• Title/Summary/Keyword: 2-D shape

Search Result 2,494, Processing Time 0.033 seconds

Morphological Characteristics, Developmental Period, Seasonal Occurrence, and Sweetpotato Consumption of Aedia leucomelas (L.) (Lepidoptera Noctuidae) (뒷날개흰밤나방(Aedia leucomelas)의 형태적 특징, 온도별 발육기간, 발생소장 및 고구마 섭식량)

  • 이건휘;백채운;김두호;최만영;나승용;김상수
    • Korean journal of applied entomology
    • /
    • v.42 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • Morphological characteristics, developmental period, and seasonal occurrence of Adeia leucomelas (L.) were investigated from 1999 to 2000. In addition, consumption of sweetpotato as food was also examined. Adults of A. leucomelas were dark-brown and body lengths of females and males were 20.2 mm and 18.9 mm, respectively, Wing expanse of female and male was 33.7 mm and 29.4mm, respectively. Egg was flat round-shape. Larva was light yellow-green to dark-brown with 3.3-53.5 mm. Pupa was deep-brown and 15.1 mm in length. Developmental periods of A. leucomelas from egg to adult emergence at different temperatures of 15, 20, 25, and 30$^{\circ}$C were 108.5, 70.7, 40.2, and 29.1 days, respectively, Developmental threshold (DT) and effective accumulative temperatures were estimated as 10.7$^{\circ}$C and 67.5 DD in egg stage, 11.0$^{\circ}$C and 275.1 DD in larval stage and 9.3$^{\circ}$C and 244.6 DD in pupal stage, respectively. The longevity of adult female was shortened with increment of temperature, whereas the total numbers of eggs laid by a female were increased. The larvae of A.leucomelas occurred from mid-June to early October, and population reached its peak during early to mid-September in Jeonbuk province. Food consumption of A. leucomelas was highest at 20-25$^{\circ}$C. Food consumption of 1 st, 2nd, 3rd, 4th, and 5th larvae of A. leucomelas per day at 25$^{\circ}$C was 0.4, 3.6, 19.6, 40.7, and 78.9 $\textrm{cm}^2$, respectively.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

Three Dimensional MRI and Software for Studying Normal Anatomical Structures of an Entire Body (온몸의 정상 해부구조물을 익히기 위한 3차원 자기공명영상 및 소프트웨어)

  • Lee, Yong-Sook;Park, Jin-Seo;Hwang, Sung-Bae;Cho, Jae-Hyun;Chung, Min-Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.117-133
    • /
    • 2005
  • For identifying the pathological findings in magnetic resonance images (MRIs), normal anatomical structures in MRIs should be identified in advance. For studying the anatomical structures in MRIs, a learning tool that includes the followings is necessary. First, MRIs of the entire body; second, horizontal, coronal, and sagittal MRIs; third, segmented images corresponding to the MRIs; fourth, three dimensional (3D) images of the anatomical structures in the MRIs; fifth, software incorporating the MRIs, segmented images, and 3D images. Such a learning tool, however, is hard to obtain. Therefore, in this research, such a learning tool which helps medical students and doctors study the normal anatomical structures in MRIs was made as follows. A healthy young Korean male adult with standard body shape was selected. Six hundred thirteen MRIs of the entire body were scanned (slice thickness 3 mm, interslice gap 0 mm, field of view 480 mm${\times}$480 mm, resolution 512${\times}$512, T1 weighted), and transferred to the personal computer. Sixty anatomical structures in the MRIs were segmented to make segmented images. Coronal, sagittal MRIs and coronal, sagittal segmented images were made. On the basis of the segmented images, forty-seven anatomical structures 3D images were made by manual surface reconstruction method. Software incorporating the MRIs, segmented images, and 3D images was composed. This learning tool that includes horizontal, coronal, sagittal MRIs of the entire body, corresponding segmented images, 3D images of the anatomical structures in the MRIs, and software is expected to help medical students and doctors study the normal anatomical structures in MRIs. This learning tool will be presented worldwide through Internet or CD titles.

  • PDF

Comparison of finite element analysis of the closing patterns between first and second premolar extraction spaces (상악 제1 및 제2소구치의 발치공간 폐쇄기전에 대한 3차원 유한요소 해석의 비교 연구)

  • Koh, Shin-Ae;Im, Won-Hee;Park, Sun-Hyung;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.407-420
    • /
    • 2007
  • The aim of this study was to compare the differences in closing extraction spaces between maxillary first premolar and second premolar extractions using 3-dimensional finite element analysis (FEA). Methods: Maxillary artificial teeth were selected according to Wheeler's dental anatomy. The size and shape of each tooth, bracket and archwire were made from captured real images by a 3D laser scanner and FEA was performed with a 10-noded tetrahedron. A $10^{\circ}$ gable bend was placed behind the bull loop on a $0.017"{\times}0.025"$ archwire. The extraction space was then closed through 12 repeated activating processes for each 2mm of space. Results and Conclusions: The study demonstrated that the retraction of anterior teeth was less for the second premolar extraction than for the first premolar extraction. The anterior teeth showed a controlled tipping movement with slight extrusion, and the posterior teeth showed a mesial-in rotational movement. For the second premolar extraction, buccal movement of posterior teeth was highly increased.

Microfabrication of submicron-size hole for potential held emission and near field optical sensor applications (전계방출 및 근접 광센서 응용을 위한 서브 마이크론 aperture의 제작)

  • Lee, J.W.;Park, S.S.;Kim, J.W.;M.Y. Jung;Kim, D.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.2
    • /
    • pp.99-101
    • /
    • 2000
  • The fabrication of the submicron size hole has been interesting due to the potential application of the near field optical sensor or liquid metal ion source. The 2 micron size dot array was photolithographically patterned. After formation of the V-groove shape by anisotropic KOH etching, dry oxidation at $1000^{\circ}C$ for 600 minutes was followed. In this procedure, the orientation dependent oxide growth was performed to have an etch-mask for dry etching. The reactive ion etching by the inductively coupled plasma (ICP) system was performed in order to etch ~90 nm $SiO_2$ layer at the bottom of the V-groove and to etch the Si at the bottom. The negative ion energy would enhance the anisotropic etching by the $Cl_2$ gas. After etching, the remaining thickness of the oxide on the Si(111) surface was measured to be ~130 nm by scanning electron microscopy. The etched Si aperture can be used for NSOM sensor.

  • PDF

Effects of Pre-synthesized $BaTiO_3$ Addition on the Microstructure and Dielectric/ Piezoelectric Properties of $(Bi_{0.5}Na_{0.5})_{0.94}Ba_{0.06}TiO_3$ Piezoelectric Ceramics

  • Khansur, Neamul Hayet;Yoon, Man-Soon;Kweon, Soon-Yong;Lee, Young-Geun;Ur, Soon-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.189-189
    • /
    • 2008
  • Due to the environmental issue vast research is going on to replace the widely used lead contented piezoelectric materials. Bismuth sodium titanate (abbreviated as BNT) based bismuth sodium titanate-barium titanate (abbreviated as BNBT) ceramic was prepared by using modified method rather than conventional mixed oxide method. This modification was made to improve the properties of BNT based ceramic. In this procedure $BaTiO_3$ (abbreviated as BT) was prepared using conventional mixed oxide method. Analytical grade raw materials of $BaCO_3$ and $TiO_2$ were weighted and ball milled using ethanol medium. The mixed slurry was dried and sieved under 80 mesh. Then the powder was calcined at $1100^{\circ}C$ for 2 hours. This calcined BT powder was used in the preparation of BNBT. Stoichiometric amount of $Bi_2O_3$, $Na_2CO_3$, $TiO_2$ and BT were weighted and mixed by using ball mill. The used calcination temperature was $850^{\circ}C$ for 2 hours. Calcined powder was taken for another milling step. BNBT disks were pressed to 15 mm of diameter and then cold isostatical press (CIP) was used. Pressed samples were sintered at $1150^{\circ}C$ for 2 hours. The SEM microstructure analysis revealed that the grain shape of the sintered ceramic was polyhedral and grain boundary was well matched where as the sample prepared by conventional method showed irregular arrangement and grain boundary not well matched. And sintered density was better (5.78 g/cc) for the modified method. It was strongly observed that the properties of BNBT ceramic near MPB composition was found to be improved by the modified method compare to the conventional mixed oxide method. The piezoelectric constant dB of 177.33 pC/N, electromechanical coupling factor $k_p$ of 33.4%, dielectric constant $K_{33}^T$ of 688.237 and mechanical quality factor $Q_m$ of 109.37 was found.

  • PDF

Translucency and Color Stability of Various Core Ceramics for All-Ceramic Restoration (전부도재수복물을 위한 수종의 코어 세라믹의 반투명도 및 색 안정성)

  • Oh, Sang-Chun;Lee, Hae-Hyoung;Shin, Mee-Ran;Park, Kwang-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.2
    • /
    • pp.157-170
    • /
    • 2007
  • Purpose: This investigation was designed to determine the translucency and color stability of various core ceramics for all-ceramic restoration using the CIE $L^*a^*b^*$ system. Material and Methods: IPS e.max Press ceramic(Ivoclar-Vivadent, Liechtenstein), $LAVA^{TM}$ All Ceramic(3M-Espe, Germany), Cercon Smart Ceramic(Dentsply, Germany), and Z-match Ceramic(DentAim, Korea) were used for this study. For the specimens of zirconia oxide ceramics, the as-sintered cylindrical blanks($11.0{\times}25.0mm$) were machined into the shape of a disk(0.4, 0.8, 1.5 mm in thickness, 10 mm in diameters) with a diamond grind machine. The IPS e.max Press specimens ($0.8{\times}10mm$) were fabricated using the "lost wax" technique. CIE $L^*a^*b^*$ coordinates and light transmission were recorded for each specimen with a spectrophotometer(CM-2600d, Minolta, Japan). Color differences were calculated using the equation, ${\Delta}E^*ab=[({\Delta}L^*)2+({\Delta}a^*)2+({\Delta}b^*)2]1/2$. Results: The results were obtained as follows: 1. The most translucent group was IPS e.max Press ceramic that is a glass-ceramic, and $Lava^{TM}$ and Z-match ceramic were more translucent than Cercon Smart ceramic in zirconia ceramic group. 2. In the all groups, there was no significant translucent change after 6 times heat-treatments required to make a final restoration. 3. Colored zirconia was showed more yellowish and dark than uncolored zirconia. 4. After heat-pressing, IPS e.max Press ceramic was showed high ${\Delta}E^*ab$ value(4.1 of eM1, 6.8 of eM2) that means to be more whiter than before heat-pressing. However, there was no color change after additive heat treatments for final restoration. 5. In the colored zirconia groups, there was no significant color change after some heat-treatments required to make a final restoration.

Distribution of Bivalve Larvae in Deukryang Bay (득량만에서 조개류 유생의 분포)

  • Kim, Chul-Won;Kwon, Seung-Bai;Hur, Sung-Bum
    • Journal of Aquaculture
    • /
    • v.19 no.4
    • /
    • pp.288-298
    • /
    • 2006
  • Larval distribution of bivalve from 29 stations in Deukryang Bay was examined from May to November in 1995. The abundance of total larvae increased from May ($3,736\;inds/m^3$) and reached maximum in August ($174,616\;inds/m^3$). But it decreased continuously until November ($2,171\;inds/m^3$). D-shape, early umbone and advanced umbone stage larvae composed of 76%, 18% and 6%, respectively, of total bivalve larvae. Nine larval species of bivalve were identified in this study. The mean abundance of Scapharca subcrenata larvae was $14,030\;inds/m^3$, which was 33.5% of total identified larvae. S. broughtonii (16.2%), Crassostrea gigas (12.5%), Mytilus edulis (10.2%) were also major species in order of their abundance. Considering the monthly larval occurrence in Deukryang Bay, main spawning month of bivalves except M. edulis and M. senhausia was estimated as July. Even though the spatial distribution of bivalve larvae in Deukryang Bay was different by the species, the larvae were generally abundant in the inner and west area of the bay, where was shallower and higher water temperature than the entrance and east area of the bay.

High-Order Surface Gradient Coil Design Using Target Field Approach

  • Lee, J.K.;Yang, Y.J.;Jeong, S.T.;Choi, H.J.;Cho, Z.H.;Oh, C.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.19-24
    • /
    • 1996
  • The purpose of this paper is to design high-order (or radial) surface gradient coil (SGC), which can provide multi-dimensional spatial selection. Although the spatial Selection with High-Order gradienT (SHOT) can provide a 2-D selection with only one selective RF pulse, the high-order gradient pro- duced by conventional cylindrical-shape coils has not been clinically useful due to the large selection size caused by the limited radial gradient intensity. However, by using the proposed high-order SGCs located near the imaging region, the size of volume selection can be reduced to a clinically useflll size of 1-2 cm in diameter by applying stronger radial gradient field with much less gradient driving power. So far radial SGCs have been designed by using the field component method and may cause distortion in the selection shapes. In this paper, by using the target field approach for the coil design, selected volumes became almost circular. A 40 cm-by-40 cm $z^2$_surface gradient coil has been designed and implemented by using the target field approach. Phantom and volunteer studies have been performed Experimental results using spatially localized MRI show good agreement to the theoretically predicted behavior.

  • PDF

The Measurements of Energy and Distribution of Scattered Electrons in Therapeutic X-Ray Beam (치료 방사선 선속(Flux)에 포함된 산란전자의 분포와 에너지 측정)

  • Vahc, Young-Woo;Park, Kyung-Ran;Ohyun Kwon;Lee, Yong-Ha;Kim, Tae-Hong;Kim, Sookil
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Accurate knowledge of the distribution of contamination electrons ( which comes from mainly gantry head by Compton scattering, pair production, and tray: henceforth called leptons ) at the surface and in the first centimeters of tissue is essential for the clinical practice of radiation oncology. Such lepton tends to reduce or eliminate the ‘skin-sparing’ advantage of megavoltage photon beam radiotherapy, This information is needed to prescribe a absorbed dose to a skin volume at a few millimeter depth in high energy therapeutic radiation photon beam All experiments were done with 15 MV photon beam from a dual energy linear accelerator (Clinac 1800, Varian). Field size is defined by ranged from 10.0$\times$10.0 to 30.0$\times$30.0 $\textrm{cm}^2$. The absorbed dose and distribution of leptons in therapeutic radiation beam (15 MV) are investigated by means of variable blocked beams of 30.0$\times$30.0 $\textrm{cm}^2$ and dose beam profiles partly removed leptons with a copper plate. A numerous leptons mainly are distributed as shape of broad cone in the central photon beam and leptons path length in the water are shorter than 2.5 cm because of the leptons energy having around 3.0 MeV. These results clearly appears that the subtraction of leptons from the total depth dose curve not only lower the absolute dose in the buildup region and surface dose, it also causes a shift of d$_{max}$ to a deeper depth.

  • PDF