• Title/Summary/Keyword: 2층 누수대수층

Search Result 15, Processing Time 0.026 seconds

The Scale-dependent of Hydraulic Conductivity in Leaky Confined Aquifer with High Permeability at the Ttaan Isle, Gimhae City (김해 딴섬의 고투수성 누수 피압대수층에서 수리전도도의 규모종속효과)

  • Kim, Tae-Yeong;Kang, Dong-Hwan;Kim, Sung-Soo;Kim, Byung-Woo;Kwon, Byung-Hyuk
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.415-422
    • /
    • 2008
  • Pumping test was conducted to understand hydraulic conductivity for leaky confined aquifer with high permeability. Test aquifer was formed in $25{\sim}35\;m$ below ground surface at predetermined site of riverbank filtration which junction of Nakdong river and Milyang river in the Ttaan isle, Gimhae city, Korea Monitoring wells were located at intervals of 2 m and 5 m from pumping well in south-west direction (MW1 and MW2 wells) and northeast direction (MW3 and MW4 wells), respectively. Pumping test was continuously conducted for constant pumping rate of $2,500m^3/day$, hydraulic conductivity was estimated using AQTESOLV 3.5 program. Hydraulic conductivity were estimated to be $1.745{\times}10^{-3}m/sec$ for pumping well (PW), $2.452{\times}10^{-3}m/sec$ for between PW and MW1 wells, $2.161{\times}10^{-3}m/sec$ for between PW and MW2 wells, $2.270{\times}10^{-3}m/sec$ for between PW and MW3 wells and $2.591{\times}10^{-3}m/sec$ for between PW and MW4 wells. The function of hydraulic conductivity (K) as monitoring distance (d) were estimated to be logK = 0.0693logd - 2.671 for south-west direction (PW-MW1-MW2 line), logK = 0.0817logd - 2.655 for north-east direction (PW-MW3-MW 4 line). Scale exponent of hydraulic conductivity as test volume was estimated using Schulze-Makuch et al.(1999) method. Scale exponent of this aquifer was estimated to be 0.15. It means that test aquifer has very low heterogeneity. The radius of influence estimated using transmissivity, maximum groundwater level displacement, distance from pumping well and pumping rate during pumping test were 7.148 m for south-west direction and 6.912 m for north-east direction. The increasing rate of hydraulic conductivity from pumping well to maximum radius of influence were estimated to be 1.40 times for south-west direction and 1.49 times for north-east direction. Thus, heterogeneity of test aquifer was a little higher in north-east direction.

Fractal Model of Transient Flow in a Dual-porosity Aquifer with Constant-head Upper Boundary (일정수두 상부경계를 가지는 이중공극 대수층내 부정류에 관한 프락탈모델)

  • 함세영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.95-102
    • /
    • 1997
  • So far, several fractal models of fluid flow in a fractured aquifer have been developed. In this study, a new fractal model is derived that considers transient flow in the dual-porosity aquifer with the fracture skin between the fissure and the block, and the storage capacity and the wellbore skin on the pumping well. Constant-head upper boundary is specified in the block. This model is a generalized one which comprises both modified Hantush equation (1960) and Boulton-Streltsova equation (1978). Type curves are plotted for different flow dimensions (0.5, 1, 1.5, 2, 2.5 and 3) with various values of the leakage factor and the fracture skin. They show dimensionless drawdown in the pumping well and observation wells located either in the fissure system or in the matrix block.

  • PDF

Hydraulic Properties of Duksan Hot-spring Area (덕산온천 지역의 수리적 성질)

  • 함세영;조병욱;성익환
    • The Journal of Engineering Geology
    • /
    • v.9 no.2
    • /
    • pp.101-118
    • /
    • 1999
  • The pumping test analysis on 28 pumping test data in Duksan hot-spring area was performed using the fractal model, the leaky fractal model, and the steady-state dual-porosity fractal model. The fractional flow dimension 1.9 or 2.0 was determined in the central put of the hot spring and the fractional flow dimension 1.5-1.7 in the marginal area. For the flow dimension 2.0, the correlation between the transmissivity and the productivity index by the aquifer loss was much better than that between the transmissivity and the specific yield by the total drawdown. On the other hand, for the flow dimension 1.9, the correlation between the generalized transmissivity and the productivity index was very similar to that between the generalized transmissivity and the specific yield.

  • PDF

Analysis of Aquifer Test Data in Fractured Aquifers and the Application of the Generalized Radial Flow (균열암반에서의 양수시험자료 해석과 일반 방사상 유동모델의 적용성 연구)

  • Seong Hyeonjeong;Kim Yongie;Lee Chul-Woo;Kim Kue-Young;Woo Nam-Chil
    • Economic and Environmental Geology
    • /
    • v.38 no.2 s.171
    • /
    • pp.177-185
    • /
    • 2005
  • Data from 122 pumping tests were obtained from 100 boreholes in granites, volcanic rocks, metamorphic rocks, and Cretaceous and Tertiary sedimentary rocks, and then were analyzed using AQTESOLV. Results from 86 of the 122 tests ($71\%$) have an analytical solution corresponding to Theis (1935), Cooper-Jacob (1946), Papadopulos-Cooper (1967), Hantush (1962), Moench (1985), or Hantush-Jacob (1955), whereas the remaining 36 results ($29.5\%$) do not correspond to any of the analytical methods. Of the 86 results, only 17 match the Theis and Cooper-Jacob methods, indicating that the basic methods fer pumping test analysis are useful far only $14\%$ of the total data. This suggests that analytical solutions derived using leaky boundary conditions are appropriate for the analysis of pumping test data in fractured aquifers in this study. Furthermore, the results show the importance of carefully selecting an appropriate model for the analysis of pumping test data. Results from the 122 pumping tests were also analyzed using the GRF model. Using the Barker method, the results show that 77 of the 122 tests ($63\%$) have dimensions ranging between 1.1-2.9. Of these 77 solutions, ($39(44.2{\%})$) have a fractional dimension of 1.1-1.9, ($26(6.5{\%})$) show 2-dimensional radial flow also applicable to the Theis method, and ($38(49.3{\%})$) have dimensions of 2.1-2.9. The results show that groundwater flows according to a fractional flow dimension in fractured aquifers.

A Study on the Variation of the Surface and Groundwater Flow System Related to the Tunnel Excavation in DONGHAE Mine Area (II) - Hydrogeochemical Consideration (동해신광산 터널굴착공사와 관련된 지표수 및 지하수의 유동변화에 대한 조사연구 (II)-수리지구화학적 고찰)

  • 전효택;이희근;이종운;이대혁;류동우;오석영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.1
    • /
    • pp.27-40
    • /
    • 1997
  • The hydrogeochemical study on the 15 natural waters was carried out in the vicinity of tunnel excavation site of Donghae largely composed of granite and limestone. The water samples can be classified based on their chemical characteristics into two groups; waters draining in the granitic region(group 1) and the limestone region(group 2). This classification was also confirmed by statistical examination through cluster analysis, and the tunnel seepage waters collected at the same site appear to be included in group 1 and 2 by their sampling period, respectively. According to factor analysis, the waters of group 1 art mainly represented by the weathering of plagioclase to kaolinite and those of group 2 are characterized by the dissolution of calcite. Different properties of the tunnel seepage waters are thought to be resulted from the effective waterproofing processes conducted during the sampling interval to the surface and subsurface leakage zones at the granitic region, which contributed to the change of groundwater flow system. However both the tunnel seepage waters seem to have thermodynamically interacted with rock-forming minerals in their wallrocks. The mixing ratio of the waters from two groups and water-rock interactions are evaluated quantitatively for the tunnel seepage waters through the mass balance approach, and the results are identical with the previous conclusions in this study.

  • PDF