effect of Addition Amounts of Hydroxyethyl Methacrylate and Methyl Methacrylate on the Properties of Waterborne Polyurethane-Acrylic Hybrid Solutions (Hydroxyethyl Methacrylate와 Methyl Methacrylate의 첨가량 변화가 수분산 폴리우레탄-아크릴 혼성 용액의 물성에 미치는 영향)

  • Kim, Byung Suk;Yoo, Byung Won;Lee, Myung Goo;Byun, Tae Gang;Song, Ki Chang
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.632-638
    • /
    • 2012
  • Waterborne polyurethane dispersions (PUD) were synthesized from isophorone diisocyanate (IPDI), polycarbonate diol (PCD) and dimethylol propionic acid (DMPA) as starting materials. Subsequently, waterborne polyurethane-acrylic hybrid solutions were prepared by reacting the PUD with different amounts of the mixture of acrylate monomers, HEMA (2-hydroxyethyl methacrylate) and MMA (methyl methacrylate). As a result, the average particle size of waterborne polyurethane-acrylic hybrid solutions was increased with increasing the addition amounts of acrylate monomers. Also, the prepared coating films from waterborne polyurethane-acrylic hybrid solutions showed better abrasion resistance and chemical resistance than those of pure PUD.

Preparation of Waterborne Polyurethane-Acrylic Hybrid Solutions from Different Types of Acrylate Monomers (아크릴 단량체의 종류 변화에 의한 수분산 폴리우레탄-아크릴 혼성 용액의 제조)

  • Kim, Byung Suk;Hong, Min Gi;Yoo, Byung Won;Lee, Myung Goo;Lee, Woo Il;Song, Ki Chang
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.410-416
    • /
    • 2012
  • Waterborne polyurethane dispersions (PUD) were synthesized from isophorone diisocyanate (IPDI), polycarbonate diol (PCD) and dimethylol propionic acid (DMPA) as starting materials. Subsequently, polyurethane-acrylic hybrid solutions were prepared by reacting the PUD with different types of acrylate monomers, such as HEMA (2-hydroxyethyl methacrylate):MMA (methyl methacrylate), HEMA:BA (butylacrylate), HEMA:BMA (butyl methacrylate), HEMA:HEA (2-hydroxyethyl acrylate), HEMA:PETA (pentaerytritol triacrylate) mixture. Also, the effects of acrylate types on the chemical resistance and the abrasion resistance of polyurethane-acrylic hybrid solutions were investigated. The test results showed that the HEMA:MMA mixture had the strongest chemical resistance, while the HEMA:PETA mixture had the strongest abrasion resistance among several types of acrylate mixtures.

\Transport Phenomena of Alkali Metal Chlorides theough Poly(2-Hydroxyethyl Methacrylate) Hydrogel Membrane (Poly(2-Hydroxyethyl Methacrylate) 수화겔 막에 대한 알카리 금속 염화물의 수송현상)

  • Seong, Yong-Gil;Lee, Chun-Gi;Jeon, Mu-Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.123-134
    • /
    • 1987
  • The transport phenomena of alkali metal chlorides through poly(2 hydroxyethyl methacrylate) hydrogel membrane have been studied using electrodialysis. The hydrogel membranes were prepared by the polymerization of 2-hydroxvethyl methacrylate in the presence of 45%(V/V) H2O and ethyleneglycodimethacrylate. The initiator used in the polymerization was azobismethylisobutyrate (AMIB) prepared from azobisiobtyronitrile (AIBN) using Mortimer method. The permeability of alkali metal chlorides such LiCl, NaCl and KCI at 50 voltage was obtained. The permeability of NaCl was also observed at 30, 40, 50, and 60 voltages respectively. The concentration of solutes permeated through the membrane was measurer by flame photometry. The experimental results have been discussed with the comparison of apparent solute molecular size, the self-diffusion coefficient of solutes, the transport number of cations in aqueous solution. These indic aloes that poly(2 hydroxyethyl methacrylate) hydrogel membrane shows a specific selectivity for sodium ion.

  • PDF

THERMAL POLYMERIZATION OF 2-HYDROXYETHYL METHACRYLATE WITH PHENYLSILANS (PHENYLSILANS와 2-HYDROXYETHYL METHACRYLATE의 열중합)

  • Sung, A Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.87-90
    • /
    • 2000
  • Poly(HEMA)s have been used as the optometric material for the preparation of soft contact lens. The bulk thermal polymerization of 2-hydroxyethyl methacrylate (HEMA) with various hydrosilanes such as $phSiH_3$, $phMeSiH_2$, and $ph2SiH_2$ were performed to produce poly(HEMA)s containing phenylsilyl end moeity. It was found for thermal polymerization that while the polymerization yield and polymer molcular weights decreased as the relative phenylsilane concentration increases, the TGA residue yields and the relative intensities of SiH IR stretching bands increased as the relative hydrosilane concentration increases over HEMA. The polymerization yield, molecular weight, and TGA residue for the thermal polymerization were higher than those for the photo polymerization. Thus, the hydrosilanes significantly influence on the polymerization as both chain-initiation and chain-transfer agents.

  • PDF

Radiation-Induced Graft Copolymerization of 2-hydroxyethyl-methacrylate and Styrene onto Polytetrafluoroethylene (불소수지 필름에 2-Hydroxyethyl methacrylate와 스틸렌의 방사선 그라프트 공중합)

  • Nho, Young-Chang;Garnett, J.L.;Dworjanyn, P.A.;Jin, Joon-Ha
    • Applied Chemistry for Engineering
    • /
    • v.3 no.3
    • /
    • pp.491-498
    • /
    • 1992
  • Graft polymerization of 2-hydroxyethyl methacrylate(HEMA) and styrene, from both their binary and unitary systems, onto polytetrafluoroethylene(PTFE) film was investigated by means of the simultaneous ${\gamma}-ray$ induced method. The effect of various parameters such as monomer concentration, dose rate, absorbed dose, HEMA/styrene feed ratios and the type of diluent on the extent of grafting in unitary and binary systems was studied. It was observed that when unitary HEMA was used for grafting, the grafting extent was very slight, whereas when comonomers were used, a good grafting yield could be obtained. Inclusion of sulfuric acid in the monomer solution resulted in enhanced grafting yields.

  • PDF

Synthesis and Application for Ophthalmic Material of Polydimethylsiloxanewith Methacrylate Endgroup (Methacrylate 말단기를 가진 Polydimethylsiloxane의 합성 및 안의료용 소재로의 응용)

  • Ye, Ki-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.335-339
    • /
    • 2009
  • Polydimethylsiloxane (PDMS) with methacrylate endgroup is used as contact lens material with elasticity and high oxygen permeability. PDMS prepolymer with methacrylate endgroup was prepared by reacting PDMS (polydimethylsiloxane) with HEMA (2-hydroxyethyl methacrylate). The HEMA-substituted PDMS prepolymer was then copolymerized using AIBN (azobisisobutyronitrile) with BMA (butyl methacrylate; to increase elasticity and flexibility). The water content, oxygen permeability, and visible-ray transmissibility of the resulting polymer were measured to be 23%, 83% and Dk/t > 50, indicating that the copolymer can be used as a good contact lens material.

Preparation of Anion Exchange Membranes of Cross-linked Poly((vinylbenzyl)trimethylammonium chloride-2-hydroxyethyl methacrylate)/Poly(vinyl alcohol) (가교결합한 Poly((vinylbenzyl)trimethylammonium chloride-2-hydroxyethyl methacrylate)/poly(vinyl alcohol) 음이온 교환막 제조)

  • Kim, Mi-Yang;Kim, Kwang-Je;Kang, Ho
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.621-626
    • /
    • 2010
  • Anion exchange membranes can be used for reverse electrodialysis for electric energy generation, and capacitive deionization for water purification, as well as electrodialysis for desalination. In this study, anion exchange membranes of poly((vinylbenzyl) trimethylammonium chloride-2-hydroxyethyl methacrylate)/poly(vinyl alcohol) were prepared through the polymerization of (vinylbenzyl)trimethylammonium chloride and 2-hydroxyethyl methacrylate in aqueous poly(vinyl alcohol) solutions, esterification with glutaric acid, and cross-linking reaction with glutaraldehyde. We investigated electrochemical properties for the anion exchange membranes prepared according to experimental conditions. Ion exchange capacity and electrical resistance for the membranes were changed with a variation in the monomer ratio in polymerization. Water uptake and conductivity for the membranes decreased with an increase in the content of glutaric acid in esterification. The change in the time of crosslinking reaction with the formed film and glutaraldehyde affected electrochemical properties such as water uptake, conductivity, or transport number for the membranes. Chronopotentiometry and limiting current density for the anion exchange membranes prepared were measured.

The Effect of Crosslinking on the Actuation of Electroactive IPMC Prepared with Fluoroalkyl Methacrylate/Acrylic Acid/HEMA Copolymer (Fluoroalkyl Methacrylate/Acrylic Acid/2-HEMA 공중합체로 제조한 IPMC의 구동 특성에 미치는 가교의 영향)

  • Jeong, Han-Mo;La, Young-Soo
    • Polymer(Korea)
    • /
    • v.29 no.5
    • /
    • pp.463-467
    • /
    • 2005
  • In order to enhance the actuation force of ionic polymer-metal composite (IPMC) made with the acrylic copolymer of fluoroalkyl methacryate, acrylic acie, and 2-hydroxyethyl methacrylate(HEMA), the hydroxy group of HEMA was corsslinked with 1,3-diethoxy-1,1,3,3-tetramethyldisiloxane. The water uptake was reduced and the mechanical strengths and the actuation force of the membrane was improved by crosslinking. However, current and deformation responses of IPMC were decreased by crosslinking.

Characterization and Application for Hydrogel Lens Material of Acrylate Monomers Containing Hydroxyl Group (하이드록시기를 포함한 아크릴레이트계 모노머들의 하이드로젤 친수성 렌즈 소재로의 응용 및 특성)

  • Lee, Min-Jae;Kim, Tae-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.3
    • /
    • pp.181-186
    • /
    • 2016
  • The hydrophilic ophthalmic lens with addition of 2-hydroxyethyl acrylate (HEA), 2-hydroxyethyl methacrylate (HEMA), hydroxypropyl methacrylate (HPMA) and Ag nanoparticles were manufactured. And also, the cross-linker ethylene glycol dimethacrylate (EGDMA) and the initiator azobisisobutyronitrile (AIBN) were used for polymerization. The polymerization of the hydrogel lens material was conducted through thermal polymerization in 100 ℃ for 1h. The optical and physical characteristics of hydrogel lens were evaluated by measuring water content, refractive index and optical transmittance. The water content of sample containing HEA, HEMA and HPMA was in the average of 82.12%, 37.06% and 21.57%, respectively. And also, refractive index of the sample containing HEA, HEMA and HPMA was in the average of 1.3540, 1.4330 and 1.4649, respectively. In case of the optical properties of the sample, the results showed that the near-UV transmittance was 82.67%, 80.32% and 79.83%, and the visible transmittance was 89.72%, 88.24% and 86.89%, respectively. And also, optical transmittance of the sample containing Ag nanoparticles showed that the near-UV transmittance of 10.59% and visible transmittance of 43.74% were obtained. From the results, the molecular length influenced on the water content and refractive index of the polymerized material.

Investigation of bonding properties of denture bases to silicone-based soft denture liner immersed in isobutyl methacrylate and 2-hydroxyethyl methacrylate

  • Akin, Hakan;Tugut, Faik;Mutaf, Burcu;Guney, Umit
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.121-125
    • /
    • 2014
  • PURPOSE. The purpose of this study was to investigate the bonding properties of denture bases to silicone-based soft denture liners immersed in isobutyl methacrylate (iBMA) and 2-hydroxyethyl methacrylate (HEMA) for various lengths of time. MATERIALS AND METHODS. Polymethyl methacrylate (PMMA) test specimens were fabricated (75 mm in length, 12 mm in diameter at the thickest section, and 7 mm at the thinnest section) and then randomly assigned to five groups (n=15); untreated (Group 1), resilient liner immersed in iBMA for 1 minute (Group 2), resilient liner immersed in iBMA for 3 minutes (Group 3), resilient liner immersed in HEMA for 1 minute (Group 4), and resilient liner immersed in HEMA for 3 minutes (Group 5). The resilient liner specimens were processed between 2 PMMA blocks. Bonding strength of the liners to PMMA was compared by tensile test with a universal testing machine at a crosshead speed of 5 mm/min. Data were evaluated by 1-way ANOVA and post hoc Tukey-Kramer multiple comparisons tests (${\alpha}$=0.05). RESULTS. The highest mean value of force was observed in Group 3 specimens. The differences between groups were statistically significant (P<.05), except between Group 1 and Group 4 (P=.063). CONCLUSION. Immersion of silicone-based soft denture liners in iBMA for 3 minutes doubled the tensile bond strength between the silicone soft liner and PMMA denture base materials compared to the control group.