• Title/Summary/Keyword: 2-D LC MS/MS

Search Result 184, Processing Time 0.041 seconds

Toxicokinetics of CJ-11555: Gender Difference and Minimum Accumulation

  • Kim, Il-Hwan;Noh, Hyun-Jung;Park, Jae-Mook;Kim, Deog-Yeor;Park, Jie-Eun;Lee, Sung-Hak;Kim, Taek-Rho;Kim, Jin-Wan;Kim, Young-Hoon
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.243.2-244
    • /
    • 2003
  • Purpose: This study evaluated gender differences and extents of accumulation on chronic dose of CJ-1l555 using rats. Method: 0, 10, 50 and 200 mg/kg/day of CJ-11555 (0.5% CMC) were orally administered to rats for 28 days and observed toxicokinetic parameters. Plasma concentrations were analyzed by LC-MS/MS Result: Exposure to CJ-11555 increased with the increase in dose level for both sexes. Mean concentrations at 10 and 50 mg/kg/day were generally similar an Days 1 and 28, but were generally highter on Day 28 than on Day 1 at 200 mg/kg/day. (omitted)

  • PDF

Vitamin D analysis in the Korean total diet study and UV/sun light irradiated mushrooms (한국형 총식이조사 및 UV/태양광 조사 버섯에서의 비타민 D 분석)

  • Min-Jeong Seo;In-Hwa Roh;Jee-Yeon Lee;Sung-Ok Kwon;Cho-Il Kim;Gae-Ho Lee
    • Food Science and Preservation
    • /
    • v.30 no.1
    • /
    • pp.109-121
    • /
    • 2023
  • This study was conducted to evaluate vitamin D intake of Koreans in a total diet study (TDS) and to determine the effect of irradiation on vitamin D synthesis in mushrooms. For analysis, sample were saponified and extracted with hexane, and vitamin D was quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Based on the validation results, the recovery of the National Institute of Standards and Technology (NIST) standard reference sample (SRM) 1849a was 96.7% and the z-score of -1.6 was obtained by the Food Analysis Performance Assessment Scheme (FAPAS) proficiency test (PT) 21115. Vitamin D2 was not detected in any samples, and the highest level of vitamin D3 was detected in mackerel and anchovies ranging from 24.2 to 120.2 ㎍/kg. The mean daily intake of vitamin D was 0.99 ㎍/day, as estimated from the vitamin D contents of the analyzed foods and their corresponding intake. The adequate intake (AI) of vitamin D based on the Dietary reference intakes for Koreans provided by the Ministry of Health and Welfare is 5-15 ㎍/day for Koreans aged 6 to 75 years. Compared with this AI, vitamin D intake of Koreans estimated in this study was inadequate. For that, the increased vitamin D content in ultraviolet (UV)/sun light irradiated mushrooms warrants further research to increase vitamin D intake of Koreans through diet.

Development of Simultaneous Analytical Method of Veterinary Antibiotics in Manure using Liquid Chromatography Coupled with Tandem Mass Spectrometry (LC-MS/MS를 이용한 퇴비 및 액비 중 항생제 동시 분석법 개발)

  • Chung, Hyung Suk;Lee, Young Jun;Lee, Han Sol;Rahman, Md. Musfiqur;Kabir, Md. Humayun;Park, Byung-Jun;Kim, Jang-Eok;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.3
    • /
    • pp.201-210
    • /
    • 2017
  • BACKGROUND: The current study was to monitor of 9 veterinary antibiotics (ceftiofur, clopidol, florfenicol, sulfamethazine, sulfamethoxazole, sulfathiazole, tetracycline, tiamulin, and tylosin) in manure using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive and negative electrospray ionization mode. METHODS AND RESULTS: Sample preparation was carried out using Mcllvaine buffer and citrate salts to adjust the pH of the sample followed by purification with dispersive solid phase extraction (d-SPE). Separation of analytes during LC-MS/MS analysis was conducted using an Eclipse Plus $C_{18}$ column and the mobile phase was in gradient mode with, 0.1% formic acid and 5 mM ammonium formate in methanol (A) and 0.1% formic acid and 5 mM ammonium formate in distilled water (B). The linearity of the matrix-matched calibrations of all tested antibiotics was good, with $R^2$ determination coefficients ${\geq}0.9920$. The limit of detection (LOD) and quantifications (LOQ) were $0.1-67.0{\mu}g/kg$ and $0.4-200.0{\mu}g/kg$, respectively. Analysis of 13 solid and liquid manure samples taken from the Republic of Korea revealed concentrations less than $0.7{\mu}g/kg$ for tiamulin, $1497.6{\mu}g/kg$ for sulfamethazine. CONCLUSION: To monitor 9 veterinary antibiotics from manure samples in 13 provincial areas throughout the Republic of Korea, an analytical method was developed. The developed method was fully validated and successfully applied for monitoring various veterinary antibiotics in manure samples.

Improvement of an Analytical Method for Methoprene in Livestock Products using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 살충제 메토프렌의 잔류분석법 개선)

  • Park, Eun-Ji;Kim, Nam Young;Park, So-Ra;Lee, Jung Mi;Jung, Yong Hyun;Yoon, Hae Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • The research aims to develop a rapid and easy analytical method for methoprene using liquid chromatography-tandem mass spectrometry (LC-MS/MS). A simple, highly sensitive, and specific analytical method for the determination of methoprene in livestock products (beef, pork, chicken, milk, eggs, and fat) was developed. Methoprene was effectively extracted with 1% acetic acid in acetonitrile and acetone (1:1), followed by the addition of anhydrous magnesium sulfate (MgSO4) and anhydrous sodium acetate. Subsequently, the lipids in the livestock sample were extracted by freezing them at -20℃. The extracts were cleaned using MgSO4, primary secondary amine (PSA), and octadecyl (C18), which were then centrifuged to separate the supernatant. Nitrogen gas was used to evaporate the supernatant, which was then dissolved in methanol. The matrix-matched calibration curves were constructed using 8 levels (1, 2.5, 5, 10, 25, 50, 100, 150 ng/mL) and the coefficient of determination (R2) was above 0.9964. Average recoveries spiked at three levels (0.01, 0.1, and 0.5 mg/kg), and ranged from 79.5-105.1%, with relative standard deviations (RSDs) smaller than 14.2%, as required by the Codex guideline (CODEX CAC/GL 40). This study could be useful for residue safety management in livestock products.

Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, ong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • An analytical method was developed for the determination of oxytetracycline in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After the samples were extracted with methanol, the extracts were adjusted to pH 4 by formic acid and sodium chloride was added to remove water. Dispersive solid phase extraction (d-SPE) cleanup was carried out using $MgSO_4$ (anhydrous magnesium sulfate), PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed with LC-MS/MS using ESI (electrospray ionization) in positive ion MRM (multiple reaction monitoring) mode. The matrix-matched calibration curves were constructed using six levels ($0.001{\sim}0.25{\mu}g/mL$) and coefficient of determination ($r^2$) was above 0.99. Recovery results at three concentrations (LOQ, $10{\times}LOQ$, and $50{\times}LOQ$, n=5) were from 80.0 to 108.2% with relative standard deviations (RSDs) less than of 11.4%. For inter-laboratory validation, the average recovery was in the range of 83.5~103.2% and the coefficient of variation (CV) was below 14.1%. All results satisfied the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for oxytetracycline determination in agricultural commodities. This study could be useful for safety management of oxytetracycline residues in agricultural products.

Development of analytical method for determination of spinetoram residues in livestock using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 Spinetoram 공정시험법 개발 및 검증)

  • Ko, Ah-Young;Kim, Heejung;Do, Jung Ah;Jang, Jin;Lee, Eun Hyang;Ju, Yun Ji;Kim, Ji Young;Chang, Moon-Ik;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.94-103
    • /
    • 2016
  • An analytical method was developed to determine the amount of spinetoram (spinetoram J and spinetoram L) in livestock samples. The spinetoram was extracted with acetonitrile and purified through a primary secondary amine (PSA) sorbent. The spinetoram residues were then quantified and confirmed using a liquid chromatography–tandem mass spectrometer (LC-MS/MS) in the positive ion mode using multiple reactions monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005-0.5 mg/kg) into a blank extract with r2 > 0.994. The limits of detection and quantification were 0.002 and 0.01 mg/kg, respectively. The recovery results of spinetram ranged between 81.9-106.4% at different concentration levels (LOQ, 10LOQ, 50LOQ, n=5) with relative standard deviations (RSDs) less than 10%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL40, 2003). An interlaboratory study was conducted to validate the method. The proposed analytical method proved to be accurate, effective, and sensitive for spinetoram determination. The method will be used as an official analytical method in Korea.

Quantitative Proteomics Towards Understanding Life and Environment

  • Choi, Jong-Soon;Chung, Keun-Yook;Woo, Sun-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.4
    • /
    • pp.371-381
    • /
    • 2006
  • New proteomic techniques have been pioneered extensively in recent years, enabling the high-throughput and systematic analyses of cellular proteins in combination with bioinformatic tools. Furthermore, the development of such novel proteomic techniques facilitates the elucidation of the functions of proteins under stress or disease conditions, resulting in the discovery of biomarkers for responses to environmental stimuli. The ultimate objective of proteomics is targeted toward the entire proteome of life, subcellular localization biochemical activities, and the regulation thereof. Comprehensive analysis strategies of proteomics can be classified into three categories: (i) protein separation via 2-dimensional gel electrophoresis (2-DE) or liquid chromatography (LC), (ii) protein identification via either Edman sequencing or mass spectrometry (MS), and (iii) proteome quantitation. Currently, MS-based proteomics techniques have shifted from qualitative proteome analysis via 2-DE or 2D-LC coupled with off-line matrix assisted laser desorption ionization (MALDI) and on-line electrospray ionization (ESI) MS, respectively, toward quantitative proteome analysis. In vitro quantitative proteomic techniques include differential gel electrophoresis with fluorescence dyes. protein-labeling tagging with isotope-coded affinity tags, and peptide-labeling tagging with isobaric tags for relative and absolute quantitation. In addition, stable isotope-labeled amino acids can be in vivo labeled into live culture cells via metabolic incorporation. MS-based proteomics techniques extend to the detection of the phosphopeptide mapping of biologically crucial proteins, which ale associated with post-translational modification. These complementary proteomic techniques contribute to our current understanding of the manner in which life responds to differing environment.

Comprehensive proteome analysis using quantitative proteomic technologies

  • Kamal, Abu Hena Mostafa;Choi, Jong-Soon;Cho, Yong-Gu;Kim, Hong-Sig;Song, Beom-Heon;Lee, Chul-Won;Woo, Sun-Hee
    • Journal of Plant Biotechnology
    • /
    • v.37 no.2
    • /
    • pp.196-204
    • /
    • 2010
  • With the completion of genome sequencing of several organisms, attention has been focused to determine the function and functional network of proteins by proteome analysis. The recent techniques of proteomics have been advanced quickly so that the high-throughput and systematic analyses of cellular proteins are enabled in combination with bioinformatics tools. Furthermore, the development of proteomic techniques helps to elucidate the functions of proteins under stress or diseased condition, resulting in the discovery of biomarkers responsible for the biological stimuli. Ultimate goal of proteomics orients toward the entire proteome of life, subcellular localization, biochemical activities, and their regulation. Comprehensive analysis strategies of proteomics can be classified as three categories: (i) protein separation by 2-dimensional gel electrophoresis (2-DE) or liquid chromatography (LC), (ii) protein identification by either Edman sequencing or mass spectrometry (MS), and (iii) quanitation of proteome. Currently MS-based proteomics turns shiftly from qualitative proteome analysis by 2-DE or 2D-LC coupled with off-line matrix assisted laser desorption ionization (MALDI) and on-line electrospray ionization (ESI) MS, respectively, to quantitative proteome analysis. Some new techniques which include top-down mass spectrometry and tandem affinity purification have emerged. The in vitro quantitative proteomic techniques include differential gel electrophoresis with fluorescence dyes, protein-labeling tagging with isotope-coded affinity tag, and peptide-labeling tagging with isobaric tags for relative and absolute quantitation. In addition, stable isotope labeled amino acid can be in vivo labeled into live culture cells through metabolic incorporation. MS-based proteomics extends to detect the phosphopeptide mapping of biologically crucial protein known as one of post-translational modification. These complementary proteomic techniques contribute to not only the understanding of basic biological function but also the application to the applied sciences for industry.

Simultaneous Identification/Determination System for Sildenafil, Homosildenafil, Vardenafil and Tadalafil as Adulterants in Foods (식품중 불법함유된 발기부전치료제 성분 검출을 위한 동시분석법 연구)

  • Jang, Jae-Hee;Park, Kun-Sang;Park, Hye-Kyung;Koo, Yong-Eui;Choi, Youn-Ju;Hwang, In-Kyung;Kim, Dai-Byung
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.4
    • /
    • pp.195-201
    • /
    • 2003
  • An easily available, simultaneous identification/determination procedure for sildenafil, homosildenafil, tadalafil, vardenafil in adulterated health related foods was established by using a combination of three different analytical methods; thin layer chromatography(TLC), liquied chromatography-mass spectrometry (LC/MS) and high-performance liquied chromatography (HPLC)/photo-diode-array detector. The sample solution for TLC was applied to silica gel 60 $F_{254}$ plates with ethylacetate/acetonitrile/25%ammonia (90:10:5) as a developing solvent. Spots were located under UV radiation at 254 nm and dragendolfs reagent. Mass spectra of the compounds by LC/MS were investigated with electrospray ionization (ESI) interface, under positive ion mode. The HPLC analysis was performed on a column of capcell pack $C_{18}$ (UG120, 4.6${\times}$250mm I.D. 5 ${\mu}$m)with 0.1% sodium 1-hexansulfonate (in 0.1% phosphoric acid)/acetnitrile (73:27) as a mobile phase, and effluent was minitored with a photo-diode-applied to commercial foods, Sildenafil content was inthe range of 0.4mg/g~360.9 mg/g from 7 out of 35 samples. Homosildenafil content was in the range of 2.2 mg/g~336.0 mg/g from 7 out of 35 samples. Tadalafil content was 429.3 mg/g, 9.6 mg/500 mg from 2 out of 35 samples. The procedure described here is available for the screening of sildenafil, homosildenafil, tadalafil, vardenafil.

Six Sigma Analysis of Vitamin D Measurement Using External Quality Assessment Program (외부정도관리 프로그램을 이용한 비타민 D 검사의 6 시그마 분석)

  • Ji, Myungsuk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.2
    • /
    • pp.91-97
    • /
    • 2020
  • Standardization of vitamin analysis continues around the world, and much effort has been made to improve the accuracy of the results. This study analyzed the sigma metrics of the vitamin D test using the external quality assessment (EQA) program. Sigma metrics is used for quantitative tests performed in the laboratory, and the test results can be objectively visualized in terms of quality. This analysis was performed based on the accuracy of the College of American Pathologists (CAP) using the results of the 2019 accuracy-based vitamin D (ABVD) survey, and about 300 laboratories participated in the survey. Reference values were obtained by the Center for Disease Control and Prevention (CDC) reference laboratory. At six different concentrations, the sigma metrics were analyzed to be 1.00, 1.85, 2.42, 1.01, 1.54 and 0.78, respectively. An average of 1.43 sigma metrics was determined. In particular, only positive biases for ABVD-16 and 17 were shown in the liquid chromatography tandem-mass spectrometry (LC-MS/MS), which is the standard method for vitamin D determination when compared to the reference values. The causes of the difference can be explained by cross reactivity to various vitamin D metabolites. Laboratories need to improve their overall performance.