• 제목/요약/키워드: 2단압축

검색결과 285건 처리시간 0.027초

하천수 열원 이용 2단압축 열펌프의 최적성능 및 효용 운전범위에 관한 시뮬레이션 연구 (Simulation on the Optimal Performance and Effective Operating Range of a 2-Stage Compression Heat Pump Using River Water)

  • 정태훈;박차식;김용찬
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.295-303
    • /
    • 2008
  • The objectives of this study are to predict actual system performance and effective operating range of the 2-stage compression heat pump system using river water. An electronic expansion valve was applied to the simulation to analyze the effects of operating conditions on the system performance. The developed program was verified by comparing the predictions with the measured data. The results from the present model showed a good agreement with the measured data. In addition, the heat pump simulation was conducted by increasing condenser reservoir inlet temperature to investigate the benefits of the 2-stage compression over the 1-stage compression in the heating mode. The performance of the 2-stage compression cycle was better than that of the 1-stage compression when the inlet temperature of the condenser reservoir was higher than $40^{\circ}C$.

2단압축 상분리 사이클을 적용한 이산화탄소 시스템의 성능향상에 관한 해석적 연구 (Simulation Study on the Performance Improvement of a $CO_2$ System Applying a Two-stage Phase-separate Cycle)

  • 류창기;이호성;김용찬;조흥현;조성욱
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.641-648
    • /
    • 2006
  • In this study, a two-stage phase-separate cycle was investigated analytically to improve the performance of the $CO_2$ system in the cooling mode. The simulation results were verified with the measured data. The predictions using the simulation model were consistent with the measured data within ${\pm}20%$ deviations. The performance of the modified $CO_2$ system with the two-stage phase-separated cycle was analyzed with the variations of outdoor temperature and EEV opening. The cooling COP decreased with the increase of compressor frequency. The highest COP was 2.7 at compressor frequencies of 30 Hz and 30 Hz for the first and second compressors, respectively. In addition, the cooling COP increased by 9.3% with an application of optimum control of the first and second-stage EEV openings.

16Kbps와 40Kbps의 Dual Rate G.726 ADPCM 음성 codec구현 (Implementation of G.726 ADPCM Dual Rate Speech Codec of 16Kbps and 40Kbps)

  • 김재오;한경오
    • 전기전자학회논문지
    • /
    • 제2권2호
    • /
    • pp.233-238
    • /
    • 1998
  • 본 논문에서는 G.726 ADPCM 음성방식을 기존의 단일 압축을 대신 16Kbps 와 40Kbps의 두 가지 압축율을 사용한 가변 압축방식에 의한 음성 코딩 방식을 다루었다. 음성의 묵음 또는 소 신호 부분은 음질의 향상보다는 데이터 비트 수를 줄이기 위한 저 전송 16Kbps 압축율을 적용하였고 임계값 이상의 대 신호 부분은 음질을 향상하기 위하여 40Kbps의 압축율을 적용하여 모든 신호를 단일 압축율로 코팅하는 방식에 비하여 전체적으로 압축율을 높여 전송 비트 수를 줄이면서 음질을 저하시키지 않도록 하였다. 분 논문에서는 시뮬레이션을 통하여 여러 가지의 임계값에 의한 가변 압축 코딩 방식에 대하여 압축율과 음질의 관계 를 다루었다. 또한 고정된 임계값에 대하여 입력 음성의 크기를 여러 가지로 변동하여 주변 배경잡음과 포화에 의한 음질의 저하를 고찰하여 가변 율에 의한 음성의 코딩방식에서 임계값과 입력의 크기가 음질 및 압축율에 미치는 영향을 다루었다. 각 시뮬레이션의 경우에 대하여 실지 음성의 원음에 대한 음질의 충실 도를 임의의 집단에 대하여 비교하여 음질의 충실 도를 확인하였다. 추후의 연구를 통하여 DSP에 의한 실시간 처리 시스템의 구현을 하고자 한다.

  • PDF

휨재의 인성개선에 관한 연구 (Studies on Improvement of Ductility of Flexural Members)

  • 정일영
    • 콘크리트학회지
    • /
    • 제5권3호
    • /
    • pp.125-132
    • /
    • 1993
  • 콘크리트의 인성개선을 위하여 횡보강근을 사용할 수 있으나 보통강도으 철근ㅇ르 사용하였을 경우에는 조속한 철근의 강상으로 인한 콘크리트으 인성개선효과가 급격히 떨어지기 때문에 고강도 횡보강도에 의한 압축인성 개선효과를 이론 및 실험으로 고찰하였다. 실험결과 각 공시체의 변형능력을 비교해 보면 보통강도근의 경우 콘크리트 응력블록계수가 최대일 때 콘크리트의 압축단 변형도가 1%내외인데 비하여 고강도근으로 횡보강하였을 경우가 콘크리트의 압축변형도는 2%로서 충분한 휨압축 인성개선용으로 콘크리트의 충분한 인성개선이 가능하다고 볼 수 있다.

EES를 이용한 대체냉매 작동 2단압축냉동사이클의 성능해석 (Two-Stage compression cycle operating with alternative refrigerant using by EES program)

  • 박천완;이동규;최승길;강채동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.533-538
    • /
    • 2009
  • The present study has been conducted to an analysis of two stage refrigeration cycle with alternative refrigerant R410A. In the analysis, single stage cycle (R22 and R410A) compared to COP changing with supercooling degree. Secondly, two stage refrigeration cycle is investigated to the existence of intercooler or supercooler. At results, supercooler contributes to the increase of cooling capacity and the decrease of COP.

  • PDF

$CO_2$용 2단압축 1단팽창 냉동 사이클의 성능 분석 (Performance Analysis of a Carbon Dioxide(R744) Two-Stage Compression and One-Stage Expansion Refrigeration Cycle)

  • 노건상;손창효
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.70-75
    • /
    • 2009
  • In this paper, cycle performance analysis of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature in the carbon dioxide two-stage refrigeration cycle. The main results were summarized as follows : The cooling capacity of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, compressor efficiency and gas cooling pressure, but decreases with the increasing mass flowrate ratio and evaporating temperature. The compression work of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, outlet temperature of gas cooler, gas cooling pressure and evaporating temperature, but decreases with the increasing compressor efficiency and mass flowrate ratio. The COP of two-stage compression and one-stage expansion refrigeration system increases with the increasing compressor efficiency, but decreases with the increasing superheating degree, gas cooling pressure, mass flowrate ratio and evaporating temperature. Therefore, superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system have an effect on the cooling capacity, compressor work and COP of this system.

  • PDF

X-대역 펄스압축 Solid State Radar를 위한 200W SSPA 개발 (Implementation of the 200-Watts SSPA for X-band Pulse Compression Solid State Radar)

  • 김민수;이춘성;이상록;이영철
    • 대한전자공학회논문지TC
    • /
    • 제46권12호
    • /
    • pp.22-29
    • /
    • 2009
  • 본 논문에서는 X-대역 펄스압축 반도체형 레이다를 위한 200W SSPA를 개발하였다. 개발한 X-대역 SSPA는 전치증폭단, 구동증폭단, 고출력을 위한 주전력 증폭단의 3단 연계구조형 증폭기로 구성되어있다. X-대역에서 200W 이상의 출력을 내기 위해 주전력 증폭단은 충분한 이득과 전력을 얻을 수 있는 GaN HEMT소자를 사용하여 병렬구조로 설계하였다. 개발한 SSPA는 주파수범위 9.2-9.6GHz, 펄스주기 1ms, 펄스폭 100us, 듀티사이클 10% 조건에서 전체이득 59dB 이상, 출력전력 200W이상의 성능을 가진다. 본 논문에서 개발한 SSPA는 펄스압축기술을 이용한 고품위 반도체 레이다시스템에 적용할 수 있다.

다기능 표층용 아스팔트 혼합물의 역학적 특성 평가 (Evaluation on the Mechanical Properties of Multi-Functional Asphalt Pavements for Surface Course)

  • 이관호;함상민;김성겸;이병식
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 1부
    • /
    • pp.292-295
    • /
    • 2011
  • 본 논문에서는 배수성(저소음)포장을 포함하는 2-Layer 아스팔트 포장의 상부층과 하부층의 역학적인 특성을 평가하는데 목적이 있다. 연구 방법으로는 슈퍼페이브 배합설계로 2-Layer 아스팔트 포장의 상 하부층 시편을 제작하였으며, 시편 상부층의 최대공칭치수는 4.75mm이고 하부층의 최대공칭치수는 13mm이다. 이 시편에 대한 기본 물성 시험 실시 후 마샬 안정도 시험에 대한 안정도와 흐름값을 평가하였다. 그리고 상부층과 하부층의 자유단 공진주 시험을 통해 탄성계수(E)를 측정하였고, 비파괴 시험법인 슈미트해머(Schmidt hammer)를 이용해 반발경도를 측정한 후 강도를 추정하였다. 또한 일축압축시험으로 측정된 압축강도로 탄성계수($E_{50}$)를 계산하였다. 마지막으로 각각의 역학적 시험을 통해 얻어진 결과값으로 강도(qu)와 탄성계수 ($E_{50}$)의 상관관계와 추정식으로 구한 강도와 일축압축강도 시험으로 얻어진 강도와의 상관관계를 분석하였고, 자유단 공진주 시험의 탄성계수(E)값과 일축압축시험의 결과로 얻어진 탄성계수($E_{50}$)의 상관관계를 분석하였다.

  • PDF