• 제목/요약/키워드: 2-Methylisoborneol

검색결과 27건 처리시간 0.024초

강변여과에 의한 이.취미 물질 제어 특성에 관한 타당성 연구 (A Feasibility study on Removal Characteristics of Taste and Odor using Bank Filtration Treatment)

  • 맹승규;박노석;임재림;김성수;정우창
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.307-317
    • /
    • 2010
  • This study was conducted in order to investigate bulk organic matter characteristics and behavior of geosmin and 2-methylisoborneol (2-MIB) during riverbank filtration, which are general surrogates of taste and odor in drinking water. Column studies were used to simulate bank filtration systems. Most of the aliphatic organic matter was removed effectively after soil passage, and it is believed to be polysaccharides according to LC-OCD and F-EEM analysises. Removal efficiencies of geosmin and 2-MIB within the filtration column reached above 95%. It was found that the removal of total dissolved organic matter has a correlation with that of geosmin and 2-MIB in the near of filtration surface (about 50cm).

Characteristics of deodorization for malodorants in aqueous solution by sonication

  • Yoo, Young-Eok;Maeda, Yasuaki
    • 한국환경과학회지
    • /
    • 제13권2호
    • /
    • pp.167-173
    • /
    • 2004
  • A aqueous solution of malodorants (i.e., n-valeraldehyde, n-valeric- acid, 2-methylisoborneol, and trimethylamine) was exposed to 200KHz ultrasound with a power of 6.0W/$\textrm{cm}^2$ per unit volume in a sonochemical reactor under room temperature and atmospheric pressure condition. The concentration of malodorants decreased with irradiation time, indicating pseudo-first-order kinetics. The removal efficiency of malodorants was about from 50% to 96% decomposed after 90 minutes sonication. At the deodorization, it was determined by triangle odor bag(TOB) method for odor sensory measurement, and it indicated that over 60% of relative odors were deodorized with degradation by the sonication.

다단 나노여과 공정에서 고농도 geosmin 및 2-Methylisoborneol (MIB)의 제거특성 (Rejection property of geosmin and 2-Methylisoborneol (MIB) with high concentration level at multi stage nanofiltration (NF) membrane system)

  • 유영범;최양훈;김동진;권순범;김충환
    • 상하수도학회지
    • /
    • 제28권4호
    • /
    • pp.397-409
    • /
    • 2014
  • Algal problem in drinking water treatment is being gradually increased by causing deterioration of water supplies therefore, especially taste and odor compounds such as geosmin and 2-MIB occur mainly aesthetic problem by its unpleasant effects resulting in the subsequent onset of complaints from drinking water consumer. Recently, geosmin and 2-MIB are detected frequently at abnormally high concentration level. However, conventional water treatment without advanced water treatment processes such as adsorption and oxidation process, cannot remove these two compounds efficiently. Moreover, it is known that the advanced treatment processes i.e. adsorption and oxidation have also several limits to the removal of geosmin and 2-MIB. Therefore, the purpose of this study was not only to evaluate full scale nanofiltration membrane system with $300m^3/day$ of permeate capacity and 90% of recovery on the removal of geosmin and 2-MIB in spiked natural raw water sources at high feed concentration with a range of approximately 500 to 2,500 ng/L, but also to observe rejection property of the compounds within multi stage NF membrane system. Rejection rate of geosmin and 2-MIB by NF membrane process was 96% that is 4% of passage regardless of the feed water concentration which indicates NF membrane system with an operational values suggested in this research can be employed in drinking water treatment plant to control geosmin and 2-MIB of high concentration. But, according to results of regression analysis in this study it is recommended that feed water concentration of geosmin and 2-MIB would not exceed 220 and 300 ng/L respectively which is not to be perceived in drinking tap water. Also it suggests that the removal rate might be depended on an operating conditions such as feed water characteristics and membrane flux. When each stage of NF membrane system was evaluated relatively higher removal rate was observed at the conditions that is lower flux, higher DOC and TDS, i.e., $2^{nd}$ stage NF membrane systems, possibly due to an interaction mechanisms between compounds and cake layer on the membrane surfaces.

한강을 원수로 하는 오존/과산화수소 고도정수처리공정에서의 MIB제거 및 잔류오존 농도에 관한 연구 (Use of Hydrogen Peroxide with Ozone to Simultaneously Reduce MIB and Quench Ozone Residual in Existing Water Treatment Plants Sourcing Water from the Han River)

  • ;구본진;장명훈;이성규
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.704-716
    • /
    • 2012
  • 본 논문은 California의 South Lake Tahoe, 서울 뚝섬정수장 그리고 성남 복정정수장에서 2010년 2월에서 2012년 2월까지 수행된 파일럿 실험에 대한 분석결과를 기초로 작성되었다. 본 실험의 목적은 첫째, 한강을 원수로 하는 모래여과 처리수에 대한 오존 및 과산화수소(Peroxone)의 반응특성을 파악하고, 둘째는 AOP(고도산화공정)을 통해 맛 냄새 유발물질인 2-methylisoborneol(MIB)를 제거하기위한 경험적인 오존 및 과산화수소의 투입량을 결정하고자 하였다. 또한 셋째로, 처리공정이후 인체에 안전한 잔류오존농도로 감소시키기 위한 최적 투입량을 결정하고자 하였다. 본 실험은 계절의 기온변화에 따라 저수온 및 고수온의 조건하에서 실시간으로 수행되었다. 본 실험을 통해 오존의 분해속도는 온도와 pH에 영향을 받는 것으로 나타났으며, 이는 다른 연구결과와 일치한다. 원수로 모래여과수에 MIB를 40~50ng/L의 농도로 투입하였으며, 모든 경우에서 7ng/L 이하로 처리되었으며 대부분의 경우에서 검출(ND)되지 않았다. Peroxone은 MIB을 제거할 뿐아니라 오존을 단독으로 사용한 경우보다 오존+과산화수소 동시에 투입한 경우에 잔류오존농도가 더 낮았다. 저수온에서 상당량의 오존이 반응 및 분해를 통해 감소된다. 본 실험을 통해 "Pre-Conditioned" 과산화수소를 적용함으로써 초기 반응율을 향상시키고 잔류오존농도를 낮출 수 있었으며, 약품의 과투입 및 효율저하를 방지하는 과산화수소의 투입 위치 및 구성 그리고 투입방법을 제시하였다.

Pulse UV 장치를 이용한 먹는 물의 이취미 유발물질 제거효과에 관한 연구 (Removal of taste and odor causing compounds in drinking water using Pulse UV System)

  • 손진식;박순호;정의택
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.219-228
    • /
    • 2012
  • Problems due to the taste and odor in drinking water are common in treatment facilities around the world. Taste and odor are perceived by the public as the primary indicators of the safely and acceptability of drinking water, and are mainly caused by the presence of two semi-volatile compounds-2-methylisoborneol(2-MIB) and geosmin. Conventional treatment processes in water treatment plants, such as coagulation, sedimentation and chlorination have been found to be ineffective for the removal of 2-MIB and geosmin. Pulse UV system is a new UV irradiation system that is a non-mercury lamp-based alternative to currently used continuous wave systems for water disinfection. This study shows pulse UV system to be effective in treatment of these two compounds. Geosmin removal efficiency of UV process alone achieved approximately 70% at 10sec contact time. 2-MIB removal efficiency of UV only process achieved approximately 60% at 10sec contact time. The addition of $H_{2}O_{2}$ 7mg/L increased geosmin and 2-MIB removal efficiency upto approximately 94% and 91%, respectively.

SPME를 이용한 Geosmin과 2-MIB분석 시 잔류염소의 영향에 관한 연구 (Effect of Residual Chlorine on the Analysis of Geosmin and 2-MIB Using SPME (Solid Phase Microextraction))

  • 김성진;홍성호;민달기
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.713-719
    • /
    • 2005
  • SPME (Soild phase microextraction) has been used in the analysis of many volatile organic compounds, such as geosmin and 2-methylisoborneol (2-MIB), trihalomethanes (THMs) in drinking water. SPME fiber is characterized by high adsorption capacity (DVB/CAR/PDMS, DVB/PDMS etc.). Although the highly active adsorption capacities of the SPME fiber are often to the chemical functional group, surface properties play a significant role in determining the surface adsorption capacities. The objectives of this study were to evaluate effect of residual chlorine on analysis of geosmin and 2-MIB. Image taken by SEM before preloaded with chlorine, the surface and porous media was almost perfect spherical shape and no clogging of pores. However, after preloaded with chlorine the surface was aggregated and pore was blocked. The recovery rate of geosmin and 2-MIB coexisting with chlorine was reduced by 35 to 62%. The recovery rate with preloaded with chlorine was reduced by 25 to 43%. The lower concentration of geosmin and 2-MIB and the higher concentration of chlorine existed in water, the lower the recovery rate was.

신탄과 재생탄에서 자연유기물질의 분자량이 이·취미(2-MIB) 흡착능에 미치는 영향 (Effect of Molecular Weight of NOM for Adsorption of 2-MIB on Virgin and Reactivated GAC)

  • 김성진;홍성호;최주솔
    • 상하수도학회지
    • /
    • 제21권6호
    • /
    • pp.671-678
    • /
    • 2007
  • 2-methylisoborneol (MIB) is a musty odor compound produced as a secondary metabolite by some cyanobacteria and actinomycetes. It is lead to distrust in tap water due to taste and odor. It is well known that activated carbon (AC) adsorption is the best available technology to remove 2-MIB and geosmin. In this study, physical characteristics of virgin AC and reactivated AC was compared. The effect of variation of NOM molecular weight on adsorption of 2-MIB in virgin AC and reactivated AC were also evaluated. BET surface area was decreased by 13 to 23% and total pore volume was decreased by 18 to 21% due to first and second reactivation compare to the virgin carbon. However, mesopore volume ($V_{meso}$) was increased about 14% after reactivation. It showed that micropore volume was decreased and move to mesopore or macropore after reactivation. Decreased adsorption capacity of 2-MIB was greatly related to below 3000Da. Adsorption capacity of 2-MIB was rather greater in virgin AC than in reactivated, which is strongly related to micropore volume.

정수처리에서 서로 다른 공정의 처리효율에 대한 비교분석연구 (Efficiency Evaluation of Different Processes in Drinking Water Treatment)

  • 김형석;이병호
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.597-604
    • /
    • 2011
  • This study was performed to compare finished water quality among three different processes. A detailed assessment of performance was carried out during the five months of operation. Finished water quality was evaluated on the basis of parameters such as Dissolved organic carbon (DOC), $UV_{254}$ absorbance, haloacetic acid formation potential (HAAFP), geosmin, 2-methylisoborneol (2-MIB), heterotrophic bacteria and total coliform bacteria. The treatment processes were Process 1 (coagulation-flocculation-sedimentation-sand filtration-ozone-GAC), Process 2 (coagulation-flocculation-sedimentation -microfiltration-ozone-GAC), and Process 3 (coagulation-flocculation-sedimentation- sand filtration-GAC), compared side by side in the pilot testing. Process 2 was found to have better removal efficiency of DOC, $UV_{254}$ absorbance, HAAFP and heterotrophic bacteria in comparison with process 1 and process 3 under identical conditions. Geosmin, 2-MIB and total coliform bacteria were not detected in finished water from each process.

미량오염물질 및 맛 냄새유발물질의 제거를 위한 오존/AOP 및 활성탄 공정의 적용성에 관한 연구 (Study on the applicability of the ozone / AOP and activated carbon process for the removal of trace organic contaminants and taste odor causing substances)

  • 하정태;임지열;길경익
    • 한국습지학회지
    • /
    • 제17권2호
    • /
    • pp.155-162
    • /
    • 2015
  • 정수처리공정에서 미량유기물질과 맛 냄새물질인 2-methylisoborneol (2-MIB)와 geosmin의 제거특성을 파악하기 위하여 오존 및 advanced oxidation process (AOP)와 입상활성탄으로 구성된 biological activated carbon (BAC)공정과 활성탄 단독공정인 granular activated carbon (GAC)공정에 대한 pilot plant를 수행하였다. 운전 결과, 2-MIB 159 ng/L, geosmin 371 ng/L의 고농도에서 오존 1.0 mg/L 주입시 42%, 86%의 제거율을 나타냈으며 $H_2O_2$ 0.5 mg/L를 추가주입한 AOP 공정에서 각각 58%, 90%의 제거율 상승을 나타냈다. 또한 BAC공정에서 99.8%의 제거율을 나타냈으며 GAC 공정에서 2 ng/L이하의 처리성능을 보였다. 따라서 미량유기물질 및 맛 냄새 물질의 지속적인 제거를 위해서는 오존/AOP와 활성탄의 처리효과를 조합한 BAC 공정이 효과적으로 나타났으며, 활성탄지의 흡착능을 지속적으로 유지하기 위해서 유입농도에 따른 오존/AOP 공정의 최적화가 필요한 것으로 판단된다.

의암호와 공지천 하류에서 남조류와 냄새물질의 발생 특징 (Characteristics of Cyanobacteria and Odorous Compounds Production in Lake Uiam and Lower Gonji Stream)

  • 윤석제;임종권;변명섭;유순주
    • 한국물환경학회지
    • /
    • 제35권2호
    • /
    • pp.99-104
    • /
    • 2019
  • The objective of this study was to investigate the relationship between the biomass of cyanobacteria and the concentration of 2-methylisoborneol (2-MIB) in the lower Gongji stream. The investigation was done using a field study that was conducted from 2015 to 2017. The 2-MIB concentration in the lower Gongji stream ranged from 0 to 153 ng/L, while the upper stream had 0 2-MIB concentration. 3 genera (Oscillatoria, Phormidium, Pseudanabaena) of cyanobacteria were detected in the lower Gongji stream with 2-MIB concentration. Among these 3 genera, an increase in Phormidium, Pseudanabaena biomass was associated with an increase in 2-MIB concentration. Accordingly, Phormidium, Pseudanabaena were regarded as the biological source of 2-MIB in that area. In October 2017, although planktonic cyanobacteria occurred less frequently, many benthic cyanobacteria mats were observed on the surface of the water body. Therefore, the high 2-MIB concentration, which exceeded 110 ng/L, can likely be attributed to the benthic cyanobacteria. In a laboratory experiment, individual Oscillatoria filaments were aggregated to form a colony with a higher density. This colony tended to float on the water surface. Cyanobacteria mats after floating aggregated mats were distributed in a net shape on the bottom.