• Title/Summary/Keyword: 2단 팽창

Search Result 65, Processing Time 0.024 seconds

Slaking, Swelling and Shear Strength Characteristics of Pohang Mudrocks (포항이암층의 Slaking, 팽창 및 전단강도특성)

  • 이영휘
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.33-42
    • /
    • 1996
  • The weathering of mudrock in the Pohang area is mainly caused by slaking and swelling when the mudrock is absorbed with water. In this regard, this paper chows the results of chemical analysis and the identification of rock-forming minerals from XRD. It also compares the slaking and swelling characteristics of mudrocks sampled from 3 different sites. The chief rock -forming minerals are the quartz, and the several types of clay minerals. The slake durability indices are ranged from 71% to 96%, and these values are closely related to the liquid limit of the powdered nock specimen. In a similar manner to the slaking characteristics the greatest values of the swelling pressure and the swelling strain were measured from the mudrock specimen with the highest value of liquid limit. The greatest measured values of the swelling pressure and the swelling strain are 9.4 kg 1 cm2 and 33.5% respectively. The residual sheer strength of mudrock decreases as the number of wet -diy cycles increases, and the residual strength at 5 cycles are measured to c,=0.24kg/cm2 and p,=28$^{\circ}$. The lowest residual strength is measured at the fresh rock -rock contact surface in the moist condition of which values are cr: 0 and n,: 21.5$^{\circ}$.

  • PDF

Analysis and Measurement of Residual Stress of Al 7175 Ring Rolls after Quenching and stress Relieving (고강도 알루미늄 7175 합금 링롤재의 급냉 및 응력제거처리후 잔류응력 유한요소해석 및 측정)

  • 박성한;구송회;이방업;은일상
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.1 no.1
    • /
    • pp.104-110
    • /
    • 1997
  • To predict the effect of ring expansion and ring compression on residual stress relief of Al 7175 ring rot]s, 2-D axisymmetric thermal analysis and elastoplastic analysis were performed. The residual stress distributions along the thickness of T73, T7351 and T7352 treated rings were measured using three step sectioning method. The measured results were compared to numerical ones for quenched and stress relieved rings. After quenching, calculated hoop and axial residual stresses were similar to measured ones for T73 treated rings. The residual stresses of T7351 and T7352 treated rings were decreased remarkably compared to T73 treated rings. The effect of axial residual stress relief was superior to that of hoop one, and also ring compression to ring expansion. It was concluded that ring compression is advantageous over ring expansion in view of stress relief effect and practicality, and vice versa in view of dimensional control and press power.

  • PDF

인공심장의 연구개발 현황

  • 한동철;천길정
    • Journal of the KSME
    • /
    • v.27 no.2
    • /
    • pp.99-108
    • /
    • 1987
  • 국내에서 개발중인 인공심장으로는 서울대학교 공과대학 기계설계학과와 서울대학교병원 의공학과에서 공동으로 개발중인 전기-기계식 인공심장이 있다. 모우터가 내장된 실린더가 모우터의 정.역전에 따라 통 안에서 좌.우로 움직이면서 좌.우심실을 교대로 압축한다. 모우터가 들어 있는 실린더의 위치가 통 안에서 고정되어 있지 않고 움직이므로, 한쪽 심실이 팽창할 때 실린더가 다른 한쪽 심실 공간을 차지하여 결국 전체 체적은 하나의 심실 공간과 모우터 공간만 있으면 되므로 모우터의 위치가 고정된 형식에 비해 체적 감소가 가능하다. 에너지 변환기를 구성하는 기계요소로는 2단의 유성기어열과 랙(rack)뿐으로서 비교적 구조가 간단하여 고장의 가능성이 낮다. 따라서 기존 모델들이 지니고 있는 단점들이 거의 극복 되었다. 현재 모의 순환실험에 성공하고 동물 실험을 준비 하고 있다.

  • PDF

THE CAUSTICS AROUND A LOCAL DENSITY PERTURBED REGION IN REDSHIFT SPACE AND THEIR IMPLICATIONS TO RICH CLUSTERS OF GALAXIES (적색편이 공간에서 국부 요동지역 주변의 초면과 은하단에 응용)

  • 송두종
    • Journal of Astronomy and Space Sciences
    • /
    • v.10 no.2
    • /
    • pp.163-188
    • /
    • 1993
  • On the framework of Tolman spacetime model, the caustics around a local perturbed region in redshift is due to the local expansion rate induced by a local density inhomogeneity in real space. We have compared the caustics in redshift space, which are analytically obtained, with the observed redshift-distance patterns of galaxies which are belonging to Coma and Perseus clusters. For the Abell density distribution model and polytropic density profiles which are well-fitting the optical and X-ray observations, respectively, the size of caustics which is defined by "turnaround radius" of a local density perturbed region should give constraints on the sizes and masses of rich clusters and give also a clue to understand the state of hot X-ray emitting gas.

  • PDF

Performance Analysis of Two-stage Compression and Two-stage Expansion Refrigeration System using Freon Refrigerants (친환경 프레온 냉매를 이용하는 단압축 단팽창 냉동시스템의 성능예측)

  • Roh, Geun-Sang;Kim, Jong-Ryeol
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.2
    • /
    • pp.301-306
    • /
    • 2013
  • In this paper, cycle performance analysis of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants is presented to offer the basic design data for the operating parameters of the system. Alternative freon refrigerant for freon refrigerant R22 were used as working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, and mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and two-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ratio of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants have an effect on COP of this system.

An Experimental Study on the Optimal Intermediate Pressure of a 2-Stage Compression Heat Pump Using River Water (하천수 열원 2단압축 열펌프의 최적 중간압에 관한 실험적 연구)

  • Park, Cha-Sik;Jung, Tae-Hun;Joo, Young-Ju;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.6
    • /
    • pp.333-339
    • /
    • 2009
  • The objective of this study is to predict optimal intermediate pressure of a 2-stage compression heat pump system using river water. To determine the maximum performance of the 2-stage compression heat pump system, the experimental evaluations on the 2-stage compression cycle were carried out under various operating conditions. Electronic expansion valves were applied to control intermediate pressure and superheat. Based on the experimental data, an empirical correlation for predicting optimal intermediate pressure which considering cycle operating parameters was developed. The present correlation was verified by comparing the predicted data with the measured data. The predictions showed a good agreement with the measured data within a relative deviation of ${\pm}4%$ at various operating conditions.

Simulation on the Optimal Performance and Effective Operating Range of a 2-Stage Compression Heat Pump Using River Water (하천수 열원 이용 2단압축 열펌프의 최적성능 및 효용 운전범위에 관한 시뮬레이션 연구)

  • Jung, Tae-Hun;Park, Cha-Sik;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.295-303
    • /
    • 2008
  • The objectives of this study are to predict actual system performance and effective operating range of the 2-stage compression heat pump system using river water. An electronic expansion valve was applied to the simulation to analyze the effects of operating conditions on the system performance. The developed program was verified by comparing the predictions with the measured data. The results from the present model showed a good agreement with the measured data. In addition, the heat pump simulation was conducted by increasing condenser reservoir inlet temperature to investigate the benefits of the 2-stage compression over the 1-stage compression in the heating mode. The performance of the 2-stage compression cycle was better than that of the 1-stage compression when the inlet temperature of the condenser reservoir was higher than $40^{\circ}C$.

Simulation on the Heating Performance of a 2-Stage Compression Heat Pump System Using River Water (하천수열원을 이용한 2단압축 열펌프의 난방성능 시뮬레이션)

  • Park Chasik;Kim Bohyun;Kim Yongchan;Lee Young Soo;Bang Ki-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1005-1013
    • /
    • 2005
  • The use of river water as a heat source of a heat pump has the advantage in the performance compared to the use of atmospheric air because the temperature variation of river water over the year is relatively small. In this study, the performance of the heat pump system using river water as a heat source was numerically investigated. A simulation model for the 2-stage compression heat pump system was developed with each component model composed of compressors, heat exchangers, a flash tank and electronic expansion devices. The peformance of the heat pump system using river water was improved by $50\%$ compared to that using atmospheric air in winter conditions.

A Simulation Study on the Cascade Refrigeration Cycle for the Liquefaction of the Natural Gas [2]: An Application to the Multistage Cascade Refrigeration Cycle (천연가스 액화를 위한 캐스케이드 냉동사이클의 전산모사에 대한 연구 [2]: 다단 캐스케이드 냉동 사이클에 적용)

  • Cho, Jung-Ho;Kim, Yu-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.1013-1019
    • /
    • 2011
  • In this paper, simulation works for a multi-stage cascade refrigeration cycle using propane, ethylene and methane as refrigerants have been performed for the liquefaction of natural gas using Peng-Robinson equation of state built-in PRO/II with PROVISION release 8.3. The natural gas feed compositions were supplied from Korea Gas Corporation and the flow rate was assumed to be 5.0 million tons per annual. Supply temperature for propane refrigerant was fixed as $-40^{\circ}C$, that for ethylene refrigerant as $-95^{\circ}C$, and that for methane refrigerant as $-155^{\circ}C$. For the multi-stage refrigeration cycle, three-stage refrigeration was assumed for propane refrigeration cycle, two-stage refrigeration for ethylene refrigeration cycle and three-stage refrigeration for methane refrigeration cycle. Natural gas was finally cooled and liquefied to $-162^{\circ}C$ by Joule-Thomson expansion. Conclusively, 91.71% by mole of the natural gas liquefaction ratio was obtained through a cascade refrigeration cycle and Joule-Thomson expansion and 0.433 kW of compression power was consumed for the liquefaction of 1.0 kg/hr of natural gas.

Simulation Study on the Performance Improvement of a Transcritical Carbon Dioxide Cycle (초월임계 이산화탄소 사이클의 성능향상에 관한 시뮬레이션 연구)

  • 조홍현;김용찬;서국정
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.158-166
    • /
    • 2004
  • The performance of a heat pump using $CO_2$ is predicted and analyzed by using a cycle simulation model developed in this study. Cycle simulations are conducted by varying design parameters and operating conditions with the applications of advanced techniques to improve system performance. The applied systems in the simulations are internal heat exchanger, expander, and 2-stage compression with intercooling. As a result, the applications of advanced techniques improve the heating and cooling performances of the transcritical $CO_2$ cycle by 8∼26% and 20∼30%, respectively, over the basic cycle.