• Title/Summary/Keyword: 1m distance

Search Result 2,638, Processing Time 0.033 seconds

A Study on Measurement Accuracy of Theodolite System( I ) - A Measurement Accuracy According to a Theodolite Collimations Distance (데오도라이트 시스템의 측정 정확도에 대한 연구( I ) - 데오도라이트 시준 거리에 따른 측정 정확도)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • A non-contact precision measurement system is a theodolite system, a laser tacker and a photogrammetry system etc. Nowadays, the system reaches to a limit of measurement accuracy required from industrial product of middle and large scale. The one of the solutions for this problem is to maximize the accuracy of the existing measurement system. According to it we performed the study far a measurement accuracy of theodolite system when the distance between two theodolites is changed 1m to 5m. We could blow that the changes of distance affect the measurement accuracy of theodolite system and that the maximum measurement accuracy is $\pm$ 0.02 mm on theodolite distance 3∼4 m.

A Study on the Characteristics of the Spraying Nozzle on Paddy Levee (휴반 살포용 노즐의 분무특성에 관한 연구)

  • 최규홍;손낙율
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.2
    • /
    • pp.3758-3762
    • /
    • 1975
  • In order to find out the optimum size of nozzle of the power sprayer in the paddy field, four different sized hole of nozzles were tested on its discharge volume per unit time and its effective covering distance. 1. The discharge rate of each nozzle is proportional to square root of the transmitted internal pressure of liquid, and the discharge coefficient ranges from 0.82 to 0.86 at the pressure of 20 to 30 kg/$\textrm{cm}^2$. 2. The effective covering distance is increased as the size of the hole is larded and also the pressure is increased under under the limited pressure. Generally, the effective covering distance is not greatly increased at the pressure of above 25kg/$\textrm{cm}^2$. The distance from the nozzle to the spot where the largest amount of droplets are dropped is about 14.5m for 3.05mm nozzle and 16m for 4.05mm nozzle in the pressure range from 20 to 25kg/$\textrm{cm}^2$. 3. From the above results it is concluded that the 3mm nozzle with the power sprayers, which are now being supplied to the farmers, can be used for disease and insect control on the paddy field of which block size is 30m${\times}$100m, and operators need not to enter the field for spraying. For the 40m${\times}$100m block, 4mm nozzle should be used with large size of pump which discharge capacity is 60l/min or more.

  • PDF

Propagation Characteristics and Effects of Road Traffic Noise (도로교통소음의 전파특성 및 영향)

  • Park, Joon-Cheol;Kim, Yoon-Shin;Kang, Dae-Joon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.4
    • /
    • pp.311-315
    • /
    • 2008
  • This study was performed to investigate propagation characteristics and effects of road traffic noise generated from vehicles. Noise levels of expressway and general road were measured at four points in a straight line based on distance from the road, and analyzed. The average noise level of expressway was 78.9 dBA at 5 m, 76.4 dBA at 10 m, 72.0 dBA at 20 m, 69.0 dBA at 30 m. That of general road was lower about $3.1{\sim}3.5\;dBA$ than that of expressway. There was no significant difference in distance attenuation between expressway noise and general road noise. The farer the distance from source is, the more the attenuation is. The influence range of noise is assessed by noise environmental standards or road noise limits. Noise levels of the time zone were measured at a boundary line of apartment to grasp noise variation by time. The time zone of lowest noises was $3{\sim}4$ a.m. and that of highest noise was $8{\sim}10$ a.m. Data recorded on tapes were analyzed to understand the characteristics of frequency because these characteristics are important factors to plan the noise reduction measures, namely path measures.

DISTANCES OF GLOBULAR CLUSTERS BASED ON HIPPARCOS PARALLAXES OF NEARBY SUBDWARFS

  • SAAD SOMAYA MOHAMED;LEE SANG-GAK
    • Journal of The Korean Astronomical Society
    • /
    • v.34 no.2
    • /
    • pp.99-109
    • /
    • 2001
  • In the present study we have determined the distance moduli for seven globular clusters M2, M3, Ml0, M12, NGC 2808, NGC 6229, and NGC 6752, whose metallicities are in the range -1.54 < [Fe/H] < -1.10. We have derived distances for them by the main-sequence fitting method using a sample of local subdwarfs, whose accurate parallaxes are taken from the Hipparcos Catalog. The derived distance moduli are 15.52 for M2, 14.98 for M3, 14.23 for Ml0, 14.03 for M12, 15.56 for NGC 2808, 17.34 for NGC 6229, and 13.29 for NGC 6752.

  • PDF

Study on Changes in Racehorses' Metabolites and Exercise-related Hormones before and after a Race

  • Yoo, In-Sang;Lee, Hong-Gu;Yoon, Sei-Young;Hong, Hee-Ok;Lee, Sang-Rak
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.11
    • /
    • pp.1677-1683
    • /
    • 2007
  • Physiological changes in thoroughbred racehorses during the race were investigated by measuring concentrations of metabolites and exercise-related hormones before and after a race. The conversion point from anaerobic to aerobic exercise during the race was estimated subsequently. Blood samples were taken from the jugular vein of 53 thoroughbreds at different times -three h before and 45 min after- for measuring the concentrations of glucose, non-esterified fatty acids (NEFA), lactate, uric acid, ammonia, insulin, adrenocorticotrophin (ACTH) and cortisol according to the race distance. In accordance with the race distance, each metabolite increased in concentration compared with the level before the race. The level of glucose, in particular, increased from $56.18{\pm}3.20$ mg/dl before the race to $148.82{\pm}8.82$ mg/dl after the race for horses that raced 1,400 m, showing a significant increase of 165% (p<0.001). The concentration of NEFA rose from $76.77{\pm}5.59$ uEq/L to $335.85{\pm}35.39$ uEq/L, up 337% (p<0.01) after a 1,400 m race. Exercise-related hormones also showed similar changes. The level of insulin dropped the most in horses that raced 1,400 m, by 42%, from $0.97{\pm}0.18$ to $0.56{\pm}0.05\;{\mu}g/L$ (p<0.5); however, ACTH and cortisol jumped significantly at 1,800 m, from $20.17{\pm}2.12$ to $551.45{\pm}91.33$ pg/ml (p<0.5) and $1.13{\pm}0.16$ to $5.66{\pm}0.45\;{\mu}g/dl$ (p<0.01), respectively, representing the highest increase. Therefore, based on the changes in glucose, NEFA and insulin levels before and after the race, it was concluded that the race distance of 1,400 m represents the point where racehorses make a conversion from anaerobic to aerobic exercise.

DETERMINATIONS OF ITS ABSOLUTE DIMENSIONS AND DISTANCE BY THE ANALYSES OF LIGHT AND RADIAL-VELOCITY CURVES OF THE CONTACT BINARY - I. V417 Aquilae (접촉쌍성의 광도와 시선속도곡선의 분석에 의한 절대 물리량과 거리의 결정 -1. V417 Aquilae)

  • 이재우;김천휘;이충욱;오규동
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.2
    • /
    • pp.73-82
    • /
    • 2004
  • New photometric and spectroscopic solutions of W-type overcontact binary V 417 Aql were obtained by solving the UBV light curves of Samec et al. (1997) and radial-velocity ones of Lu & Rucinski (1999) with the 2003 version of the Wilson-Devinney binary code. In the light curve synthesis the light of a third-body, which Qian (2003) proposed, was considered and obtained about 2.7%, 2.2%, and 0.4% for U, B, and V bandpasses, respectively. The model with third-light is better fitted to eclipse parts than that with no third-light. Absolute dimensions of V417 Aql are determined from our solution as $M_1$= 0.53 $M_{*}$, $M_2$= 1.45 $M_{*}$, $R_1$= 0.84 $R_{*}$, and $R_2$= 1.31 $M_{*}$, and the distance to it is deduced as about 216pc. Our distance is well consistent with that (204pc) derived from Rucinski & Duerbeck's (1997) relation, $M_{v}$ = $M_{v}$(log P, B-V), but is more distant than that (131$\pm$40pc) determined by the Hipparcos trigonometric parallax. The difference may result from the relatively large error of Hipparcos parallax for V 417 Aql.l.

The Selter Selection Plan due to Formaldehyde Leakage (산화프로필렌의 누출영향평가에 따른 안전거리 산정)

  • Seongju Oh;Sanghun Han;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.11-22
    • /
    • 2024
  • This study aims to present safety distances by the damage impact assessment of the leakage of propylene oxide. As a result of the experiment, the pressure 1psi range was 52m to 169m, the radiant heat 18kW/m2 range was 63m to 163m, the AEGL-2 range was analyzed as 224m to 414m, and the fire ball diameter was analyzed to be 45m to 121m. Additionally, the extent of damages was proportional to the amount of propylene oxide stored or handled. The safe distance for a 10% lethality due to overpressure and radiant heat was calculated to be 134m, and the safe distance for a 0% lethality was 169m. Toxicity was measured at 134m with a lethality 0%. Therefore, the safety distance due to leakage of propylene oxide is calculated to be between 134m and 169m.

Time Series Coastline Change Analysis of Haeundae Beach (해운대 해안의 시기별 해안선 변화량 분석)

  • Lee, Jae One;Kim, Yong Suk;Lee, In Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5D
    • /
    • pp.655-662
    • /
    • 2009
  • The monitoring for analyzing coastline variations throughout many years is conducted in this study. Haeundae Beach is selected as a test area. We have collected RTK-GPS survey data, airborne LiDAR survey data from Sept. 2008 to 2005. We've done airborne LiDAR survey 2009 to 2006 and we would analyze coastline changes time series through interactive comparison analysis. The mean coastline distance of Haeundae shore is 1,347m (RTK-GPS) by airborne LiDAR survey (2 times). Coastline distance is decreased approximately 4.5% than mean distance in the November survey of 2008. We know right and left sides of the coastline are eroded and the center section shows us the littoral deposit of 3~7m toward sea. It turns out that the sand both sides is transported to the center section by a wave and tide and we know the coastline distance is getting smaller but the coastline width is getting longer like 2~7m.

Content of Lead and Cadmium in Organs of Rats by the Distance from Highway (고속도로로부터의 거리에 따른 쥐의 기관내 납과 카드뮴 함량)

  • Lee, Hai-Poong;Wan-Ho Chung
    • The Korean Journal of Ecology
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 1987
  • The concentrations of lead and cadmium in each organ of the rats were measured by the different distance from the Kyungbu highway at Yangjae-dong, Seoul and control site, Dongguk university forest at Mt. Unack, Namyanghu-gun, Kyunggi from 1984 to 1986. The lead was concentrated in the bone with the least. The lead concentration in the bone of the rats inhabiting within 10m from the highway was determined more than 5 times of the control site and significantly this was inversely proportional to the distance from the highway. The cadmium, in the other hand, was specifically concentrated in the kidney as compared with other oragns i.e., the decreasing order of the kidney within 10m from the highway was more than 3 times of that of the control, although the concentration in the organs was not significantly related with the distance from the highway.

  • PDF

The Kinematic Analysis and Comparison of Foreign and Domestic 100m Elite Woman's Hurdling Techniques (국내외 우수 여자선수 100m 허들동작의 운동학적 비교 분석)

  • Ryu, Jae-Kyun;Yeo, Hong-Chul;Chang, Jae-Kwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.157-167
    • /
    • 2007
  • The purpose of this study was to analyze kinematic techniques in the woman's 100m hurdle. In order to find the kinematic parameters, a 3-D video system for kinematic analysis-kwon3d 3.1(Kwon3D Motion Analysis Program Version 3.1)-was used. Eight JVC video cameras(GR-HD1KR) were used to film the performance of Lee Yeon-Kyoung at a frame rate of 60fields/s. The kinematic characteristics from the first hurdle to last hurdle were analyzed at the clearing hurdle spots such as distance, velocities, heights and angles. The real-life three-dimensional coordinates of 20 body landmarks during each phases were collected using a Direct Linear Transformation procedure. After analyzing the kinematic variables in the 100m hurdle run, the following conclusion were obtained; Lee Yeon-Kyoung had to maintain constant stride lengths between hurdles and increase takeoff distance before clearance and shorter landing distance after clearance. She also had to hit the correct takeoff point in front of the hurdle and extend the lead leg at the moment of landing in order to minimize the loss of velocity. She had to sprint between hurdles as fast as possible over 8m/s and run powerful first stride and shortened third stride preparing for the following hurdle clearances.