• Title/Summary/Keyword: 2차 방사선

Search Result 892, Processing Time 0.038 seconds

AN EVALUATION ON THE INDICATIONS OF BIONATOR IN CLASS II DIVISION 1 MALOCCLUSION (II급 1류 부정교합 환자에서 Bionator의 적응증에 관한 연구)

  • Ahn, Sug-joon;Kim, Jong-Tae;Suhr, Cheong-hoon
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.45-54
    • /
    • 1997
  • The purpose of this study was to evaluate the indications of bionator in Class II division 1 malocclusion, The 48 subjects were classified into good result group(group1) and poor result group(group2) in reference to posttreatment molar relation, posttreatment overbite and overjet, posttreatment profile, and relapse. Pretreatment lateral cephalograms were calculated and evaluated by t-test stepwise discriminant analysis. The results were as follows ; 1. In jaw bone relationship, ANB, facial convexity angle, AB to facial plane angle were significantly different between two treatment groups. In denture pattern, L1 to facial plane, L1 to A-Pog, FMIA, and U1 to facial plane were significantly different and m soft tissue profile, protuberance of lower lip and upper lip were significantly different between tw o treatment groups. 2. The results in according to discriminant analysis stated that L1 to facial plane, ANB, FMIA and protuberance of lower lip help prediction of treatment result of bionator. 3. 3 major influential variables were obtained by stepwise discriminant analysis - L1 to facial plane, articular angle and ANB difference. And Fisher discriminant function was made by these three major variables.

  • PDF

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

The Effect of Chlorhexidine on Early Healing Stage of Guided Tissue Regeneration (조직유도재생술의 초기치유에 있어서 클로르헥시딘의 영향)

  • Lee, Jung-Yeon;Han, Soo-Boo;Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.4
    • /
    • pp.723-737
    • /
    • 1997
  • 본 연구의 목적은 조직유도재생술의 초기치유시에 구강양치액으로 사용되어지는 0.1% 클로르헥시딘과 0.2% 클로르헥시딘을 사용했을 경우, 양치액을 사용하지 않았을 경우의 세균감염 정도를 비교하는 것이다. 30명의 성인형 치주염에 이환되어진 사람을 대상으로 하였다. 초기치료(Scaling/Root planing/Oral hygiene instruction)를 시행한 후에 한 사람에 한 군데씩 선정하여 2급이나 3급의 치근이개부를 가지고 임상적으로 혹은 방사선학적으로 치간골내낭을 보이지 않는 치아에 통법에 따라 Gore-TexTM를 위치시켰다. 술후 5일간 항생제 (UnasynTM 375mg tablet p.o.tid)를 투여하고 차폐막을 제거할 때까지(4주 혹은 6주) 10명의 환자에게는 0.1% 클로르헥시딘을, 다른 10명의 환자에게는 0.2% 클로르헥시딘으로 구강양치를 하게 하고, 또 다른 10명의 환자에게는 구강양치액을 사용하지 않도록 하였다. 또 1주일에 한번씩 전문가구강위생술식을 실시하였다. 4주나 6주 후에 차폐막을 제거하고 주사전자현미경, 혐기성 세균배양을 이용하여 세균감염정도를 비교하였다. 1. 주사전자현미경으로 관찰시에 0.1% 클로르헥시딘을 사용했을 경우와 0.2% 클로르헥시딘을 사용했을 경우, 클로르헥시딘을 사용하지 않은 경우에 별 차이를 발견할 수 없었다. 2. 혐기성 세균배양시에 0.2% 클로르헥시딘을 사용했을 경우, 0.1%클로르헥시딘을 사용했을 경우보다 적은 수의 세균 수를 보였으나 통계적으로 유의할 만한 차이는 보이지 않았다. 클로르헥시딘을 사용하지 않은 경우에는 다른 두 경우에 비해 통계적으로 유의할 만한 차이를 보였다.(P<0.05) 3. Actinobacillus actinomycetemcomitans, Porphyromonas gingivalis, Prevotella intermedia를 인지한 경우에는 세 경우 모두 비슷한 비율로 발견되었다.

  • PDF

Consideration of the Effect according to Variation of Material and Respiration in Cone-Beam CT (Cone-Beam CT에서 물질 및 호흡 변화가 영상에 미치는 영향에 대한 고찰)

  • Na, Jun-Young;Kim, Jung-Mi;Kim, Dae-Sup;Kang, Tae-Young;Baek, Geum-Mun;Kwon, Gyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • Purpose: Image Guided Radiation Therapy (IGRT) has been carried out using On-Board Imager system (OBI) in Asan Medical Center. For this reason, This study was to analyze and evaluate the impact on Cone-Beam CT according to variation of material and respiration. Materials and Methods: This study was to acquire and analyze Cone-Beam CT three times for two material: Cylider acryl (lung equvalent material, diameter 3 cm), Fiducial Marker (using clinic) under Motion Phantom able to adjust respiration pattern randomly was varying period, amplitude and baseline vis-a-vis reference respiration pattern. Results: First, According to a kind of material, when being showed 100% in the acryl and 120% in the Fiducial Marker under the condition of same movement of the motion phantom. Second, According to the respiratory alteration, when being showed 1.13 in the baseline shift 1.8 mm and 1.27 in the baseline shift 3.3 mm for acryl. when being showed 1.01 in 1 sec of period and 1.045 in 2.5 sec of period for acryl. When being showed 0.86 in 0.7 times the standard of amplitude and 1.43 in 1.7 times the standard of amplitude for acryl. when being showed 1.18 in the baseline shift 1.8 mm and 1.34 in the baseline shift 3.3 mm for Fiducial Marker. when being showed 1.0 in 1 sec of period and 1.0 in 2.5 sec of period for Fiducial Marker. When being showed 0.99 in 0.7 times the standard of amplitude and 1.66 in 1.7 times the standard of amplitude for Fiducial Marker. Conclusion: The effect of image size of CBCT was 20% in the case of Fiducial marker. The impact of changes in breathing pattern was minimum 13% - maximum 43% for Arcyl, min. 18% - max. 66% for Fiducial marker. This difference makes serious uncertainty. So, Must be stabilized breathing of patient before acquiring CBCT. also must be monitored breathing of patient in the middle of acquire. If you observe considerable change of breathing when acquiring CBCT. After Image Guided, must be need to check treatment site using fluoroscopy. If a change is too big, re-acquiring CBCT.

  • PDF

A Comparison Study of Metaphase Analysis of Chromosomal Aberration and Flow Cytometric Assessment of Radiation-induced Apoptosis in Human Peripheral Lymphocytes (인체 말초혈액 림프구에서 방사선유도 염색체 손상 및 세포고사에 대한 중기염색체 분석 및 유세포계측 연구)

  • Bom, Hee-Seung;Lee, Seung-Yeon;Lee, Sang-Ku;Min, Jung-Jun;Jeong, Hwan-Jeong;Song, Ho-Cheon;Kim, Ji-Yeul;Shin, Jong-Hee;Suh, Sun-Pal;Rhang, Dong-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.94-99
    • /
    • 1999
  • Purpose: Radiation-induced chromosomal damage and apoptosis were compared in human lymphocytes. Materials and Methods: Peripheral lymphocytes from 10 normal volunteers (6 males, 4 females, age range $23{\sim}41$ years) were irradiated by gamma rays from a cell irradiator. Doses of irradiation were 0 (control), 0.18, 2, 5, 10, 20 and 25 Gy. Irradiated lymphocytes were examined by metaphase analysis for chromosomal aberrations and by flow cytometry for apoptosis. Results of both studies were compared according to dose. Results: Number of dicentric and ring chromosomes (D+R) was $0.5{\pm}0.53$ at baseline, which was significantly increased after radiation according to the dose. The fraction of cells showing annexin V-fluorescein isothiocyanate uptake was $0.51{\pm}$0.39%, which increased to $3.58{\pm}1.85%$ by 2 Gy irradiation, and then decreased. The fraction of cells showing propidium iodide (PI) uptake was $0.52{\pm}0.12%$, which significantly increased according to dose (upto $15.64{\pm}5.99%$ by 20 Gy irradiation). D+R and PI uptake were well correlated (r=0.84, p<0.001). Conclusion: Radiation-induced chromosomal aberration was correlated to nuclear uptake of PI, a marker of late apoptosis.

  • PDF

Treatment of Ossifying Fibroma (화골성 섬유종의 치료)

  • Jung, Sung-Taek;Chung, Jae-Yoon;Song, Eun-Kyoo;Park, Yong-Cheol
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.61-68
    • /
    • 2003
  • Purpose: We reviewed the outcome of treatment of ossifying fibroma involving long bones. Materials and methods: Eight patients who enrolled at our hospital for ossifying fibroma from 1994 to 1999 were selected for this study. Mean age was 7.9 years old. Five were male and three female. Seven involved tibia and one fibula. All cases were diagnosed by biopsy. The initial treatment was conservative and the followings were operative indications; (1) repeated fracture, (2) suddenly growing mass, (3) severe bowing deformity, (4) pseudoarthrosis. We assessed the recurrence by x-ray follow-up. Results: As initial treatment, curettage was performed in 2 patients, observation in 2 subperiosteal resection in one and extraperiosteal resection in 3 patients. Two patients who were observed and 3 patients who received extraperiosteal resection did not suffer recurrence. Two patients who received curettage and one patient who received subperiosteal resection had recurrence. The second treatment was performed in 3 patients. The one case of curettage received extraperiosteal resection. The other was in observation. The case of subperiosteal resection was in observation, too. There were no recurrence and aggravation at follow-up. Conclusion: Ossiying fibroma should to be treated by conservative method. If operation is indicated, extraperiosteal resection could reduce the recurrence.

  • PDF

STUDY ON THE GROWTH OF THE MANDIBLE USING WIDE OPEN LATERAL CEPHALOGRAM (Wide open lateral cephalogram을 이용한 하악골 성장에 관한 연구)

  • Moon, Sung-Uk;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.39-50
    • /
    • 2001
  • In proceeding with orthodontic treatment, the prediction for the shape, growth rate and growth direction of mandible plays a major role to set up the treatment plan and determine its period and prognosis. Various approaches being made so far have shown that the linear and angular measurement using lateral cephalograms are relatively accurate to estimate them. This study was purposed to find the shape of mandible more clearly by preventing the overlap of the Condyle head area which appears in lateral cephalogram, and to estimate its growth rate by comparing the growth quantity and ratio via lateral area measurement. This experimental was performed against 40 patients total, of which Class I of 14, Class II of 9 and Class III of 17 consist. Wide open lateral cephalograms of 40 patients were taken over average period of 4 Year 3 Months, then the linear and angular measurements were carried out with 11 itemized lists. Autocad Rl4 application program was utilized to draw their appearance, measure and compare their lateral area. As a result of study, conclusions were made as follows; 1. Mandibular body length (gonion-menton) tended to increase in order of CIII, CI and CII, and Mandibular body length of CIII group had a tendency to grow twice faster than that of CII group. 2. In lateral items such as Go-Me, A-Cd, B-Cp, E-F and G-H, CIII showed a significant increase on the year-average quantity and rate of the growth, and especially apparent difference was observed in CIII group rather than CII group. 3. For the 4 Year 3 Months period, the year-average growth quantity of lateral area of the mandible was $1.0cm^2$ for Class I, $0.8cm^2$ for Class II and $1.4cm^2$ for Class III, which corresponds to $11.9\%,\;11.8\%\;and\;20.3\%$ of growth ratio respectively. Thus, growth ratio almost 2 times more than other groups was observed in group CIII while growth ratio between group CI and CII has little difference. 4. Considering the results as above, it can be proposed that the difference in size of the mandible between groups is caused by the difference in the growth rate and growth quantity of the mandible, which generated in the middle of growth, rather than the difference in size of congenital Jaw-bone.

  • PDF

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF

Quasi-breath-hold (QBH) Biofeedback in Gated 3D Thoracic MRI: Feasibility Study (게이트 흉부자기 공명 영상법과 함께 사용할 수 있는 의사호흡정지(QBH) 바이오 피드백)

  • Kim, Taeho;Pooley, Robert;Lee, Danny;Keall, Paul;Lee, Rena;Kim, Siyong
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.72-78
    • /
    • 2014
  • The aim of the study is to test a hypothesis that quasi-breath-hold (QBH) biofeedback improves the residual respiratory motion management in gated 3D thoracic MR imaging, reducing respiratory motion artifacts with insignificant acquisition time alteration. To test the hypothesis five healthy human subjects underwent two gated MR imaging studies based on a T2 weighted SPACE MR pulse sequence using a respiratory navigator of a 3T Siemens MRI: one under free breathing and the other under QBH biofeedback breathing. The QBH biofeedback system utilized the external marker position on the abdomen obtained with an RPM system (Real-time Position Management, Varian) to audio-visually guide a human subject for 2s breath-hold at 90% exhalation position in each respiratory cycle. The improvement in the upper liver breath-hold motion reproducibility within the gating window using the QBH biofeedback system has been assessed for a group of volunteers. We assessed the residual respiratory motion management within the gating window and respiratory motion artifacts in 3D thoracic MRI both with/without QBH biofeedback. In addition, the RMSE (root mean square error) of abdominal displacement has been investigated. The QBH biofeedback reduced the residual upper liver motion within the gating window during MR acquisitions (~6 minutes) compared to that for free breathing, resulting in the reduction of respiratory motion artifacts in lung and liver of gated 3D thoracic MR images. The abdominal motion reduction in the gated window was consistent with the residual motion reduction of the diaphragm with QBH biofeedback. Consequently, average RMSE (root mean square error) of abdominal displacement obtained from the RPM has been also reduced from 2.0 mm of free breathing to 0.7 mm of QBH biofeedback breathing over the entire cycle (67% reduction, p-value=0.02) and from 1.7 mm of free breathing to 0.7 mm of QBH biofeedback breathing in the gated window (58% reduction, p-value=0.14). The average baseline drift obtained using a linear fit was reduced from 5.5 mm/min with free breathing to 0.6 mm/min (89% reduction, p-value=0.017) with QBH biofeedback. The study demonstrated that the QBH biofeedback improved the upper liver breath-hold motion reproducibility during the gated 3D thoracic MR imaging. This system can provide clinically applicable motion management of the internal anatomy for gated medical imaging as well as gated radiotherapy.

An Experimental Study on the Effects of X-ray Irradiation and Hyperthermia on the Rat Testis (X-선 조사와 온열요법이 백서고환에 미치는 영향에 관한 실험적 연구)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.17-27
    • /
    • 1990
  • The effects of both hyperthermia alone and X-ray irradiation combined with hyperthermia on rat testis have been investigated. The histological changes were observed on 15 and 30 days after treatment. There was no histological change of rat testis by hyperthermia alone. The earliest change by X-ray irradiation was the degeneration of the spermatogonia of the seminiferous tubule, which was appeared in 2 Gy group. Necrosis of the spermatogonia was severe in 6 Gy group and complete atrophy was developed in 8 Gy group. With increased dose of radiation, the degree of changes of tubules was increased. In combined group of X-ray irradiation and hyperthermia, the histological change of the seminiferous tubule was more severe than X-ray alone group. Necrosis and atrophy of the spermatogonia were appeared in 2 Gy and complete atrophy of spermatogonia was seen in 6 Gy group. Thermal enhancement ratio (calculated at the complete atrophy of the spermatogonia) was 1.3 in this experiment. There was no difference in observation time inverval between 15 and 30 days after each treatment in all groups.

  • PDF