• Title/Summary/Keyword: 2차의 정확도

Search Result 1,615, Processing Time 0.034 seconds

The Optimization of Reconstruction Method Reducing Partial Volume Effect in PET/CT 3D Image Acquisition (PET/CT 3차원 영상 획득에서 부분용적효과 감소를 위한 재구성법의 최적화)

  • Hong, Gun-Chul;Park, Sun-Myung;Kwak, In-Suk;Lee, Hyuk;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.13-17
    • /
    • 2010
  • Purpose: Partial volume effect (PVE) is the phenomenon to lower the accuracy of image due to low estimate, which is to occur from PET/CT 3D image acquisition. The more resolution is declined and the lesion is small, the more it causes a big error. So that it can influence the test result. Studied the optimum image reconstruction method by using variation of parameter, which can influence the PVE. Materials and Methods: It acquires the image in each size spheres which is injected $^{18}F$-FDG to hot site and background in the ratio 4:1 for 10 minutes by using NEMA 2001 IEC phantom in GE Discovey STE 16. The iterative reconstruction is used and gives variety to iteration 2-50 times, subset number 1-56. The analysis's fixed region of interest in detail part of image and compute % difference and signal to noise ratio (SNR) using $SUV_{max}$. Results: It's measured that $SUV_{max}$ of 10 mm spheres, which is changed subset number to 2, 5, 8, 20, 56 in fixed iteration to times, SNR is indicated 0.19, 0.30, 0.40, 0.48, 0.45. As well as each sphere's of total SNR is measured 2.73, 3.38, 3.64, 3.63, 3.38. Conclusion: In iteration 6th to 20th, it indicates similar value in % difference and SNR ($3.47{\pm}0.09$). Over 20th, it increases the phenomenon, which is placed low value on $SUV_{max}$ through the influence of noise. In addition, the identical iteration, it indicates that SNR is high value in 8th to 20th in variation of subset number. Therefore, to reduce partial volume effect of small lesion, it can be declined the partial volume effect in iteration 6 times, subset number 8~20 times, considering reconstruction time.

  • PDF

Children′s Attitudes Toward Food Advertisement on Children′s Television Program (어린이 시간대 식품광고에 대한 어린이들의 수용 태도)

  • 김경희;강금지
    • Korean journal of food and cookery science
    • /
    • v.13 no.5
    • /
    • pp.648-660
    • /
    • 1997
  • The study was conducted to investigate children's attitudes toward food advertisement on children's television programs. A total of 868 subjects were selected from two KangNam and KangBook elementary schools (4, 5, 6th graders). First, it was reviewed food ads. On children's television program on 3 channels between 5∼7 pm from April to July in 1997. Among the total television commercials, 58% were food product ads.. Among the advertised food, the largest number of ads. was for beverages (21.6%) and the next was for cookies (19.7%), followes by sharbet and ice cream (19.5%), fast food (12.4%), cereal (5.5%) and milk and milk products (2.9%). This review revealed that the mostly advertised food are high in calorie, fat and sugar. Secondly, it was conducted a survey. The results of the survey were as follows: weekly average TV watching hours per child: 13.5. 50.8% of the children watched children's program on TV. 83.9% of the subjcts answered that they get their information about new food through TV ads.. 59.2% of children tried to buy the food advertised on TV program. The relationship between TV food ads. and health, 49.4% of the children answered that advertised food were not good for one's health. When we asked them to choose between advertised and non-advertised food, they preferred the advertised ones, such as cookies, beverages, fast food restaurants and cereals (p<0.001). The results of this study suggest that children's purchasing and selecting of food were influenced by TV food advertisement. Therefore, education is needed which will help children's make responsible, informed consumers choices.

  • PDF

A Clinical Study of Hypertrophic Pyloric Stenosis (비후성 유문 협착증의 임상적 고찰)

  • Kim, Yoon Hee;Jung, Myung Sup;Byun, Soon Ok
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.11
    • /
    • pp.1389-1396
    • /
    • 2002
  • Purpose : This study was done to analyze the changes in the clinical conditions and the diagnosis of hypertrophic pyloric stenosis. Methods : We report a retrospective clinical analysis of 39 patients with hypertrophic pyloric stenosis from Jan. 1992 to Aug. 2001. The age and sex distribution, family and birth history, clinical symptoms, the ultrasonographic and the operative sizes of pyloric canals were compared. Results : The body weight was below the 3 percentile at admission in eight cases(20.5%). "Olive like mass" in right upper quadrant was palpated during physical examination in 23 cases(59%) and gastric peristaltic wave observed in six cases(15%). The ultrasonographic measurements showed that the pyloric muscle thickness to be $4.95{\pm}0.99mm$($mean{\pm}SD$), pyloric diameter $14.42{\pm}2.64mm$, and pyloric length $20.17{\pm}3.92mm$. Fredet-Ramstedt pyloromyotomy was employed in all cases. The operative measurements of the pyloric muscle thickness was $5.11{\pm}1.01mm$, pyloric diameter $15.01{\pm}2.47mm$, and pyloric length $22.32{\pm}3.43mm$. Conclusion : There was no significant difference between the ultrasonographic and operative measurements. Currently, the hypertrophic pyloric stenosis patients showed lesser clinical hallmarks of the disease. The earlier diagnosis using imaging studies before development of significant metabolic abnormalities is becoming an important factor that change the future outcomes of hypertrophic pyloric stenosis.

Nontuberculous Mycobacterial pulmonary Infection in Immunocompetent Patients (면역적격자에서 비결핵마이코박테리아의 폐감염)

  • Lee, Hyo-Won;Kim, Mi-Na;Shim, Tae-Sun;Bai, Gill-Han;Pai, Chik-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.2
    • /
    • pp.173-182
    • /
    • 2002
  • Background : Nontuberculous mycobacteria (NTM) have usually been considered to be contaminants of colonizers when isolated from respiratory specimens in Korea, where there is a high prevalence of tuberculosis and a low rate of HIV infections. Therefore, there has been few studies on the clinical significance of NTM species in immunocompetent patients were investigated. Methods : Thirty-five NTM isolates, for which species identification was requested by the treating physicians during 1999 at the Asan Medical Center, were retrospectively analyzed. They were identified to the species level by mycolic acid analysis using high-performance liquid chromatography. The medical records of the patients with the NTM isolates were reviewed to identify those patients who met the American Thoracic Society (ATS)'s criteria for mycobacterial pulmonary infection. Their antimicrobial susceptibility data were compared with the clinical outcomes. Results : The NTM were identified as M. intracellulare (6 isolates), M. avium (5), M. abscessus (5), M. gordonae (5), M. terrae complex (4), M. szulgai (2), M. kansasii (2), M. fortuitum (2), M. peregrinum (1), M. mucogenicum (1), M. celatum (1), and M. chelonae (1). All 35 patients showed clinical symptoms and signs of chronic lung disease, but none had a HIV infections; 16 (45.7%) patients were found to be compatible with a NTM pulmonary infection according to the ATS criteria, 5 and 4 cases were affected with M. intracellulare and M. abscessus, respectively; 8 patients had a history of pulmonary tuberculosis. 13 patients received antimycobacterial therapy for an average of 21 months and 9 patients were treated with second-line drugs. Only 4 patients had improved radiologically. Conclusion : A NTM should be considered a potential pathogen of pulmonary infections in immunocompetent patients with chronic pulmonary diseases. Most NTM infections were left untreated for a prolonged period and showed a poor outcome as a result, M. intracellulare and M. abscessus were the two most frequent causes of NTM pulmonary infections in this study. Species identification and antimycobacterial susceptibility tests based on the species are needed for the optimum management of a NTM pulmonary infection in patients.

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

Measurement of Spatial Scattered Dose Distribution According to Presence or Absence of Radiation Shielding in the Operating Room (수술실에서 방사선 차폐기 사용 유무에 따른 공간산란선량분포의 측정)

  • Do, Sang-Lock;Cho, Pyong-Kon;Kim, Seong-Jin;Jung, Dong Kyung
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.549-556
    • /
    • 2017
  • This study compared the spatial scattered dose distribution according to whether the recently developed radiation shielding is used or not in order to understand the spatial scattered dose distribution of C-arm. The horizontal side distribution increased by $30^{\circ}$ in the interval of the radius 50 cm on the height of 95 cm based on the head of the patient, and it was measured by increasing $30^{\circ}$ with the interval of 50 cm in the vertical side of each horizontal side. In the same method, the radiation shielding was installed and measured. The result of measurement shows that the horizontal side of 50 cm distance was $0^{\circ}$, $90^{\circ}$ and $180^{\circ}$, was $1.77{\pm}0.12$, $1.90{\pm}0.13$, $2.12{\pm}0.14$, and $2.69{\pm}0.15mSv/h$ in the $270^{\circ}$ direction, and was $1.59{\pm}0.12$, $0.99{\pm}0.09$, $1.47{\pm}0.11$, and $1.37{\pm}0.11mSv/h$ after the use of the radiation shielding. In addition, the vertical distribution in horizontal direction $90^{\circ}$ with 50 cm distance was $30^{\circ}$, $60^{\circ}$, $120^{\circ}$, was $3.85{\pm}0.18$, $9.15{\pm}0.28$, $10.82{\pm}0.31$, and $5.40{\pm}0.22mSv/h$ in $150^{\circ}$, and was $2.03{\pm}0.13$, $4.32{\pm}0.19$, $2.76{\pm}0.16$, and $1.92{\pm}0.13mSv/h\;mR/h$ after the use of the radiation shielding. Both direction showed decrease according to the use of the radiation shielding. Therefore, radiation related workers who work in operating rooms should recognize the spatial scattered dose distribution exactly and need to try to prevent the risk of radiation exposure with proper protective measures.

Validation of Surface Reflectance Product of KOMPSAT-3A Image Data: Application of RadCalNet Baotou (BTCN) Data (다목적실용위성 3A 영상 자료의 지표 반사도 성과 검증: RadCalNet Baotou(BTCN) 자료 적용 사례)

  • Kim, Kwangseob;Lee, Kiwon
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_2
    • /
    • pp.1509-1521
    • /
    • 2020
  • Experiments for validation of surface reflectance produced by Korea Multi-Purpose Satellite (KOMPSAT-3A) were conducted using Chinese Baotou (BTCN) data among four sites of the Radical Calibration Network (RadCalNet), a portal that provides spectrophotometric reflectance measurements. The atmosphere reflectance and surface reflectance products were generated using an extension program of an open-source Orfeo ToolBox (OTB), which was redesigned and implemented to extract those reflectance products in batches. Three image data sets of 2016, 2017, and 2018 were taken into account of the two sensor model variability, ver. 1.4 released in 2017 and ver. 1.5 in 2019, such as gain and offset applied to the absolute atmospheric correction. The results of applying these sensor model variables showed that the reflectance products by ver. 1.4 were relatively well-matched with RadCalNet BTCN data, compared to ones by ver. 1.5. On the other hand, the reflectance products obtained from the Landsat-8 by the USGS LaSRC algorithm and Sentinel-2B images using the SNAP Sen2Cor program were used to quantitatively verify the differences in those of KOMPSAT-3A. Based on the RadCalNet BTCN data, the differences between the surface reflectance of KOMPSAT-3A image were shown to be highly consistent with B band as -0.031 to 0.034, G band as -0.001 to 0.055, R band as -0.072 to 0.037, and NIR band as -0.060 to 0.022. The surface reflectance of KOMPSAT-3A also indicated the accuracy level for further applications, compared to those of Landsat-8 and Sentinel-2B images. The results of this study are meaningful in confirming the applicability of Analysis Ready Data (ARD) to the surface reflectance on high-resolution satellites.

Comparison of Carbon Storage Based on Alternative Action by Land Use Planning (토지이용에 따른 대안별 탄소 저장량 비교)

  • Seulki Koo;Youngsoo Lee;Sangdon Lee
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.6
    • /
    • pp.377-388
    • /
    • 2023
  • Carbon management is emerging as an important factor for global warming control, and land use change is considered one of the causes. To quantify the changes in carbon stocks due to development, this study attempted to calculate carbon storage by borrowing the formula of the InVEST Carbon Storage and Sequestration Model (InVEST Model). Before analyzing carbon stocks, a carbon pool was compiled based on previous studies in Korea. Then, we estimated the change in carbon stocks according to the development of Osong National Industrial Park (ONIP) and the application of alternatives. The analysis shows that 16,789.5 MgC will be emitted under Alternative 1 and 16,305.3 MgC under Alternative 2. These emissions account for 44.4% and 43.1% of the pre-project carbon stock, respectively, and shows that choosing Alternative 2 is advantageous for reducing carbon emissions. The difference is likely due to the difference in grassland area between Alternatives 1 and 2. Even if Alternative 2 is selected, efforts are needed to increase the carbon storage effect by managing the appropriate level of green cover in the grassland, creating multi-layered vegetation, and installing low-energy facilities. In addition, it is suggested to conserve wetlands that can be lost during the stream improvement process or to create artificial wetlands to increase carbon storage. The assessment of carbon storage using carbon pools by land cover can improve the objectivity of comparison and evaluation analysis results for land use plans in Environmental Impact Assessment and Strategic Environmental Impact Assessment. In addition, the carbon pool generated in this study is expected to be used as a basis for improving the accuracy of such analyses.

The Development of the Korean Form of Childhood Attention Problem(CAP) Scale: A Study on the Reliability and Validity (한국형 소아기 집중력 문제척도: 신뢰도 및 타당도 연구)

  • Seo, Wan-Seok;Lee, Jong-Bum;Park, Hyung-Bae;Suh, Hyea-Soo;Lee, Kwang-Hun;SaKong, Jeong-Kyu
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.123-136
    • /
    • 1997
  • The purpose of this study was to examine the reliability and validity of a Korean form of Childhood Attention Problem(CAP) scale. CAP were administered to 98 normal elementary school students as control group and 98 attention deficit hyperactivity disorder patients. Male students showed high scores than female students in both subscale and total scores, but not statistically significant. There were no significant difference in CAP scale between male students and female students in attention deficit hyperactivity disorder patients. In the reliability test, the test-retest reliability coefficient was highly satisfactory and that of inattention subscale was 0.83, impulsivity subscale was 0.70 and total score was 0.82. In the reliability test by internal consistency, the Cronbach $\alpha$ coefficient was highly satisfactory and that of inattention subscale was 0.91, overactivity subscale was 0.89(p<0.05). The concurrent validity between CAP scale and ADDES-BV scale was 0.85 in attention deficit hyperactivity disorder patient group and 0.73 in normal control group(p<0.05). In discriminant validity test between attention deficit hyperactivity disorder patient group and normal control group, the patient group showed higher score(p<0.05). The total discriminant capacity of the patient group in CAP was 93.4%. In this point of view, CAP scale showed high reliability and validity in applying to Korean subjects and was proved to be the good and simple screening test tool for attention deficit hyperactivity disorder research and can help many young patient to treat early.

  • PDF

Efficacy and Cost Benefits of Rapid Antigen Detection Test for Group A Streptococci Obtained from Acute Pharyngitis in Children (소아 세균성 인두 편도염의 진단에 있어 신속 항원 검출 검사의 유용성과 비용 효과의 평가)

  • Youn, Suk;Chung, Hye-Jeon;Kim, Yun-Ho;Choi, Jin-Dong;Lee, Sang-Hoon;Min, Jung-Sik;Jung, Sang-Young;Jung, Sung-Ki;Ahn, Byung-Moon;Lee, Hee-Joo;Cha, Sung-Ho
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.124-134
    • /
    • 2005
  • Purpose : It has been known that the diagnostic confirmation of group A streptococcal pharyngitis is accompanied with the results of throat culture and/or rapid antigen detection test(RADT). This study was designed to evaluate the usefulness and cost benefits of the RADT in patients with a sore throat compared the empirical antibiotic treated group without using RADT or throat culture with the antibiotic treated group according to the results of RADT test and/or throat culture. Methods : From April 2003 to August 2003, total 369 patients were enrolled this study. They were redistributed into two groups. In one group, the RADT test and throat culture were used and the patients received antibiotic treatment according to the results of test and in the other group, no diagnostic examinations were used and the patients were treated with antibiotics which were chosen empirically. The flow sheet with questionnaire was drawing up and obtained the clinical symptoms, signs and the name of antibiotics that were administered. Results : A total of 244 patients were treated after the throat culture and/or RADT, and 125 patients were treated empirically. The prevalence of bacteriologically confirmed group A streptococcal pharyngitis was 20.1%. The sensitivity and specificity of RADT were 89.8% and 86.1%, respectively. Positive predictive value and negative predictive value were 62.0% and 97.1%, respectively. The rate of antibiotic use was high in both groups. Because the physician used the antibiotics even if the result of RADT was negative. So about 37% of reduction of antibiotics use might be possible if we used antibiotics according to the results of RADT. There were no cost differences between the RADT applied group and the empirically treated antibiotic group if we could reduce the price of RADT to 63% of the current price. Conclusion : The RADT could be applied for the easy and rapid diagnosis and prompt treatment for group A streptococcal pharyngitis, and RADT could reduced the number of antibiotics used if the price of RADT was reduced to 63% of current price. For accurate evaluation of efficacy and cost effect, further controlled study is needed.

  • PDF