• Title/Summary/Keyword: 2-Dimensional

Search Result 15,170, Processing Time 0.048 seconds

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee, Suk;Lee, Sang-Hoon;Shin, Dong-Ho;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.122-125
    • /
    • 2004
  • In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration gating techniques that can adjust patients' beds by using reversed values of the data obtained. The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range 3 cm ${\sim}$3 m), host computer (RS232C) and stepping motor (torque 2.3Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place in order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data(three dimensional data form with distance of 2cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. The result of analyzing the acquisition-correction delay time for the three types of data values and about each value separately shows that the data values coincided with one another within 1% and that the acquisition-correction delay time was obtained real-time (2.34 ${\times}$ 10$^{-4}$sec). This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultra sonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

  • PDF

Development and Feasibility Study for Phase Contrast MR Angiography at Low Tesla Open-MRI System (저자장 자기공명영상 시스템에서의 위상대조도 혈관조영기법의 개발과 그 유용성에 대한 연구)

  • Lee, Dong-Hoon;Hong, Cheol-Pyo;Lee, Man-Woo;Han, Bong-Soo
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.177-187
    • /
    • 2012
  • Magnetic resonance angiography (MRA) techniques are widely used in diagnosis of vascular disorders such as hemadostenosis and aneurism. Especially, phase contrast (PC) MRA technique, which is a typical non contrast-enhanced MRA technique, provides not only the anatomy of blood vessels but also flow velocity. In this study, we developed the 2- and 3-dimensional PC MRA pulse sequences for a low magnetic field MRI system. Vessel images were acquired using 2D and 3D PC MRA and the velocities of the blood flow were measured in the superior sagittal sinus, straight sinus and the confluence of the two. The 2D PC MRA provided the good quality of vascular images for large vessels but the poor quality for small ones. Although 3D PC MRA gave more improved visualization of small vessels than 2D PC MRA, the image quality was not enough to be used for diagnosis of the small vessels due to the low SNR and field homogeneity of the low field MRI system. The measured blood velocities were $25.46{\pm}0.73cm/sec$, $24.02{\pm}0.34cm/sec$ and $26.15{\pm}1.50cm/sec$ in the superior sagittal sinus, straight sinus and the confluence of the two, respectively, which showed good agreement with the previous experimental values. Thus, the developed PC MRA technique for low field MRI system is expected to provide the useful velocity information to diagnose the large brain vessels.

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

Influence of the angles and number of scans on the accuracy of 3D laser scanning (3 차원 레이저 스캔영상 채득 시 스캔각도와 횟수에 따른 정확도)

  • Lee, Kyung-Min;Song, Hyo-Young;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.76-86
    • /
    • 2011
  • Objective: To investigate whether the accuracy of 3D laser scanning is influenced by the angles and number of scans. Methods: Using a 3D laser scanner, 10 manikins with facial markers were scanned at 7 horizontal angles (front view and at $20^{\circ}$, $45^{\circ}$, and $60^{\circ}$ angles on the right and left sides). Three-dimensional facial images were reconstructed by 6 methods differing in the number and angles of scans, and measurements of these images were compared to the physical measurements from the manikins. Results: The laser scan images were magnified by 0.14 - 0.26%. For images reconstructed by merging 2 scans, excluding the front view; and by merging 3 scans, including the front view and scans obtained at $20^{\circ}$ on both sides; several measurements were significantly different than the physical measurements. However, for images reconstructed by merging 3 scans, including the front view; and 5 scans, including the front view and scans obtained at $20^{\circ}$ and $60^{\circ}$ on both sides; only 1 measurement was significantly different. Conclusions: These results suggest that the number and angle of scans influence the accuracy of 3D laser scanning. A minimum of 3 scans, including the front view and scans obtained at more than $45^{\circ}$ on both sides, should be integrated to obtain accurate 3D facial images.

Quantitative Micro-CT Evaluation of Microleakage in Composite Resin Restorations (Micro-CT를 이용한 복합 레진 수복물 미세 누출도의 정량 분석)

  • Lee, Sang-Ik;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.222-233
    • /
    • 2007
  • One of the most important and basic test of dental restorative materials is the evaluation of microleakage into the tooth-restorative interface. There are many techniques to test microleakage, but most of them have several disadvantages. Recently developed microtomography(micro-CT) can provide the three dimensional image and information about the internal component in non-destructive way, therefore using micro-CT, it is possible to evaluate microleakage exactly in quantitative manner. The purpose of this study is to find a new method for quantitative and non-destructive evaluation of microleakage in composite resin restorations using micro-CT and to compare the new method with conventional dye penetration method. Thus, microleakages of two kinds of dentin bonding systems were evaluated with above two methods. 40 extracted sound human premolars were randomly divided into two groups consisting of 20 samples and restored accordingly. Group 1 : Class V resin restorations with $Adper^{TM}$ Singe Bond Group, 2 : Class V resin restorations with $Adper^{TM}\;Promp^{TM}$ L-pop. The $Filtek^{TM}$ Supreme was applied to the Class V cavities of all teeth. After that, 10 teeth from each group were applied to evaluation of microleakage using micro-CT, and other 10 teeth from each group were using conventional dye penetration method. The conclusions of this study were as follow : 1 Using micro-CT, Group 1 showed significantly less microleakage than Group 2 and there was statistically significant difference(p<0.01) between two groups. 2. Using conventional dye penetration method, Group 1 leaked less than Group 2 and there was statistically significant difference(p<0.01) between two groups 3. The difference between two groups is more evident in the method using micro-CT. 4. In all two methods, microleakage appeared more into the cavities to dentinal margins than enamel margins.

  • PDF

Results of Radiotherapy for the Uterine Cervical Cancer (자궁경부암의 방사선치료성적)

  • Kim, Chul-Yong;Choi, Myung-Sun;Suh, Won-Hyuck
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.63-73
    • /
    • 1988
  • One hundred fifty-four patients with the carcinoma of the uterine cervix were studied retrospectively to assess the result and impact of treatment at Department of Radiation Oncology, Korea University, Hae-Wha Hospital from Feb 1981 through Dec. 1986. Prior to radiotherapy, the patients were evaluated and staged by recommendation of FIGO including physical examination, pelvic examination, cystoscopy, rectosigmoidoscopy, chest X-ray, IVP. Ba enema. Also, an additional pelvic CT scan was obtained for some of the patients. The patients were treated by radiotherapy alone or adjuvant postoperative irradiation; in case of radiation therapy only, whole pelvic irradiation was given with Co-60 teletherapy unit via AP and PA parallel opposing fields or 4-oblique fields, 180 cGy per day, 5 days per week and intracavitary insertion was performed. In satges Ia, Ib, and IIa with small primary lesion, external irradiation was initially given to pelvis up to $2,000\~3,000\;cGy/2frac{1}{2}\;-3frac{1}{2}$ weeks and then intracavitary insertion was performed using Fletcher-Mini-Declos Applicator with cesium-137 cources and followed by external irradiation of $1,000\~2,000\;cGy/1frac{1}{2}\;-2frac{1}{2}$weeks via AP and PA parallel opposing fields with midline shield to spare of bladder and rectum. However, if the primary lesion is large, external irradiation was given without midline shield. More than stages IIb, the patients were treated by external beam irradiation up to 5,400cGy/30f for 6 weeks via 4-oblique portals and at the dose of 5,040cGy/28f the field was cut 5cm from the top margin for spare of small bowel, and followed by intracavitary irradiation, If there was residual tumor an additional dose of $900\~l,200cGy/5\~7f$ was given to parametrium and/or residual tumor area. Total dose of radiation to A and B-point were as follows; A-point; In early stages, Ia, Ib, IIa; $8,000\~9,000$ B-point $5,000\~6,000 cGy$ A-point; In advanced stages IIb, IIIa, IIIb; $9,000\~10,000$ B-point $60,000\~7,000cGy$ The results were obtained and as fellows; 1 The patients distribution according to FIGO staging system were stage Ia 6, Ib 27, IIa 28, IIb 54, IIIa 12, IIIb 18, and stage IVa 9. 2. Value of CT scan were demonstration of cervix tumor mass, parametrial and pelvic side wall tumor spread, pelvic and inguinal lymph nodes metastases, and hydronephrosis. Three dimensional quantitative demonstration of tumor volume is also important in planning radiation therapy. Another advantage of CT scan was detection of recurrent tumor after radiation or surgery. 3. Local control rate of tumor according to the size was $91.3\%$ for less than 5cm in size and $44.6\%$ in tumor over 5cm (p<0.0068). 4. Thirty out of 50 recurrent sites has locoregional failures and 17 cases has distant metastases. And the para-aortic lymph nodes were the most common site for distant metastases. 5. The most common complication was temporal rectal bleeding which was controlled most by conservative management. However, 4 patients required for endoscopic cauterization. 6. The 5-year survival rates showed; stage la and Ib $95\%,\;stage\;IIa\;81\%\;stage\;lIb\;67\%,\;stage\;IIIa\;37.7\%,\;stage\;IIIb\;23\%$ and 3-year survival rate of stage IVa showed $11.6%$, retrospectively.

  • PDF

Radiation Therapy of Nasopharyngeal Carcinoma (비인두강 종양의 방사선치료성적)

  • Nho Young Ju;Cho Jeong Gill;Ahn Seung Do;Choi Eun Kyung;Kim Jong Hoon;Kang One Chul;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.305-313
    • /
    • 1997
  • Purpose : This is a retrospective study to evaluate the results of radiation therapy and prognostic factors influencing the results in nasopharyngeal carcinoma. Materials and Methods: From October 1989 to May 1996. 56 Patients were treated for nasopharyngeal carcinoma at Department of Radiation On-cology. According to stage, patients were distributed as follows : stage I (2), II (13). II (11), IV (30). Twenty-eight patients were treated with radiation therapy only, 7 patients were treated with neoadiuvant chemotherapy followed by radiation therapy. Twenty-one Patients were treated with radiation therapy and weekly CDDP. After external beam radiotherapy of 60Gy, 46Patients received boost dose with intracavitary radiation and 9 Patients with 3D conformal therapy. One patient received boost dose with 2 dimensional Photon beam therapy. The tumor dose ranged from 69.4Gy to 86.2Gy with median dose of 74.4Gy. The follow-up Period ranged from 5 months to 92 months with a median of 34 months. Results : Forty-seven patients achieved complete response and 8 Patients showed partial response. One Patient showed minimal response. Patterns of failure were as follows : locoregional recurrence (8) and distant metastasis (18). Among these patients, 2 patients failed locoregionally and distantly. The sites of distant metastasis were bone (8), lung (8) and liver (4). Five years survival rate was $67.2\%$ and 5 years disease-free survival rate was $53.6\%$. KPS (P=0.005) and response ol radiation therapy (P=0.0001) were significant prognostic factors for overall survival. KPS (P= 0.02) and response of radiation therapy (P=0.005) were significant Prognostic factors for disease-free survival. Conclusion : This retrospective study showed that distant metastasis was the Predominant pattern of relapse in nasopharyngeal cancer Neoadiuvant chemotherapy or weekly CDOP did not influence the distant metastasis-free survival. For advanced T stage, 3D conformal therapy Provided an improved dose coverage compared to ICR But further follow-up was needed in Patients with 3D conformal therapy to assess the efficacy of this therapy. Development of techniques of radiation therapy to improve locoregional control and of more effective systemic chemotherapy regimen are needed.

  • PDF

Stress distribution following face mask application using different finite element models according to Hounsfield unit values in CT images (CT상의 HU 수치에 따른 상악골 전방견인 효과의 유한요소 분석)

  • Chung, Dong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.412-421
    • /
    • 2006
  • Objective: The result of finite element analysis depends on material properties, structural expression, density of element, and boundar or loading conditions. To represent proper elastic behavior, a finite element model was made using Hounsfield unit (HU) values in CT images. Methods: A 13 year 6 month old male was used as the subject. A 3 dimensional visualizing program, Mimics, was used to build a 3D object from the DICOM file which was acquired from the CT images. Model 1 was established by giving 24 material properties according to HU. Model 2 was constructed by the conventional method which provides 2 material properties. Protraction force of 500g was applied at a 45 degree downward angle from Frankfort horizontal (FH) plane. Results: Model 1 showed a more flexible response on the first premolar region which had more forward and downward movement of the maxillary anterior segment. Maxilla was bent on the sagittal plane and frontal plane. Model 2 revealed less movement in all directions. It moved downward on the anterior part and upward on the posterior part, which is clockwise rotation of the maxilla. Conclusion: These results signify that different outcomes of finite element analysis can occur according to the given material properties and it is recommended to use HU values for more accurate results.

Development and Evaluation of Model-based Predictive Control Algorithm for Effluent $NH_4-N$ in $A^2/O$ Process ($A^2/O$ 공정의 유출수 $NH_4-N$에 대한 모델기반 예측 제어 알고리즘 개발 및 평가)

  • Woo, Dae-Joon;Kim, Hyo-Soo;Kim, Ye-Jin;Cha, Jae-Hwan;Choi, Soo-Jung;Kim, Min-Soo;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • In this study, model-based $NH_4-N$ predictive control algorithm by using influent pattern was developed and evaluated for effective control application in $A^2/O$ process. A pilot-scale $A^2/O$process at S wastewater treatment plant in B city was selected. The behaviors of organic, nitrogen and phosphorous in the biological reactors were described by using the modified ASM3+Bio-P model. A one-dimensional double exponential function model was selected for modeling of the secondary settlers. The effluent $NH_4-N$ concentration on the next day was predicted according to model-based simulation by using influent pattern. After the objective effluent quality and simulation result were compared, the optimal operational condition which able to meet the objective effluent quality was deduced through repetitive simulation. Next the effluent $NH_4-N$ control schedule was generated by using the optimal operational condition and this control schedule on the next day was applied in pilot-scale $A^2/O$ process. DO concentration in aerobic reactor in predictive control algorithm was selected as the manipulated variable. Without control case and with control case were compared to confirm the control applicability and the study of the applied $NH_4-N$control schedule in summer and winter was performed to confirm the seasonal effect. In this result, the effluent $NH_4-N$concentration without control case was exceeded the objective effluent quality. However the effluent $NH_4-N$ concentration with control case was not exceeded the objective effluent quality both summer and winter season. As compared in case of without predictive control algorithm, in case of application of predictive control algorithm, the RPM of air blower was increased about 9.1%, however the effluent $NH_4-N$ concentration was decreased about 45.2%. Therefore it was concluded that the developed predictive control algorithm to the effluent $NH_4-N$ in this study was properly applied in a full-scale wastewater treatment process and was more efficient in aspect to stable effluent.

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee Suk;Lee Sang Hoon;Shin Dongho;Yang Dae Sik;Choi Myung Sun;Kim Chul Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.316-324
    • /
    • 2004
  • Purpose : In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration sating techniques that can adjust patients' beds by using reversed values of the data obtained. Materials and Methods : The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range $3\~3$ m), host computer (RS232C) and stepping motor (torque 2.3 Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place In order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data (three dimensional data form with distance of 2 cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. Results : The result of analyzing the acquisition-correction delay time the three types of data values and about each value separately shows that the data values coincided with one another within $1\%$ and that the acquisition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. Conclusion : This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultrasonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.