• Title/Summary/Keyword: 2-OLT PON

Search Result 19, Processing Time 0.032 seconds

Design and Performance Evaluation of The ONU and OLT Supporting VPN Function over ATM-PON (ATM-PON에서 VPN 기능 지원을 위한 ONU와 OLT의 설계와 성능분석)

  • 장종욱;박미리;전형구;남재현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.1
    • /
    • pp.57-64
    • /
    • 2004
  • Passive optical network that use passive component is economical network, and can provide service of high speed to subscribers. The function of VPN which is operated like private network is needed to many companies. There are two methods to implement VPN over ATM-PON. One is located at ONU and OLT system and another is located at core network. In this paper, we implemented to SCB and P2P adding VPN function to ONU and OLT of ATM-PON system. We knew that the proposed method has more fast transmission and more small traffic than other method in the field of the performance.

Implementation of FTTH System based on G-PON Technology (G-PON 기술 기반 FTTH 시스템 구현)

  • Park, Chun-Kwan;Song, Han-Young;Jeon, Byung-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.77-88
    • /
    • 2008
  • This paper addresses the implementation of FTTH system based on G-PON technology. This system supports the duplication function that can switchover both TDM and data routes within 10msec. This system consists of OLT and ONU/ONT. G-PON OLT supports the maximum 32 2.5Gbps interfaces, and then has the flexibility and the scalability for supplying digital communication and broadcasting convergence service in the near future. OLT system consists switch module, subscriber module, processor module, and G-PON link module, and has the operating system based on Linux. ONU is installed in customer premise to supply TPS (Triple Play Service). Also ONT has the dedicated interface for IP-TV to improve the transmission characteristics of IP-TV signal.

  • PDF

Protection/Restoration of PON Systems Using WDM based 2-OLT Structure (WDM 기반 2-OLT 구조를 이용한 PON 시스템 보호 및 절체)

  • Rawshan, Fahmida;Park, Youngil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37B no.12
    • /
    • pp.1168-1173
    • /
    • 2012
  • In this paper, we propose a protection architecture of passive optical network (PON) system by using two optical line terminals (OLTs). Using this scheme, the network can sustain services to access area and restores normal operation in faulty conditions. Unlike existing systems, the proposed one increases the efficiency of the system by operating both OLTs using different wavelengths in normal condition. During protection mode, a Shared-bandwidth allocation scheme is employed to maximize the utilization efficiency. Performance analysis shows that the proposed scheme can provide reliability to Ethernet-based PON system very efficiently.

Implementation of FTTH System based on Ethernet PON Technology (이더넷 PON 기술 기반 FTTH 시스템 구현)

  • Park Chun-Kwan;Jeon Byung-Chun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.2 s.344
    • /
    • pp.66-75
    • /
    • 2006
  • This paper addresses the implementation of FTTH system based on Ethernet PON technololy. This system consists of OLT and ONT. OLT supports the maximum 24 Gigabit Ethernet interfaces, and then has the flexibility and the scalability for supplying digital communication and broadcasting convergence service in the near future. OLT system consists of switch module, subscriber module, processor module, and E-PON link module, and has the operating system based on Linux. ONT is installed in customer premise to supply both IP-TV and Internet service. Also ONT has the dedicated interface for IP-TV to improve the transmission characteristics of IP-TV signal. We measure the performance of E-PON MAC through this system and then QoS control characteristics per franc in ONT by separating the virtual link for IP-TV from that for data.

Implementation and performance evaluation of the ONU&OLT supporting VPN in the ATM-PON (ATM-PON 환경에서 VPN지원을 위한 ONU와 OLT 기능 구현 및 성능 분석)

  • 박미리;장성호;이대봉;장종옥
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.306-310
    • /
    • 2002
  • Today, corporations are approach to inside information using public network such as Internet groping economical way to utilize public network to corporation information network without buying equipment. But, special quality of internet, Virtual Private Net (VPN) that it uses net that is observed as technology that can be guaranteed public safety division transmission and data securitybecause of can not secure data transmission. In this paper. add VPN function ONU&OLT of ATM-PON system and propose SCB (Single Copy Broadcasting). When there is VPN function to ATM network, the speed can be fast, and reduce rain track pick quantity during time more. Performance analysis network simulation that use NS-2.

  • PDF

Implementation of a Predictor for Cell Phase Monitoring at the OLT in the ATM-PON (ATM-PON의 OLT에서 상향 셀 위상감시를 위한 예측기의 구현)

  • Mun, Sang-Cheol;Chung, Hae;Kim, Woon-Ha
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.2C
    • /
    • pp.160-169
    • /
    • 2002
  • An ATM-PON (Passive Optical Network) system consists of an OLT (Optical Line Termination), multiple ONUs (Optical Network Units) and the optical fiber which has a PON (Passive Optical Network)configuration with a passive optical splitter. To avoid cell collisions on the upstream transmission, an elaborate procedure called as ranging is needed when a new ONU is installed. The ONU can send upstream cells according to the grant provided by the OLT after the procedure. To prevent collisions being generated by the variation of several factors, OLT must performs continuously the cell phase monitoring. It means that the OLT predicts the expected arrival time, monitors the actual arrival time for all upstream cells and calculates the error between the times. Accordingly, TC (Transmission Convergence) chip in the OLT needs a predictor which predicts the time that the cell will arrive for the current grant. In this paper, we implement the predictor by using shift registers of which the length is equivalent to the equalized round trip delay. As each register consists of 8 bit, OLT can identify which ONU sends what type of cell (ranging cell, user cell, idle cell, and mini-slot). Also, TC chip is designed to calculate the effective bandwidth for all ONUs by using the function of predictor. With the time simulation and the measurement of an implemented optical board, we verify the operation of the predictor.

Design and Verification of LAN Emulation Function for Hybrid Two-Stage AWG based WDM-PON (혼합형 2단 AWG 기반의 WDM-PON을 위한 LAN 에뮬레이션 기능 설계 및 검증)

  • Han, Kyeong-Eun;Yang, Won-Hyuk;Kim, Young-Chon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.3B
    • /
    • pp.91-99
    • /
    • 2008
  • In this paper, we design the function of ULSLE(Upper Layer Shared LAN Emulation) to provide both the efficient LAN service and compatibility with 802.1D bridge in Hybrid two-stage AWG based WDM-PON. The ULSLE layer lies above MAC control layer in order to provide a mean to interface WDM-PON and 802.1D bridge. It also performs LAN emulation based on PON-Tag which is only used to decide both the transmission mode and the destination of frames transmitted from ONUs. That is, the PON-Tag is not used for downstream frames but destination address field in original frame instead. This decreases the processing overhead and complexity caused by PON-Tag at OLT and ONU. The verification of designed ULSLE is performed according to the specific scenarios based on transmission mode and destination using OPNET.

Physical Media Dependent Prototype for 10-Gigabit-Capable PON OLT

  • Kim, Jongdeog;Lee, Jong Jin;Lee, Seihyoung;Kim, Young-Sun
    • ETRI Journal
    • /
    • v.35 no.2
    • /
    • pp.245-252
    • /
    • 2013
  • In this work, we study the physical layer solutions for 10-gigabit-capable passive optical networks (PONs), particularly for an optical link terminal (OLT) including a 10-Gbit/s electroabsorption modulated laser (EML) and a 2.5-Gbit/s burst mode receiver (BM-Rx) in a novel bidirectional optical subassembly (BOSA). As unique features, a bidirectional mini-flat package and a 9-pin TO package are developed for a 10-gigabit-capable PON OLT BOSA composed of a 1,577-nm EML and a 1,270-nm avalanche photodiode BM-Rx, including a single-chip burst mode integrated circuit that is integrated with a transimpedance and limiting amplifier. In the developed prototype, the 10-Gbit/s transmitter and 2.5-Gbit/s receiver characteristics are evaluated and compared with the physical media dependent (PMD) specifications in ITU-T G.987.2 for XG-PON1. By conducting the 10-Gbit/s downstream and 2.5-Gbit/s upstream transmission experiments, we verify that the developed 10-gigabitcapable PON PMD prototype can operate for extended network coverage of up to a 40-km fiber reach.

Decentralized TDM-PON MAC Protocol Based on Power Detection (파워검출 기반의 분산형 TDM-PON MAC 프로토콜)

  • Lee, Sung-Kuen;Kim, Eal-Lae;Lee, Yong-Won;Lee, Sang-Rok;Jung, Dae-Kwang;Hwang, Seong-Taek;Oh, Yun-Je;Park, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2B
    • /
    • pp.83-89
    • /
    • 2007
  • In this paper, we have proposed the power detection (PD)-based TDM-PON architecture, which is implemented with a hardware-based decentralized DBA (Dynamic Bandwidth Allocation) algorithm among ONUs, without OLT's intervention. Of particular importance in the proposed approach is that the hardware-based power detection scheme is used to manage the distributed MAC algorithm without any complex, time-consuming and costly software-processing elements for DBA in ONUs and OLT. We evaluate the performance of average packet end-to-end delay in a statistical analysis and numerical analysis. In addition, through simulations with various traffic models, we verified the superior performance of the proposed approach by comparing with the results of other E-PONs.

Implementation of a DBA Algorithm with the Maximum Link Bandwidth Allocation in the G-PON (G-PON에서 최대 링크 대역폭까지 할당이 가능한 DBA 알고리즘의 구현)

  • Chung, Hae;Hong, Jung-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1549-1560
    • /
    • 2009
  • In the TDMA PON system, the DBA is essential for ONUs to send data efficiently to the upstream. In this paper, we implement a DBA processor for the G-PON OLT with downstream and upstream rate, 2.5 and 1.25 Gbps, respectively, The processor collects bandwidth request messages from ONUs at every cycle time and allocates properly bandwidth to each Alloc-ID with considering priority and fairness for traffics. In the proposed DBA algorithm, one cycle time consists of multiple G-PON frames ($m{\times}125{\mu}s$) for high link efficiency. In particular, the link efficiency is higher because the algorithm adopts a method that an additional overhead is eliminated when an allocated bandwidth is laid between two G-PON frames for an ONU. This enables that the processor flexibly allocates the bandwidth from zero to the maximum link capacity for an ONU. The proposed DBA processor is implemented with the FPGA and shows bandwidth allocating processes for ONUs with logic analyzer.