• Title/Summary/Keyword: 2-Dimensional Drainage

Search Result 59, Processing Time 0.021 seconds

Development of Distributed Rainfall -Runoff Model by Using GIS and Uncertainty Analysis (II) - Application and Analysis - (GIS와 불확실도 해석기법을 이용한 분포형 강우 -유출 모형의 개발 (II) - 적용 및 분석 -)

  • Choi, Hyun-Sang;Han, Kun-Yeun
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.4
    • /
    • pp.341-352
    • /
    • 2004
  • In this study(II), the model developed in the previous study(I) has been tested on two cases of constant-slope areas to verify the model applicability. Firstly, an impervious one-dimensional runoff problem has been simulated. Secondly, an impervious two-dimensional runoff problem at a converging plain which consists of a V-shaped section plus a portion of the surface of a cone has been simulated. For each case, the simulation results have good agreements with the observed data. And the model has been applied to actual watersheds, which were the Sulma watershed with 8$\textrm{km}^2$ and the Donggok watershed with 33.2$\textrm{km}^2$, drainage area, respectively. The simulated results agree with observed in terms of discharges at several stations. Monte Carlo simulation was also performed on the same watersheds and the modeling results have been evaluated. The suggested model can be used for real-time forecasting of rainfall-runoff analysis, and will contribute for basinwide flood control in the future.

Flood Inundation Analysis in Urban Area Using XP-SWMM (XP-SWMM 모형을 이용한 도심지역 침수해석)

  • Kim, Jinsu;Lee, Wonho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Current domestic research is to demonstrate the effectiveness and efficiencies of flood prevention measures through one-dimensional numerical analysis and this study's object is to help water managers to make the efficient decisions by applying the two-dimensional urban run off model XP-SWMM model in the flooded area and comparing with the flood prevention measures. Statistics were analyzed, based on the data collected from Cheongju Weather Service from 1967 to 2011 for 45 years. 50 years Flood frequency simulations of water flow capacity analysis of the target area for flooded areas $539,548m^2$, inundation depth 1.0 m, was analyzed by inundation time of 48 minutes. When comparing with the constructions of bypass road and underground storage facilities to increase the water flow capacity of A1 small drainage areas as flood protection, if you install a batching target underground detention basin with a capacity of $13,500m^3$, it is expected that the flood by rainfall with frequency of 50 years will be resolved completely. In preparation for extreme weather in the future flood mitigation measures, underground storage tank installation is considered a better efficient way.

Behavior of Geotextile Tube Composite Structure by 2-D Limit Equilibrium and Plane Strain Analysis (2차원 한계평형 및 평면변형해석을 통한 지오텍스타일 튜브 복합구조물의 거동분석)

  • Shin, Eunchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.6
    • /
    • pp.13-22
    • /
    • 2006
  • The geotextile have been used in filtration and drainage for over 30 years in many applications of civil and environmental projects. Geotextile tube is compound technology of filtration and drainage property of geotextile. Geotextile have been used for various types of containers, such as small hand-filled sandbags, 3-dimensional fabric forms for concrete paste, large soil and aggregate filled geotextile gabion, prefabricated hydraulically filled containers, and other innovative systems involving containment of soils using geotextile. They are hydraulically filled with dredged materials. It have been applied in coastal protection and scour protection, dewatering method of slurry, and isolation of contaminated material. Recently, geotextile tube technology is no longer alternative construction technique but suitable desired solution. This paper presents the behavior of geotextile tube composite structure by 2-D limit equilibrium and plane strain analysis. 2-D limit equilibrium analysis was performed to evaluate the stability of geotextile tube composite structure for the lateral load and also the plane strain analysis was conducted to determine the design and construction factors. Based on the results of this paper, the three types of geotextile tube composite structure is stable. And the optimum tensile strength of geotextile is 151kN/m and maximum pumping pressure is 22.7kN/m.

  • PDF

Hydraulic Performance Analysis of Tangential Vortex Intakes with Compound Section by Three-Dimensional Numerical Simulation (3차원 수치모의에 의한 복단면 형상의 접선식 와류 유입구 수리 특성 분석)

  • Lee, Du Han;Rhee, Dong Sop;Kim, Myounghwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.506-514
    • /
    • 2014
  • Recently the interest about the vortex intakes are rapidly increased because of its performance to drain a plenty of collected storm water at a time. The tangential intake a kind of vortex intakes is very applicable because this type is very simple and little against other types, but it has a big weakness that the vortex flow is not been rarely created below the design discharge. In this study, the characteristics of a tangential intake and two kinds of a newly suggested compound section type intake are analyzed by the 3D numerical modeling based on theories about the control shift and free drainage condition. The analysis focused on the flow condition, flow surface formation, depth-discharge relation, area ratio of air core. Based on this study, the mild-sloped compound section type intake is the optimal, but steep-sloped compound section type is also the optional for the small design discharge.

Three Dimensional Strength Characterisics of Compressible Sand (압축성 모래의 3차원 전단강도 특성)

  • Park, Byeong-Gi;Jeong, Jin-Seop;Im, Seong-Cheol
    • Geotechnical Engineering
    • /
    • v.6 no.3
    • /
    • pp.65-76
    • /
    • 1990
  • A series of consolidated drained and untrained cubical triaxial tests were performed to investigate three dimensional strength characteristics of compressible sand. All specimens, which are formed by deposisting a fine sand loosely, were used. Failure strength in terms of effective stress analysis was greatly influenced by the variation of intermediate principal stress and so was failure criterion The adjusted effective frictional angles obtained by the stress state projected on the same octahedral plane showed almost same value, while the measured effective frictional angles showed considerable difference depending on the drainage conditions. Results of total stress analysis in undrained test turned out to fit Tresca's failure criterion well, but results of effective stress analysis turned out to fit Lade's failure criterion well.

  • PDF

Urban Flood Simulation Considering Building and Sewer Lines (건물 및 우수 배제를 고려한 시가지 범람해석)

  • Kang, Sang-Hyeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3B
    • /
    • pp.213-219
    • /
    • 2009
  • In densely urban areas, features such as the sewer system, buildings and river banks have an effect on flow dynamics and flood propagation, and will therefore be accounted for in the model set-up. While two-dimensional (2D) flood models of urban areas are at the forefront of current research into flood inundation mechanisms, they are however constrained by inadequate parameters of topography, and insufficient and inaccurate data. In this study, an urban flood model (overland flow, 2D urban flood flow and sewer flow) was combined and applied at Samcheok city which was damaged by inundation in 2002, in order to simulate inundation depth. The influence of buildings and pumping capacity was also analyzed to estimate the inundated depth in the study area. As a result, it was found that urban inundated depth are affected by pumping capacity directly and it increased about 20-30 cm on most of the modeled area with a building share rate of 0.2-0.6 per unit grid.

Study of flood prevention alternative priorities using MCDM (Multi-Criteria Decision Making) (MCDM을 이용한 홍수방어대안 우선순위 정립에 관한 연구)

  • Lim, Donghwa;Jeong, Soonchan;Lee, Eunkyung;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.3
    • /
    • pp.169-179
    • /
    • 2017
  • Recently, due to global warming and climate change in Korea, local heavy storm occurs frequently. In this study, the risky areas for flooding in urban areas are analyzed for flood inundation based on two-dimensional urban flood runoff model (XP-SWMM) focusing on coastal high flood-risk urban areas. In addition, the MCDM (Multi-Criteria Decision Making) technique is utilized in order to establish the flood defense structural measures. The alternative flood reduction method are compared and the optimum flood defense measures are selected. A simulation model was used with three structural flood prevention measures (drainage pipe construction, water detention, flood pumping station). In order to decrease the flooding area, flood assessment criteria are suggested (flooded area, maximum inundation depth, damaged residential area, construction cost). Priorities of alternatives are determined by using compromise programming. As a result, the optimal flood defence alternative suggested for Janghang Zone 1 is flood pumping station and for Janghang Zone 2, 3 are drainage pipe construction.

Flood Simulation for Basin-Shaped Urban Watershed Considering Surface Flow (분지형 도시유역에서의 노면류를 고려한 침수모의)

  • Ahn, Jeonghwan;Cho, Woncheol;Jung, Jaehee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.841-847
    • /
    • 2014
  • Urban runoff models have been continuously developing with concerns for urban flood. Recently, models that be able to quantitatively analyze surface inundation caused by overflowed water from storm sewer were also developed by coupling 1-dimensional sewer model and 2-dimensional surface flow model. However, only overflowed water from storm sewer can be analyzed by the models have been developed until now. They are limited to be not able to analyze surface inundation caused by surface runoff that could not flow into the storm sewer. In order to overcome the limitation, basin-overlap method was devised adding a dummy 1-dimensional sewer layer to the model, so it can consider the efficiency of inflow to the storm sewer system. XP-SWMM 2011 is applied for urban runoff model and the flood event occurred on July 27, 2011 in basin-shaped Sadangcheon watershed is chosen for study inundation event. According to simulation results basin-overlap method reappear the observed inundation event more precisely than traditional method. This results suggest that drainage system has to be improved for reducing inundation caused by surface runoff and would be used as considerations for planning an urban basin design magnitude.

A Comparative Study on the Measures Determining Optimal SAGD Locations Based on Geostatistical and Multiphysics Simulations (지구통계 및 다중 유체 거동 모사에 근거한 스팀주입중력법 적용 최적지 결정 척도 개발 연구)

  • Kwon, Mijin;Jeong, Jina;Lee, Hyunsuk;Park, Jin Beak;Park, Eungyu
    • Economic and Environmental Geology
    • /
    • v.50 no.3
    • /
    • pp.225-238
    • /
    • 2017
  • In this study, two viable measures of mean length and cumulative thickness of sand layers as important spatial statistics responsible for optimal SAGD (Steam Assisted Gravity Drainage) location for oil sand development were compared. For the comparisons, various deposits composed of sand and clay media were realized using a geostatistical simulator and the extent of steam chamber is simulated using multiphysics numerical simulator (dualphase flow and heat transfer). Based on the spatial statistics of each realization and the corresponding size of simulated steam chamber, the representativeness of two candidate measures (cumulative thickness and mean length of permeable media) were compared. The results of the geostatistical and SAGD simulations suggest that the mean length of permeable media is better correlated to the size of steam chamber than the cumulative thickness. Given those two-dimensional results, it is concluded that the cumulative thickness of the permeable media alone may not be a sufficient criterion for determining an optimal SAGD location and the mean length needs to be complementarily considered for the sound selections.

Mixing Characteristics of Nonconservative Pollutants in Paldang Lake (팔당호에 유입된 비보존성 오염물질의 혼합거동)

  • Seo, Il Won;Choi, Nam Jeong;Jun, In Ok;Song, Chang Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3B
    • /
    • pp.221-230
    • /
    • 2009
  • In Korea, many water intake plants are easily affected by effluents of sewage treatment plants because sewage treatment plants are usually located upstream or nearby the plants of the same riverine area. Furthermore, the inflow of harmful contaminants owing to pollutant spills or transportation accidents of vehicles using the roads and bridges intersecting the river causes significant impact on the management of water intake plants. Paldang lake, the main water intake plants in Korea, is especially exposed to various water pollution accidents, because the drainage basin area is significantly large compared to the water surface area of the lake. Therefore it is necessary to predict the possible pollutant spill in advance and consider measurements in case of water pollution. In this study, water quality prediction was performed in Paldang Lake in Korea durig the dry season using two-dimensional numerical models. In order to represent the cases of pollutant accidents, the difference of pollutant transport patterns with varying injection points was analyzed. Numerical simulations for hydrodynamics of water flow and water quality predictions were performed using RMA-2 and RAM4 respectively. As a result of simulation, the difference of pollutant transport with the injection points was analyzed. As a countermeasure against the pollutant accident, the augmentation of the flow rate is proposed. In comparison with the present state, the rapid dilution and flushing effects on the pollutant cloud could be expected with increase of flow rate. Thus, increase of flow rate can be used for operation of water intake plants in case of pollutant spill accidents.