• Title/Summary/Keyword: 2-자유도 시스템

Search Result 454, Processing Time 0.034 seconds

A Study on Development ATCS of Transfer Crane using Neural Network Predictive Control (신경회로망 예측제어에 의한 Transfer Crane의 ATCS 개발에 관한 연구)

  • 손동섭;이진우;이영진;이권순
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.11a
    • /
    • pp.113-119
    • /
    • 2002
  • Recently, an automatic crane control system is required with high speed and rapid transportation. During the operation of crane system in container yard it is necessary to control the crane trolley position and loop length so that the swing of the hanging container is minimized We can do development of unmanned automation control system using automation travel control technique and anti-sway technique in crane system. Therefore, we designed a controller for Automation travel control to control the transfer crane system. Analyzed crane system through simulation, and proved excellency of control performance than other conventional controllers.

  • PDF

차량 탑재용 항법 장치의 기술 동향

  • 이수영;김병우
    • ICROS
    • /
    • v.2 no.2
    • /
    • pp.66-70
    • /
    • 1996
  • 현재 차량 항법 장치는 최근 급속하게 발달한 전자기술을 활용하여 단순한 차량의 자유이동 기능에서 운전자에게 안전성, 효율성, 편의성, 가격 등을 보장할 뿐만 아니라 운전자에게 경로를 안내하거나 교통 정보를 제공하는 정보 제공 장치로 도약하고 있다. 그러나 앞으로 이같은 단순 정보 전달 기능을 초월하여 보다 효율적이고 안전한 운행이 가능한 지능적인 기능을 수행케 될 것이다. 즉, 도로상의 센서와 같은 교통 정보 수집체계와 통신체계 등을 활용하여 실시간 교통 상황 정보를 제공하여 쾌적한 추행환경 및 차량 제어 시스템과 연계하여 안전주행에 기여할 수 있다.

  • PDF

Parameter Estimation of Dynamic System Based on UKF (UKF 기반한 동역학 시스템 파라미터의 추정)

  • Seung, Ji-Hoon;Chong, Kil-To
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.772-778
    • /
    • 2012
  • In this paper, the states and the parameters in the dynamic system are simultaneously estimated by applying the UKF(Unscented Kalman Filter), which is widely used for estimating the state of non-linear systems. Estimating the parameter is very important in various fields, such as system control, modeling, analysis of performance, and prediction. Most of the dynamic systems which are dealt with in engineering have non-linearity as well as some noise. Therefore, the parameter estimation is difficult. This paper estimates the states and the parameters applying to the UKF, which is a non-linear filter and has strong noise. The augmented equation is used by including the addition of the parameter factors to the original state equation of the system. Moreover, it is simulated by applying to a 2-DOF(Degree of Freedom) dynamic system composed of the pendulum and the slide. The measurement noise of the dynamic equation is assumed to be a Gaussian distribution. As the simulation results show, the proposed parameter estimation performs better than the LSM(Least Square Method). Furthermore, the estimation errors and convergence time are within three percent and 0.1 second, respectively. Consequentially, the UKF is able to estimate the system states and the parameters for the system, despite having measurement data with noise.

Effective Interference Alignment for Device-to-Device Communication Underlaid in Multi-Cell Interference Network (다중셀 간섭 네트워크와 중첩된 D2D 통신을 위한 효과적인 간섭 정렬 기법)

  • Qu, Xin;Kang, Chung Gu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.3
    • /
    • pp.161-163
    • /
    • 2014
  • We consider the device-to-device (D2D) communication underlaying multi-cell interference system, in which the cellular downlink (DL) resource is reused by K cells and two D2D transmission links within each cell. In this paper, it has been shown that the downlink intra-cell and inter-cell interference can be effectively handled by interference alignment (IA) technique, as long as the simultaneous D2D links are properly selected or power-controlled so that they may not incur interference to the base stations in the same and neighbor cells. In particular, we provides the IA technique that can achieve the theoretically maximum possible degree of freedom (DOF), demonstrating that a total of (K+1)M degrees of freedom (DOFs) can be achieved for K-cell interference system with two underlaying D2D links, where base stations, cellular UE's, and D2D UE's all have M transmit and receive antennas.

On the Flow Characteristics around a Circular Cylinder according as the Water Depth from the Free Surface (자유수면에 인접한 원형실린더형 몰수체 주위의 유동특성에 관한 연구)

  • Gim, Ok-Sok;Shon, Chang-Bae;Lee, Gyoung-Woo
    • Journal of Navigation and Port Research
    • /
    • v.34 no.5
    • /
    • pp.331-336
    • /
    • 2010
  • The free surface influenced the wake behind a circular cylinder and its effects were investigated experimentally in a circulating water channel with the variation of water depth. Instantaneous velocity fields were measured in this paper. The measured results has been compared with each other to investigate the flow characteristics of the circular cylinder's 2-dimensional section at $Re=1.0{\times}10^3$ using 2-frame grey level cross correlation PIV method. The flow around the circular cylinder with free surface affected the wake structure. Especially, in case of d=1.0D, the boundary layer was measured in the whole area. The separation point and boundary layer of the circular cylinder could be controlled by the water depth.

Evaluation of the Usefulness of the Respiratory Guidance System in the Respiratory Gating Radiation Therapy (호흡동조 방사선치료 시 호흡유도시스템의 유용성 평가)

  • Lee, Yeong-Cheol;Kim, Sun-Myung;Do, Gyeong-Min;Park, Geun-Yong;Kim, Gun-Oh;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.167-174
    • /
    • 2012
  • Purpose: The respiration is one of the most important factors in respiratory gating radiation therapy (RGRT). We have developed an unique respiratory guidance system using an audio-visual system in order to support and stabilize individual patient's respiration and evaluated the usefulness of this system. Materials and Methods: Seven patients received the RGRT at our clinic from June 2011 to April 2012. After breathing exercise with the audio-visual system, we measured their spontaneous respiration and their respiration with the audio-visual system respectively. With the measured data, we yielded standard deviations by the superficial contents of respiratory cycles and functions, and analyzed them to examine changes in their breathing before and after the therapy. Results: The PTP (peak to peak) of the standard deviations of the free breathing, the audio guidance system, and the respiratory guidance system were 0.343, 0.148, and 0.078 respectively. The respiratory cycles were 0.645, 0.345, and 0.171 respectively and the superficial contents of the respiratory functions were 2.591, 1.008, and 0.877 respectively. The average values of the differences in the standard deviations among the whole patients at the CT room and therapy room were 0.425 for the PTP, 1.566 for the respiratory cycles, and 3.671 for the respiratory superficial contents. As for the standard deviations before and after the application of the PTP respiratory guidance system, that of the PTP was 0.265, that of the respiratory cycles was 0.474, and that of the respiratory superficial contents. The results of t-test of the values before and after free breathing and the audio-visual guidance system showed that the P-value of the PTP was 0.035, that of the cycles 0.009, and that of the respiratory superficial contents 0.010. Conclusion: The respiratory control could be one of the most important factors in the RGRT which determines the success or failure of a treatment. We were able to get more stable breathing with the audio-visual respiratory guidance system than free breathing or breathing with auditory guidance alone. In particular, the above system was excellent at the reproduction of respiratory cycles in care units. Such a system enables to reduce time due to unstable breathing and to perform more precise and detailed treatment.

  • PDF

Quasi-breath-hold (QBH) Biofeedback in Gated 3D Thoracic MRI: Feasibility Study (게이트 흉부자기 공명 영상법과 함께 사용할 수 있는 의사호흡정지(QBH) 바이오 피드백)

  • Kim, Taeho;Pooley, Robert;Lee, Danny;Keall, Paul;Lee, Rena;Kim, Siyong
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.72-78
    • /
    • 2014
  • The aim of the study is to test a hypothesis that quasi-breath-hold (QBH) biofeedback improves the residual respiratory motion management in gated 3D thoracic MR imaging, reducing respiratory motion artifacts with insignificant acquisition time alteration. To test the hypothesis five healthy human subjects underwent two gated MR imaging studies based on a T2 weighted SPACE MR pulse sequence using a respiratory navigator of a 3T Siemens MRI: one under free breathing and the other under QBH biofeedback breathing. The QBH biofeedback system utilized the external marker position on the abdomen obtained with an RPM system (Real-time Position Management, Varian) to audio-visually guide a human subject for 2s breath-hold at 90% exhalation position in each respiratory cycle. The improvement in the upper liver breath-hold motion reproducibility within the gating window using the QBH biofeedback system has been assessed for a group of volunteers. We assessed the residual respiratory motion management within the gating window and respiratory motion artifacts in 3D thoracic MRI both with/without QBH biofeedback. In addition, the RMSE (root mean square error) of abdominal displacement has been investigated. The QBH biofeedback reduced the residual upper liver motion within the gating window during MR acquisitions (~6 minutes) compared to that for free breathing, resulting in the reduction of respiratory motion artifacts in lung and liver of gated 3D thoracic MR images. The abdominal motion reduction in the gated window was consistent with the residual motion reduction of the diaphragm with QBH biofeedback. Consequently, average RMSE (root mean square error) of abdominal displacement obtained from the RPM has been also reduced from 2.0 mm of free breathing to 0.7 mm of QBH biofeedback breathing over the entire cycle (67% reduction, p-value=0.02) and from 1.7 mm of free breathing to 0.7 mm of QBH biofeedback breathing in the gated window (58% reduction, p-value=0.14). The average baseline drift obtained using a linear fit was reduced from 5.5 mm/min with free breathing to 0.6 mm/min (89% reduction, p-value=0.017) with QBH biofeedback. The study demonstrated that the QBH biofeedback improved the upper liver breath-hold motion reproducibility during the gated 3D thoracic MR imaging. This system can provide clinically applicable motion management of the internal anatomy for gated medical imaging as well as gated radiotherapy.

Design of a Robust Controller of Robot Manipulators Using Vision System (비젼 시스템을 이용한 로봇 매니퓰레이터의 강인 제어기 설계)

  • Lee Young Chan;Jie Min Seok;Baek Joong Hwan;Lee Kang Woong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.1
    • /
    • pp.9-16
    • /
    • 2004
  • In this paper, we propose a robust controller for robot manipulators with parametric uncertainties using feature-based visual servo control system. In order to improve trajectory error of the robot manipulators due to the parameter variation, integral action is included in the dynamic control of part in inner subroutine of the control system. This integral action also reduces feature error in the steady state. The stability analysis of the closed-loop system is shown by the Lyapunov method. The effectiveness of the proposed method is shown by simulation and experimental results on the 5 link robot manipulator with two degree of freedom.

On the structure of a discrete-time $H_{\infty}$ two-degrees-of-freedom controller (이산시간 $H_{\infty}$ 2-자유도 제어기의 구조에 관한 연구)

  • 최병욱
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.569-572
    • /
    • 1996
  • Explicit state-space formulate for an H$_{.inf}$ based two-degrees-of-freedom robust controller are derived in discrete-time. The controller provides robust stability against coprime factor uncertainty, and a degree of robust performance in the sense of making the closed-loop system match a prespecified reference model. It is shown that the controller consists of a plant observer, the chosen reference model, and a generalized state feedback law associated with the plant and model states. The controller structure is shown to be relatively simple and thus may reduce the computational load on the digital control processor.

  • PDF