• Title/Summary/Keyword: 1st Frequency

Search Result 943, Processing Time 0.032 seconds

하거허 상응부위 저주파 전침자극이 흰쥐의 장운동에 미치는 영향 (The Effect of Low Frequency Electro-acupuncture at ST39 on Intestinal Motility in Rats)

  • 홍서진;이현;강재희
    • Journal of Acupuncture Research
    • /
    • 제33권1호
    • /
    • pp.9-21
    • /
    • 2016
  • Objectives : The aim of this study was to investigate the effect of low frequency electro-acupuncture at ST39 on intestinal motility in rats. Methods : Intestinal hypermotility and hypomotility in rats were induced by oral carbachol ingestion and loperamide injection. Rats were divided into seventeen experimental groups including the normal and holder groups. The rats were induced with intestinal hypermotility and hypomotility and divided into pre and post-treatment groups. I also carried out acupuncture (needle retention) and low frequency electro-acupuncture at ST39 or the sham point. I fed charcoal to rats after the treatment and calculated its distance travelled in the gastrointestinal tract, which was compared by groups so as to determine which treatment was more effective in increasing or decreasing intestinal motility. Results : 1. In normal rats, low frequency electro-acupuncture at ST39 showed no significant effect on intestinal motility. 2. Pre-treatment with acupuncture (needle retention) at ST39 on intestinal motility over-activated with carbachol significantly decreased intestinal motility in rats. 3. Pre-treatment with low frequency electro-acupuncture at ST39 on intestinal motility over-activated with carbachol significantly decreased intestinal motility in rats. 4. Pre-treatment with acupuncture (needle retention and low frequency electro-acupuncture) at ST39 showed no significant effect on intestinal hypomotility in rats that was induced by loperamide injection. Conclusions : These results suggest that acupuncture (needle retention) and low frequency electro-acupuncture at ST39 have preventive effects on intestinal hypermotility. Regardless of the stimulation method, ST39 showed an effect on intestinal motility. Further study is required to confirm other effects of ST39.

해계(解谿)(ST41) 유침 및 전침의 전.후처치가 loperamide로 억제된 흰쥐의 장운동에 미치는 영향 (The Effect of Acupuncture and Electro-acupuncture at ST41 on Experimentally-induced Intestinal Hypo-motility in Rats: Comparison between Pre-treatment and Post-treatment)

  • 김경민;이현;임윤경
    • 대한한의학회지
    • /
    • 제33권3호
    • /
    • pp.20-32
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the effect of acupuncture and electro-acupuncture (EA) of low and high frequencies at Haegye (ST41) in rats. Methods: The intestinal motility of rats was experimentally suppressed with loperamide. Acupuncture, low frequency EA and high frequency EA were carried out before the loperamide administration in the pre-treatment group, and after the loperamide administration in the post-treatment group. The rats were fed charcoal and the travel rate of charcoal in the gastrointestinal track was measured to analyze the effect of acupuncture, low frequency EA and high frequency EA on the intestinal hypo-motility. Results: 1. None of acupuncture, low frequency EA or high frequency EA at ST41 showed significant influences on intestinal motility of rats in normal status. 2. Pre-treatment with acupuncture at ST41 showed no significant effect on the intestinal hypo-motility induced by loperamide in rats. 3. Pre-treatment with low frequency EA and high frequency EA at ST41 significantly reduced the suppression of intestinal motility by loperamide in rats. 4. Post-treatment of acupuncture, low frequency EA and high frequency EA at ST41 had no significant influences on the intestinal hypo-motility induced by loperamide in rats. Conclusions: These results suggest that low and high frequency EA at ST41 may be effective to prevent gastric disorders such as intestinal hypo-motility.

洛東江 下流城 濫藻 Anabaena의 個體群 變動 및 毒性 硏究 (Population Dynamics and the Toxin of Anabaena in the Lower Naktong River)

  • Choi, Ae-Ran;Park, Jin-Hong;Lee, Jin-Ae
    • ALGAE
    • /
    • 제17권2호
    • /
    • pp.95-104
    • /
    • 2002
  • Population dynamics of Anabaena and the anatoxin-a concentration were monitored with physicochemical parameters at 3 sites in the lower Naktong River from May to September in 2000. Total 4 species of Anabaena (A. flosaquae, A. smithii, A. ucrainica and A. mucosa) were identified with morphological characterisitcs. Anabaena flos-aquae was most abundant among the populations. The standing crop of Anabaena ranged from 10 to 11,220 cells · $ml^{-1}$ and biomass of Anabaena more 1,000 cells · $ml^{-1}$ was obseved once at St. Mulgeum and St. Seonam, twice at St. Hagueon out of total 9 samplings. There were not significant correlations between the standing crop of Anabaena and other physicochemical parameters such as temperature, nitrate, total nitrogen, phosphate, total phophorus and N/P ratios. The frequency of trichomes with akinetes was low and ranged from 0 to 4% in the total Anabaena population and A. smithii showed highest frequency of 2.8% among all species. The population at St. Seonam showed highest frequency of 1.4% among all sampling sties. The population in September showed the highest frequency of 3.0% among all sampling period. The frequency of trichomes with heterocysts was low and ranged from 1 to 87% inthe total Anabaena population and A. smithii showed highest frequency of 55.1% among all species. The population at St. Mulgeum showed highest frequency of 17.6% among all sampling sites. The population in August showed the highest frequency of 21.4% among all sampling period. The frequency of trichomes with akinetes and/or heterocysts was not related to all the physicochemical parameters of temperature, nitrate, total nitrogen, phosphate, total phosphorus and N/P ratios. The anatoxin-a concentations were determined in algal materials dominated by Microcystis and Anabaena from June though August by derivatization using 7-fluoro-4-nitro-2, 1,3-benzoxadiazole (NBD-F) and HPLC analysis with fluorimetric detection. All the concentrations were below the detection limit of 0.1 ㎍ · $l^{-1}$ in the present study.

해계 유침 및 전침의 전.후 처치가 실험적으로 항진된 흰쥐의 장운동에 미치는 영향 (The Effect of Acupuncture and Electro-acupuncture of Low and High Frequencies at $ST_{41}$ on Experimentally Induced Intestinal Hypermotility in Rats: Comparison between Pre-treatment and Post-treatment)

  • 최주영;이현
    • Journal of Acupuncture Research
    • /
    • 제27권3호
    • /
    • pp.117-126
    • /
    • 2010
  • Objectives : The purpose of this study was to compare the effect of needle retention(NR) and electro-acupuncture of low(EA(L)) and high(EA(H)) frequencies at Haegye($ST_{41}$) on intestinal hypermotility induced with carbachol in rats Methods : We made over-activated state of intestinal motility with carbachol in rats and caried out needle retention acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture at Haegye($ST_{41}$) or sham point in rat devided into pre-treatment group and post-treatment group. And we resulted as followings from measuring charcoal travel rate with observation of intestinal motility. Results : 1. None of acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture at $ST_{41}$ had significant influences on intestinal motility of rat in normal state. 2. Pre-treated with acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture and post-treated with acupuncture and low frequency electro-acupuncture at $ST_{41}$ didn't significantly influences intestinal motility in rat which over-activated with carbachol. 3. Post-treated with high frequency electro-acupuncture at $ST_{41}$ suppressed intestinal motility in rat which over-activated with carbachol. Conclusions : These results suggest that treatment high frequency electro-acupuncture at ST41 may be effective on gastric disorders such as intestinal hypermotility and its effect had more cure than prevention.

위상잡음 특성을 개선한 주파수 변환 모듈의 설계 및 제작 (Design and Implement of the Frequency-Shifting Module for the Improvement of Phase Noise Performance)

  • 변종대;하태웅;김진수;박준석;임재봉
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.273-278
    • /
    • 2004
  • This paper analyzed the phase noise characteristics of frequency-shifting module by figuring out the relationship between the phase noise components of 1st and 2nd local oscillator composing the frequency-shifting module and those of RF output signals shifted in frequency. Also, frequency-shifting module with the improvement of the phase noise performance was designed and implemented by means that the phase noise components of 1st local oscillator were cancelled in the output signal. Output signal has been affected by only phase noise of 2nd local oscillator, which had excellent phase noise performance than that of the 1st local oscillator.

족삼리(足三里) 침자(鍼刺)가 위운동(胃運動)에 미치는 영향(影響)에 관한 신경학적(神經學的) 관찰(觀察) (Neurologic Study of Acupuncture ST36(足三里) on Gastric Motility in Rats)

  • 황우준;류인식
    • Journal of Acupuncture Research
    • /
    • 제17권1호
    • /
    • pp.119-127
    • /
    • 2000
  • To investigate the acupuncturing function of $ST_{36}$(足三里) on the gastric activity, four different treatment methods such as intact, local anesthesia, ligation and nerve dissection were implemented. Followings are the results from the present study. 1. When a simple acupuncture with intact, the stomach motility and frequency were increased without significance compared with control. 2. Under local anesthesia on femoral region, the stomach motility and frequency showed no such changes compared with control. 3. With ligation of femoral region, the stomach motility and frequency were decreased significantly compared with control. 4. When the siatic nerve was dissected, the stomach motility and frequency showed no such changes compared with control. Overall, the effect of acupuncture on the $ST_{36}$(足三里) was very closely related with the condition of surrounding area. It is assumed that further studies should be done for the investigation of mechanism behind the acupuncturing function in conjunction with the nervous system.

  • PDF

복합재 철도차량 차체 고유진동수에 대한 해석 및 시험적 연구 (Analytical and Experimental Studies on the Natural Frequency of a Composite Train Carbody)

  • 정종철;조세현;서승일;김정석
    • 대한기계학회논문집A
    • /
    • 제30권4호
    • /
    • pp.473-480
    • /
    • 2006
  • This paper explains analytical and experimental studies to evaluate the natural frequency of a composite carbody of Korean tilting train. The composite carbody with length of 23m was manufactured as a sandwich structure composed of 40mm-thick aluminium honeycomb core and 5mm-thick woven fabric carbon/epoxy face. From the finite element analysis, the 1st bending and 1st twisting natural frequency of the composite carbody were 11.67Hz and 14.4Hz, respectively. In order to verify the analytical results, the natural frequency measuring tests were performed. The measured 1st bending and twisting natural frequencies of the composite carbody were 10.25Hz and 11.0Hz, respectively. Both of these results satisfied the design requirement.

열에이징에 의한 PZT세라믹스의 내열특성 개선 (Improving Thermal Resisting Property of PZT Ceramics by Thermal Aging)

  • 이개명;김병효
    • 한국전기전자재료학회논문지
    • /
    • 제18권1호
    • /
    • pp.43-49
    • /
    • 2005
  • Temperature stabilities of resonance frequencies of the substrates are very important in piezoelectric ceramics oscillators and fitters. In this study, it was investigated thermal resisting property of the length-extensional vibration mode of PZT ceramics. The mode can be utilized in fabricating ultra-small 55 kHz IF devices. We fabricated the ceramic specimens with x = 0.51, 0.52, 0.53, 0.54, and 0.55 in the Pb(Zr$\sub$x/Ti$\sub$1-x/)O$_3$ system. And their resonance frequencies were measured before 1st thermal aging, after 1st and 2nd thermal aging. In order to investigate the influence of thermal aging on thermal resisting properties, thermally aged specimens were once mote thermally aged. Before 1st thermal aging, the specimens of the compositions with morphotropic phase, x = 0.53 and rhombohedral phase, x = 0.54 have weak thermal resisting property of resonance frequency, while tetragonal phase, x = 0.51 has robust thermal resisting property of resonance frequency. 1st thermal aging improved thermal resisting property of resonance frequency in all specimens.

Parallel Coupled SIR을 이용한 이중대역 통과필터 설계 연구 (Design of Dual-Band Pass Filter Using Parallel Coupled SIR)

  • 김군태;백현;김형석
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.215-218
    • /
    • 2009
  • In this paper, Dual-band bandpass filter studied design using Parallel Coupled SIR(Stepped Impedance Resonator). This Dual-band bandpass filter design SIR of half-wavelength by Parallel-coupled type that is available to RFID system and Changed structure in Meander form by size reduce. Because seen Dual-band bandpass filter is designed so that is applicable for frequency 433MHz and 2.45GHz of RFID system is very wide distance between two pass-band, establish 433MHz by fundamental frequency and controlled 2.45GHz by 2st spurious resonance frequency bandstop filter of 1st spurious resonance frequency and Parallel coupled SIR Combine to remove 1st spurious resonance frequency.

  • PDF

한국 성인의 하악대구치 임상치관의 형태와 크기에 관한 연구 (A STUDY ON MORPHOLOGY AND SIZE OF CLINICAL CROWN OF PERMANENT MANDIBULAR MOLAR IN KOREAN ADULT)

  • 오상천
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.242-255
    • /
    • 1999
  • The purpose of this study was to estimate the morphology and the size of permanent mandibular molar in Korean Adult. The 100 dental college students with a normal dentition and without any dental prosthesis and severe caries were selected for this study The subjects were taken impression to make study model. On the study model, the 5 dentists measured those sizes and estimated morphological structures with a calipers, a Boley gauge and a protractor. The results were as follows; 1. The clinical crown height, width, thickness and the other anatomical structures had symmetrical relationship between the left and right mandibular molar. 2. In the clinical crown height aspect, the buccal crown heights always were higher than the lingual crown height. The heights of the each surface, the buccal or lingual surface, were gradually decreased from the 1st molar to the 2nd molar and the difference on the buccal surface was higher than that on the lingual surface. 3. In the clinical crown width aspect, the mesiodistal measurement of the mandibular 1st molar was higher than that of the mandibular 2st molar. 4. In the clinical crown thickness aspect, the mesial buccolingual measurement was highest on the mandibular 1st molar and the distal buccolingual distance was lowest on the mandibular 2nd molar. This distal thickness of the mandibular molar always was higher than that of the mesial half. 5. The well-developed mesiobuccal groove of the 1st molar was observed more often than that of the 2nd molar. The buccal pit was also observed more frequently at the 1st molar, but the frequency(35%) was not high. 6. The occlusal type according to the number of cusp was almost 5-cusp(98%) in the 1st molar and was also 5-cusp(63%) in the 2nd molar. The frequency of the 6th cusp was 31% in the 1st molar and was 22% in the 2nd molar. The frequency of the 7th cusp was below 2of in the both teeth. 7. In the buccolingual intercuspal distance aspect of the mesial and distal half, the intercuspal distance of distal half was higher than that of the mesial half on the 1st and 2nd molar, but the difference on the 1st molar was higher than that on the 2nd molar. 8. The difference between the widths of the buccal and lingual half was 1.5mm in the 1st molar and 0.8mm in the 2nd molar. Therefore the lingual convergency of the occlusal surface was more higher in the 1st molar. 9. On the mandibular 1st and 2nd molar, the distobuccal external angle was more acute than the mesiobuccal external angle. But the mesiobuccal internal angle was more acute than the distobuccal internal angle. 10. When the mandibular molar was a 5-cusp type, the development of the distal cusp on the 1st molar was better than that on the 2nd molar. The difference between the cusps was around 0.4mm.

  • PDF