• Title/Summary/Keyword: 1G wire

검색결과 121건 처리시간 0.029초

Impaction of a continuous glucose monitoring sensor

  • Park, Kyong Chan;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • 제48권4호
    • /
    • pp.392-394
    • /
    • 2021
  • A 33-year-old man presented to the plastic surgery department for foreign body removal 1 month after the insertion of a continuous glucose monitoring (CGM) sensor (Dexcom G5) in the left upper arm. The patient had used the CGM system for 5 years, and the insertion was done in the usual manner. The entire sensor wire was visible on simple radiography and ultrasonography. In the operating room, and the sensor wire was identified in the intermuscular septum and removed. No foreign body reaction or inflammatory signs were found around the CGM, and the extracted wire measured 2.5 cm. Thus, it was assumed that the whole sensor wire was detached from the transmitter, not fractured. No remnant foreign body was observed on follow-up simple radiography.

Hot-Wire CVD법에 의한 microcrystalline silicon 박막의 저온 증착 및 전기 구조적 특성 (Electrical and Structural Properties of Microcrystalline Silicon Thin Films by Hot-Wire CVD)

  • 이정철;유진수;강기환;김석기;윤경훈;송진수;박이준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2002
  • This paper presents deposition and characterizations of microcrystalline silicon(${\mu}$c-Si:H) films prepared by hot wire chemical vapor deposition at substrate temperature below 300$^{\circ}C$. The SiH$_4$ concentration[F(SiH$_4$)/F(SiH$_4$).+(H$_2$)] is critical parameter for the formation of Si films with microcrystalline phase. At 6% of silane concentration, deposited intrinsic ${\mu}$c-Si:H films shows sufficiently low dark conductivity and high photo sensitivity for solar cell applications. P-type ${\mu}$c-S:H films deposited by Hot-Wire CVD also shows good electrical properties by varying the rate of B$_2$H$\_$6/ to SiH$_4$ gas. The solar cells with structure of Al/nip ${\mu}$c-Si:H/TCO/g1ass was fabricated with single chamber Hot-Wire CVD. About 3% solar efficiency was obtained and applicability of HWCVD for thin film solar cells was proven in this research.

  • PDF

Effects of Air Void at the Steel-Concrete Interface on the Corrosion Initiation of Reinforcing Steel in Concrete under Chloride Exposure

  • Nam Jin-Gak;Hartt William H.;Kim Kijoon
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.829-834
    • /
    • 2005
  • A series of reinforced G109 type specimens was fabricated and pended with a 15 weight percent NaCl solution. Mix design variables included 1) two cement alkalinities (equivalent alkalinities of 0.32 and 1.08), 2) w/c 0.50 and 3) two rebar surface conditions (as-received and wire-brushed). Potential and macro-cell current between top and bottom bars were monitored to determine corrosion initiation time. Once corrosion was initiated, the specimen was ultimately autopsied to perform visual inspection, and the procedure included determination of the number and size of air voids along the top half of the upper steel surface. This size determination was based upon a diameter measurement assuming the air voids to be half spheres or ellipse. The followings were reached based upon the visual inspection of G109 specimens that were autopsied to date. First, voids at the steel-concrete interface facilitated passive film breakdown and onset of localized corrosion. Based upon this, the initiation mechanism probably involved a concentration cell with contiguous concrete coated and bare steel serving as cathodes and anodes, respectively. Second, the corrosion tended to initiate at relatively large voids. Third, specimens with wire-brushed steel had a lower number of voids at the interface for both cement alkalinities, suggesting that air voids preferentially formed on the rough as-received surface compared to the smooth wire brushed one.

쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가? (Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union?)

  • 김경태;신충식;박영철;김동현;김민우
    • 대한정형외과학회지
    • /
    • 제56권3호
    • /
    • pp.245-252
    • /
    • 2021
  • 목적: 이번 연구 목적은 쇄골 간부 복합 골절에서 21G 환 강선으로 골편 고정 후 재건 금속판을 이용한 내고정술 시 영상학적 및 임상적 결과를 분석하고자 하였다. 대상 및 방법: 2005년에서 2019년 사이에 발생한 쇄골 간부 골절 환자 51명 중 최소한의 연부조직 박리를 통한 21G 환 강선으로 골편 고정 후 재건 금속판을 이용한 내고정술을 시행한 환자 32명과 강선을 사용하지 않고 수술한 환자 19명에 대한 후향적 코호트 연구를 시행하였다. 방사선 검사를 통해 정복 및 골유합을 확인하였고, University of California at Los Angeles (UCLA) 점수와 visual analogue scale (VAS) 통증 점수를 통해 두 군 간의 임상적 결과와 방사선적 결과를 비교하였다. 이를 바탕으로 환 강선을 사용하지 않고 수술한 환자를 대조군으로 설정하여 두 군 간의 골유합의 차이를 비교 분석하였다. 결과: 32명의 환자를 대상으로 평균 65주간의 추시관찰을 하였고, 대조군의 경우 19명의 환자를 대상으로 평균 56주간의 추시 관찰을 하였다. 방사선 검사상 32명 환자 모두에서 해부학적 정복 및 골유합을 확인하였다. UCLA 점수는 평균 32.38점, 대조군 33.11점(p=0.395), VAS 점수는 평균 1.00점, 대조군 0.84점으로(p=0.668) 통계적으로 의미 있는 차이가 없었다. 대조군과 비교하였을 때 골유합 시기의 차이에 통계적 유의성이 있었으나(p=0.015) 다른 변수를 통제하였을 때는 통계적으로 유의성이 없음을 알 수 있었다(p=0.107). 결론: 전위성 쇄골 간부 복합 골절에 대해 21G 강선 및 재건 금속판을 이용한 내고정술은 정확한 해부학적 정복과 견고한 내고정을 유지할 수 있었고, 환 강선을 통해 작은 골편도 고정할 수 있었다. 방사선 및 임상 결과에서 만족스러운 결과를 얻었기에 재건 금속판 및 21G 강선을 이용한 내고정술이 수술적 치료의 좋은 선택이 될 수 있다고 생각된다.

층상 실리케이트 첨가에 따른 HDPF/$Mg(OH)_2$/Clay 나노복합재의 특성연구 (Effect of Layered Silicates on Flame retardant and Mechanical Properties of HDPF/$Mg(OH)_2$/Clay Nanocomposites)

  • 민경대;이경용;이호림;김도영;강승훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.260-260
    • /
    • 2010
  • In recent years, polymer/clay nanocomposites have generated a great interest, both in industry and in academia, because they often exhibit remarkable improvement in material properties when compared with the virgin polymer or conventional micro and macro-composites. Among these properties are stiffness, strength, dimensional stability and permeability. [1-3] The dispersion of hydrophilic silicates in a hydrophobic matrix like Polyethylene (PE) is difficult because of the difference in character between PE and Montmorillonite (MMT). Therefore, it is necessary to modify PE with polar groups, which can increase the hydrophilicity of PE. In this study, High density polyethylene (HDPE)/$Mg(OH)_2$/Montmorillonite (MMT) nanocomposites having a various compositions were prepared by a melt blending technique with an internal mixer and properties namely mechanical, morpology, rheological and thermal properties were investigated

  • PDF

산화구리 나노분말을 포함하는 에틸렌글리콜 용액의 열전특성에 관한 연구 (A Study on Thermal Properties of Ethylene Glycol Containing Copper Oxide Nanoparticles)

  • 김창규;이경자;이창규
    • 한국분말재료학회지
    • /
    • 제17권4호
    • /
    • pp.276-280
    • /
    • 2010
  • In the present work, ethylene glycol-based (EG) copper oxide nanofluids were synthesized by pulsed wire evaporation method. In order to explode the pure copper wire, high voltage of 23 kV was applied to the both ends of wire and argon/oxygen gas mixture was used as reactant gas. EG-based copper oxide nanofluids with different volume fraction were prepared by controlling explosion number of copper wire. From the transmission electron microscope (TEM) image, it was found that the copper oxide nanoparticles exhibited an average diameter about 100 nm with the oxide layer of 2~3 nm. The synthesized copper oxide consists of CuO/$Cu_2O$ phases and the Brunauer Emmett Teller (BET) surface area was estimated to be $6.86\;m^2\;g^{-1}$. From the analyses of thermal properties, it is suggested that viscosity and thermal conductivity of EG-based copper oxide nanofluids do not show temperature-dependent behavior over the range of 20 to $90^{\circ}C$. On the other hand, the viscosity and thermal conductivity of EG-based copper oxide nanofluids increase with volume fraction due to the active Brownian motion of the nanoparticles, i.e., nanoconvection.

고강도 극 세선의 피로 특성 향상을 위한 특정 인자 제시 (Critical Parameters governing on the Fatigue Properties in the Hyper-eutectoid Steel Wires used for Automotive Tire)

  • 양요셉;배종구;박찬경
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 추계학술대회 논문집
    • /
    • pp.124-127
    • /
    • 2007
  • In this study, we focused on investigation of governing parameters affected on the fatigue properties in the hyper-eutectoid steel wires used for TBR tires. Steel wires are fabricated under different drawing strain from 3.36 to 3.80. Their diameters are 0.21 mm and 0.185mm, respectively. The fatigue properties was measured by hunter rotating beam tester, specially designed thin-sized steel wires. The results showed that the fatigue properites of steel wire, marked as A-1, were greater than the others, due to the low value of residual stress. In order to elucidate the variations of fatigue properties, the microstructure, surface defect and residual stress were observed and measured by useful analysis technique, such as TEM, 3D profiler and FIB.

  • PDF

Effect of the Change in Electrode Construction for the Improvement of Ozone Characteristic of a Superposed Discharge Type Ozonizer

  • Rahman, Fayzur
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.17-22
    • /
    • 1999
  • In this paper a new discharge type ozonizer comprising the superpose operation of silent and surface discharge is presented. The ozonizer consists of two concentric glass tubes with three type of discharge electrodes : the external electrode(EE), the internal electrode(IE) and the central electrode(CE). By varying the structure of IE and materials of CE, we analyzed the characteristics of ozone related different parameters including $O_{3con}$, $O_{3g}$, and $O_{3Y}$. Using Cu made CE it was found the O3con is higher with Cu tape than that with Cu coil wound IE. At Q = 1[l/ min] the values of O3con were found as 3000[ppm] with Cu tape wound IE and 1898[ppm] with Cu coil wound IE. Then using SUS wire made CE with Cu tape wound IE at Q = 1[ι/ min] the maximum value of O3con was found as 5632[ppm]. It was observed that both $O_{3con}$ and $O_{3y}$ are higher with SUS made CE than that with Cu made CE. The maximum values of $O_{3Y}$ were found as 79[g/kWh] with Cu made CE and 170[g/kWh] with SUS wire made CE.

  • PDF

특징형상 기반 자동차 전장도면설계 시스템 개발 연구 (A Development of Feature-based Wire Harness Drawing System)

  • 이상준;이수홍
    • 한국CDE학회논문집
    • /
    • 제1권3호
    • /
    • pp.177-188
    • /
    • 1996
  • An approach to providing computational support with an expert shell is discussed with the scope of an industrial wire harness design, especially at a manufacturing stage. Key issues include the development of an architecture that supports a frequent design change among engineers associated with different parts of the wiring design process and the development of hierarchical representations that capture the different characteristics (e.g., connectivity, configuration) of the harnesses. The abstraction of design information results in features, while the abstraction of drawing elements leads to the definition of objects. These abstractions are essential for efficient transactions among people and computer tools in a domain that involves numerous interacting constraints. In this paper the strategy for the problem decomposition, the definition of features, and the ways in which features are shared by various operations and design changes, are discussed. We conclude with a discussion of some of the issues raised by the project and the steps underway to address them.

  • PDF

Bi2212/Ag 선재의 초전도 특성에 대한 열처리의 영향 (Effect of Heat Treatment on Superconducting Properties on Bi2212/Ag Wire)

  • 김상철;하동우;송규정;오상수;이남진;한일용;오재근;손호상
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.54-58
    • /
    • 2006
  • We have fabricated double stacked 385 filamentary Bi2212/Ag round wires which have different Ag ratios. The wires have been heat-treated at the maximum temperature($T_{max}$) of $882{\sim}896^{\circ}C$ for 0.5 h. Effect of heat treatment on critical current density and critical temperature on Bi2212/Ag round wires has been studied. Critical current density of the wire heat -treated at $890^{\circ}C$ showed 206,250 $A/cm^2$ at 4.2 K, 0 T and critical temperature of the wire was 83 K. Microstructure of the wires also has been studied via optical microscopy and SEM.

  • PDF