• 제목/요약/키워드: 2-Stroke

검색결과 2,860건 처리시간 0.036초

Associations between Morphological Characteristics of Intracranial Arteries and Atherosclerosis Risk Factors in Subjects with Less Than 50% Intracranial Arterial Stenosis

  • Byun, Hokyun;Jang, Jinhee;Choi, Hyun Seok;Jung, So-Lyung;Ahn, Kook-Jin;Kim, Bum-soo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권3호
    • /
    • pp.150-157
    • /
    • 2018
  • Purpose: To assess associations between morphological characteristics of intracranial arteries in time-of-flight MR angiography (TOF-MRA) and atherosclerotic risk factors. Materials and Methods: From January 2014 to October 2015, a total of 129 patients (65 men and 64 women) without intracranial arterial stenosis > 50% were included in this study. All MRIs were performed using a 3T machine with 3D TOF-MRA sequences. We evaluated irregularity, tortuosity, and dilatation of intracranial arteries in maximal intensity projection (MIP) of TOF-MRA. Subjects' risk factors for atherosclerosis including history of hypertension and diabetes were collected by reviewing their medical records. Associations between morphological characteristics and each known atherosclerosis risk factor were examined using univariate regression analysis. Multivariate regression models were built to determine combined association between those risk factors and morphologic changes of intracranial arteries. Results: In multivariate analysis, hypertension (coefficient [95% CI]: 0.162 [0.036, 0.289], P = 0.012) and absence of diabetes (coefficient [95% CI]: -0.159 [-0.296, -0.023], P = 0.022) were associated with large diameter of intracranial arteries. Males (coefficient [95% CI]: 0.11 [-0.006, 0.23], P = 0.062) and higher age (coefficient [95% CI]: 0.003 [-0.001, 0.008], P = 0.138) had marginal association with increased diameter. Tortuosity was associated with old age (OR: 1.04 [1.02, 1.07], P < 0.001). Irregular contour of intracranial arteries was significantly associated with old age (OR: 1.05 [1.02, 1.09], P = 0.004), presence of diabetes (OR: 2.88 [1.36, 6.15], P = 0.0058), and previous ischemic stroke (OR: 3.91 [1.41, 11.16], P = 0.0092). Conclusion: Morphological characteristics (irregularity, tortuosity, dilatation) of intracranial arteries seen in TOF-MRA might be associated with atherosclerotic risk factors in subjects with no or mild stenosis.

beta-Galaetosidase의 고정화 및 응용에 관한 연구 제2보: Aspergillus niger CAD 1의 효소 교정화 조건 및 고정화 효소의 성질 (Studies on immobilization and application of beta-galactosidase II. Preparation and properties of the immobilized enzyme from Aspergillus niger CAD 1)

  • 이용규;전순배;최원기;정기철;배석;김관천
    • 한국식품영양과학회지
    • /
    • 제15권4호
    • /
    • pp.40-46
    • /
    • 1986
  • 제1보에서 보고한 Aspergillus niger CAD 1의 beta-galactosidase를 cellulose triacetate를 담체로 하여 고정화조건을 검토하였던바, 13%(v/v)의 정제된 효소와 10%(w/v)의 cellulose triacetate를 30분간, 150stroke/min으로 진탕하면서 포괄시킨 고정화 효소의 활성이 가장 좋았다. 고정화 효소의 최적온도는 $45^{\circ}C$, 최적 pH는 4.5로서수용성 효소의 것과 같았다. 기질로서 ONPG와 유당에 대한 Km값은 각각 $8.3{\timess}10^{-3}$$117.0{\times}10^3M$, Vmax값은 각각 $30.3{\times}10^3M$$5.0{\times}10^3M$이였다. 본 고정화 효소는 $4^{\circ}C$에서 90일간 저장시에 90%, $45^{\circ}C$에서 5회 사용후에 70%의 잔존활성을 나타냈으며 유당분해율도 좋았다.

  • PDF

A Study of Electromagnetic Actuator for Electro-pneumatic Driven Ventricular Assist Device

  • Jung Min Woo;Hwang Chang Mo;Jeong Gi Seok;Kang Jung Soo;Ahn Chi Bum;Kim Kyung Hyun;Lee Jung Joo;Park Yong Doo;Sun Kyung
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권6호
    • /
    • pp.393-398
    • /
    • 2005
  • An electromechanical type is the most useful mechanism in the various pumping mechanisms. It, however, requires a movement converting system including a ball screw, a helical cam, or a solenoid-beam spring, which makes the device complex and may lessen reliability. Thus, the authors have hypothesized that an electromagnetic actuator mechanism can eliminate the movement converting system and that thereby enhance the mechanical reliability and operative simplicity of an electro­pneumatic pump. The purpose of this study was to show a novel application of electromagnetic actuator mechanism in pulsatile pump and to provide preliminary data for further evaluations. The electromagnetic actuator consists of stators with a single winding excitation coil and movers with a high energy density neodymium-iron-boron permanent magnet. A 0.5mm diameter wire was used for the excitation coil, and 1000 turns were wound onto the stators core with parallel. A prototype of extracorporeal electro-pneumatic pump was constructed, and the pump performance tests were performed using a mock system to evaluate the efficiency of the electromagnetic actuator mechanism. When forward and backward electric currents were supplied to the excitation coil, the mover effectively moved back and forth. The nominal stroke length of the actuator was 10mm. The actuator dimension was 120mm in diameter and 65mm in height with a mass of 1.4kg. The prototype pump unit was 150mm in diameter, 150mm in thickness and 4.5kg in weight. The maximum force output was 70N at input current of 4.5A and the maximum pump rate was 150 beats per minute. The maximum output was 2.0 L/minute at a rate of 80bpm when the afterload was 100mmHg. The electromagnetic actuator mechanism was successfully applied to construct the prototype of extracorporeal electro­pneumatic pump. The authors provide the above results as a preliminary data for further studies.

퍼팅 스트로크에서 퍼터의 선 운동량 크기에 따른 볼의 이동 속도 변화에 관한 연구 (Ball Velocity Changes Depending on the Different Linear Momentum of Putter Head during the Putting Strokes)

  • 박진
    • 한국운동역학회지
    • /
    • 제17권4호
    • /
    • pp.83-88
    • /
    • 2007
  • The purpose of this study was to investigate the ball velocity changes depending on the different linear momentum of putter head. For this study, two different moving conditions(25cm free fall and 35cm free fall) of putter head were set. And two different types of ground conditions were used which are artificial grass green($180cm{\times}600cm{\times}1cm$) and glass green($40cm{\times}130cm{\times}1cm$). Movements of putter head and ball were recorded with 2 HD video cameras(60 Hz, 1/500s shutter speed). Small size control object($18.5cm{\times}18.5cm{\times}78.5cm$) was used in this study. Ball and putter head velocities were calculated by the First Central Difference Method(Hamill & Knutzen, 1995). Linear momentum of ball and putter head were calculated with mass and its velocities. Before impact, the velocity of the putter head of 35cm free fall was about 30% greater than that of the putter head of 25cm free fall. Linear momentum of putter head of 35cm free fall was about 0.355-0.364kg m/s and 25cm free fall was 0.251 kg m/s. After impact, putter head lost its linear momentum about 14-19% and adjusting time of putter head after impact would be 0.1 second. After 0.1 second, putter moved the route same as before impact. Maximum ball velocities were appeared 0.08s-0.10s after impact no matter what the ground conditions are. Ball velocities struck by 35cm free fall were 30 % faster than 25cm free fall. Linear momentum of ball struck by putter head was greater than that of expected amount because the moving ball has translational energy and rotational energy. Future study must treat three things. One is ball must struck by the different putters with different materials. Another is two-piece ball and three-piece ball should be used for the same condition studies. The other is height of center of rotation of club should be changed. In this study, the height of center of rotation of club head is 71cm from the ground. But recently many golfers used the long putter. Therefore next study should apply the different height of center of rotation of club head.

상호억제 기법에 의한 경직성 편마비 환자 보행의 공간적, 시간적 특성 변화 (Characteristics Change of Spatial and Temporal Parameters of Gait in Spastic Hemiplegic Patients by Reciprocal Inhibition)

  • 김종순;이현옥;안소윤;구봉오;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제16권4호
    • /
    • pp.59-79
    • /
    • 2004
  • The purpose of this study was to determined the effects of reciprocal inhibition on spatial-temporal gait parameters in spastic hemiplegic patients through GaitRite system. The subjects were consisted 45 patients who had spastic hemiplegia due to stroke. All subjects randomly assigned to 3 group : manual reciprocal inhibition program group(manual group), neuromuscular electrical stimulation group(NMES group) and control group. The manual group received voluntary isometric contraction of pre-tibia muscle. The NMES group received neuromuscular electrical stimulation on tibialis anterior. The control group was not recieved any therapeutic intervention. Before and after experiments, spatial-temporal gait parameters and functional ambulatory profile was measure in all patients. The data of 30 patients who complete experimental course were statistically analysed. The results of this study were as following : 1. The percentage of change of functional ambulatory profile were markedly increased in manual group but statistically non significant(p>.01). 2. The percentage of change of gait velocity and cadence were markedly increased in manual group but statistically non significant(p>.01). 3. Asymmetry ratio of gait elements were more improved in manual group but statistically non significant(p>.01). 4. There were no statistical difference between pre-test and post-test with functional ambulatory profile, gait velocity, cadence and asymmetry ratios in NMES group(p>.01). 5. There were no statistical difference between pre-test and post-test with unctional ambulatory profile, gait velocity, cadence and asymmetry ratios in control group(p>.01). In conclusion, the present results revealed that reciprocal inhibition which produced by voluntary isometric contraction of pre-tibia muscle can be improved spatial-temporal gait parameters including functional ambulatory profile in hemiplegic patients. Therefore, reciprocal inhibition is useful to improve functional activities in hemiplegic patient. Further study should be done to analyze the effects of intervention duration of reciprocal inhibition, appropriate muscle contraction, optimal time to apply the reciprocal inhibition in more long period.

  • PDF

심장 판막 수술 후 미세색전의 변화 (Changes of Microembolic Signals after Heart Valve Surgery)

  • 조수진;이은일;백만종;오삼세;나찬영
    • Journal of Chest Surgery
    • /
    • 제36권5호
    • /
    • pp.316-320
    • /
    • 2003
  • 배경: 경두개 초음파 검사에 의한 미세색전의 진단은 향후 뇌색전증의 위험이 높은 환자의 선별에 큰 도움이 되리라 기대된다. 우리는 전향적으로 심장 판막 수술 전과 후의 미세색전의 양성률과 빈도를 검사하였다. 대상 및 방법: 심장 판막 질환이 있는 50명의 환자를 대상으로 본 연구는 진행되었다. 뇌경색의 병력이 있거나, 과거에 인공 기계 심장 판막 수술을 받은 환자는 본 연구에서 제외하였다. 경두개 초음파 검사는 중대뇌동맥에서 1시간 동안 미세색전을 감시하였고, 수술 전과 수술 후 2차례 검사하였다. 결과: 기계 심장 판막 수술은 28명, 조직 판막 수술은 10명, 승모판막 성형술은 12명에서 시행되었다. 미세색전의 양성률은 수술 전(8%)에 비하여 수술 후(50%)에 의미 있게 증가하였으며 (p=0.00), 미세색전은 항응고제 강도, 심장 부정맥, 환자의 연령, 고혈압의 병력과 관련성이 없었다. 기계 심장 판막 이식수술 후 미세색전의 양성률(71.4%)은 조직 판막 이식수술(10%)이나 승모판막 성형술(33.3%)에 비하여 의미 있게 높았다(p=0.002). 결론: 미세색전은 심장 판막 수술 후 의미 있게 증가하며 이러한 변화는 인공 기계 심장 판막 수술 후 색전증의 위험과 관련되어 있다고 추정된다.

상지장애인의 컴퓨터 사용을 위한 무선 자이로마우스의 개발 및 임상평가 (Development and Clinical Evaluation of Wireless Gyro-mouse for the Upper Extremity Disabled to Use Computer)

  • 한하나;송은범;김철승;허지운;엄광문
    • 감성과학
    • /
    • 제9권2호
    • /
    • pp.93-100
    • /
    • 2006
  • 본 연구에서는 교통사고나 뇌졸중 등에 의해 상지의 장애를 가지는 장애인을 대상으로 하여, 인터넷의 브라우저와 같은 소프트웨어를 사용 할 수 있는 컴퓨터 인터페이스로서 자이로센서를 이용한 무선 자이로 마우스시스템를 개발하고, 임상평가를 통해 그 유용성을 확인하고자 한다. 시스템 개발에 있어서 주안점은, 첫째, 장애인의 경우 휠체어나 침대에 누워서 마우스 조작을 할 수 있도록 시스템의 무선화하는 것, 둘째, 착탈의 용이성과 미관을 위하여 센서를 헤드 밴드에 삽입하는 것, 셋째, 컴퓨터 운영체제에게 클릭신호를 전달하기 위하여, $C5{\sim}C6$ 환자들의 경우에는 클릭 스위치를 사용하고, C4환자의 경우에는 고개의 끄덕임을 검출하도록 하는 것이다. 개발된 시스템을 척수손상으로 인한 상지 장애인을 대상으로 평가실험을 실시하였다. 그 결과 시행횟수가 증가할수록 상하/좌우 이동시의 목표위치에 대한 실제위치의 오차가 감소하고, 1분당 클릭률이 증가하는 경향을 확인하였다. 이로부터, 개발된 무선 자이로마우스 시스템은 환자의 반복사용을 통해 그 유용성이 증가할 것을 알 수 있다.

  • PDF

하악 정중선의 편위와 하악골의 높이차가 저작근 활성에 미치는 영향 (Effects of Mandibular Midline Shift and Difference of Mandibular Height on the Masticatory Muscle Activity)

  • 정대연;한경수;현태연;곽동곤
    • Journal of Oral Medicine and Pain
    • /
    • 제26권1호
    • /
    • pp.75-85
    • /
    • 2001
  • This study was performed to investigate the effect of mandibular midline shift and difference of mandibular height between both sides on the electromyo- graphic(EMG) activity of the masticatory muscles on clenching or gum chewing movement. For this study, 105 patients with temporomandibular disorders(TMD) were selected and panoramic radiograph were taken. Amount and side of the midline shift and height of the mandible from antegonial notch to the top of the condylar head were measured on panoramic view. $BioEMG^{(R)}$ (Bioresearch Inc., Milwaukee, USA) was used for recording of EMG activity(${\mu}V$) of the anterior temporalis and the superficial masseter on clenching or gum chewing movement. EMG activity on clenching during 533msec period were measured for activity of the starting point and the one second-after activity as the early EMG and the maximum EMG, respectively. EMG activity on gum chewing movement were measured for activity of the first and the second chewing stroke. The data collected were analysed by SPSS windows program, and the results of this study were as follows : 1. Height of the mandible was 8.06cm on right side and 8.03cm on left side, and showed no difference by age, but significantly differed by sex with higher in male subjects. 2. Mean value of the midline shift was 0.1mm with range of 0~5mm on both sides. The amount and side of the midline shift did not related with height difference of the mandible and/or the EMG activity of the masticatory muscles on clenching. 3. Prevalence of higher right side and higher left side of the mandible were almost same, and the EMG activity of higher side was not higher than that of the other side. 4. In the subjects with height difference of more than 5mm between both sides of the mandible, the early EMG activity on clenching were differed for the anterior temporalis, but the maximum activity were differed for the superficial masseter. 5. In the subjects with height difference of more than 5mm between both sides of the mandible, EMG activity of the anterior temporalis of the gum chewing side was not higher than that of the other side when chewing on the side of lower height, but in the subjects with height difference of less than 5mm, the EMG activity was higher than that of the other side.

  • PDF

Effect of Ultra-Soft and Soft Toothbrushes on the Removal of Plaque and Tooth Abrasion

  • Jeong, Moon-Jin;Cho, Han-A;Kim, Su-Yeon;Kang, Ka-Rim;Lee, Eun-Bin;Lee, Ye-Ji;Choi, Jung-Hyeon;Kil, Ki-Sung;Lee, Myoung-Hwa;Jeong, Soon-Jeong;Lim, Do-Seon
    • 치위생과학회지
    • /
    • 제18권3호
    • /
    • pp.164-171
    • /
    • 2018
  • To improve the oral health status of Korean people, it is necessary to encourage proper oral hygiene management habits, such as toothbrushing, through appropriate health promotion techniques. Therefore, the purpose of this study was to evaluate the removal of plaque and tooth abrasion using ultra-soft (filament 0.11~0.12 mm) and soft toothbrushes for toothbrushing. The plaque removal was performed using a dentiform and Arti-spray, and the Patient Hygiene Performance (PHP) index was calculated as the sum total score divided by the total number of surfaces. In the abrasivity experiment, according to the number of brushings, a micro Vickers hardness tester was used, and a sample in the range of 280~380 Vickers hardness number was selected. The number of toothbrushing stroke were 1,800 (2 months), 5,400 (6 months), 10,800 (12 months), and 21,600 (24 months). The tooth abrasion was measured using a scanning electron microscope. Statistical analysis was performed using IBM SPSS Statistics 22.0 and a p-value <0.05 was considered significant. According to the results, there was no statistically significant difference in the degree of plaque removal between ultra-soft and soft toothbrushes. The difference in tooth abrasion between before and after toothbrushing was found to be greater with the soft toothbrushes than with the ultra-soft toothbrushes. Therefore, the ultra-soft toothbrush not only lowers tooth damage by reducing tooth abrasion, but also shows a similar ability to remove plaque as soft toothbrushes.

중풍임상자료(中風臨床資料)에 대한 통계적(統計的) 분석방법연구(分析方法硏究) (A study of statistical techniques for clinical data about cerebrovascular diseases)

  • 강효신;권영규;박창국;신양규;김상철
    • 대한한의학회지
    • /
    • 제17권1호
    • /
    • pp.302-328
    • /
    • 1996
  • I. 연구개발(硏究開發)의 목적(目的) 및 중요성(重要性) 한국(韓國) 임상자료(臨床資料)를 효과적(效果的)으로 모으기 위한 자료수집용(資料收集用) 진료부(診療簿) 형식(形式)을 고안(考案)함으로써 전문가(專門家)의 지식(知識)을 체계적(體系的)으로 수집(收集)하고 통계분석시(統計分析時) 유효(有效)한 결과(結果)를 기대(期待)할 수 있도록 한다. 진료부(診療簿) 형식(形式)은 개인별(個人別) 편차(偏差)가 심(甚)한 한국(韓國) 임상자료(臨床資料)의 문제점(問題點)을 수집단계(收集段階)에서 해결(解決)하는데 매우 중요(重要)하며 또한 수집(收集)된 자료(資料)는 전문가(專門家)시스템의 지식(知識)으로 제공(提供)되므로 핵심적(核心的)인 연구자료(硏究資料)가 된다. II. 연구개발(硏究開發)의 내용(內容) 및 범위(範圍) 임상자료(臨床資料) 수집(收集)을 위한 진료부형식(診療簿形式)의 고안(考案), 임상자료(臨床資料) 분석(分析), ODS의 진단(診斷)과 전문가(專門家) 진단(診斷)의 비교(比較)를 내용(內容)으로 하며, 연구범위(硏究範圍)는 한의(韓醫) 임상자료중(臨床資料中) 많은 환자분포(患者分布)를 보이고 있는 중풍환자(中風患者)를 대상(對象)으로 이와 관련(關聯)된 지식(知識) 및 용어(用語)를 정리(整理)하되 중풍환자(中風患者)는 CT로 뇌혈관질환(腦血管疾患)이 확인(確認)된 환자(患者)로 한정(限定)하였다. III. 연구개발결과(硏究開發結果) 및 활용(活用)에 대한 건의(建議) 자료수집용(資料收集用) 진료부(診療簿)는 임상자료(臨床資料)의 수집(收集), 관련지식(關聯知識) 및 용어정리(用語整理), 그리고 타(他) 진료기관(診療機關)의 임상자료수집(臨床資料收集)에 활용(活用)하며, 임상자료(臨床資料)에 대한 평가분석(評價分析)의 결과(結果)는 차후 타(他) 질환자료(疾患資料) 수집(收集)이나 시스템구축(構築)에 필요(必要)한 임상자료(臨床資料)로 활용(活用)된다. 또한 이 자료(資料)는 임상교육(臨床敎育) 및 임상자료(臨床資料)를 통(通)한 한양방(韓洋方)의 협진자료(協診資料)로 활용(活用)될 수 있을 것으로 기대(期待)된다.

  • PDF