• 제목/요약/키워드: 2-D shape

검색결과 2,492건 처리시간 0.028초

Laser Powder Bed Fusion 공정으로 제조된 Ti-6Al-4V 합금의 형상 차이에 따른 기계적 특성 변화 (Effect of Bulk Shape on Mechanical Properties of Ti-6Al-4V Alloy Manufactured by Laser Powder Bed Fusion)

  • 박하음;김연우;이승연;최중호;유지훈;김정기;박정민
    • 한국분말재료학회지
    • /
    • 제30권2호
    • /
    • pp.140-145
    • /
    • 2023
  • Although the Ti-6Al-4V alloy has been used in the aircraft industry owing to its excellent mechanical properties and low density, the low formability of the alloy hinders broadening its applications. Recently, laser-powder bed fusion (L-PBF) has become a novel process for overcoming the limitations of the alloy (i.e., low formability), owing to the high degree of design freedom for the geometry of products having outstanding performance used in high-tech applications. In this study, to investigate the effect of bulk shape on the microstructure and mechanical properties of L-PBFed Ti-6Al-4V alloys, two types of samples are fabricated using L-PBF: thick and thin samples. The thick sample exhibits lower strength and higher ductility than the thin sample owing to the larger grain size and lower residual dislocation density of the thick sample because of the heat input during the L-PBF process.

치과용 3D 프린팅 기술로 제작된 가공물의 정밀성 분석 (Precision Analysis of Workpieces made with Dental 3D Printing Technology)

  • 최성민
    • 대한치과기공학회지
    • /
    • 제40권4호
    • /
    • pp.231-237
    • /
    • 2018
  • Purpose: The development of the dental technology industry has digitized the dental process. Definition of Digitalization of Dental Implantation Digitalization is the process of model making and prosthodontic processing using 3D CAD and CAM. Currently, it is becoming popular due to the spread of various devices. However, precision evaluation at this stage is an important factor in precision-based dental procedures. Therefore, in this study, we want to analyze the precision of the processed body made with digital dental machine. Methods: The accuracy of digital dental pore devices was evaluated. Specimens were fabricated with 5 types of 3D printers. The external shape was measured with the prepared specimen. The surface roughness was measured. Results: As a result, precision was excellent in order of EP2 specimen, EP1 specimen, and EA2 specimen. The precision of EP3 specimen and EA1 specimen is not excellent. And the precision of the specimen processed with polymer 3D printer is excellent. The accuracy of LCPS type polymer 3D printers is considered to be excellent. Conclusion : 1. Observation of the shape The 3D printer for LCPS system and the 3D printer for SLM $40{\mu}m$ system were found to be precisely processed. 2. Surface roughness results The LCPS system polymer 3D printer has been shown to have a precise surface.

ISO10303 응용프로토콜을 이용한 트러스교의 3차원 형상 및 해석정보 데이터베이스 구축 (Construction of Truss Bridge Database for 3-D Shape and Structural Analysis Information by using ISO10303 Application Protocols)

  • 임승완;김봉근;김효진;이상호
    • 한국재난관리표준학회지
    • /
    • 제2권1호
    • /
    • pp.81-89
    • /
    • 2009
  • 본 연구에서는 트러스 교량의 표준화된 데이터베이스 구축을 통해 웹 환경에서 정보 공유를 실현하는 정보관리 시스템을 개발하였다. 이를 위해, 형상정보는 STEP에서 제시하는 AP 203을 기반으로 데이터 구조를 구성하여 정보를 저장하였으며, 웹상의 3차원 가시화는 Web 3D 기술을 적용하여 구현함으로써 사용자의 편의를 돕고 구조물에 대한 기하학적인 이해를 용이하게 하였다. 해석정보는 AP 209를 사용하여 유한요소해석모델과 해석결과 및 물성 정보를 관계형 데이터베이스에 저장하였다. 구축된 데이터베이스를 기반으로 트러스 교량의 정보관리를 위한 통합된 시범시스템을 개발하였으며, 개발된 시스템은 시방규정 및 안전점검과 같은 제반정보를 형상객체와 연계하여 사용자에게 제공한다.

  • PDF

3D 인체데이터를 활용한 남성 정장재킷 패턴개발 연구 -30대 후반 남성을 중심으로- (A Study on Development of Men's Formal Jacket Pattern by 3D Human Body Scan Data -A Focus on Men's in their Late 30s-)

  • 신경희;서추연
    • 한국의류학회지
    • /
    • 제43권3호
    • /
    • pp.440-458
    • /
    • 2019
  • Based on a 3D body data and pattern comparison analysis, this study developed a formal jacket pattern for men in their late 30s. In order to select the representative type of men in their late 30s, factor analysis and cluster analysis were conducted on data form 319 men, 35 to 39 years old using the anthropometric data from The 7th Size Korea (2015) as the representative body type. The surface of the body surface was developed using a 3D human shape of a male in his 30s in The 6th Size Korea (2010). Then the shape was changed to a flat pattern that confirmed the necessary elements for setting the shape and dimension. Cluster analysis revealed type B as the representative type because it showed the best shape characteristics for men in the late 30s. The drafting method of the final research pattern is as follows. Jacket length: stature/2.5cm, back length: stature/5+8.5cm (constant)], armhole depth: [stature/ 7-1.5cm (constant)], back width: [C/9+9.5cm (constant)]+1cm (ease), front width: [C/9+8.5cm (constant)]+1cm (ease), armscye depth: C/8, front waist darts: 1cm, front closure amount: 2cm.

3D 측정치를 이용한 여성용 모자 패턴 개발 - 6면 크라운 중심으로 - (A Study on Development of the Basic Hat Pattern using 3D Scan Data for Korean Women - Focusing on the 6 pieces Crown -)

  • 김차현;김금화
    • 한국의류산업학회지
    • /
    • 제12권3호
    • /
    • pp.354-363
    • /
    • 2010
  • The purpose of this study was to provide some preliminary results on application of 3D scan data of head shapes to the hat design and pattern-making. This paper defined necessary measurement items and concepts in 3-dimensional images of head shapes. And also it presented the methodology to pattern-making of 6-piece crown hat based on 3D data. It used the data of Size Korea to pick up and choose a head shape model with the average head size of Korean women in their twenties. Main results were: 1. The 3D scan data of head shape was better than the 1 dimensional measurement data. Because I could establish a hat pattern-making theory by the 3D scan data of head. 2. The 3D scan data provided the basis for conceptualization of basic measurement points and items for a better fit of hats as well as the definition of the basic hat circumference. 3. This presented a methodology for analyzing out head shape by 3D scan data, and allowed the derivation of the basic hat circumference from the maximum head circumference. 4. As the 6-piece Crown cloche hat made by this method fitted the head shape model perfectly, this methodology could suggest potential applicability to various hat design.

공차영역을 이용한 대형 2차원 가공물의 형상 검사 (Vision Inspection for Large 2D Machining Product using Tolerance Zone)

  • 이성건;정병묵;조지승
    • 한국정밀공학회지
    • /
    • 제19권11호
    • /
    • pp.112-119
    • /
    • 2002
  • Generally, it is very difficult to inspect geometric shape of large 2D objects after machining. To maintain the accuracy for inspection, a robot vision is used to divide overall shape into several enlarged images, and image processing technique is applied to acquire one minute geometric contour. The inspection is to compare the NC data with the measured contour data by the vision system, and the algorithm is to rotate to minimize the maximum deviation after coinciding two geometric centers. This paper experimentally shows that the proposed algorithm is very useful for inspection of large machined objects.

형태학적 골격에서의 거리 변환을 이용한 2차원 물체 인식 (2-D object recognition using distance transform on morphological skeleton)

  • 권준식;최종수
    • 전자공학회논문지B
    • /
    • 제33B권7호
    • /
    • pp.138-146
    • /
    • 1996
  • In this paper, w epropose a new mehtod to represent the shape and to recognize the object. The shape description and the matching is implemented by using the distance transform on the morphological skeleton. The employed distance transform is the chamfer (3,4) distance transform, because the chamfer distance transform (CDT) has an approximate value to the euclidean distance. The 2-D object can be represented by means of the distribution of the distance transform on the morphological skeleton, the number of skeletons, the sum of the CDT, and the other features are employed as the mtching parameters. The matching method has the invariant features (rotation, translation, and scaling), and then the method is used effectively for recognizing the differently-posed objects and/or marks of the different shape and size.

  • PDF

ISO 15926 기반 플랜트 3D 설계 데이터 가시화를 위한 시스템 개발 (Development of a System for Visualization of the Plant 3D Design Data Based on ISO 15926)

  • 전영준;김병철;문두환
    • 한국CDE학회논문집
    • /
    • 제20권2호
    • /
    • pp.145-158
    • /
    • 2015
  • ISO 15926 is an international standard for the sharing and integration of plant lifecycle information. Plant design data consist of logical configuration, equipment specifications, 2D piping and instrument diagrams (P&IDs), and 3D plant models (shape data). Although 3D computer-aided design (CAD) data is very important data across the plant lifecycle, few studies on the exchange of 3D CAD data using ISO 15926 have been conducted so far. For this, we analyze information requirements regarding plant 3D design in the process industry. Based on the analysis, ISO 15926 templates are defined for the representation of constructive solid geometry (CSG) - based 3D design data. Since system environments for 3D CAD modeling and Semantic Web technologies are different from each other, we present system architecture for processing and visualizing plant 3D design data in the Web Ontology Language (OWL) format. Through the visualization test of ISO 15926-based 3D design data for equipment with a prototype system, feasibility of the proposed method is verified.

물체의 3-D 형상 복원을 위한 삼각측량 시스템 (A Study on the 3-D Information Abstraction of object using Triangulation System)

  • 김국세;이정기;조애리;배일호;이준
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2003년도 춘계학술발표논문집 (상)
    • /
    • pp.409-412
    • /
    • 2003
  • The 3-D shape use to effect of movie, animation, industrial design, medical treatment service, education, engineering etc... But it is not easy to make 3-D shape from the information of 2-D image. There are two methods in restoring 3-D video image through 2-D image; First the method of using a laser; Second, the method of acquiring 3-D image through stereo vision. Instead of doing two methods with many difficulties, I study the method of simple 3-D image in this research paper. We present here a simple and efficient method, called direct calibration, which does not require any equations at all. The direct calibration procedure builds a lookup table(LUT) linking image and 3-D coordinates by a real 3-D triangulation system. The LUT is built by measuring the image coordinates of a grid of known 3-D points, and recording both image and world coordinates for each point; the depth values of all other visible points are obtained by interpolation.

  • PDF

3차원 자동체형계측기 정밀도 검사 (An Accuracy Analysis of the 3D Automatic Body Measuring Machine)

  • 전수형;권석동;박세정;김정양;송정훈;김현진;김종원
    • 사상체질의학회지
    • /
    • 제20권1호
    • /
    • pp.42-47
    • /
    • 2008
  • 1. Objectives The Body Shape and Feature is one of the important standard for classification of Sasang Constitutions. In order to evaluate one's Body Shape and Feature objectively we have been developing the Body Measuring Machine. Now we develop the 3D Automatic Body Measuring Machine(3D-ABMM). So we make an analysis of the 3D-ABMM's Accuracy. 2. Methods By using the 3D-ABMM and Vivid 9i(3D laser scanner, Konica Minolta) we have a surface scan of the three objects which are the upper body of the female and male Manikin and a male model. We overlap each scan data using the RapidForm2006 (3D scan data solution, INUS Technology) and calculate the average distance and standard deviation between the same point of each scan data. 3. Results and Conclusions In the female Manikin, the average distance is 0.84mm and the standard deviation is 1.16mm and the maximum distance is 10.68mm. In the male Manikin, the average distance is 1.12mm and the standard deviation is 1.19mm and the maximum distance is 12.00mm. In the male model, the average distance is 3.26mm and the standard deviation is 2.59mm and the maximum distance is 12.75mm. From the results, 3D-ABMM has good accuracy for scanning body and will be a usable hardware of the 3D Automatic Body Analysis Machine.

  • PDF