• Title/Summary/Keyword: 2-dimensional measurement

Search Result 921, Processing Time 0.033 seconds

Effect of Horseback Riding on Bone Density of the Senior Citizen (승마가 노인의 골밀도에 미치는 영향)

  • Kim, Seon-Chil;Lee, Jong-Ha;Kim, Shin-Gyun;Cho, Sung-Hyoun
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • This study is intended to identify how horseback riding affect the bone density of the elderly. A total of 31 normal senior citizens participated in the research, who were randomly divided into two groups: 15 in horseback riding exercise group and 16 in horseback riding machine exercise group. A horseback riding exercise program was carried out for 25 minutes twice a week for 12 weeks. A pre-test was conducted before starting the program and two post-tests were conducted 6 weeks and 12 weeks after exercises in the same way as the pre-test. Measured items were bone density of lumbar vertebrae and femur. In order to identify the changes in measurement variables before exercises and 6 weeks and 12 weeks after exercises, two-way repeated analysis of variance were used. The comparison of changes in the bone density in both groups revealed that there were significant differences in lumbar vertebrae L3, L4, femur trochanter in both groups over time. This study suggests that three-dimensional movements of horses through horseback riding exercises induce normal movements of senior citizens, providing positive effects on their bone density. If appropriate horse riding exercise programs are used considering the health status, time and economic conditions, and preferences of senior citizens, it would improve their quality of life.

The Discharge Measurement of Tancheon using LSPIV (LSPIV기법을 이용한 탄천(대곡교) 유량측정)

  • Kim, Seo-Jun;Yoon, Byung-Man;Yu, Kwon-Kyu;Joo, Yong-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.911-915
    • /
    • 2007
  • 영상측정기법을 적용하여 경제적이고 효율적인 유속 측정 방법에 대하여 많은 연구들이 진행되어 왔다. 현재 이동식 LSPIV 시스템은 실험실의 수리모형실험과 현장의 국부적인 유속측정에 효율적으로 이용되고 있지만, 고정식 LSPIV 시스템의 적용에는 많은 문제점들이 있어서 현장 적용이 미루어져왔다. 고정식 LSPIV 시스템은 수문분석에 많이 의존하고 있는 현재의 홍수량 산정에 좀 더 정확한 유속과 수위를 동시에 고려할 수 있는 하천유량측정 시스템이다. 이는 과거 하천유량측정 시 많은 비용과 인력 그리고 위험성들을 대폭 줄일 수 있는 현장 모니터링 시스템의 구축을 가능하게 해줄 수 있다. 본 연구에서는 LSPIV (Large Scale Particle Image Velocimetry) 시스템을 탄천(대곡교)에 설치하여 연속적으로 유량 측정을 하였다. 탄천(대곡교)에 적용된 고정식 LSPIV 시스템은 유속측정을 위한 디지털 카메라 2대와 컴퓨터 그리고 수위 측정을 위한 DCU1104 초음파 수위계로 구성된다. 위의 현장 장비들에서 들어온 실시간 영상과 수위자료는 CDMA 무선통신을 이용하여 서버컴퓨터로 들어와서 인터넷에서 손쉽게 받아 볼 수 있다. 이와 같이 실시간으로 들어온 입력 자료는 LSPIV 프로그램을 이용하여 언제 어디에서나 비교적 정확한 유량을 산정할 수 있다. 또한 실시간으로 들어오는 하천 영상을 통해 실시간 현장 모니터링도 가능하게 되고 시간적으로 연속적인 영상을 얻을 수 있기 때문에 하천 유량 변화를 쉽게 알 수 있다. 따라서 과거 현장에서 어렵게 측정하여 얻을 수 있던 유속자료를 간단한 실시간 영상 분석만으로 구할 수 있으므로 앞으로 유량조사에 유용하게 활용될 수 있을 것이다. 입체 영상) 입체영상은 영화에서 시작되었으나, 20c후반기에 들어서면서 애니메이션 분야와 모바일, 광고 패널, 텔레비전등의 매체를 이용한 입체 영상의 개발로 인하여 특정 분야에 한정 시킬 수 없으므로 영상으로 칭한다. 입체 영상은 21c에 들어서면서 영상매체의 한 분야로 급부상하고 있다. 1900년 무렵부터 연구된 입체영화(3-Dimensional motion Picture)는 In여 년이 지난 지금 대중화를 눈앞에 두고 있다. 국내에서는 놀이 동산이나 박물관등에서 흔히 볼 수 있다. 하지만 앞으로는 HDW등의 대중화로 화질의 발전을 이룬 텔레비전 분야 등에서 실용화 될 전망이다. 국제적인 흐름과 함께 국내에서도 입체 영화에 대한 연구가 활성화 되어 영상산업의 한 주류로서 대두되고 있다. 이러한 상황에서 입체영상에 대한 이해와 콘텐츠(Contents)의 개발은 기술적인 진보에 발맞추어 준비되어야 한다. 본 논문은 이러한 기술적인 계보에 발맞춘 영상 콘텐츠 개발에 박차를 가하고자 앞으로의 발전분야에 대한 기술적인 면과 기법적인 면을 제시하여 기술만 앞서고 내용은 수입하는 수입국이기 보다는 미리 준비하여 비전문가나 타국의 기술에 선점 당하지 않는 분야로 성장할 수 있는 진보적인 영상 인들의 관심과 지속적인 연구를 독려하고자 한다.시민의 휴식 및 여가선용 공간으로 활용하기 위한 사업의 기초자료로 활용되며 이미 설계검토가 시작되었다. 본 연구결과는 유수지 및 저수지의 환경개선 사업의 선두적인 성공사례로 국내 타 지역의 유사한 사업에 있어 벤치마킹을 할 수 있는 훌륭한 사례가 될 것이다.요 생산이 증가하자 군신의 변별(辨別)과 사치를 이유로 강력하게 규제하여 백자의 확대와 발전에 걸림돌이 되었다. 둘째, 동

  • PDF

Development of the Measurement Method of Extremely Low Level Activity with Imaging Plate (Imaging Plate를 이용한 극저준위 방사능 측정에 관한 연구)

  • Kwak, Ji-Yeon;Lee, K.B.;Lee, Jong-Man;Park, Tae-Soon;Oh, Pil-Jae;Lee, Min-Kie;Seo, Ji-Suk;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.231-236
    • /
    • 2004
  • An imaging plate(IP) detector, a two-dimensional digital radiation detector that can acquire image of radioactivity distribution in a sample, has been applied in many fields; for industrial radiography, medical diagnosis, X-ray diffraction test, etc. In this study, the possibility of IP detector to be used lot measuring radioactivity of sample is explored using its high sensitivity, higher spatial resolution, wider dynamic range and screen uniformity for several kinds radiations. First, the IP detector is applied to measure the surface uniformity for area source. Surface uniformity is measured rapidly and nondestructively by measuring the radioactivity distribution of common standard area source$(^{241}Am)$. Next, the IP is employed to study the possibility of measuring an extremely low-level activity of environmental sample. For this study the screen uniformity, shield effect of background radiation, linear dynamic range and fading effect of the IP detector is investigated. The potato, banana, radish and carrot samples are chosen to measure ultra low-level activity of $^{40}K$ isotope. The efficiency calibration of IP detector is carried out using the standard source.

Three-dimensional measurement of electron temperature and plasma density in coplanar AC plasma display panels (면방전 AC-PDP에서의 전자온도와 플라스마 밀도의 3차원 진단)

  • Jeong, S.H.;Moon, M.W.;Park, W.B.;Lee, J.H.;Lim, J.E.;Lee, H.J.;Son, C.G.;Lee, S.B.;Yoo, N.L.;Han, Y.G.;Oh, P.Y.;Ko, B.D.;Jeoung, J.M.;Seo, Yoon-Ho;Cho, Guang-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.139-141
    • /
    • 2005
  • 이번 실험에서는 변방전형 교류 PDP에서의 3차원적인 전자온도와 이온밀도의 측정을 마이크로 랑뮈르 탐침법을 통해 실험적으로 연구하였다. 스테핑 모터에 연결된 마이크로 랑뮈르 탐침은 20um씩 움직이며 탐침에 인가하는 플러스와 마이너스의 직류전압을 통해 I-V곡선을 구할 수 있고 이를 통해서 전자온도와 플라스마 밀도를 구할 수 있다. Ne+Xe(4%) 200Torr의 혼합가스에서 전극의 테두리를 따라(X축) 전자온도 및 플라스마 밀도를 측정한 결과 중앙지점에서와 전극의 경계지역에서 이온밀도는 $7.69{\sim}11.1{\times}10^{11}cm^{-3}$ 까지 측정되었다. 또한 전자온도는 플라스마 밀도와 균형적인 관계에 있다는 것은 주목할 만하다. 전자온도는 전극 사이의 중심에서 가장 적게 1.3 ~ 3.15eV까지 측정되었다. Y축으로 측정했을 경우 이온 밀도와 전자온도는 전극 갭 중앙에서부터 약 80um 떨어진 지점에서 서로 교차하며 증가 및 감소였으며 이온밀도는 $8.3{\sim}11.1{\times}10^{11}cm^{-3}$로 측정되었고 전자온도는 이와 균형적인 관계를 가지고 1.2~1.6eV로 측정되었다. 또한 이러한 특성은 AC PDP 에서 나타나는 줄무늬 현상과 관련이 있는 것으로 보인다. Z축으로 측정했을 경우 약 125um높이에서 가장 높게 측정되었으며 $1.1{\times}10^{12}cm^{-3}$정도로 측정되었다.

  • PDF

Anthropometric Analysis of Frontal Sinus Using 3D CT in Koreans (한국인 성인 남녀에서 3차원 전산화단층촬영술을 이용한 전두동의 형태학적 연구)

  • Shim, Byung-Kwan;Kim, Jun-Hyuk;Shin, Ho-Seong;Lee, Young-Man
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.594-601
    • /
    • 2011
  • Purpose: The frontal sinuses are a pair of triangularly shaped, air-filled chambers lined by mucoperiosteum and located between the inner and outer tables of the frontal bone. Until recently, our understanding of gender variations in craniofacial anatomy has been chiefly built upon anthropometric studies, which typically employ facial surface measurements or plain film radiography. The aim of this study i to determine the sizes of the frontal sinus in both sexes in Koreans. Methods: 95 Korean subjects who underwent maxillofacial 3-Dimensional computed tomography (CT) between January 2009 and December 2009 were enrolled. Frontal sinus dimensions and forehead measurements were taken at midline and at 10, 20, and 30 mm to the left and right of midline using sagittal, coronal, and axial images. The data was analyzed for significant differences between measurements made at the selected points in the frontal sinus, for left to right variations, for gender variations, and for racial differences. Results: The mean thickness of the anterior table ranged from 2.31 to 3.23 mm. Mean anteroposterior depth of the frontal sinus ranged from 7.38 to 9.45 mm and did not vary significantly at any distance from midline. Frontal sinus height was greatest at midline (mean=29.24 mm) and progressively lessened at lateral distances. Mean total width at the level of the supraorbital ridge was 53.66 mm. For all measurements, no significant left to right variation was noted. Comparing the sexes, males were found to have greater dimensions in most frontal sinus measurements, though these differences were only found to be significant at or close to midline. The male forehead was marked by more acute nasofrontal angle ($133.3^{\circ}$ versus $141.6^{\circ}$) and a steeper posterior forehead inclination ($14.9^{\circ}$ versus $7.7^{\circ}$). Conclusion: Using CT imaging, forehead and frontal sinus dimensions have been described. Generally, males had larger overall frontal sinus dimensions. And Korean had similar sized frontal sinus to Caucasian in height and width. But in AP distance Korean had lesser measurement. The result of this study may be helpful in the comprehension of normal size of frontal sinus in Korean.

A Study on the Air Pollution Monitoring Network Algorithm Using Deep Learning (심층신경망 모델을 이용한 대기오염망 자료확정 알고리즘 연구)

  • Lee, Seon-Woo;Yang, Ho-Jun;Lee, Mun-Hyung;Choi, Jung-Moo;Yun, Se-Hwan;Kwon, Jang-Woo;Park, Ji-Hoon;Jung, Dong-Hee;Shin, Hye-Jung
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.11
    • /
    • pp.57-65
    • /
    • 2021
  • We propose a novel method to detect abnormal data of specific symptoms using deep learning in air pollution measurement system. Existing methods generally detect abnomal data by classifying data showing unusual patterns different from the existing time series data. However, these approaches have limitations in detecting specific symptoms. In this paper, we use DeepLab V3+ model mainly used for foreground segmentation of images, whose structure has been changed to handle one-dimensional data. Instead of images, the model receives time-series data from multiple sensors and can detect data showing specific symptoms. In addition, we improve model's performance by reducing the complexity of noisy form time series data by using 'piecewise aggregation approximation'. Through the experimental results, it can be confirmed that anomaly data detection can be performed successfully.

Software Implementation of Welding Bead Defect Detection using Sensor and Image Data (센서 및 영상데이터를 이용한 용접 비드 불량검사 소프트웨어 구현)

  • Lee, Jae Eun;Kim, Young-Bong;Kim, Jong-Nam
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.4
    • /
    • pp.185-192
    • /
    • 2021
  • Various methods have been proposed to determine the defect detection of welding bead, and recently sensor data and image data inspection have been steadily announced. There are advantages that sensor data inspection is highly accurate, and two-dimensional-based image data inspection is able to determine the position of the welding bead. However, when analyzing only with sensor data, it is difficult to determine whether the welding has been performed at the correct position. On the other hand, the image data inspection does not have high accuracy due to noise and measurement errors. In this paper, we propose a method that can complement the shortcomings of each inspection method and increase its advantages to improve accuracy and speed up inspection by fusing sensor data inspection which are average current, average volt, and mixed gas data, and image data inspection methods and is implemented as software. In addition, it is intended to allow users to conveniently and intuitively analyze and grasp the results by performing analysis using a graphical user interface(GUI) and checking the data and inspection results used for the inspection. Sensor inspection is performed using the characteristics of each sensor data, and image data is inspected by applying a morphology geodesic active contour algorithm. The experimental results showed 98% accuracy, and when performing the inspection on the four image data, and sensor data the inspection time was about 1.9 seconds, indicating the performance of software that can be used as a real-time inspector in the welding process.

Evaluation of the correlation between the muscle fat ratio of pork belly and pork shoulder butt using computed tomography scan

  • Sheena Kim;Jeongin Choi;Eun Sol Kim;Gi Beom Keum;Hyunok Doo;Jinok Kwak;Sumin Ryu;Yejin Choi;Sriniwas Pandey;Na Rae Lee;Juyoun Kang;Yujung Lee;Dongjun Kim;Kuk-Hwan Seol;Sun Moon Kang;In-Seon Bae;Soo-Hyun Cho;Hyo Jung Kwon;Samooel Jung;Youngwon Lee;Hyeun Bum Kim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.809-815
    • /
    • 2023
  • This study was conducted to find out the correlation between meat quality and muscle fat ratio in pork part meat (pork belly and shoulder butt) using CT (computed tomography) imaging technique. After 24 hours from slaughter, pork loin and belly were individually prepared from the left semiconductors of 26 pigs for CT measurement. The image obtained from CT scans was checked through the picture archiving and communications system (PACS). The volume of muscle and fat in the pork belly and shoulder butt of cross-sectional images taken by CT was estimated using Vitrea workstation version 7. This assemblage was further processed through Vitrea post-processing software to automatically calculate the volumes (Fig. 1). The volumes were measured in milliliters (mL). In addition to volume calculation, a three-dimensional reconstruction of the organ under consideration was generated. Pearson's correlation coefficient was analyzed to evaluate the relationship by region (pork belly, pork shoulder butt), and statistical processing was performed using GraphPad Prism 8. The muscle-fat ratios of pork belly taken by CT was 1 : 0.86, while that of pork shoulder butt was 1 : 0.37. As a result of CT analysis of the correlation coefficient between pork belly and shoulder butt compared to the muscle-fat ratio, the correlation coefficient was 0.5679 (R2 = 0.3295, p < 0.01). CT imaging provided very good estimates of muscle contents in cuts and in the whole carcass.

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

Airway Responses to Bronchoprovocation Using High-Resolution Computed Tomography in Patients with Bronchial Asthma (기관지천식환자에 있어서 고해상도 전산화단층촬영술을 이용한 기관지유발에 대한 기도의 반응)

  • Choi, Byoung-Whui;Kang, Yoon-Jeong;Ko, Hyung-Ki;Park, In-Won;Hue, Sung-Ho;Kim, Yang-Soo;Kim, Young-Goo;Kim, Kun-Sang;Kim, Jong-Hyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.813-822
    • /
    • 1995
  • Background: Bronchial hyperresponsiveness and abnormal response such as a loss of distensibility are pathophysiologic characteristics if bronchial asthma. The only means of direct in vivo measurement of airway size had been a tantalium bronchography, until high-resolution computed tomography(HRCT) enabled to measure noninvasively two dimensional airway area more accurately and reliably. Method: To investigate airway area responses to bronchial provocation with methacholine and evaluate the major sites of bronchial constriction in patients with bronchial asthma. We examined HRCT scans in five patients with bronchial asthma who had significant bronchoconstriction(20% or more decrease in $FEV_1$) using CT scanner(5,000T CT, Shimadzu Co, Japan) before and in 3~5 min. after methacholine inhalation. Airways which were matched by parenchymal anatomic landmarks in each patient before and after methacholine inhalation were measured using film scanner(TZ-3X scanner; Truvel Co. Chatsworth CA, USA) and a semiautomated region growing method. Results: 1) We identified 9 to 12 airways in each patient which were matched by parenchymal anatomic landmarks before and after methacholine inhalation. 2) Airway responses to methacholine are quite different even in a patient. 3) The constriction of small airways(average diameter <2 mm; area < $3.14mm^2$) was 48.7%(8.3; SEM, n=43), being more prominant than that of large airways(average diameter >2 mm; area > $3.14mm^2$), 53.8% (4.4;SEM, n=10), but not significantly different(p>0.05). 4) There was no significant difference in the degree of constriction between upper(44.3% +5.8; mean + SEM, n=30) and lower lung regions(56.7% +4.5, n=23). Conclusions: Thus airway responses to methacholine bronchoprovocation is quite variable in a patient with bronchial asthma and has no typical pattern in patients with bronchial asthma.

  • PDF