• Title/Summary/Keyword: 2차전지

Search Result 572, Processing Time 0.03 seconds

Estimation of Specific Leaf Area Index Using Direct Method by Leaf Litter in Gwangneung, Mt. Taewha and Mt. Gariwang (광릉숲, 태화산, 가리왕산 활엽수림에서 낙엽에 의한 수종별 엽면적지수 추정)

  • Kwon, Boram;Jeon, Jihyeon;Kim, Hyun Seok;Yi, Myong Jong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.1
    • /
    • pp.1-15
    • /
    • 2016
  • Annual litterfall production and leaf area index (LAI, $m^2/m^2$) were estimated using litter traps in Gwangneung, Mt. Taewha and Mt. Gariwang. Annual total litter fall production including branch, bark, others was the highest in Gwangneung($7497.3{\pm}326.5kg/ha/yr$), which had the highest basal area at late successional stage, and followed by Mt. Taewha($5929.1{\pm}225.8kg/ha/yr$) and Mt. Gariwang($3,210.1{\pm}220.1kg/ha/yr$). Mt. Gariwang had the lowest litterfall production due to high elevation and short growing season even with the higher stand density and basal area than Mt. Taewha. Similarly, LAI, which was calculated by multiplying the mass of leaf litter with specific leaf area, was the highest in Gwangneung($5.99{\pm}0.69$) and followed by Mt. Taewha($5.20{\pm}0.24$) and Mt. Gariwang($4.06{\pm}0.42$) and the upper canopy species had the highest leaf area index in every sites (Gwangneung : 4.72, Mt. Taewha : 3.08, Mt. Gariwang : 2.19). However, species specific LAI estimation based on the relationship between basal area and leaf area was limited due to upper canopy species non-proportionality of basal area with LAI. In addition, the comparison between direct and indirect LAI measurement showed the importance of canopy clumping, especially at high density. Our study emphasized the necessity of direct LAI measurement using litter fall traps especially at temperate deciduous forest with diverse species.

Analysis of Stability Indexes for Lightning by Using Upper Air Observation Data over South Korea (남한에서 낙뢰발생시 근접 고층기상관측 자료를 이용한 안정도 지수 분석)

  • Eom, Hyo-Sik;Suh, Myoung-Seok
    • Atmosphere
    • /
    • v.20 no.4
    • /
    • pp.467-482
    • /
    • 2010
  • In this study, characteristics of various stability indexes (SI) and environmental parameters (EP) for the lightning are analysed by using 5 upper air observatories (Osan, Gwangju, Jeju, Pohang, and Baengnyeongdo) for the years 2002-2006 over South Korea. The analysed SI and EP are the lifted index, K-index, Showalter stability index, total precipitable water, mixing ratio, wind shear and temperature of lifting condensation level. The lightning data occurred on the range of -2 hr~+1 hr and within 100 km based on the launch time of rawinsonde and observing location are selected. In general, summer averaged temperature and mixing ratio of lower troposphere for the lightning cases are higher about 1 K and $1{\sim}2gkg^{-1}$ than no lightning cases, respectively. The Box-Whisker plot shows that the range of various SI and EP values for lightning and no lightning cases are well separated but overlapping of SI and EP values between lightning and no lightning are not a little. The optimized threshold values for the detection of lightning are determined objectively based on the highest Heidke skill socre (HSS), which is the most favorable validation parameter for the rare event, such as lightning, by using the simulation of SI and EP threshold values. Although the HSS is not high (0.15~0.30) and the number and values of selected SI and EP are dependent on geographic location, the new threshold values can be used as a supplementary tool for the detection or forecast of lightning over South Korea.

The Economic Effects of the New and Renewable Energies Sector (신재생에너지 부문의 경제적 파급효과 분석)

  • Lim, Seul-Ye;Park, So-Yeon;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.31-40
    • /
    • 2014
  • The Korean government made the 2nd Energy Basic Plan to achieve 11% of new and renewable energies distribution rate until 2035 as a response to cope with international discussion about greenhouse gas emission reduction. Renewable energies include solar thermal, photovoltaic, bioenergy, wind power, small hydropower, geothermal energy, ocean energy, and waste energy. New energies contain fuel cells, coal gasification and liquefaction, and hydrogen. As public and private investment to enhance the distribution of new and renewable energies, it is necessary to clarify the economic effects of the new and renewable energies sector. To the end, this study attempts to apply an input-output analysis and analyze the economic effects of new and renewable energies sector using 2012 input-output table. Three topics are dealt with. First, production-inducing effect, value-added creation effect, and employment-inducing effect are quantified based on demand-driven model. Second, supply shortage effects are analyzed employing supply-driven model. Lastly, price pervasive effects are investigated applying Leontief price model. The results of this analysis are as follows. First, one won of production or investment in new and renewable energies sector induces 2.1776 won of production and 0.7080 won of value-added. Moreover, the employment-inducing effect of one billion won of production or investment in new and renewable energies sector is estimated to be 9.0337 persons. Second, production shortage cost from one won of supply failure in new and renewable energies sector is calculated to be 1.6314 won, which is not small. Third, the impact of the 10% increase in new and renewable energies rate on the general price level is computed to be 0.0123%, which is small. This information can be utilized in forecasting the economic effects of new and renewable energies sector.

CNT-Ni-Fabric Flexible Substrate with High Mechanical and Electrical Properties for Next-generation Wearable Devices (차세대 웨어러블 디바이스를 위한 높은 기계적/전기적 특성을 갖는 CNT-Ni-Fabric 유연기판)

  • Kim, Hyung Gu;Rho, Ho Kyun;Cha, Anna;Lee, Min Jung;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.2
    • /
    • pp.39-44
    • /
    • 2020
  • Recently, numerous researches are being conducted in flexible substrate to apply to wearable devices. Particularly, Conductive substrate researches that can implement the wearable devices on clothing are massive. In this study, we formed fiber substrate spraying CNT and Pd mixed solution on it and plated metal layer with electroless plating. Used SEM equipment and EDS analysis to analysis structure of the plated fiber substrate and discovered Ni layer was created. For check electrical properties, mapping was performed to check surface resistance and distribution of resistance of electroless plated fiber substrate with 4-point probe. It was confirmed that conductivity was improved as the duration of electroless plating was increased, and it was found that distribution of resistance by surface location was uniform. Changes in resistance due to mechanical stress were measured through tensile, bending, and twisting tests. As a result, it was confirmed that resistance change of flexible substrate gradually disappeared as plating time increased. Using UTM (Universal testing machine), it was analyzed mechanical properties of the electroless plated substrate with respect to changes in plating time were improved. In the case of conductive fiber substrate in which electroless plating was performed for 2 hours, tensile strength was increased by 16 MPa than fiber substrate. Based on these results, we found that Ni-CNT-Fabric flexible substrate is adequate for clothing-intergrated conductive substrate and we positively expect that this experiment shows flexible substrate can adapt to and develop not only a wearable device technology but also other fields needing flexibility such as battery, catalyst and solar cell.

Plasma Transforming Growth Factor-$\beta$1 Levels of Cancer Patients (암 환자의 혈장 Transforming Growth Factor-$\beta$1 농도)

  • 전지현;이시은;이수진;박찬후;장정순;하우송;박순태;박병규
    • Biomedical Science Letters
    • /
    • v.5 no.2
    • /
    • pp.181-190
    • /
    • 1999
  • To evaluate the usefulness of transforming growth factor-$\beta$1 (TGF-$\beta$1) as a new tumor marker, we determined the plasma TGF-$\beta$1 levels using sandwich ELISA assay in cancer patients. Patients with three most common adult cancers in Korea (stomach, liver and breast cancer) and children's cancers (leukemia and two kinds of solid tumor) were enrolled for the study. Furthermore, 39 individuals were subjected to age and sex-stratified plasma TGF-$\beta$1 analysis. No statistical difference was demonstrated with respect to age or sex. The mean plasma TGF-$\beta$1 level (16.0 ng/ ml) of stomach cancer patients was significantly higher than that (8.3 ng/ml) of controls. However, there was no difference among the mean plasma TGF-$\beta$1 levels of liver, breast cancer patients and controls. Seven of 16 patients (43.7%) with stomach cancer, one of 8 (12.5%) with liver cancer, and one of 7 (14.3%) with breast cancer showed higher TGF-$\beta$1 levels compared to controls. Plasma TGF-$\beta$1 concentrations of five leukemic children remained in the normal range regardless of the remission state. In contrast, initial high TGF-$\beta$1 levels from two children with solid tumors returned to normal range on surgical resection of tumors. From the above results, we could conclude that plasma TGF-$\beta$1 levels of apparently healthy individuals seem to be rather constant irrespective of difference in age or sex, and the plasma TGF-$\beta$1 has the limited value as a screening test for the diagnosis of aforementioned adult cancers because of its low sensitivity. Finally, additional studies need to be pursed for the large number of stomach cancer and pediatric solid tumor patients in order to reach a secure conclusion on the usefulness of plasma TGF-$\beta$1 as a tumor marker in these patients.

  • PDF

Antibiotic Sensitivity Test of Streptococcus pyogenes Obtained in Patients with Streptococcal Infections, 2000 (2000년 A군 연쇄구균 감염자로부터 분리된 균주의 항균제 감수성 검사)

  • Kim, Yeon-Ho;Cha, Sung-Ho;Ma, Sang-Hyuk;Kim, Ki-Sang;Lee, Young-Hee
    • Pediatric Infection and Vaccine
    • /
    • v.9 no.1
    • /
    • pp.79-84
    • /
    • 2002
  • Purpose : About 41% of obtained group A streptococci in the 1998 was reported as erythromycin-resistant streptococci in Seoul, Korea. The most common T serotype was T12, followed by T4 and T28. We'd like to monitor the serological changes and antibiotic sensitivity test of Streptococcus pyogenes obtained from the patients with pharyngotonsillitis and invasive diseases from 1999 through 2001. Also, it could be proposed to choose the proper antibiotic selection in the area where the rate of erythromycin-resistant streptococci is high. Methods : From Jan. 1999 to Oct. 2001, 208 isolates of group A streptococci were collected from inpatients and outpatients with pharyngotonsillitis, scarlet fever, and invasive infections in Seoul and Southern part of peninsula. All isolates were serotyped by T-agglutination, minimum inhibitory concentrations(MICs) which were determined by agar dilution methods, according to the guidelines of the National Committee for Clinical Laboratory Standards (NCCLS). Results : The most common T serotype was T12(29.8%), followed by T1(23.1%), T4 (14.9%). T1 was prominent serotype compared with previous year. T serotyping, among 25 isolates obtained from the patients with scarlet fever in Southern part of peninsula mostly, was T12, T1, and T4 in order of frequency. All the isolates tested were susceptible to penicillin, cefprozil, vancomycin, ceftriaxone, and chloramphenicol. However, 23 isolates(14.2%) was resistant to erythromycin and 18 isolates(11.1%) was resistant to clarithromycin. Serotype T12 was found to be the most resistant serotype to erythromycin and/or clarithromycin. Conclusion : High rate of erythromycin-resistant streptococci which surveyed in 1998 were reduced to 14.2% in this study. We should have to further evaluate the reason of decreased resistant strains and consider the resistant strains of streptococci in choosing the antibiotics. There was no serological characteristics according to the types of disease entities. Between the serologic distributions in Seoul and the Southern part of peninsula area are same, we could presume that the serological typing of strains obtained over the country may be not different.

  • PDF

Preparation of Polymer Gel Electrolyte for EDLCs using P(VdF-co-HFP)/PVP (P(VdF-co-HFP)/PVP를 이용한 EDLC용 고분자 겔 전해질의 제조)

  • Jung, Hyun-Chul;Jang, In-Young;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.17 no.3
    • /
    • pp.243-249
    • /
    • 2006
  • Porous polymer gel electrolytes (PGEs) based on poly(vinylidenefluoride-co-hexafluoropropylene) (P(VdF-co-HFP)) as a polymer matrix and polyvinylpyrolidone (PVP) as a pore-forming agent were prepared and electrochemical properties were investigated for an electric double layer capacitor (EDLC) in order to increase a permeability of an electrolyte into the PGE. Propylene carbonate (PC) and ethylene carbonate (EC) as plasticizers, and tetraethylammonium tetrafluoroborate ($TEABF_4$) as a supporting salt for the PGE were used. EDLC unit cells were assembled with the PGE and electrode comprising BP-20 and MSP-20 as activated carbon powders, Super P as a conducting agent, and P(VdF-co-HFP)/PVP as a mixed binder. Ion conductivity of PGEs increased with an increased PVP content and was the best at 7 wt% PVP, whereas electrochemical characteristics such as AC-ESR of unit cell were better in 3 wt%. And electrochemical characteristics of the unit cell with PGE were the best at a 33 : 33 weight ratio of PC to EC. Specific capacitance of a mixed plasticizer system of PE and EC was higher than that of pure PC. Ion conductivity of PGEs with a film thickness of $20{\mu}m$ was higher, but electrochemical characteristics of unit cells were higher for a $50{\mu}m$ membrane thickness. Also, the unit cell has shown the highest capacitance of 31.41 F/g and more stable electrochemical performance when PGE and electrode were hot pressed. Consequently, the optimum composition ratio of PGE for EDLCs was 23 : 66 : 11 wt% such as P(VdF-co-HFP) : PVP = 20 : 3 wt% and PC : EC = 44 : 22 wt%. In this case, $3.17{\times}10^{-3}S/cm$ of ion conductivity was achieved at the $50{\mu}m$ thickness of PGE for EDLCs. And the electrochemical characteristics of unit cells were $2.69{\Omega}$ of DC-ESR, 28 F/g of specific capacitance, and 100% of coulombic efficiency.

Aeromagnetic Characteristics of the Samryangjin Caldera Area (삼량진 칼데라 지역의 항공자력특성 연구)

  • Koo Sung-Bon;Lee Tai-Sup;Park Yeong-Sue
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.2
    • /
    • pp.101-109
    • /
    • 1998
  • Using airborne magnetic data, magnetic characteristics were studied at the Samryangjin caldera area developed in the volcanics of the Yuchon sub-basin, the south eastern part of the Gyeongsang basin. Residual magnetics, reduction to the pole, horizontal derivative, and vertical derivative maps are prepared. Using these maps, the magnetic lithofaces are zoned and the geological structures such as caldera and faults were qualitatively interpreted. In addition, the two quantitative interpretations were performed. Firstly, the forward modelling were done to the 14.5 line km crossing the caldera area to the northeast-southwest direction. Applying the 3-D Euler deconvolution method to the whole study area, the depth extent and the characteristics of the magnetic anomalous bodies were studied. According to the results, the magnetic lithofaces of the area are zoned by 4 units. In general, these are well matched with the geological distributions. But the biotite granites intruded in the northern boundary of the Samryangjin caldera show the high magnetic intensity, while the biotite granites of the other areas show the low magnetic intensity and the different magnetic lithofaces. Thus, we interpreted that the biotite granites are closely related with the volcanic activity of the Samryngjin caldera, and are intruded in the fracture zones developed along the caldera rim. The Samryangjin caldera and fault structures of the area can be easily recognized by the distinct magnetic structures from the various magnetic anomaly maps. Also the topographic characteristics well reflect these structures. The results of the forward modelling show that the magnetic basement depth of the Gyeongsang sedimentary basin is on the average about 6 km and in maximum 10 km. And the depth becomes shallower toward the caldera boundary due to the shallow intrusion of the volcanics. The results of the 3-D Euler method also show the caldera and fault structures. And the relatively shallow magnetic anomalous bodies which are related with the volcanics are generally developed to the east-west and northeast directions, while the deep magnetic anomalous bodies to the northwest direction.

  • PDF

Antioxidative Effects of Inula britannica var. chinensis Flower Extracts According to the flowering period and species of Inula britannica var. chinensis (금불초 종(種) 및 개화시기에 따른 금불초 꽃 추출물의 항산화 효능)

  • Kwon, Soon Sik;Jeon, So Ha;Jeon, Ji Min;Cheon, Jong Woo;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.3
    • /
    • pp.195-203
    • /
    • 2013
  • In this study, antioxidative effects of the extracts of different species and flowering periods of Inula britannica were investigated. According to the free radical (1,1-diphenyl-2-picrylhydrazyl, DPPH) scavenging activity of the extracts, The I. britannica var. chinensis flower extract (500 ${\mu}g/mL$) was measured in a 79.89% free radical scavenging activity, but the flower extracts of similar species (I. britannica var. linariaefolia Regel, I. britannica var. ramosa, I. salicina var. asiatica) did not show any effect on the free radical scavenging activity. The effects of the free radical scavenging activity of I. britannica var. chinensis flower extracts were exhibited in the order of full bloom (93.68%), bud (43.28%), and fallen blossom (14.11%). Next, we established optimum condition of extract solvent, temperature, extraction time. The extract from ethanol at $60^{\circ}C$ showed the most free radical scavenging activity among other conditions and extraction time not relevant in free radical scavenging activity. The protective effects of the extract of I. britannica var. chinensis flower on the photohemolysis of human erythrocytes by using rose bengal were increased in a concentration-dependent manner (5 ~ 50 ${\mu}g/mL$). In particular, the extract in 50 ${\mu}g/mL$ concentration exhibited better protective activity (${\tau}_{50}$ = 116.1 min) than (+)-${\alpha}$-tocopherol (${\tau}_{50}$ = 73.44 min), which is a known lipophilic antioxidant. Principle component of I. britannica var. chinensis flower was identified as quercetin of flavonoids by high-performance liquid chromatography (HPLC). These results indicate that the extract of I. britannica var. chinensis flower can function as antioxidants in biological systems, particularly skin exposed to UV radiation by scavenging free radical and $^1O_2$, and protect cellular membranes against ROS. It is concluded that the antioxidative effects of the extract of I. britannica var. chinensis flower could be applicable to functional cosmetics.

The Plan of Dose Reduction by Measuring and Evaluating Occupationally Exposed Dose in vivo Tests of Nuclear Medicine (핵의학 체내검사 업무 단계 별 피폭선량 측정 및 분석을 통한 피폭선량 감소 방안)

  • Kil, Sang-Hyeong;Lim, Yeong-Hyeon;Park, Kwang-Youl;Jo, Kyung-Nam;Kim, Jung-Hun;Oh, Ji-Eun;Lee, Sang-Hyup;Lee, Su-Jung;Jun, Ji-Tak;Jung, Eui-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.26-32
    • /
    • 2010
  • Purpose: It is to find the way to minimize occupationally exposed dose for workers in vivo tests in each working stage within the range of the working environment which does not ruin the examination and the performance efficiency. Materials and Methods: The process of the nuclear tests in vivo using a radioactive isotope consists of radioisotope distribution, a radioisotope injection ($^{99m}Tc$, $^{18}F$-FDG), and scanning and guiding patients. Using a measuring instrument of RadEye-G10 gamma survey meter (Thermo SCIENTIFIC), the exposure doses in each working stage are measured and evaluated. Before the radioisotope injection the patients are explained about the examination and educated about matters that require attention. It is to reduce the meeting time with the patients. In addition, workers are also educated about the outside exposure and have to put on the protected devices. When the radioisotope is injected to the patients the exposure doses are measured due to whether they are in the protected devices or not. It is also measured due to whether there are the explanation about the examination and the education about matters that require attention or not. The total exposure dose is visualized into the graph in using Microsoft office excel 2007. The difference of this doses are analyzed by wilcoxon signed ranks test in using SPSS (statistical package for the social science) program 12.0. In this case of p<0.01, this study is reliable in the statistics. Results: It was reliable in the statistics that the exposure dose of injecting $^{99m}Tc$-DPD 20 mCi in wearing the protected devices showed 88% smaller than the dose of injecting it without the protected devices. However, it was not reliable in the statistics that the exposure dose of injecting $^{18}F$-FDG 10 mCi with wearing protected devices had 26% decrease than without them. Training before injecting $^{99m}Tc$-DPD 20 mCi to patient made the exposure dose drop to 63% comparing with training after the injection. The dose of training before injecting $^{18}F$-FDG 10 mCi had 52% less then the training after the injection. Both of them were reliable in the statistics. Conclusion: In the examination of using the radioisotope $^{99m}Tc$, wearing the protected devices are more effective to reduce the exposure dose than without wearing them. In the case of using $^{18}F$-FDG, reducing meeting time with patients is more effective to drop the exposure dose. Therefore if we try to protect workers from radioactivity according to each radioisotope characteristic it could be more effective and active radiation shield from radioactivity.

  • PDF