• Title/Summary/Keyword: 2중 파장법

Search Result 127, Processing Time 0.063 seconds

A 3D measurement system based on a double frequency method using Fourier transform profilometry (FTP를 이용한 이중 파장법에 의한 3차원 형상 측정)

  • Koo, Ja-myoung;Cho, Tai-hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1485-1492
    • /
    • 2015
  • This paper proposes a double frequency method using FTP(Fourier Transform Profilometry) in fringe projection techniques for 3D measurement systems. In fringe projection techniques, fringe pattern images are projected and captured, and then object is measured by analysing phase. PMP(Phase Measuring Profilometry) for analysing phase provides high-resolution and is robust to object's reflection and background intensities. However, the measurement range is narrow due to 2π ambiguity. In order to overcome this problem, a double frequency method is often used. This method can widen the range of measurement while maintaining the high-resolution, but the measurement time is taken about twice due to grab 2 times number of images. The proposed double frequency method using FTP requires an additional image for resolving 2π ambiguity. The proposed method effectively reduces the measurement time while maintaining the same accuracy.

2중파장 영사식 무아레의 N-Buckets 알고리즘 오차비교에 관한 실험적 연구

  • 유원재;박낙규;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.181-181
    • /
    • 2004
  • 3 차원 형상측정기술(3-D Profile Measurement Method)은 가공품의 치수검사 및 형상측정 등의 공학분야뿐만 아니라 최근에는 의류산업 및 의학산업은 물론 오락산업의 가상현실 구현 등 여러 분야로 점차 사용이 확대되고 있다. 이러한 요구를 만족시킬 수 있는 광학을 바탕으로 한 비접촉 3 차원 형상측정방법(Non-contacting 3-D Profile Measuring Method)은 고속, 고정밀도 측정이 가능하기 때문에 활발히 연구되고 있다. 광학을 이용한 대표적인 3 차원 비접촉 측정방법의 하나인 영사식 무아레는 그림자식 무아레의 단점인 격자의 크기가 측정물체보다 커야 한다는 점과 측정물체와 격자사이의 거리 제한 문제를 해결하였으며, 위상이동법을 사용함으로서, 무아레 무늬 형태의 영향을 받지 않고 측정이 가능해졌다.(중략)

  • PDF

Deconvolution of UV Spectrum for Selective Measurement of $ClO_2$ Concentration Quantitatively in Solution Containing Various Chlorine Species (다양한 염소 종이 함유된 수용액에서 자외선 흡수 파장 분해법을 이용한 이산화염소 선별 정량 분석)

  • Byun, Youngchul;Kim, Jaehoon;Jang, Yumi;Lee, Kiman;Lee, Jae Myeong;Shin, Dong Nam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.743-750
    • /
    • 2012
  • An ultraviolet (UV) absorption method has a difficulty to analyze $ClO_{2(aq)}$ in solutions containing various chlorine species because UV spectrum of $ClO_{2(aq)}$ overlaps with other chlorine-containing species. This study has proposed the deconvolution method of UV spectrum to analyze $ClO_{2(aq)}$ concentration quantitatively in solution containing various chlorine species. We compared results obtained from UV deconvolution method with titration method. Good agreement of $ClO_{2(aq)}$ concentration between them has been shown in about 10%. This result informs us that the deconvolution method of UV spectrum could be a feasible for the analysis of $ClO_{2(aq)}$ in solution containing various chlorine species.

Measurement of Sulfur Dioxide Concentration Using Wavelength Modulation Spectroscopy With Optical Multi-Absorption Signals at 7.6 µm Wavelength Region (7.6 µm 파장 영역의 다중 광 흡수 신호 파장 변조 분광법을 이용한 이산화황 농도 측정)

  • Song, Aran;Jeong, Nakwon;Bae, Sungwoo;Hwang, Jungho;Lee, Changyeop;Kim, Daehae
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.293-303
    • /
    • 2020
  • According to the World Health Organization (WHO), air pollution is a typical health hazard, resulting in about 7 million premature deaths each year. Sulfur dioxide (SO2) is one of the major air pollutants, and the combustion process with sulfur-containing fuels generates it. Measuring SO2 generation in large combustion environments in real time and optimizing reduction facilities based on measured values are necessary to reduce the compound's presence. This paper describes the concentration measurement for SO2, a particulate matter precursor, using a wavelength modulation spectroscopy (WMS) of tunable diode laser absorption spectroscopy (TDLAS). This study employed a quantum cascade laser operating at 7.6 ㎛ as a light source. It demonstrated concentration measurement possibility using 64 multi-absorption lines between 7623.7 and 7626.0 nm. The experiments were conducted in a multi-pass cell with a total path length of 28 and 76 m at 1 atm, 296 K. The SO2 concentration was tested in two types: high concentration (1000 to 5000 ppm) and low concentration (10 ppm or less). Additionally, the effect of H2O interference in the atmosphere on the measurement of SO2 was confirmed by N2 purging the laser's path. The detection limit for SO2 was 3 ppm, and results were compared with the electronic chemical sensor and nondispersive infrared (NDIR) sensor.

Discrimination of Pasture Spices for Italian Ryegrass, Perennial Ryegrass and Tall Fescue Using Near Infrared Spectroscopy (근적외선분광법을 이용한 이탈리안 라이그라스, 페레니얼 라이그라스,톨 페스큐 종자의 초종 판별)

  • Park, Hyung Soo;Choi, Ki Choon;Kim, Ji Hye;So, Min Jeong;Lee, Ki Won;Lee, Sang Hoon
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.35 no.2
    • /
    • pp.125-130
    • /
    • 2015
  • The objective of this study was to investigate the feasibility of using near infrared spectroscopy (NIRS) to discriminate between grass spices. A combination of NIRS and chemometrics was used to discriminate between Italian ryegrass, perennial ryegrass, and tall fescue seeds. A total of 240 samples were used to develop the best discriminant equation, whereby three spectra range (visible, NIR, and full range) were applied within a 680 nm to 2500 nm wavelength. The calibration equation for the discriminant analysis was developed using partial least square (PLS) regression and discrimination equation (DE) analysis. A PLS discriminant analysis model for the three spectra range that was developed with the mathematic pretreatment "1,8,8,1" successfully discriminated between Italian ryegrass, perennial ryegrass, and tall fescue. An external validation indicated that all of the samples were discriminated correctly. The discriminant accuracy was shown as 68%, 78%, and 73% for Italian ryegrass, perennial ryegrass, and tall fescue, respectively, with the NIR full-range spectra. The results demonstrate the usefulness of the NIRS-chemometrics combination as a rapid method for the discrimination of grass species by seed.

A Study on the Virtual Grating Projection Moire Topography for the Shape Measurement of Human Face (인체형상 측정을 위한 가상격자 영사식 무아레 방법에 관한 연구)

  • 유원재;최정표;안중근;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.49-52
    • /
    • 2001
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topogrphy is very attractive because of it s high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the $2\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi$-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF

Variey Discrimination of Sorghum-Sudangrass Hybrids Seed Using near Infrared Spectroscopy (근적외선분광법을 이용한 수수×수단그라스 교잡종 종자의 품종 판별)

  • Lee, Ki-Won;Song, Yowook;Kim, Ji Hye;Rahman, Md Atikur;Oh, Mirae;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.40 no.4
    • /
    • pp.259-264
    • /
    • 2020
  • The aim of this study was to investigate the feasibility of discrimination 12 different cultivar of sorghum × sudangrass hybrid (Sorghum genus) seed through near infrared spectroscopy (NIRS). The amount of samples for develop to the best discriminant equation was 360. Whole samples were applied different three spectra range (visible, NIR and full range) within 680-2500 nm wavelength and the spectrastar 2500 Near near infrared was used to measure spectra. The calibration equation for discriminant analysis was developed partial least square (PLS) regression and discrimination equation (DE) analysis. The PLS discriminant analysis model for three spectra range developed with mathematic pretreatment 1,8,8,1 successfully discriminated 12 different sorghum genus. External validation indicated that all samples were discriminated correctly. The whole discriminant accuracy shown 82 ~ 100 % in NIR full range spectra. The results demonstrated the usefulness of NIRS combined with chemometrics as a rapid method for discrimination of sorghum × sudangrass hybrid cultivar through seed.

Optical Properties of $TiO_2$ Thin Films Prepared by Ion-beam Assisted Deposition (이온빔 보조 증착법에 의해 제작된 $TiO_2$ 박막의 광학적 특성)

  • 조현주;이홍순;황보창권;이민희;박대윤
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.9-17
    • /
    • 1994
  • Optical properties of $TiO_2$ thin films prepared by ion-beam assisted deposition(1BAD) were investigated. The result shows that the refractive index of IBAD TiOL thin films measured by an envelope method is closer to that of the corresponding bulk than that of conventionally deposited $TiO_2$ thin films and the packing density of IBAD $TiO_2$ thin films measured by a vacuum-to-air spectral shift of films increases drastically. The vacuum-to-air spectral shift of an IBAD $(TiO_2/SiO_2)$ multilayer interference filter was negligible as compared to that of a conventional interference filter and so the IBAD filter is denser and more stable optically than the conventional filter. Also it is observed that the IBAD and conventional $TiO_2$ thin films are stoichiometric and amorphous.

  • PDF

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 유원재;김도훈;안재웅;강영준;노형민
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.199-202
    • /
    • 2002
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2$\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the flour-three step algorithm method than the same step in the phase shifting of different pitchs.

  • PDF