• Title/Summary/Keyword: 2-dimensional measurement

Search Result 921, Processing Time 0.032 seconds

Growth and Structural Characterization of Single Layer Dichalcogenide $MoS_2$

  • Hwang, Jae-Seok;Kang, Dae-Joon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.575-575
    • /
    • 2012
  • Synthesis of novel two dimensional materials has gained tremendous attention recently as they are considered as alternative materials for replacing graphene that suffers from a lack of bandgap, a property that is essential for many applications. Single layer molybdenum disulfide ($MoS_2$) has a direct bandgap (1.8eV) that is promising for use in next-generation optoelectronics and energy harvesting devices. We have successfully grown high quality single layer $MoS_2$ by a facile vapor-solid transport route. As-grown single layer $MoS_2$ was carefully characterized by using X-ray diffraction, Raman spectroscopy, field emission scanning electron microscopy and electrical transport measurement. The results indicate that a high quality single layer $MoS_2$ can be successfully grown on silicon substrate. This may open up great opportunities for the exploration of novel nanoelectronic devices.

  • PDF

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

Effects of Viewing Angle on the Estimation of Joint Angles in the 2-dimensional Plane (2차원 면에서의 자세 관측시 시야각이 관절각 추정에 미치는 영향)

  • Lee, In-Seok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.51-62
    • /
    • 2006
  • In assessing risks related to working posture, pictures of postures are taken from various directions, which can be a source of observation error. Joint postures of the neck, lower back, knee, shoulder, and elbow were taken from 7 different viewing angles and 19 observers estimated joint angles by observing the pictures in 2-dimensional display. The joint angles were also measured using an optoelectronic motion measurement system. The estimation error increased as the viewing angle varies from the right side of the human body, but the patterns differ according to which joint angles were being observed. Guidelines to increase the validity of observation of joint angles were presented based on the results. In general, it is recommended to maintain the viewing angle within 20 degrees from the right side of the human body, while different ranges of viewing angle are recommended for each joint angle.

Unstable Flow in a Vaneless Diffuser of 2-Dimensional Centrifugal Compressor (2차원 원심 압축기의 깃 없는 디퓨저에서의 불안정 유동)

  • Kang, Kyung-Jun;Shin, You-Hwan;Kim, Kwang-Ho;Lee, Yoon-Pyo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.5-11
    • /
    • 2011
  • This study investigated on details of flow characteristics in a vaneless diffuser of a compressor with 2-dimensional impeller at various flow rates. Experiment for a low speed compressor model in a water reservoir was performed to analyze the flow field in the vaneless diffuser and volute casing, which was done by PIV measurement. It was also focused on the periodic flow patterns occurring at low flow rate near unstable operating region of the compressor. At low flow rate condition, the flow visualization clearly shows that the flow energy from impeller is highly accumulated at the compressor exit by the blockage effect of a flow damper and consequently the reverse flow occurs in the diffuser.

Two-dimensional $O_2$ and OH Density Measurement Using Tunable KrF Excimer Laser Light a Combustion Bomb via Planar Laser Induced Predissociative Fluorescence and Laser Rayleigh Scattering (평면 선해리 레이저유도 형광법과 레이래이 분산법을 이용한 연소실내의 OH 및 $O_2$의 2차원적 농도측정)

  • 김경수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.4
    • /
    • pp.91-99
    • /
    • 1994
  • Tunable KrF Excimer Laser is used here for measuring OH and $O_2$ density distribustion in an open $H_2$/air premixed flame and in a combustion bomb. Laser Rayleigh Scattering(LRS) and Planar Laser Induced Predissociative Fluorescence(PLIPF) methods are used to obtain two-dimensional images of total and specific densities. Laser Excitation wavelengths are calibrated via flame images and combustion bomb images show good qualitative a greement with theoretical calculation. Furthermore images in a combustion bomb can be developed to study real Spark-Ignition engine combustions. Our experimental images show that there are no more collisional quenching problem at high pressure environment(including atmospheric pressure) using predissociative fluorescence technique. Further development to obtain two-dimensional temperature dustribution is ready to use eventhough it is not reported in this paper.

  • PDF

A Study on the Possibility of Three-dimensional Wearable Respiration Rate Sensor based on Surface Area Changes (표면적 변화에 기반한 입체적 웨어러블 호흡수 센서의 가능성 탐색)

  • Lee, Seungpyo;Ban, Hyunsung;Lee, Joohyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.35-44
    • /
    • 2018
  • This study suggests the sensing method of the Three-dimensional respiration rate sensor based on surface area changes, and exploring the design direction of the three-dimensional breathing sensor and the design orientation of the garment. To achieve this, two types of three-dimensional respiration rate sensor were produced, and the study of the dummy and the subjects studied. The study I investigated the possibility of measurement of the three-dimensional respiration sensor by the study variables of the sensor type and speed of respiration. The study II proposes a suitable type of sensor for each of the three measuring positions in addition to the study variables in the study I. To evaluate accuracy, reproducibility, and reliability of the three-dimensional respiration rate sensor, the BIOPAC was used to measure the respiration rate simultaneously with the three-dimensional respiration rate sensor. Through all these results of the experiment, it explored the possibility of measurement of the three-dimensional respiration sensor for the dummy. It also proposed a suitable type of sensor by measuring the respiration rate for the human body.

Confocal Microscopy Measurement of the Fiber Orientation in Short Fiber Reinforced Plastics

  • Lee, Kwang Seok;Lee, Seok Won;Youn, Jae Ryoun;Kang, Tae Jin;Chung, Kwansoo
    • Fibers and Polymers
    • /
    • v.2 no.1
    • /
    • pp.163-172
    • /
    • 2001
  • To determine three-dimensional fiber orientation states in injection-molded short fiber composites a CLSM (Confocal Laser Scanning Microscope) is used. Since the CLSM optically sections the composites, more than two cross-sections either on or below the surface of the composite can be obtained. Three dimensional fiber orientation states can be determined with geometric parameters of fibers on two parallel cross-sections. For experiment, carbon fiber reinforced polystyrene is examined by the CLSM. Geometric parameters of fibers are measured by image analysis. In order to compactly describe fiber orientation states, orientation tensors are used. Orientation tensors are determined at different positions of the prepared specimen. Three dimensional orientation states are obtained without the difficulty in determining the out-of-plane angles by utilizing images on two parallel planes acquired by the CLSM. Orientation states are different at different positions and show the shell-core structure along the thickness of the specimen.

  • PDF

Numerical study on flows within an shrouded centrifugal impeller passage (원심회전차 내부유도장에 관한 수치해석적 연구)

  • Kim, Seong-Won;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3272-3281
    • /
    • 1996
  • The flow analysis method which had been developed for the numerical calculation of 3-dimensional, incompressible and turbulent flow within an axial compressor was extended to the flow field within centrifugal impeller. In this method based on the SIMPLE(Semi Implicit Method Pressure Linked Equations) algorithm, the coordinate transformation was adopted and the standard k-.epsilon. model using wall function was used for turbulent flow analysis. The calculated flow fields have agreed very well with measurement results. Especially, 3-dimensional and viscous flow characteristics including secondary flows, jet-wake flow and decreased pressure rise along impeller passage, which can't be predicted by inviscid Q3D calculation were predicted very reasonably.

Measurement of Two Dimensional Magnetic Properties of Electrical Steel Sheets under Rotating Magnetic Fields (전기강판의 회전자계 하에서의 2차원 자계특성 측정)

  • Eum, Young-Hwan;Hong, Sun-Ki;Shin, Pan-Seok;Koh, Chang-Seop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.617-622
    • /
    • 2006
  • It is necessary to measure precisely the magnetic characteristics of electrical steel sheets under rotating magnetic fields, to obtain an accurate numerical performance analysis of electric machines made of electrical steel sheets. In this paper, the two dimensional magnetic characteristics of an electrical steel sheet are measured and explained under rotating magnetic fields using a two-axes-excitation type single sheet tester (SST). Through experiments, the magnetic properties, under rotating magnetic fields, of a non-oriented and grain oriented electrical steel sheet were measured respectively. In addition, the iron losses due to not only the alternating magnetic fields, but also rotating magnetic fields were measured. These experimentally measured results can evidently be applied to the analysis of iron losses in electrical machines.

2-dimensional Measurement of Arterial Pulse by Imaging Devices (촬상소자를 이용한 맥동의 2차원 계측)

  • Kim, Ki-Wang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.8-17
    • /
    • 2008
  • Objectives: For the traditional pulse diagnosis in Oriental Medicine, not only the pulse shape in time domain, but the width, length and depth of arterial pulse also should be measured. However, conventional pulse diagnostic systems have failed to measure the spatial parameters of the arterial pulse e.g. effective length of arterial pulse in the wrist. In fact, there are many ways to measure that kind of spatial features in arterial pulsation, but among them, the method using image sensor provides relatively cheap and simple way, therefore I tested feasibility of measuring 2-dimensional pressure distribution by imaging devices. Methods: Using widely used PC cameras and dotted balloons, the subtle oscillation of skin over the radial artery was recorded continuously, and then the displacement of every dot was calculated. Consequently, the time course of that displacements shows arterial pulse wave. Results: By the proposed method I could get pressure distribution map with 30Hz sampling rate, 21steps quantization resolution, and approximately 1mm spatial resolution. With reduced quantization resolution, $3cm{\times}4cm$ view angle could be achieved. Conclusion: Although this method has some limitations, it would be useful method for detecting 2-dimensional features of arterial pulse, and accordingly, this method provides a novel way to detect 'narrow pulse', 'wide pulse', 'long pulse', 'short pulse', and their derivatives.

  • PDF