• Title/Summary/Keyword: 2차 거칠기

Search Result 32, Processing Time 0.022 seconds

Comparison of removal torque of dual-acid etched and single-acid etched implants in rabbit tibias (단일, 이중 산처리 임플란트의 회전제거력 비교)

  • Kim, Jong-Jin;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.335-341
    • /
    • 2019
  • Purpose: Chemically strong-acids (HF and $HCl/H_2SO_4$) dual etching implant surfaces have higher strengths of osseointegration than machined implant surfaces. However, the dual acid treatment deteriorates the physical properties of the titanium by weakening the fatigue resistance of the implant and causing microcracks. The removal torque comparison between the dual-acid etched (hydrochloric acid, sulfuric acid, HS) and single-acid etched implants (hydrochloric acid, H) could reveal the efficiency of implant surface acid treatment. Materials and methods: Nine $3.75{\times}4mm$ dual-acid etched SLA implants and nine single-acid etched SLA implants were inserted into New Zealand rabbit tibias. After 10 days, removal torque, roughness, and wetting angle were measured. Results: Mean removal torque values were as follows: Mean removal torque were 9.94 Ncm for HS group and 9.96 Ncm for H group (P=.995). Mean surface roughness value were $0.93{\mu}m$ for HS group and $0.84{\mu}m$ for H group (P=.170). Root mean square roughness (RSq) values were $1.21{\mu}m$ for HS group and $1.08{\mu}m$ for H group (P=.294), and mean wetting angle values were $99^{\circ}$ for HS group and $98^{\circ}$ for H group (P=.829). Statistical analysis showed no significant difference between the removal torques, roughness, or wetting angles of the two groups. Conclusion: In this experiment, we found no significant difference in removal torque, roughness, or wetting angle between dual-acid etched and single-acid etched implants.

Characteristics of Machined Surface Roughness and Surface Layers of WC-Co Tools with Plasma Source Ion Implantation (WC-Co 공구의 이온 주입에 따른 표면층 및 가공된 표면거칠기 특성)

  • Kang, Seong-Ki;Kim, Yung-Kyu;Wang, Duck-Hyun;Chun, Young-Rok;Kim, Won-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.106-113
    • /
    • 2010
  • The most suitable condition for plasma source ion implantation(PSII) was found based on the study of the characteristics of PSIIed tool and machined surfaces. The depth analysis according to the chemical bonding state of elements and surface component elements through the XPS and SIMS, was conducted to find the improved property of the PSIIed surface. Due to the diffusion of PSII, the nitrogen was found up to a depth of about 150nm according to the supplied voltage and ion implanted time. The deep diffusion by nitrogen caused the surface modification, but the formation of oxide component was found due to the residual gas contamination on the surface. Statistical method of ANOVA was conducted to find the effects of spindle speed and feed rate in interaction for machined surface roughness with PSIIed tools. The surface modification was found largely occurred by the nitrogen implanted surface with 2 hours for 27kV, 35kV and 43kV.

Simultaneous Measurements of Local Phase and Reflectivity Variation of a Surface Using Multiport Homodyne Interferometer (다출력단 호모다인 간섭계를 이용한 위상 및 반사율 분포의 동시 측정)

  • 정희성;김종회;조규만
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.60-61
    • /
    • 2000
  • 표면 형상을 측정하는 방법은 샘플표면의 평평도, 곡률, 거칠기, 깊이 측정등의 수많은 상업적 응용을 위해 광범위하게 개발되어왔다. 이중에서도 특히 간섭현상을 이용한 광 표면 프로파일러는 표면의 3차원 구조를 측정하는데 있어서 subangstrom의 매우 높은 깊이 분해능을 가지므로 샘플 표면의 정밀 진단에 많이 사용되어 왔다. [1,2] 광 간섭 현미경은 기본적으로 광위상 변화를 검출하여 그것을 표면구조변화로 바꾸어주는 역할을 한다. 그러나 광위상 변화는 샘플 표면의 구조뿐만 아니라 물질 변화와 박막두께 변화에도 민감하므로 순수한 표면구조측정은 샘플이 단일물질인 경우에만 달성된다는 문제점이 있다. 따라서 이러한 광위상 측정과 관련된 ambiguity를 해결하기 위해서는 일반적인 광 간섭 현미경에서 얻어지는 위상데이터와 더불어 물질변화를 분석할 수 있는 다른 추가적인 데이터가 필요하다. 이러한 필요성 때문에 우리는 광위상 뿐만 아니라 반사율 분포도 동시에 측정할 수 있는 새로운 방식의 다출력단 호모다인 간섭계(Homodyne I/Q Interferometer; HIQI)를 구성하였으며[3], 그 실험장치도는 [Fig. 1]과 같다. HIQI는 in-phase and quadrature 검출방식에 기반을 두며, 이 검출방식은 PBS에서 반사되는 빛살과 투과되는 빛살 사이의 위상차가 $\pi$/4라는 실험결과로부터 달성된다. HIQI는 샘플 표면의 3차원 구조 뿐만 아니라 광학적 특성의 2차원 분포도 동시에 얻을 수 있다. (중략)

  • PDF

Investigation of Rock Slope Failures based on Physical Model Study (모형실험을 통한 암반사면의 파괴거동에 대한 연구)

  • Cho, Tae-Chin;Suk, Jae-Uk;Lee, Sung-Am;Um, Jeong-Gi
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.447-457
    • /
    • 2008
  • Laboratory tests for single plane sliding were conducted using the model rock slope to investigate the cut slope deformability and failure mechanism due to combined effect of engineering characteristics such as angle of sliding plane, water force, joint roughness and infillings. Also the possibility of prediction of slope failure through displacement monitoring was explored. The joint roughness was prepared in forms of saw-tooth type having different roughness specifications. The infillings was maintained between upper and lower roughness plane from zero to 1.2 times of the amplitude of the surface projections. Water force was expressed as the percent filling of tension crack from dry (0%) to full (100%), and constantly increased from 0% at the rate of 0.5%/min and 1%/min upto failure. Total of 50 tests were performed at sliding angles of $30^{\circ}$ and $35^{\circ}$ based on different combinations of joint roughness, infilling thickness and water force increment conditions. For smooth sliding plane, it was found that the linear type of deformability exhibited irrespective of the infilling thickness and water force conditions. For sliding planes having roughness, stepping or exponential types of deformability were predominant under condition that the infilling thickness is lower or higher than asperity height, respectively. These arise from the fact that, once the infilling thickness exceeds asperities, strength and deformability of the sliding plane is controlled by the engineering characteristics of the infilling materials. The results obtained in this study clearly show that the water force at failure was found to increase with increasing joint roughness, and to decrease with increasing filling thickness. It seems possible to estimate failure time using the inverse velocity method for sliding plane having exponential type of deformability. However, it is necessary to estimate failure time by trial and error basis to predict failure of the slope accurately.

표준기용 Spectroscopic Ellipsometer 제작

  • 조용재;조현모;김현종;신동주;이윤우;이인원
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.38-39
    • /
    • 2002
  • Spectroscopic ellipsometer(SE)는 박막의 두께, 굴절률, 흡수율, 에너지 갭, 결정상태, 밀도, 표면 및 계면의 거칠기 등에 관한 유용한 정보들을 제공한다. (1-3) SE는 빛을 탐침으로 사용하기 때문에 비파괴적이고 비접촉식 박막물성 측정방법이며 편광변화에 대한 상대적 물리량을 측정함으로써 정밀도와 재연성이 매우 높은 장점들을 갖고 있다. 따라서 SE는 반도체 메모리 소자, 평판 디스플레이, DVD와 CD와 같은 데이터 저장장치 등을 제작하는 공정에서 박막에 관련된 공정계측장비로 사용되고 있다. 특히, 최근의 차세대 반도체 소자 개발에 관한 연구 등(4-6)에서는 수 nm 두께의 다양한 초박막들에 관한 물성연구가 주관심사이기 때문에 최고의 성능을 갖는 계측장비와 기술이 요구되고 있다. 따라서 본 연구에서는 그림과 같은 편광자(polarizer)-시료(sample)-검광자(analyzer)로 구성된 PSA구조의 표준기용 rotating-analyzer SE를 제작하게 되었다. 현재까지 개발된 ellipsometer의 수많은 종류들 중에서 null 형, rotating element 형, 그리고 phase modulation 형이 가장 많이 사용되고 있다. 여기서 element란 polarizer, analyzer, 또는 compensator와 같은 광 부품들을 지칭하는데 이 중 하나 또는 둘을 회전시키기 때문에 그 종류 또한 매우 많다. 이들 중에서 회전검광자형 ellipsometer는 입사각 정렬이 우수하고, 파장에 무관한 편광기만 사용하므로 비교적 넓은 광량자 에너지영역에서 정확도 높은 데이터를 얻을 수 있기 때문에 박막 상수의 정밀측정에 가장 적합하다. 특히, 본 연구에서 제작된 ellipsometer에는 간섭계 장치, polarizer tracking,(2) zone average,(1) 그리고 low-pass filter 등을 사용함으로써 측정오차를 최대한 줄이는 노력을 하였다.

  • PDF

A Numerical Analysis on the Shear and Hydraulic behavior of Single Rock Joint with Roughness (거칠기를 고려한 단일 절리의 전단, 수리적 거동에 대한 수치해석)

  • 이희석;이연규
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2000.09a
    • /
    • pp.117-128
    • /
    • 2000
  • The development of proper joint model, which can describe real phenomena exactly and still can be used easily, is one of the most important element for the analysis of the mechanical and hydraulic behavior of discontinuous rock mass. In this study, an elasto-plastic constitutive model of joint behavior considering asperity degradation was extended with the concept of first and second order asperities. The proposed model was implemented to numerical code with discrete finite joint element. The parametric study with the various asperity angles and degradation coefficients showed that the model can reproduce the shear behavior of typical rough joints well. Results of laboratory monotonic and cyclic shear tests were compared with those of numerical tests to validate the model. The hydraulic model considering the relations between gouge production and aperture was introduced to the mechanical model. In an attempt to examine the performance of the model, comparative numerical test was conducted. Permeability between joint surfaces increased rapidly at the first stage, but became nearly constant with increasing shear displacement due to gouge production and uniform variation of aperture distribution.

  • PDF

A Numerical Analysis on the Shear and Hydraulic behavior of Single Rock Joint with Roughness (거칠기를 고려한 단일 절리의 전단, 수리적 거동에 대한 수치해석)

  • 이희석;이연규
    • Tunnel and Underground Space
    • /
    • v.10 no.3
    • /
    • pp.366-377
    • /
    • 2000
  • The development of proper joint model, which can describe real phenomena exactly and still can be used easily, is one of the most important element for the analysis of the mechanical and hydraulic behavior of discontinuous rock mass. In this study, an elasto-plastic constitutive model of joint behavior considering asperity degradation was extended with the concept of first and second order asperities. The proposed model was implemented to numerical code with discrete finite joint element. The parametric study with the various asperity angles and degradation coefficients showed that the model can reproduce the shear behavior of typical rough joints well. Results of laboratory monotonic and cyclic shear tests were compared with those of numerical tests to validate the model. The hydraulic model considering the relations between gouge production and aperture was introduced to the mechanical mode1. In an attempt to examine the performance of the model, comparative numerical test was conducted. Permeability between joint surfaces increased rapidly at the first stage, but became nearly constant with increasing shear displacement due to gouge production and uniform variation of aperture distribution.

  • PDF

SURFACE ROUGHNESS OF ESTHETIC RESTORATIVE MATERIALS BY POLISHING SYSTEMS (연마기구에 따른 심미 치아 수복재료의 표면 거칠기에 관한 비교 연구)

  • Park, Eun-Hae;Yang, Ku-Ho;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.520-529
    • /
    • 2003
  • Proper finishing and polishing of tooth restorations enhance the esthetics and the longevity of the restored tooth. The aims of this study were to identify an appropriate polishing system for each esthetic restorative material(Z250, Heliomolar, Dyract AP, Fuji II LC), and to compare the efficiency of polishing systems(Enhance, Sof-Lex, Composite). The control group remains untouched. The results were as follows: 1. There was no significant difference of surface roughness among the materials, while a roughness value of Z250 was the lowest of all. 2. The smoothest surface was produced by Mylar sheet on all materials. The polishing procedures, however, increased a roughness value. 3. The smoothest surfaces were produced by Sof-Lex, and there was significant difference of surface roughness between Sof-Lex and Enhance systems. 4. The smoother surfaces on the control group showed many scratches after the polishing procedures in the SEM findings.

  • PDF

Frequency Dependence of High-frequency Bottom Reflection Loss Measurements (고주파 해저면 반사손실의 주파수 종속성 측정)

  • 박순식;윤관섭;최지웅;나정열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.8
    • /
    • pp.652-659
    • /
    • 2003
  • High-frequency(40∼120 kHz) reflection loss measurements on the water-sandy sediment with a flat interface were conducted in a water tank for various grazing angles. The water tank(5×5×5 m) was filled with a 0.5 m-thick-flat bottom of 0.5ø-mean-grain-size sand. Reflection losses, which were experimentally obtained as a function of grazing angle and frequency, were compared with the forward loss model, APL-UW model (Mourad & Jackson, 1989). For frequencies below 60 kHz, the observed losses well agree with the reflection loss model, however, in cases for frequencies above 70 kHz, the observed losses are greater by 2∼3 dB than the model results. The model calculation, which does not fully account for the vertical scale of roughness due to grain size, produce less bottom losses compared to the observations that correspond to large roughness based on the Rayleigh parameter in the wave scattering theory. In conclusion, for the same grain-size-sediment, as frequencies increase, the grainsize becomes the scale of roughness that could be very large for the frequencies above 70 kHz. Therefore, although the sea bottom was flat, we have to consider the frequency dependence of an effect of roughness within confidential interval of grain size distribution in reflection loss model.

Comparison of Marginal Fitness of Zirconia Copings According to Impression Techniques and Zirconia Blocks (구강인기방법과 블록 종류에 따른 지르코니아 코핑의 변연적합도 비교)

  • Chung, In-Sung;Jeon, Byung-Wook;Kim, Won-Young
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.151-157
    • /
    • 2016
  • The purpose of this study was to compare of marginal fitness of zirconia copings according to impression techniques and zirconia blocks. For the conventional impression, two types of rubber impression materials were used and digital impression was made by using an intraoral scanner. Zirconia copings were manufactured from three types of blocks. With each of ten zirconia copings was determined by surface roughness and marginal fitness. For surface roughness, LUXEN Smile($2.3{\pm}0.9{\mu}m$) block was superior. And the lowest mean values and standard deviations of marginal gap for the HL specimens were $26.5{\pm}2.1{\mu}m$ for buccal, $27.2{\pm}2.1{\mu}m$ for lingual, and that of the HJ specimens $29.6{\pm}4.0{\mu}m$ for mesial, $29.0{\pm}3.0{\mu}m$ for distal. One-way ANOVA showed statistically significant difference between groups for marginal fitness(p<0.05). From the above results, the impression techniques and zirconia blocks had influence on marginal fit of the zirconia copings. Also the marginal fitness of all groups showed clinically acceptable range.