• Title/Summary/Keyword: 1st Frequency

Search Result 943, Processing Time 0.03 seconds

The Effect of Stage diffusers on the Stage Acoustics in a Concert Hall (콘서트홀에서 무대음향에 대한 확산체의 영향)

  • Lee Chung-Hwa;Jeon Jin-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.171-177
    • /
    • 2005
  • The effect of diffusers on Early Stage Support (ST1) in a concert hall was investigated at 8 positions in a 1:25 stage scale model. Experiments were carried out when the stage floor was covered with and without absorption cloth to investigate the effect of stage floor reflection (absorption coefficient - 0.6 at 500Hz). To find out the effect of stage wall. three types of wall diffusers were used. As a result. absorption cloth on stage floor reduced the ST1 values at high frequency. but the average value of ST1 was not changed. Three types of stage wall diffusers were revealed as unaffecting. but it was observed that the ST1 values varied to positions of stage. The ST1 values were evenly distributed when hemisphere diffusers were used. Therefore. the use of floor absorption did not have much effect on the ST1 values, and the diffusers had some effect on the distribution of the ST1 values.

Vibration Analysis of Micro Speaker Diaphragm (마이크로 스피커 다이어프램의 진동해석)

  • Hong, D.K.;Woo, B.C.;Ahn, C.W.;Han, G.J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.551-554
    • /
    • 2005
  • This study uses a characteristic function to explain correlations between the objective function and design variables. Analysis of means and table of orthogonal array were carried out. The change of shape of diaphragm, thickness of diaphragm and voice coil weight based on the table of orthogonal array is made. Therefore this study carried to decide shape of diaphragm, voice coil weight and thickness of diaphragm for minimizing 1st natural frequency and maximizing 2nd natural frequency of diaphragm using design of experiments and characteristic function with constraints. we showed improved design factors that minimized 1st natural frequency and maximized 2nd natural frequency of diaphragm.

  • PDF

A study on Inductance calculation in Interior Permanent Magnet Synchronous Motor (IPMSM의 인덕턴스 산정에 관한 연구)

  • Lee, Jin-Gyu;Kwon, Soon-O;Sun, Tao;Kim, Hae-Joong;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.880_881
    • /
    • 2009
  • This paper improves the calculating method about the inductance with the high order frequency coreloss. It is different in which the analyzed inductance for calculating IPMSM and the measured thing for experiment. Due to this phenomenon, the expected input voltage differs from the inquired input voltage for operating the motor. This results from the coreloss margin which have both the 1st order and high order frequency value. For reducing the inductance error, after calculating the equivalence coreloss resistance with having the 1st order frequency Back_EMF and coreloss, designing the inductance with the high order frequency which occurred by the coreloss of high order frequency, and comparing the renovated inductance analysis value with the measured thing.

  • PDF

Effect of Low Frequency Electroacupuncture on Nicotidamide Adenine Dinucleotide Phosphate-diaphorase(NADPH-d) Positive Neurons in the Brain Cortex of Rat with Adjuvant Induced Rheumatoid Arthritis (저빈도 전침자극이 류마토이드 관절염 유발 흰쥐 대뇌피질 Nicotidamide Adenine Dinucleotide Phosphate-diaphorase(NADPH-d) 양성세포 발현에 미치는 영향)

  • Jung, Ki-Hoon;Roh, Jeong-Du;Kim, E-Hwa;Lee, Eun-Yong
    • Journal of Acupuncture Research
    • /
    • v.25 no.3
    • /
    • pp.179-187
    • /
    • 2008
  • Objectives & Methods : This study was to investigate effect of low frequency electroacupuncture on NADPH-d positive neurons in the brain cortex of rat with adjuvant induced rheumatoid arthritis. Experimental groups were divided into 6 groups ; Normal, Control, $ST_{36}$, $SP_9$, $ST_{36}+SP_9$ and Non-Acupoint. Normal group, non-arthritic group, was injected normal saline, and the other groups were injected FCA. Each acupoint groups were treated by 2Hz electroacupuncture at each acupoints and NA group was treated by 2Hz electroacupuncture at non-acupoint. Each groups were evaluated by the number of NADPH-d positive neurons in primary somatosensory area(S1), secondary somatosensory area(S2), motor area and caudate putamen by using an image analyzer and a microscope. Results : 1. In S1, the number of NADPH-d positive neuron cells in the $ST_{36}$ group were significantly(p<0.05) increased compared with the control group. 2. In S2, the number of NADPH-d positive neuron cells in all electroacupuncture groups were not significantly changed compared with the control group. 3. In motor area, the number of NADPH-d positive neuron cells in $ST_{36}$ group, $SP_9$ group, NA group were significantly(p<0.05) increased compared with the control group. 4. In Caudate putamen, the number NADPH-d positive neuron cells in all electroacupuncture groups were significantly(p<0.05) decreased compared with the control group. Conclusions : Our result demonstrated that low frequency electroacupuncture on $ST_{36}$ & $SP_9$ normalized expression of NADPH-d positive neurons in the brain cortex of the rheumatoid arthritis model in rats.

  • PDF

Baseline heart rate variability in children and adolescents with vasovagal syncope

  • Shim, Sun Hee;Park, Sun-Young;Moon, Se Na;Oh, Jin Hee;Lee, Jae Young;Kim, Hyun Hee;Han, Ji Whan;Lee, Soon Ju
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.4
    • /
    • pp.193-198
    • /
    • 2014
  • Purpose: This study aimed to evaluate the autonomic imbalance in syncope by comparing the baseline heart rate variability (HRV) between healthy children and those with vasovagal syncope. Methods: To characterize the autonomic profile in children experiencing vasovagal syncope, we evaluated the HRV of 23 patients aged 7-18 years and 20 healthy children. These children were divided into preadolescent (<12 years) and adolescent groups. The following time-domain indices were calculated: root mean square of the successive differences (RMSSD); standard deviation of all average R-R intervals (SDNN); and frequency domain indices including high frequency (HF), low frequency (LF), normalized high frequency, normalized low frequency, and low frequency to high frequency ratio (LF/HF). Results: HRV values were significantly different between healthy children and those with syncope. Student t test indicated significantly higher SNDD values (60.46 ms vs. 37.42 ms, P =0.003) and RMSSD (57.90 ms vs. 26.92 ms, P=0.000) in the patient group than in the control group. In the patient group, RMSSD (80.41 ms vs. 45.89 ms, P =0.015) and normalized HF (61.18 ms vs. 43.19 ms, P =0.022) were significantly higher in adolescents, whereas normalized LF (38.81 ms vs. 56.76 ms, P =0.022) and LF/HF ratio (0.76 vs. 1.89, P =0.041) were significantly lower in adolescents. In contrast, the control group did not have significant differences in HRV values between adolescents and preadolescents. Conclusion: The results of this study indicated that children with syncope had a decreased sympathetic tone and increased vagal tone compared to healthy children. Additionally, more severe autonomic imbalances possibly occur in adolescents than in preadolescents.

Effects of Gonadotropin-Releasing Hormone on Reproductive Performance of Early Postpartum Dairy Cows and Cystic Cows (Gonadotropin-Releasing Hormone의 투여(投與)가 산욕기(産褥期)의 유우(乳牛)와 난소낭종유우(卵巢囊腫乳牛)의 번식효율(繁殖效率)에 미치는 영향(影響))

  • Hwang, Woo Suk
    • Korean Journal of Veterinary Research
    • /
    • v.21 no.1
    • /
    • pp.59-64
    • /
    • 1981
  • Holstein-Friesian cows(n=284) were given $100{\mu}g$ of gonadotropin-releasing hormone(GnRH) or saline solution by intramuscular injection at 10 to 22 days after parturition, and were investigated their reproductive performance and frequency of ovarian cysts. Among them 28 cystic cows were injected with $150{\mu}g$ of GnRH intramuscularly and examined the recovery rate. The results obtained in this study were summarized as follows: 1. The interval from calving to 1st ovulation was reduced from 28.2 days in controls to 16.5 days for cows given GnRH (p<0.01). 2. The intervals from calving to 1st estrus and from calving to conception were extended significantly in control group (p<0.05). 3. Inseminations per conception and conception rate at 1st insemination did not reveal difference between two groups. 4. Frequency of ovarian cysts was reduced from 14.0% in control to 4.20% for cows given GnRH (p<0.05). 5. Of the 28 cystic cows receiving $150{\mu}g$ of GnRH, 23(82.1%) responded to 1st treatment and returned to estrus $24.2{\pm}4.3$ days after treatment. 6. These data provide evidence for reduction in infertility and reproductive disorders in early postpartum dairy cows given GnRH as a prophylactic.

  • PDF

On the Performance of the Anti-Rolling Tank(1) (감요수조(減搖水槽)의 성능(性能)에 관(關)하여(1))

  • Bong-Koo,Woo;Jong-Do,Koo
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.8 no.2
    • /
    • pp.35-44
    • /
    • 1971
  • In terms of this paper, concerning primarily with the U-tube tank stabilizer, the authors' aim is to clarify and consolidate the theory as it has been developed thus far, and to provide with the certain additions which will make it more complete, more accurate, and more practical. And then we can know that the effect of the vertical tank position from the C.G., $a_{st}=1-w^2/{w^2}_{st}$, is very important, on account for the fact that the position factor, $a_{st}$, increase when the anti-rolling tank attaches to higher position vertically, but $a_{st}$ does not increase in proportion to the distance of the tank position. Measuring many characteristic coefficients by experiment, in the equation of the ship-tank system motion, such as the inertia coefficient, the damping coefficient, the natural frequency and so on, they can also give a guess that the higher position will accompany the non-linear motion of the tank water, but the non-linear effect will decrease the tank ability. In this study, they deal with not only the optimum damping coefficient of tank, which has very simply been expressed by the strength ratio, $\lambda$, but also the effect of the tank top, which has experimentally been treated when the water has hit the tank top. As this result, we can immediately find that the ability of the anti-rolling tank decrease at w/ws=0.9 generally low frequency.

  • PDF

Fabrication and Characteristics Comparison of Piezoresistive Four Beam Silicon Accelerometer Based on Beam Location (빔 위치변화에 따른 4빔 압저항형 실리콘 가속도 센서의 제조 및 특성비교)

  • Shin, Hyun-Ok;Son, Seung-Hyun;Choi, Sie-Young
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.26-33
    • /
    • 1999
  • In order to examine the effect of beam location n the performance of bridge type piozoresistive silicon accelerometer, three sensors having different location of beams were simulated by FEN(finite element method) and fabricated by RIE(reactive ion etching) and KOH etching method using SDB(silicon direct bonding) wafer, Results of the FEM simulation present that the 1st resonace frequency and Z axis sensitivity of each sensor are identical but the 2nd, and the 3rd resonace frequency and X, Y axis sensitivity are different. Even though the 1st resonance frequency and Z axis sensitivity measured from fabricated sensors do not perfectly coincide with each other, all 3 type sensors present 180 ~ 220N/G of Z sensitivity at 5 V supply voltage and 1.3 ~ 1.7kHz of the 1st resonance frequency and about 2% of lateral sensitivity.

  • PDF

The design of XYZ 3-axis stage for AFM system (AFM 시스템을 위한 XYZ 3축 스테이지의 설계)

  • 김동민;김기현;심종엽;권대갑;엄천일
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.36-36
    • /
    • 2002
  • To Establish of standard technique of length measurent in 2D plane, we develope AFM system. The XY scanner scans the sample only in XY plane, while the Z scanner scans the specimen only in Z-direction. Cantilever tip is controlled to has constant height relative to speciman surface by feedback of PSPD signal. To acquire high accuracy, Z-axis measuring sensor will be added.(COXI or others). In this paper we design XYZ stage suitable for this AEM system. For XY stage, single module parallel-kinnematic flexure stage is used which has high orthogonality and minimum out-of-plane motion. To obtain best performance optimal design is performed. For XY stage, to be robust about parasitic motion optimal design of maximizing Z and tilt stiffness is performed under the constraint of motion range and stage size. And for Z stage, optimal design of maximizing 1st resonant frequency is performed. Because if resonant frequency is get higher, scan speed is improved. So it makes reduce the error by sensor drift. Resultly XYZ stage each have 1st natural frequency of 115㎐, 201㎐, 2.66㎑ and range 109㎛, 110㎛, 12㎛.

  • PDF

A Sigma-Delta Modulator With Random Switching Periods (랜덤 스위칭 주기를 갖는 시그마 델타 변조기)

  • Bae, Chang-Han;Kim, Sang-Min;Lee, Gwang-Won
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.10
    • /
    • pp.513-519
    • /
    • 2001
  • This paper proposed a random sigma-delta modulator(RSDM), which is constructed by a 1st order sigma-delta modulator(SDM) and a simple structured random binary generator(RBG). The 1st order SDM produces a switching pulse waveform which has the same low-frequency component as the reference input, while the RBG spreads the distribution of the number of sampling per switching cycle, and thus disperses the spectrum spikes in the output. The relationship between the harmonic spectra and the number of sampling per switching cycle is studied through computer simulations, and the frequency spectra of the RSDM are confirmed in an experimental setup.

  • PDF