• 제목/요약/키워드: 18-8 stainless steel wire

검색결과 9건 처리시간 0.03초

교정용 스테인리스강선재의 물리적 성질에 관한 비교연구 (A COMPARATIVE STUDY ON PHYSICAL PROPERTIES OF ORTHODONTIC STAINLESS STEEL WIRES)

  • 권오원;손병화
    • 대한치과교정학회지
    • /
    • 제15권2호
    • /
    • pp.163-174
    • /
    • 1985
  • The requirements of orthodontic wire should include chemical stability, non-discoloration and non-corrosion in oral environment. Ability to be soldered, ease of fabrication and elasticity should be also considered. The purpose of this study was to compare and analyze the physical properties of Tru-chrome wire and manufactured E.S.S. (Experimental Stainless Steel) wire similar to Tru-chrome. The results were as follows: 1. Tru-chrome wire and E.S.S. wire were SUS 304 which was 18 Cr-8Ni austenite stainless steel. There was not significant difference in each composition between two wires. 2. There were not significant differences in ultimate tensile strength, yield strength, elongation and modulus of elasticity between Tru-chrome and E.S.S. wires. 3. There was not significant difference between flexuree modulus of elasticity of Tru-chrome and E.S.S. wires. 4. Micro-hardness value of E.S.S. wire was more than that of Tru-chrome wire and they were softened significantly by solution heat reatment. 5. Micro-structure of Tru-chrome and E.S.S. wires showed fibrous interlocking grains, and an austenite structure after solution heat treatment. 6. There was significant difference between corrosion rate of Tru-chrome and E.S.S. wires.

  • PDF

치과교정용 wire 납착시 가열온도의 변화가 제특성에 미치는 영향 (Impact on the characteristics by heating temperature change during orthodontic wire solder)

  • 이규선
    • 대한치과기공학회지
    • /
    • 제32권2호
    • /
    • pp.65-74
    • /
    • 2010
  • Purpose : To understand the impact on the strength or restoration force by the change of heating temperature when soldering 18-8 stainless steel round wire which is the chrome-nickel class for dental orthodontic device production. Methods : The following conclusions were made upon the results from tensile strength test, 3 point bending test, and $90^{\circ}$ bending fatigue test with 24 samples that had been applied with condition 1 (before heat treatment - natural) and condition 2 (after heat treatment - mooring 30 seconds after heating up to $500^{\circ}C$, $700^{\circ}C$, and $900^{\circ}C$) to ${\phi}0.4mm$, ${\phi}0.7{\beta}mm$, 18-8 stainless steel round wire (spring hard) by Jinsung Company. Results : When it was heat-treated at $900^{\circ}C$, both ${\phi}0.4mm$ and ${\phi}0.7mm$ showed very low tensile strengths compared to the heat treated cases at $500^{\circ}C$ and $700^{\circ}C$ Yield strengths of both ${\phi}0.4mm$ and ${\phi}0.7mm$ showed very low compared to the heat treated cases at natural, $500^{\circ}C$, and $700^{\circ}C$, as well. Upon the results of 3 point bending test, the heat treated case at $900^{\circ}C$ showed very low in both ${\phi}0.4mm$ and ${\phi}0.7mm$, compared to the heat treated cases at natural, $500^{\circ}C$, and $700^{\circ}C$. Tensile strength of both ${\phi}0.4mm$ and ${\phi}0.7mm$ as well, showed very low compared to the heat treated cases at natural, $500^{\circ}C$, and $700^{\circ}C$. Upon the results of $90^{\circ}$ bending fatigue test, the heat treated case at $900^{\circ}C$ showed the highest wave node resistance in both ${\phi}0.4mm$ and ${\phi}0.7mm$. Conclusion : This study concluded that heating temperature change during wire soldering impacts on the characteristics of orthodntic wire.

평활관 및 와이어코일을 삽입한 열전달촉진관에서 액체질소의 흐름비등열전달 특성 (Flow Boiling Heat Transfer Characteristics of Liquid Nitrogen in Plain and Wire Coil Inserted Tubes)

  • 황지상;윤린;김용찬;정진택
    • 대한기계학회논문집B
    • /
    • 제29권8호
    • /
    • pp.927-933
    • /
    • 2005
  • Boiling heat transfer characteristics of liquid nitrogen in a stainless steel plain tube and wire coil inserted tubes were investigated. The test tubes, which had an inner diameter of 10.6 m and a length of 1.65 m, were horizontally located. Five wire coils having different pitch and thickness were inserted into the plain tube. The pitches of the wire coils were 18.4, 27.6, and 36.8 m, and the thickness was 1.5, 2.0, and 2.5 mm respectively. Tests were conducted at a saturation temperature of $-191^{\circ}$, mass fluxes from 58 to 105 kg/$m^2s$, and heat fluxes from 22.5 to 32.7 kw/$m^2$. A direct heating method was used to apply heat to the test section. The boiling heat transfer coefficients of liquid nitrogen were represented as a function of vapor quality, which showed significant drop at the dryout vapor quality. The maximum heat transfer enhancement using the wire coil inserted tubes over the plain tube was $174\%$ for 'Wire 3' having a thickness of 2.5 mm and a pitch of 18.4 mm.

Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery

  • Oh, You Na;Ha, Keong Jun;Kim, Joon Bum;Jung, Sung-Ho;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • 제48권4호
    • /
    • pp.265-271
    • /
    • 2015
  • Background: Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Methods: Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Results: Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578), major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99), minor wound complications (3.6% vs. 2.0%, p=0.279), or mediastinitis (0.8% vs. 1.0%, p=1.00). Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068). Conclusion: The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

Spring의 lumen size와 helical coil 형성 위치 변화가 교정력에 미치는 영향 (Impact of Lumen Size and Helical Coil Place Change in Spring on Orthodontic Force)

  • 이규선;이선경;김복동
    • 대한치과기공학회지
    • /
    • 제33권4호
    • /
    • pp.331-337
    • /
    • 2011
  • Purpose: The purpose of this study was to impact of force system change in finger spring that add helical coil one round on orthodontic force. Methods: The following conclusions were drawn from the experiment conducted after bending 90 samples with a CNC wire forming machine while changing the height and lumen size to 1mm - 3mm - 5mm and 2mm - 3mm - 4mm respectively in the coil of the force system in finger spring added with one wheel of helical coil of 18-8 stainless steel round wire (${\Phi}0.5mm$, spring hard) from Jinsung Co. in domestic market under the following conditions: Laboratory name = Instron 5942; Temperature($deg^{\circ}C$) = 18.00; Humidity(%) = 50.00; Rate 1 = 10.00000 mm/min; Compressive extension = 5.0mm. Results: When Coil height is 1, 3, 5mm and lumen size is 2, 3, 4mm reduce finger spring as mean value of compressive extension occasion maximum load(mN) increases as coil height rises, and lumen size grows to 5.0mm. And was expose that compressive load(mN) increases as coil position of finger spring rises and increase as lumen size is decrescent. Conclusion: As the adherence height of coil was raised from 1mm through 3mm to 5mm, compressive load increased. As the lumen size increased from 2mm through 3mm to 4mm, compressive load decreased. Therefore, these results suggest that it is desirable to lower the coil height and enlarge the lumen size to enhance the biomechanical efficiency of finger spring when manufacturing the finger spring for removable orthodontic devices.

플럭스 코어드 아크 용접 공정에서의 흄 형성량에 관한 연구 (A Study on Fume Formation Ratio on Flux Cored Arc Welding Process)

  • 윤충식;백남원
    • 한국환경보건학회지
    • /
    • 제25권3호
    • /
    • pp.108-112
    • /
    • 1999
  • A study was conducted for the effects of input energy on fume formation ratios based on electrode(FFR$_{electrode}(g/kg_{electrode})),\;deposited\;metal(FFR_{weld}(g/kg_{weld}))\;and\;slag(FFR_{slag}(g/kg_{slag}))\;at\;CO_2$ flux cored arc welding on stainless steel. Experiments were run in well designed welding fume box. Six types of flux cored wires were used and three levels of current and voltages were given. The measured values of $FFR_{electrode},\;FFR_{weld},\;FFR_{slag}\;are\;7.90{\pm}1.47\;g/kg_{electrode},\;9.18{\pm}1.65\;g/kg_{\electrode},\;71.8{\pm}24.2\;g/kg_{slag}$ respectively. Fume formation ratios are not increased dramatically by input energy because of simultaneous increasing of melted electrodes, deposited metal and slag. The results indicate that the test of fume formation ratios in the research on production of low fume welding wire can be run at the fixed condition of input energy rather than various condition.

  • PDF

다중적층 소재 레이저용접 인자별 열영향 해석 (Parametric Analysis of Thermal Effects on Multi Layered Laser Welding)

  • 최세훈;최해운
    • 한국기계가공학회지
    • /
    • 제20권8호
    • /
    • pp.18-24
    • /
    • 2021
  • Polymers, polymer compounds, are very moldable at low temperatures and have good strength against weight, and hence, are often used in the interior and exterior materials of cars. Owing to the increasing environmental problems, emission regulations have become stricter, which has increased the use of lightweight polymers as substitutes for metal materials. Therefore, as the use of polymer increases, extensive research is being conducted on the bonding technology of polymers, such as polyurethane and epoxy. However, the increased cost and environmental pollution by adhesives caused by the polymer manufacturing plant depend on the chemical composition or the manufacturer's mix ratio. To compensate for this issue, a laser beam is irradiated through a highly permeable polymer (PC) placed on top of an absorbent polymer (ABS) to transfer the laser output to the ABS polymer and fuse them at the interface. Moreover, enabling laser penetrating bonding by placing a stainless steel wire mesh between the two polymers can achieve improved bonding strength compared to conventional heterogeneous polymer bonding.

팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가 (Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom)

  • 임진오;김태형;정양화;최원찬;신지훈;송호영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권4호
    • /
    • pp.21-26
    • /
    • 2003
  • 새로 개발된 다기능 위.십이지장관 코일 카테타의 유용성을 체외실험을 통하여 평가하고자 한다. 위.십이지장 코일 카테타는 전체길이가 150 cm되게 하여 두께 0.3 mm의 스테인레스 세선을 내경 1.3 mm 코일스프링으로 만들고 폴리에틸렌계의 열수축 튜브를 피복하였다. 카테타의 원위부 끝에서 2 0cm 지점까지 금 표식자 7개를 부착하여 방사선 투시상 길이 측정이 가능하게 하였으며, 원위부 7cm, 13 cm, 19 cm 지점에 조영제 분사가 가능하도록 측부 분사구를 제작하였다. 기존의 5 Fr. 혈관용 카테타와 새롭게 제작된 코일 카테타를 대상으로 방사선 불투과도와 조영제 분사능력을 평가하였다. 방사선 불투과도는 필름농도를 비교하였고, 조영제 분사능력은 아크릴을 이용하여 4개의 함을 제작하고 그 내부에 카테타를 위치시킨 후 자동주입기를 이용하여 생리식염수를 주입하여 카테타 내부에 안내철사를 삽입했을 경우와 하지 않았을 경우에서의 조영제 분사율을 측정하였다. 방사선 불투과도는 5 Fr. 혈관용 카테타에서 0.51, 새롭게 제작된 코일 카테타는 0.31이 측정되었고, 조영제 분사량은 5 Fr. 혈관용 카테타는 안내철사를 삽입한 경우와 삽입하지 않은 경우 동일하게 원위부에서만 99.5%분사하였다. 코일 카테타는 안내철사를 삽입한 경우 원위부로부터 각각 1.17%, 18.8%, 41.8%, 38.2%가 분사되었고 안내철사를 삽입하지 않았을 경우 원위부로부터 각각 19.5%, 32.6%, 27.7%, 20.3%가 분사되었다. 새로 개발된 위.십이지장 카테타는 기존의 카테타와 비교하여 방사선 투시상 확인이 용이하여 길이측정이 쉽고, 조영제 분사능력이 우수하여 위.십이지장의 중재시술시 유용하게 사용될 것으로 판단된다.

  • PDF

몇가지 알파입자 방출 핵종의 전해석출 및 알파 스펙트럼 측정에 의한 그의 동위원소 정량 (Electrodeposition of some Alpha-Emitting Nuclides and its Isotope Determination by Alpha Spectrometry)

  • 정기석;서인석
    • 대한화학회지
    • /
    • 제27권4호
    • /
    • pp.279-286
    • /
    • 1983
  • 몇가지의 알파입자를 방출하는 핵종, 즉 악티늄족 원소들, $^{207}Bi$ and $^{210}Po$을 전해석출하는 장치를 만들었다. 스텐레스 원판으로된 환원전극에 이 동위원소들을 석출했으며(석출부분 직경=18mm), 산화전극으로는 백금선을 썼다. 전해질로 염화암모늄을 쓰고, 초기 pH=4, 염소이온농도=0.6M이하, 용액부피=15ml로 하여 1.5암페어(전류밀도=0.59A/$cm^2$)의 전류를 100분간 흘려주어 98.3%의 석출 회수율과 ${\pm}$0.7%의 재현도를 얻었다. 석출된 시료의 알파스펙트럼을 측정한 결과 에너지 분리도로서 $^{210}Po=18.3keV, ^{234}U=21.8keV$$^{239}Pu=36.0keV$인 반치전폭(full width at half maximum)을 얻었다. 국산 천연우라늄(충북·괴산) 시료를 전해석출하여 그의 알파스펙트럼을 구한 결과 $^{238}U\;:\;^{234}U\;=\;:\;6.1{\times}10^{-5}$을 얻었으며 $1.8{\sim}10^{13} neutrons/cm^2{\cdot}sec$인 중성자속으로 144일 동안 쪼여준 238U 시료를 전해석출하여 그의 알파스펙트럼을 구한 결과 $^{238}U\;:\;^{239}Pu\;:\;241Am\;=\;100\;:\;0.0263\;:\;5.20{\times}10^{-5}$을 얻었다. 조사시료중의 $^{238}U$에 대한 본실험의 정량결과는 고체형광측정법 및 질량 스펙트럼법에 의한 결과들과 상대오차 1.6% 이내에서 일치하였으며, $^{239}Pu$의 경우는 음이온교환분리-알파스펙트럼 측정 및 삼불화테노일아세톤(thenoyltrifluoroacetone)을 쓴 용매추출-알파스펙트럼 측정에 의한 정량결과들과 상대오차 ${\pm}$4.0%이내에서 일치하였다.

  • PDF