• Title/Summary/Keyword: 2-dimensional measurement

Search Result 923, Processing Time 0.024 seconds

Performance Test of 2-Dimensional PIV and 3-Dimensional PIV using Standard Images (표준화상을 이용한 2차원 PIV와 3차원 PIV계측 및 성능비교검정)

  • Doh, D.H.;Hwang, T.G.;Song, J.S.;Baek, T.S.;Pyun, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.646-651
    • /
    • 2003
  • Quantitative performance test on the conventional 2D-PIV and the hybrid angular 3D-PIV (Stereoscopic PIV) was carried out. LES Data sets on an impinging jet which are provided on the webpage(http://www.vsj.or.jp/piv) for the PIV Standard Project were used for the generation of virtual images. The generated virtual images were used for the 2D-PIV and 3D-PIV measurements. The measurement results showed that the results obtained by 2D-PIV on average values are closer to the LES data than those obtained by 3D-PIV, but the turbulent properties obtained by 2D-PIV are largely underestimated than those obtained by 3D-PIV.

  • PDF

A review on the accuracy assessment methods of 3-dimensional digital dental models (디지털 치과모형의 정확도 평가 방법에 대한 고찰)

  • Park, Ji-Su;Lim, Young-Jun;Lee, Jungwon;Kim, Bongju
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.55-63
    • /
    • 2019
  • The aim of this article was to review various methods used to evaluate the accuracy of digital dental models. When evaluating the accuracy of digital models, the errors can be reduced by educating examiners and using artificial landmarks. The accuracy evaluation methods of digital dental models are divided into linear measurement, 2-dimensional cross-sectional analysis, and 3-dimensional best fit measurement. As the technology of scanners develops, many studies have been conducted to compare the accuracy of digital impression and conventional impression. According to improvement of scan technologies and development of 3-dimensional model analysis software, the ability to evaluate the accuracy of digital models is becoming more efficient. In this article, we describe the methods for evaluating the accuracy of a digital model and investigate effective accuracy analysis methods for each situation.

A Display System of Realtime 3D Bathymetry Using Remote Sensing Exploration and Cloud Computing Technologies (원격탐사와 클라우드 컴퓨팅 기술을 활용한 실시간 3D 해저지형의 디스플레이 시스템)

  • Lee, Jong-Hoon;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.2
    • /
    • pp.152-159
    • /
    • 2014
  • Recently. utilization of remote sensing exploration and cloud computing has been extended to efficient measurement, store, and update of bathymetry map data according to cloud computing technology. In the field of real ocean, water depth measurements and measurement data management, distribution, and display equipment for the development and dissemination have generated a lot of time and cost. To improve these problems, through real-time three-dimensional display system at this location, we can determine the importance of measurement activities, and reduce the time and cost of measurement activities. Data measured from marine probe vessels and remote sensing exploration equipments and other various channels can be handled and managed. In this paper, we propose a realtime three-dimensional display system through the depth measurements from remote sensing exploration. The proposed real-time three-dimensional display system can be effectively applied in the field of measurement of the topographical survey of the land as well as bathymetry of the sea.

Point Cloud Measurement Using Improved Variance Focus Measure Operator

  • Yeni Li;Liang Hou;Yun Chen;Shaoqi Huang
    • Current Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.170-182
    • /
    • 2024
  • The dimensional accuracy and consistency of a dual oil circuit centrifugal fuel nozzle are important for fuel distribution and combustion efficiency in an engine combustion chamber. A point cloud measurement method was proposed to solve the geometric accuracy detection problem for the fuel nozzle. An improved variance focus measure operator was used to extract the depth point cloud. Compared with other traditional sharpness evaluation functions, the improved operator can generate the best evaluation curve, and has the least noise and the shortest calculation time. The experimental results of point cloud slicing measurement show that the best window size is 24 × 24 pixels. In the height measurement experiment of the standard sample block, the relative error is 2.32%, and in the fuel nozzle cone angle measurement experiment, the relative error is 2.46%, which can meet the high precision requirements of a dual oil circuit centrifugal fuel nozzle.

Application of DMD for Phase Shifting in Moire Topology (DMD를 이용한 위상천이 모아레 3차원 형상 측정)

  • Jeong, Kyung-Seok;Jung, Yong-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2457-2462
    • /
    • 2011
  • The need for rapid and accurate measurement of 3-dimensional objects is increasing due to the paradigmatic shift in manufacturing from mass production to small batch production. A three dimensional measurement technique which can provide the dimensional information of the object manufactured or to be manufactured has been developed. This method is based on phase shifting moire topology. Digital-Micromirror-Device (DMD) has been used in generating phase shifting moire fringes. And the mechanically moving optical components used for phase shifting, which might result in measurement errors, have been replaced by the DMD. Inherent $2\pi$-ambiguity problem, occurring in the calculation of phase from the light intensity distribution due to the nature of arctangent function, has been overcome by adapting the phase unwrapping method. The advantage of this technique is the easy change of the range and the resolution of the measurement by simply changing the computer generated grid pattern with the appropriate combination of projection lens of various focal length.

System Design and Camera Calibration of Slit Beam Projection for Maximum Measuring Accuracy (슬릿광 3차원 형상측정에서 측정분해능 최적화를 위한 시스템설계 및 카메라보정)

  • 박현구;김명철;김승우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1182-1191
    • /
    • 1994
  • This paper presents an enhanced method of slit beam projection intended for the rapid measurement of 3-dimensional surface profiles of dies and molds. Special emphasis is given to optimizing the design of optical system so that the measuring accuracy can be maximized by adopting two-plane camera calibration together with sub-pixel image processing techniques. Finally, several measurement examples are discussed to demonstrate that an actual measuring accuracy of $\pm$ 0.2 mm can be achieved over the measuring range of 500 mm{\times}300mm{\times}200mm$.

Profile Measurements of Micro-Machined Surfaces by Scanning Tunneling Microscopy (터널링효과를 이용한 초미세 가공표면의 형상측정)

  • Jung, Seung-Bae;Lee, Young-Ho;Kim, Seung-Woo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.7 s.94
    • /
    • pp.1731-1739
    • /
    • 1993
  • An application of Scanning Tunneling Microscopy(STM) is investigated for the measurement of 3-dimensional profiles of the macro-machined patterns of which critical dimensions lie in the range of submicrometers. Special emphasis of this investigation is given to extending the measuring ranges of STM upto the order of several micrometers while maintaining superb nanometer measuring resolution. This is accomplished by correcting hysteresis effects of piezoelectric actuators by using non-linear compensation models. Detailed aspects of design and control of a prototype measurement system are described with some actual measuring examples in which fine It patterns can successfully be traced with a resolution of 1 nanometer over a surface range of $4{\times}2$ micrometers.

An Intercity Compararive Study of Qual ity of Life in Korea : A Mulit-Year$\cdot$Mulit-Dimensional Diatance Index Model Approach (다년도$\cdot$다차원 거리지표 모형을 이용한 한국 도시의 삶의 질 비교연구)

  • 김재홍;이은우;이재기
    • Journal of the Korean Regional Science Association
    • /
    • v.14 no.1
    • /
    • pp.21-45
    • /
    • 1998
  • Urban quality of life(QOL) is recently considered as the important determinant of inter-urban migration and industrial location chice. However, there is little concensus in the method of measurement of QOL. This study provides an theoretical framework of the measurement of QOL. This study provides an theoretical framework of the measurement of QOL, and developes a new method, a multi-year$\cdot$mulit-dimensional distance index model. Based on the theoretical framework and the method, the QOLs of 74 urban areas in Korea are measured, and the determinants of the QOL and the changes of the QOL between two years of 1993 and 1995 are analyzed. The results of the analysis are as follows: 1) The interurban differences of the QOL tens to be interban differences of the QOL tend to be intensified over time. 2) The OQLs of the cities in the Capital Region are relatively deteriorated. 3) The conditions of education$\cdot$Culture$\cdot$leisure life determiner over 65% of the QOL of the Korean cities.

  • PDF

A TWO-DIMENSIONAL FINITE VOLUME MODEL IN NONORTHOGONAL COORDINATE SYSTEM

  • Kim, Chang-Wan;Lee, Bong-Hee;Cho, Yong-Sik;Yoon, Tae-Hoon
    • Water Engineering Research
    • /
    • v.2 no.3
    • /
    • pp.151-160
    • /
    • 2001
  • A two-dimensional flow model is newly developed. Two-dimensional shallow-water equations are discretized by the finite volume method. A nonorthogonal coordinate system is then employed. The developed model is applied to simulations of flows in a 180 degree curved bend flow. Numerical prediction are compared to available laboratory measurement. A good agreement is observed.

  • PDF