• Title/Summary/Keyword: 2면 접착

Search Result 185, Processing Time 0.022 seconds

Thickness Measurement of Adhesive Layer of Multilayer Using Power Cepstrum Technique (전력 켑스트럼 기법을 이용한 다층구조물 접착면의 두께측정)

  • Shin, Jin-Seob;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.26-30
    • /
    • 1997
  • In this paper, the thickness measurement method of adhesive layers of multilayers using power cepstrum signal processing technique has been proposed. The peak values for reflected signal from each layer have been separated by power cepstrum technique. Therefore, thickness of adhesive layers have been measured by the intervals of peak signal. In the experiment, the adhesive layers of 0.5mm-0.75mm thickness using epoxy(2-Ton and Plastic Steel Putty(A)) between the aluminum and the brass were formed. The adhesive layer thickness which is calculated with data of reflected signal by ultrasonic pulse-echo method was within error 1.34% of the measured values.

  • PDF

The Effect of Tin Ion-plating on the Bond Strength of Orthodontic Bracket (TiN Ion-Plating이 교정용 브라켓의 접착강도에 미치는 영향)

  • KIM, Seok-Yong;KWON, Oh-Won;KIM, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.157-171
    • /
    • 1997
  • This study was conducted to see the effect of TiN ion-plating on the bond strength of orthodontic bracket. Three stainless-steel brackets with different base types were chosen; when TiN ion-plated brackets and non iorrplated brackets were bonded to the teeth, initial and long-term bond strength were measured, The observations oi bonding surface and failure sites through the scanning electron microscope were analysed and compared. The summary of this study was as follows; ${\cdot}$ When TiN ion-plating was not applied, the Micro-Loc type was the highest in bond strength atter 24 hours as $5.89{\pm}1.77$ MPa, followed by $4,27{\pm}1.12MPa$ for Foil Mesh type and $2.64{\pm}0.58MPa$ for Undercut type(P<0.05). ${\cdot}$ Under TiN ion-plating, the bond strength after 24 hours showed: Micro-Loc type $-6.26{\pm}1.51MPa$, Foil Mesh type $-7.45{\pm}2.01MPa$, Undercut type $-2.93{\pm}0.84MPa$. Unlike in the case of non ion-plating, Foil Mesh type showed a higher strength than Micro-Loc type, with Undercut type still showing the lowest bond strength(P<0.05). The bond strength, after 24 hours, increased in case of ion-plated in all 3 types, but a significant increase was shown only in Foil Mesh type(P<0.001). ${\cdot}$ Under a long-term immersion, regardless of ion or non ion-plating, bond strength in general increased over the initial bond strength(one day), with more stability. ${\cdot}$ Through scanning electron microscopic observation of bonding surface, it was found that, regardless of the bracket base type or the application of ion-plating, the resin was thoroughly spreaded into bracket base to form a solid bonding surface between the bracket and the tooth. This was also true in case of a long-term immersion. ${\cdot}$ The scanning electron microscopic observation of failure sites revealed diverse failure patterns.

  • PDF

EFFECT OF DENTIN SURFACE WETNESS ON TENSILE BOND STRENGTH OF SELF ADHESIVE RESIN CEMENTS (상아질 표면 젖음성이 수종 자가접착레진시멘트의 인장접착강도에 미치는 영향)

  • Yoon, Sung-Young;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.113-119
    • /
    • 2009
  • The purpose of this study was to compare the tensile bond strength of several self-adhesive resin cements bonded to dentin surfaces with different wet conditions. Three self-adhesive resin cements: Rely-X Unicem (3M ESPE, St. Paul, MN. USA). Embrace Wetbond (Pulpdent. Oakland. MA. USA). Maxcem (Kerr. Orange. CA. USA) were used. Extracted sixty human molars were used. Each self-adhesive resin cement was adhered to the dentin specimens (two rectangular sticks from each molar) in different wet conditions. Tensile bond strength were measured using universal testing machine (EZ Test. Shimadzu corporation. Kyoto. Japan) at a crosshead speed of 1.0mm/min. After the testing. bonding failures of specimens were observed by Operative microscope (OPMI pro, Carl Zeiss. Oberkochen, Germany). T-test was used to evaluate the effect of dentin surface wetness. One-way ANOVA test was used to evaluate the tensile bond strength of self-adhesive resin cements in the same condition. Scheffe's test was used for statistical analyzing at the 95% level of confidence. The result showed that wetness of dentin surface didn't affect tensile bond strength of self-adhesive resin cements and Maxcem showed the lowest tensile bond strength.

PREVENTIVE EFFECT OF ADHESIVE TAPE SUPPLEMENTED WITH NaF ON ENAMEL EROSION IN VITRO (불소함유 접착테잎의 법랑질 침식 예방효과)

  • Lee, Sang-Ho;Lee, Nan-Young;Lee, In-Hwa
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.82-90
    • /
    • 2010
  • This study examined the effect of adhesive tape supplemented with sodium fluoride on the prevention of dental erosion in vitro. Sound bovine tooth samples were selected and divided randomly into the following 4 groups according to the material treatments: group 1, APF gel; group 2, fluoride varnish; and groups 3 and 4, fluoride tape supplemented with 5% NaF in either a methyl cellulose or poly vinyl acetate carrier, respectively. All specimens were submitted to alternate cycles of acid exposure in a cola beverage (pH 4.3) and artificial saliva for $6\;{\times}\;5\;min/day$ over a 5 day period. The micro-hardness was recorded each day and the lesion depth was measured after 5 days. The micro-hardness of the experimental sides of groups 2, 3 and 4 were significantly higher than that of their control sides and the experimental side of group 1 during the experimental period (p<0.05) except on the 5th day. The enamel surfaces of treatment groups 2, 3 and 4 showed significantly higher resistance to mineral loss in terms of the erosion depth (p<0.05) than group 1 and their control sides. There was no statistically significant difference among group 2, 3 and 4, indicating that the fluoride varnish and tapes produce similar results. Fluoride adhesive tapes are effective in reducing the progression of erosion and can be recommended for young patients who are more susceptible to dental erosion.

An Experimental Study on the Period of Cold Joint Occurrence Effecting Shear Bond Performances of UHSCC (콜드조인트 발생시간이 초고강도 섬유보강 시멘트 복합체의 전단 접착 성능에 미치는 영향에 관한 실험적 연구)

  • Kim, Min-Seong;Yang, Hyun-Min;Lee, Han-Seung;Cho, Keun-hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.25-32
    • /
    • 2016
  • The purpose of this study is to evaluate the performance on the compressive bonding shear strength of ultra-high strength steel fiber reinforced cementitous composites(UHSCC). As a result of compressive bonding shear strength through Direct shear test, It was found that the specimen($150{\times}150{\times}150mm$) of NC(Normal concrete) + NC showed similar compressive bonding shear strength at whole experimental level. On the other hand, the specimen of UHSCC + UHSCC showed decrease of compressive bonding shear strength from after 30 minutes of the retarded placement than 0 minute. As a result of analyzing failure mode of bonding interface, It was found that the specimen of NC + NC showed mixed failure at whole experimental level. In case of the specimen of UHSCC + UHSCC, it showed interface failure from the specimen that are 30 minutes, 60 minutes and 90 minutes of delay of concrete placing. As a result of analyzing XRD test in terms of the placement interface on the specimen of NC and UHSCC, relatively much amount of $SiO_2$ was detected from the specimen of UHSCC than that of NC. It is judged that the most of main components of coating film shown in the specimen of UHSCC is $SiO_2$. In conclusion, it is judged that UHSCC which is made from after 30 minutes of delay of concrete placing is unable to be used as structural member because of deterioration of bonding performance. From later study, it is judged that the improvement of bonding performance from the part of cold joint occurrence is necessary through the interface preparation method.

A Fundamental Study on Induction Technology of Separation Behavior Using Two-sided Adhesion of Joint of Composites Waterproofing System (시트-도막 복합방수공법의 접합부 2면 접착을 통한 분리거동 유도 기술에 관한 기초적 연구)

  • Park, Jin-Sang;Lee, Tae-Yang;Kim, Dong-Bum;Park, Wan-Goo;Heo, Neung-Hoe;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.3
    • /
    • pp.212-219
    • /
    • 2015
  • This study focuses evaluating the efficiency and performance evaluation of composite type sheet-membrane waterproofing method that utilizes a separation behavior inducement system designed to resolve the chronic problems of disintegration and damage of overlap areas of waterproofing layers. As the result of the test, the tensile strength value was at 13.8N/mm and elongation rate at 587% for the separation behavior inducement type specimen, and the compared specimens had 14.2N/mm for tensile strength and 335% for elongation rate. For the separation behavior adhesion method specimen, when tensile stress or displacement occurred, the Zero-Span tension occurrence did not follow, which resulted in that the bottom sheet layer and the top membrane layer did not simultaneously becoming damaged. When undergoing the top and bottom layers were separated through separation behavior due to lack of flexibility, the bottom layer began to damage at the primary stage, and with the allowed boundary the upper membrane layer began to display flexibility and showed continuous displaced resulting in secondary phase damaging.

Shear bond strength of ceramic and resin brackets used with visible light-cured adhesives (도재 및 레진 브라켓에 대한 광중합 접착제의 전단 접착 강도)

  • Hwang, Yu-Sun;Row, Joon;Hwaang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.233-244
    • /
    • 1996
  • The purpose of this study was to compare the shear bond strength obtained from ceramic and plastic brackets bonded with various light-cured adhesives and to evaluate their debonded failure sites. Plastic brackets, Transcend 6000, Signature and Starflre TMB brackets were bonded with Orthobond, Light Bond and Transbond on one hundred forty extracted human premolar teeth as manufacturer's descriptions. After thermocycling the brackets were debonded with an Instron universal testing machine and the debonded bracket base surfaces were inspected under stereoscope to evaluate the failure sites. Also the shear bond strength and failure patterns with different curing time and with two different source of light were compared. The results were as follows. 1. There were no statistically significant differences among the mean shear bond strength of Orthobond, Light Bond and Transbond in a same bracket group except Plastic bracket group(p<0.05). 2. The mean shear bond strength of each adhesive with different bracket groups showed statistically significant differences. Stafire TMB showed the highest shear bond strenght among the brackets in this study, but there was no statistically singnificant difference with Transcend 6000 while there was statistically significant difference with Signature.(p<0.05) 3. The various bonding failure patterns were occurred among different bracket groups but most of failure sites were bracket base -adhesive interfaces. 4. There were no statistically significant differences in shear bond strength between the groups with curing time of 10 second and 20 second, and between the groups with two different sources of light as long as sufficient light intensity(above $400mWcm^2$) were provided(p<0.05). According to the result, it should be considered in clinical use of ceramic bracket with light-cured adhesives that the shear strengths of ceramic brackets were influenced by the retention from of bracket base as well as the composition of bracket and there was no difference in the shear bond strenght among various light-cured adhesives used in this study.

  • PDF

The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods (브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교)

  • Shin, Jai-Ho;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.333-342
    • /
    • 2004
  • The purpose of this study was to evaluate the clinical effectiveness of a plasma arc light and light emitting diode (LED), compared with shear bond strength and the failure pattern of brackets bonded with visible light in direct bonding. Brackets were bonded with Transbond XT to 60 human premolars embedded in the resin blocks according to different light-curing methods. Then, the shear bond strength of each group was measured using a universal testing machine (Instron) and the adhesive failure pattern after debonding was visually examined by light microscope. The results were as follows: 1. The shear bond strength showed no significant difference between the visible light and light emitting diode, but the plasma arc light exhibited a significantly lower shear bond strength compared with the visible light and light emitting diode. 2. In the visible light and light emitting diode, adhesive failure patterns were similar. Bond failure occurred more frequently at the enamel-adhesive interface. 3. The bonding failure of brackets bonded with plasma arc light occurred more frequently at the bracket-adhesive interface. The results of this study suggest that plasma arc light, light emitting diode and visible light are all clinically useful in the direct bonding of orthodontic brackets.

Dual-purpose Reagent for Separating Paper with Tape and Developing Fingerprints on the Paper Simultaneously (종이에 부착된 테이프를 박리하는 동시에 지문을 현출하는 이중목적시약(dual-purpose)에 관한 연구)

  • Seo, Youn-Hee;Kim, Yeon-Ji;Shin, Min-Seop;Yu, Je-Seol
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.1
    • /
    • pp.463-471
    • /
    • 2019
  • Tapes are usually used in violent crimes and may contain important evidence. Separating adhesive side should be preceded to collect these evidence. In this study, we researched a novel dual-purpose reagent that can separate the tape without damaging and develop the fingerprints on porous surface when the tape is attached to A4 paper. As a result, the reagent of 1:2 ratio of 1,2-IND stock solution and HFE-7100 can separate without damaging the adhesive surface and develop fingerprints on separated A4 paper.

Priming time and etching effect on shear bond strength of self-etching adhesive (프라이머 처리시간과 산부식이 자가산부식 접착제의 접착강도에 미치는 영향)

  • Kang, In-Joo;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.185-190
    • /
    • 2004
  • 자가산부식 접착제 (self-etching primer)는 법랑질과 상아질을 동시에 산부식과 프라이머 처리를 함으로 임상 시술 시간을 단축시킬 뿐만 아니라, 임상과정 중 발생할 수 있는 술자의 실수 및 타액등에 의한 오염의 가능성을 줄일 수 있는 장점을 가지고 있다. 그러나 약산을 이용한 산부식법이 법랑질에 대해 탈회효과 및 접착강도에 있어 논란이 되고 있다. 이에 본 연구에서는 인산을 이용한 추가적인 산부식 및 자가산부식 접착제의 적용시간을 달리할 경우 법랑질에 대한 접착강도의 변화를 알아보고자 하였다. 135개의 발거한 우치의 법랑질 면을 #600사포로 연마한 후 9개의 군으로 분류하였다. 각 군은 부가적인 32% 인산을 처리하지 않은 군 (1~3군), 15초간 처리한 군 (4~6군), 60초간 처리한 군 (7~9군)으로 나누고, 이를 다시 Clearfil SE Bond의 프라이머로 5초 (1, 4, 7군), 20초 (2, 5, 8군), 60초 (3, 6, 9군)간 처리한 군으로 분류하였다. 접착제 처리한 면에 Clearfil AP-X 복합레진을 접착하고 24시간 경과 후 전단응력 강도를 측정하였다. 결과는 One-way ANOVA 처리후 Duncan's multiple range test로 사후검증하였다. 동일한 자가산부식 프라이머 처리 시간을 가진 군에서 산 부식을 한 경우가 그렇지 않은 군에 비해 높은 접착강도를 나타내었으며 인산부식 시간의 차이에 의한 영향은 없었다.(1 < 4, 7군/ 2 < 5, 8군/ 3 < 6, 9군). 자가산부식제의 프라이머 적용 시간에 의한 효과는 1군(5초 적용)을 제외한 나머지 군의 경우 동일한 인산 처리군에서는 차이가 없는 것으로 나타났다.(1군 < 2, 3군/ 4=5=6군/ 7=8=9군). Clearfil SE Bond 접착제의 법랑질에 대한 접착강도는 부가적인 산부식을 통하여 증가시킬 수 있으며 프라이머의 적용 시간에 의한 효과는 제조자의 지시에 의한 시간 이상 적용할 경우 차이가 없는 것으로 나타났다.