• 제목/요약/키워드: 2-axis control

Search Result 728, Processing Time 0.031 seconds

Letrozole, an aromatase inhibitor, improves seminal parameters and hormonal profile in aged endangered Markhoz bucks

  • Rezaei, Ako;Vaziry, Asaad;Farshad, Abbas
    • Animal Bioscience
    • /
    • v.35 no.11
    • /
    • pp.1666-1674
    • /
    • 2022
  • Objective: Letrozole, a potent aromatase inhibitor, is known to have the potential to modify male reproductive function by altering sex hormone levels. This study aimed to evaluate the semen and testicular characteristics and hormonal profile of aged Mrakhoz bucks (Capra hircus) treated with letrozole. Methods: Twelve Markhoz male goats, aged between 4.5 to 5.5 years with an average body weight (BW) of 61.05±4.97 kg were used for the study. Animals were randomly divided into two equal groups and subcutaneously received either 0.25 mg/kg BW of letrozole or a control every week for 2 months. The semen collections were performed every 10 days, and blood samples and testicular biometric records were collected at 20 days intervals. Results: Letrozole causes increased testosterone and follicle-stimulating hormone levels, testosterone to estradiol ratio, semen index and reaction time during the period from 20th to 60th days (p<0.05). Furthermore, letrozole-treated bucks had higher semen volume, sperm concentration, and total sperm per ejaculate from 30th to 60th days (p<0.05). However, no differences occurred between the groups in scrotal circumference, relative testicular volume, semen pH, abnormality, acrosome integrity, and membrane integrity of sperm during the study (p>0.05). The serum luteinizing hormone levels, sperm viability, motility, and progressive motility increased, and estradiol levels decreased after 40th to 60th days of letrozole treatment (p<0.05). Conclusion: Letrozole application to aged Markhoz bucks provokes reproductive hormonal axis which, in turn, induces enhancement of semen production and quality.

Comparison of the outcomes of phacoemulsification versus topical medication alone in canine diabetic cataracts: a retrospective study

  • Eunji Lee;Seonmi Kang;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.6
    • /
    • pp.86.1-86.14
    • /
    • 2023
  • Background: Long-term comparisons of phacoemulsification with topical medication are limited in canine diabetic cataracts. Objectives: To compare outcomes of eyes submitted to phacoemulsification with those of topical medication for canine diabetic cataracts and identify risk factors for complications. Methods: Through medical records review, 150 eyes (76 dogs) with diabetic cataracts were included; 58 eyes (31 dogs) underwent phacoemulsification (phaco-group) and 92 eyes (48 dogs) received ophthalmic solution alone (medication-group). The medication-group was divided into owner-led and vet-led groups depending on who elected not to perform surgery. Comparisons involved time-to-complications, vision, and the number and type of ophthalmic solutions administered. The association between complications and pretreatment clinical findings was investigated. Results: No difference was found in complication risk between the phaco and owner-led medication groups. Conversely, the vet-led medication-group had a higher complication risk than the other groups. At the last follow-up, 94.8% of the phaco-group had vision, whereas 7.6% of the medication-group restored some visual axis. Poor glycemic control in the medication-group and younger age in the phaco-group increased complication risk. At 1-year post-treatment, the average number of ophthalmic solutions administered was 1.7 and 2.6 in the phaco and medication groups, respectively. The medication-group used anti-inflammatories the most throughout the follow-up, whereas the phaco-group used anti-inflammatories the most until 1-year post-treatment and lacrimostimulants at 1.5-year post-treatment. Conclusions: For canine diabetic cataracts, phacoemulsification is recommended because it is superior to topical management alone in terms of maintaining vision and reducing the number of ophthalmic solutions required in the long term.

A study on the change of head posture and hyoid bone position before and after rapid maxillary expansions (상악골 급속확장술식 전후 두경부 자세와 설골위치의 변화에 관한 연구)

  • Bae, Hyeon-Cheol;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.569-584
    • /
    • 1997
  • The present study assessed the effects of Rapid Maxillary Expansion on head posture and hyoid bone position. For this study, 32 Angle's class III patients - hellman 3c $\~$ adult stage, mean age 12y9m - were selected and divided into two groups, A,B according to craniocervical angulation. Craniocervical angulation Increased in Group A and decreased in Group B after the therapy. And 23 Angle's class I persons $\~$ same hellman stage, mean age 12y7m $\~$ were selected (or the control group. Cephalometric analysis of skeletal pattern, pharyngeal space, head posture, hyoid bone position was performed. The results were as follows, 1. Comparison of skeletal pattern and pharyngeal space 1) All two groups(A,B) had Mandibular plane inclined inferiorly and no pharyngeal space change was obseved after RME therapy 2) Skeletal pattern and pharyngeal space of Group A, B were normal before and after treatment. 2. Comparison of head posture 1) Craniocervical angulation of Group A was increased after treatment. That of Group B was decreased and mandibular plane was inclined inferiorly after treatment. 2) Before treatment, craniocervical inclination was normal in Group A but larger than normal in Group B. After treatment, all two groups(A, B) had normal craniocervical angulation. 3. Comparison of hyoid bone position 1) After treatment, long axis of hyoid in Group A, B was not changed. Antero- posteriorly, hyoid position was changed posteriorly in Group A but no change was founded in Group B after treatment. Vertically, hyoid bone position were not changed in two groups except increase in APHFH in Group A after treatment 2) Long axis of hyoid bone was normal in Group A, B before and after treatment. Anteroposteriorly, hyoid bone position was more anterior than Group B, C before treatment but all the position of two groups had normal position after treatment. Vertical position of hyoid bone was normal in all two groups before and after treatment.

  • PDF

Benthic Macroinvertebrate Community Changes after Impoundment of Yeongju dam in Korea (영주댐 담수 이후 저서성 대형무척추동물 군집변화)

  • An, Chae-Hui;Han, Jung-Soo;Choi, Jun-Kil;Lee, Hwang-Goo
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.5
    • /
    • pp.515-524
    • /
    • 2019
  • The purpose of this study is to investigate the effects of artificial disturbance by analyzing and comparing the survey data of the Yeongju dam located in Yeongju-si, Gyeongbuk before and after impoundment. We surveyed four sites between the downstream of sediment control to the downstream of Yeongju Dam four times between April and October 2018. The macroinvertebrate data before the survey were gathered from the literature. The total number of benthic macroinvertebrates we observed was $35,037ind./m^2$, including 77 species, 48 families, 14 orders, 7 classes, and 3 phyla. The result of the community analysis showed that the dominant index increased from 0.44(${\pm}0.11$) before impoundment to 0.62(${\pm}0.16$) after impoundment. The diversity index increased from 2.26(${\pm}0.30$) to 1.75(${\pm}0.45$), the evenness index from 0.75(${\pm}0.10$) to 0.66(${\pm}0.14$), and the richness index from 3.11(${\pm}0.98$) to 2.25(${\pm}0.81$). The most dominant species changed from Hydropsychidae spp. to Chironomidae sp. The result of the Principal Components Analysis (PCA) based on Axis 1 showed that the sites of 2014 and Hydropsychidae spp. had a negative value, while the sites of 2018 and Chironomidae sp. had a positive value. In all study sites, the dominance increased while the diversity decreased. The community change was the largest in St. 2. The results of the functional group analysis showed that the scrapers increased while gathering-collectors increased among the functional feeding group and that the clingers decreased while borrows increased among the habitat oriented group. The Benthic Macroinvertebrate Streambed Index (BMSI) decreased from an average of 57.1(${\pm}8.0$, C class) to an average of 30.0(${\pm}12.1$, C class). St. 3 and St. 4, in particular, showed a high reduction rate.

Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading (새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력)

  • Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate screw removal torque of the two-piece zirconia abutment with the novel titanium component compared to the conventional one-piece titanium abutment in the internal connection implant before and after dynamic cyclic loading. Materials and methods: Two types of the abutment assemblies with internal connection were prepared and divided into the groups; titanium abutment-titanium abutment screw assemblies as control, and zirconia abutment-titanium socket-titanium abutment screw assemblies as experimental group. A total of 12 abutments and implants were used of six assemblies each group. Each assembly was tightened to 30 Ncm. A cyclic load of 300 N at an angle of 30 degrees in reference to the loading axis was applied until one million cycles or failure. The removal torque values (RTVs) of the abutment screws were measured with a digital torque gauge before and after cyclic loading. The RTVs of the pre load and post load were analyzed with t-test, and P-values < .05 were considered statistically significant. Results: The assemblies of both groups survived all after the dynamic cyclic loading test without screw loosening. The statistically significant differences were found between the mean RTVs before and after the cyclic loading in both groups (P < .05). The RTV differences for the control and the experimental group were $-7.25{\pm}1.50Ncm$ and $-7.33{\pm}0.93Ncm$, respectively. Statistical analysis revealed that the RTV differences in both groups were not significantly different from each other (P > .05). Conclusion: Within the limitation of this study, the two-piece zirconia abutment with the titanium component did not show a significant RTV difference of the abutment screw compared to the titanium abutment after dynamic cyclic loading.

TENSILE STRENGTH OF LASER WELDED-TITANIUM AND GOLD ALLOYS (티타늄과 금합금의 레이저 용접부의 인장강도)

  • Song, Yun-Gwan;Ha, Il-Soo;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.200-213
    • /
    • 2000
  • Lasers have given dentistry a new rapid, economic, and accurate technique for metal joining. Although laser welding has been recommended as an accurate technique, there are some limitations with this technique. For example, the two joining surfaces must have a tight-fitting contact, which may be difficult to achieve in some situations. The tensile samples used for this study were made from a custom-made pure titanium and type III gold alloy plates. 27 of 33 specimens were sectioned perpendicular to their long axis with a carborundum disk and water coolant. Six specimens remained and served as the control group. A group of 6 specimens was posed as butt joints in custom parallel positioning device with a feeler gauge at each of three gaps : 0.00, 0.25. and 0.50mm. All specimens were then machined to produce a uniform cross-sectional dimension, none of the specimens was subjected to any subsequent form of heat treatment. Scanning electron microscopy was performed on representative tested specimens at fractured surfaces in both the parent metal and the weld. Vickers hardness was measured at the center of the welds with a micropenetrometer using a force of 300gm for 15 seconds. Measurement was made at approximately $200{\mu}m\;and\;500{\mu}m$ deep from each surface. One-way analysis of variance (ANOVA) and Scheffe's test was calculated to detect differences between groups. The purpose of this study is to compare the strength and properties of the joint achieved at various butt Joint gaps by the laser welding of type III gold alloy and pure titanium tensile specimens in an argon atmosphere. The results of this study were as follows : 1. When indexing and welding pure titanium, there was no decrease in ultimate tensile strength as compared with the unsectioned alloys for indexing gaps of 0.00 to 0.50mm, although with increasing gap size may come increased distortion (p>0.05). 2. When indexing and welding type III gold alloy, there were significant differences in ultimate tensile strength among groups with weld gaps of 0.00mm, 0.25 and 0.50mm, and the control group. Group with butt contact without weld gap demonstrated a significant higher ultimate tensile strength than groups with weld gaps of 0.25 and 0.50mm (p<0.05). 3. When indexing and welding the different metal combination of type III gold alloy and pure titanium, there were significant differences in ultimate tensile strength between groups with weld gaps of 0.00, 0.25, and 0.50mm. However, the mechanical properties of the welded joint would become too brittle to be acceptable clinically (p<0.05). 4. The presence of large pores in the laser welded joint appears to be the most important factor in controlling the tensile strength of the weld in both pure titanium and type III gold alloy.

  • PDF

EFFECT OF DECALCIFIED FREEZE-DRIED BONE ALLOGRAFTS AND ROOT PLANING PROCEDURE ON THE HEALING OF TRANSPLANTED ROOTS INTO THE PERIODONTALLY DISEASED EXTRACTION SOCKETS OF DOGS (성견의 치주질환 이환 발치와에 이식된 활택치근과 탈회냉동건조골이 치조골재생에 미치는 영향)

  • Kim, Chong-Kwan;Chai, Jung-Kiu;Cho, Kyoo-Seong;Moon, Ik-Sang;Kim, Jin;Choi, Sang-Mook;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.557-567
    • /
    • 1995
  • The purpose of this study was to investigated the effect of root planing and decalcified freeze dried allografts on the resorption of transplanted roots and the healing of preveously diseased recipient extraction sockets. The experimental chronic periodontitis was induced by elastic ligatures on the 2nd and 3rd mandibular premolars of 4 adult dogs, and after 8 weeks, crowns were removed and the teeth extracted. The extracted roots were split in half along the long-axis, and the extednt of plaque exposure was morked on the root surfaces with burs. The roots were either root-planed(Test group), or left uninstrumented(Control group), and transplanted in the extraction sockets with decalcified freeze-dried allografts filling the void. The flaps were sutured to cover the sockets completely. The animals were sacrificed after 12 weeks of healing, and the specimens were examined histologically. The results were as follows : 1. No signs of inflammation or disease activity were observed in either groups. 2. Replacement root resorption was observed in both groups. 3. More connective tissue attachments and less ankylosis were observed in the test groups compared to the control. 4. The unresorbed remains of DFDB particles were observed in both groups. 5. DFDB particles in the apical portion of the alveolar sockets were encased in newly-formed bone, while those in the coronal areas were seen encapsulated with connective tissue. 6. No significant difference was found between root-planed and uninstrumented roots relative to the healing and the bone fromation in the recipient extraction sockdets. From the present study, there seemed to be no significant benefits in root planing the transplanted roots or grafting the sockets with DFDB in order to curve the replacement resorption, although the root-planed roots showed more connective tissue attachments. There was also no significant benefits in root transplantation and DFDB for and enhanced healing and bone formation in alveolar extraction sockets.

  • PDF

Runner Training Angle Affects Growth of Runners in 'Seolhyang' and 'Maehyang' Strawberries ('설향'과 '매향' 딸기에서 런너 유인 각도가 런너의 생장에 미치는 영향)

  • Zhao, Jin;Li, Yali;Park, Yoo Gyeong;Hu, Jiangtao;Jeong, Byoung Ryong
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.231-238
    • /
    • 2020
  • Strawberry (Fragaria × ananassa Duch.), a herbaceous perennial crop, is a popular fruit crop with high economical and nutritive values. This study was conducted to investigate the effect of the runner training angle (RTA) on the length of internodes and number of runners produced in strawberry 'Seolhyang' and 'Maehyang' in an attempt to achieve a higher production rate of runner plants and increase the propagation efficiency. Runners were trained for 30 days to grow at an angle of 0° (vertically upward), 45°, 90° (horizontal), 135°, or 180° (hanging down) from the upward vertical axis. The experiment was carried out in a glasshouse with 29/20℃ day/night temperatures, an average light intensity of 450 μmol·m-2·s-1 PPFD coming from the sun, and a natural photoperiod of 12 hours. For both 'Seolhyang' and 'Maehyang', the RTA affected number and length of runners, and number and fresh and dry weights of runner plants. Training at an angle of 135° or 180° shortened length of runners and internodes in 'Seolhyang'. These RTAs also produced runner plants with the lowest fresh and dry weights in both cultivars. The RTA did not affect the runner diameter, but affected the runner morphology in both cultivars. As compared to a RTA of 135°, a 180° RTA increased number of runner plants produced, making it the most proliferative RTA.

The Predictable Factors of the Postoperative Kyphotic Change of Sagittal Alignment of the Cervical Spine after the Laminoplasty

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Kim, Dong Ha;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.577-583
    • /
    • 2017
  • Objective : Laminoplasty is an effective surgical method for treating cervical degenerative disease. However, postoperative complications such as kyphosis, restriction of neck motion, and instability are often reported. Despite sufficient preoperative lordosis, this procedure often aggravates the lordotic curve of the cervical spine and straightens cervical alignment. Hence, it is important to examine preoperative risk factors associated with postoperative kyphotic alignment changes. Our study aimed to investigate preoperative radiologic parameters associated with kyphotic deformity post laminoplasty. Methods : We retrospectively reviewed the medical records of 49 patients who underwent open door laminoplasty for cervical spondylotic myelopathy (CSM) or ossification of the posterior longitudinal ligament (OPLL) at Pusan National University Yangsan Hospital between January 2011 and December 2015. Inclusion criteria were as follows : 1) preoperative diagnosis of OPLL or CSM, 2) no previous history of cervical spinal surgery, cervical trauma, tumor, or infection, 3) minimum of one-year follow-up post laminoplasty with proper radiologic examinations performed in outpatient clinics, and 4) cases showing C7 and T1 vertebral body in the preoperative cervical sagittal plane. The radiologic parameters examined included C2-C7 Cobb angles, T1 slope, C2-C7 sagittal vertical axis (SVA), range of motion (ROM) from C2-C7, segmental instability, and T2 signal change observed on magnetic resonance imaging (MRI). Clinical factors examined included preoperative modified Japanese Orthopedic Association scores, disease classification, duration of symptoms, and the range of operation levels. Results : Mean preoperative sagittal alignment was $13.01^{\circ}$ lordotic; $6.94^{\circ}$ lordotic postoperatively. Percentage of postoperative kyphosis was 80%. Patients were subdivided into two groups according to postoperative Cobb angle change; a control group (n=22) and kyphotic group (n=27). The kyphotic group consisted of patients with more than $5^{\circ}$ kyphotic angle change postoperatively. There were no differences in age, sex, C2-C7 Cobb angle, T1 slope, C2-C7 SVA, ROM from C2-C7, segmental instability, or T2 signal change. Multiple regression analysis revealed T1 slope had a strong relationship with postoperative cervical kyphosis. Likewise, correlation analysis revealed there was a statistical significance between T1 slope and postoperative Cobb angle change (p=0.035), and that there was a statistically significant relationship between T1 slope and C2-C7 SVA (p=0.001). Patients with higher preoperative T1 slope demonstrated loss of lordotic curvature postoperatively. Conclusion : Laminoplasty has a high probability of aggravating sagittal balance of the cervical spine. T1 slope is a good predictor of postoperative kyphotic changes of the cervical spine. Similarly, T1 slope is strongly correlated with C2-C7 SVA.

Development of Fiber-end-cap Fabrication Equipment (대구경 광섬유 엔드캡 제작장비 개발)

  • Lee, Sung Hun;Hwang, Soon Hwi;Kim, Tae Kyun;Yang, Whan Seok;Yoon, Yeong Gap;Kim, Seon Ju
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.2
    • /
    • pp.49-54
    • /
    • 2021
  • In this paper, we design and construct the equipment to manufacture large-diameter optical fiber end caps, which are the core parts of high-power fiber lasers, and we fabricate large-diameter optical fiber end caps using the home-made equipment. This equipment consists of a CO2 laser as a fusion-splice heat source, a precision stage assembly for transferring the position of a large-diameter optical fiber and an end cap, and a vision system used for alignment when the fusion splice is interlocked with the stage assembly. The output of the laser source is interlocked with the stage assembly to control the output, and the equipment is manufactured to align the polarization axis of the large-diameter polarization-maintaining optical fiber with the vision system. Optical fiber end caps were manufactured by laser fusion splicing of a large-diameter polarization-maintaining optical fiber with a clad diameter of 400 ㎛ and an end cap of 10×5×2 ㎣ (W×D×H) using home-made equipment. Signal-light insertion loss, polarization extinction ratio, and beam quality M2 of the fabricated large-diameter optical fiber end caps were measured to be 0.6%, 16.7 dB, and 1.21, respectively.