• 제목/요약/키워드: 17inch

검색결과 86건 처리시간 0.024초

Roll-to-Roll UV 나노 임프린팅 리소그래피에 의한 대면적 17인치의 나노 와이어 그리드의 제작 (Fabrication of a 17inch Area Size Nano-Wire Grid using Roll-to-Roll UV Nano-Imprinting Lithography)

  • 허종욱;남수용
    • 한국인쇄학회지
    • /
    • 제29권3호
    • /
    • pp.17-30
    • /
    • 2011
  • The polarizer is an important optical element used in a variety of applications. Nano-wire grid polarizers in the form of sub-wavelength metallic gratings are an attractive alternative to conventional polarizers, because they provide high extinction ratio. This study has been carried out to fabrication of the 17inch area size nano-wire grid polarizer(NWGP) The master for NWGPs with a pitch of 200nm and the area size $730mm{\times}450mm$ were fabricated using laser interference lithography and aluminum sputtering and wet etching. And The NWGP fabrication process was using by the Roll to-Roll UV imprinting and was applied to flexible PET film. The results were a transmission of light (Tp) 46.7%, reflectance (Rs) 40.1% and Extinction ratio of above 16 for the visible light range.

Construction and actual material test of prism LGP not using function characteristic optical sheet for production of high brightness Back Light Unit

  • Han, J.M.;Yoon, D.K.;Park, D.S.;Oh, Y.S.;Bae, K.W.;Kim, Y.H.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.1233-1235
    • /
    • 2004
  • We have designed High Performance Prism LGP in 17 inch TFT-LCD. In test result to embody high brightness BLU in case of LGP of base and upper surface with 17 inch, thickness 8mm adding prism construct, it is superior brightness improvement than previous that of printing form about some 20% and in this course to embody actual material it succeeded prism LGP production by 17 inch injection form process.

  • PDF

광학시뮬레이션과 새로운 사출성형법을 사용한 TFT-LCD용 고휘도 프리즘 도광판 (High Brightness Prism Light-guide Plate for TFT-LCDs Using Optical Simulation and Novel Injection Mold Process)

  • 한정민;손진근
    • 전기학회논문지P
    • /
    • 제61권2호
    • /
    • pp.93-96
    • /
    • 2012
  • We have designed high performance prism light-guide plate (LGP) in 17 inch TFT-LCD. In test result to embody high brightness BLU in case of LGP of base and upper surface with 17 inch, thickness 8mm adding prism construct. Using optical simulation, we forecast the brightness and uniformity in LGP with prism structure. And we adopted novel injection mold method and Nickel stamper to make actual evolution sample. Novel injection mold process has steady heating time zone in heat cycle time of injection mold process. For this novel heat cycle control, we achieved above 90[%] height prism structure as our design. It is superior brightness improvement than previous that of printing form about some 20[%] and in this course to embody actual material it succeeded prism LGP production by 17 inch injection form process.

The Study of High Brightness Prism Patterned LGP using Optical Simulation Analysis

  • Ok, Chul-Ho;Han, Jeong-Min;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권4호
    • /
    • pp.178-181
    • /
    • 2007
  • We have designed high performance prism light-guide plate (LGP) in 17 inch TFT-LCD. In test result to embody high brightness BLU in case of LGP of base and upper surface with 17 inch, thickness 8 mm adding prism construct, it is superior brightness improvement than previous that of printing form about some 20% and in this course to embody actual material it succeeded prism LGP production by 17 inch injection form process.

CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가 (Imaging Characteristics of Computed Radiography Systems)

  • 정지영;박혜숙;조효민;이창래;남소라;이영진;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.63-72
    • /
    • 2008
  • 최근 의료영상저장 및 전송 시스템(Picture Archiving and Communication System, PACS)의 발전과 함께 디지털 영상의 발전이 가속화되면서, 특히 기존의 아날로그 시스템을 활용할 수 있는 컴퓨터 X-선 촬영(Computed Radiography, CR)의 활용도가 높아졌다. 본 연구에서는 실제 임상에서 사용되고 있는 Agfa CR system (Agfa CR 2.5; Agfa, Belgium)과 Fuji CR system (FCR 9000C; Full, Japan)을 이용하여 영상의 정량적 평가에 널리 사용되고 있는 변조전달함수(Modulation Transfer Function, MTF), 잡음력 스펙트럼(Noise Power Spectrum, NPS), 양자검출효율(Detective Quantum Efficiency, DQE)를 통해 시스템간의 성능 비교 및 I.P (Imaging Plate) 크기별 픽셀 크기 차이 및 선량의 변화에 의한 화질영향을 정량적으로 평가하였다. X-선 영상 획득실험을 위하여 국제표준인 IEC 61267에서 제공하는 RQA5의 선질(Additional Filter $0.7+21Al[mm],\;71[kV_p])$을 사용하였다. 실험 결과 Agfa CR 시스템의 경우 10% 응답의 MTF는 $8{\times}10$ inch와 $14{\times}17$ inch I.P에서 각각 3.9, 2.8 cycles/mm으로 측정되었으며, Fuji CR 시스템의 경우 각각 3.4, 3.2 cycles/mm로 측정되었다 선량의 변화에 따른 MTF도 측정결과는, 두 시스템 모두 선량변화에 따른 MTF의 차이는 크지 않았으며, MTF 10% 응답 주파수 영역도 거의 같은 것을 확인하였다. 이러한 결과를 통하여 선량은 영상의 해상력 및 MTF에는 큰 영향을 미치지 않는 것을 확인하였다. NPS의 경우 Agfa CR 시스템의 $100{\mu}m$ 픽셀 크기를 갖는 $8{\times}10$ inch I.P와 $150{\mu}m$ 픽셀 크기를 갖는 $14{\times}17$ inch I.P사이에 큰 차이가 없었다. 또한 두 시스템 모두 선량이 증가할수록 NPS가 좋아지는 결과를 나타내었다. 진단가능영역인 1.5 cycles/mm 주파수 영역에서 DQE의 효율 측정결과 Agfa CR 시스템의 $8{\times}10$ inch I.P가 11%로 측정되었으며, $14{\times}17\;inch\;I.P$는 8.8%로 측정되었다. Agfa CR 시스템의 DQE 효율 차이는 고주파수 영역에서 두드러지게 나타났다. Fuji CR 시스템의 경우 I.P 크기별 픽셀 크기는 $100{\mu}m$로 동일하였기 때문에 DQE 효율 측정결과 큰 차이를 보이지 않았다. 또한 두 시스템 모두 선량이 증가할수록 DQE 효율은 감소함을 나타내었다. 화질평가의 복합적인 요소를 담고 있는 DQE 측정은 장치의 성능을 점검하고, 환자의 피폭선량을 개선시키는데 중요한 역할을 한다. 본 연구에서는 Agfa CR 시스템과 Fuji CR 시스템의 픽셀 크기별, 선량별 DQE를 측정함으로써 CR 시스템의 임상적 응용의 최적화를 위한 기초 자료로서 이용될 것으로 판단된다.

  • PDF

『상한론』에서 산제의 방촌비와 전비, 환제의 오동자대 크기 수정치 (Revision Volume of Square-inch-spoon, Jeon-bi and Firmiana-Seed-sized Pill Preparations in 『Treatise on Cold Damage Diseases』)

  • 김인락
    • 대한본초학회지
    • /
    • 제37권5호
    • /
    • pp.75-81
    • /
    • 2022
  • Objectives : In 『Treatise on Cold Damage Diseases』, the volume of preparation dosage measured in Hap was 6.5mL. This study aimed to confirm that a square-inch-spoon, which measures powder preparation dosage, was 1/3 Hap, and that Jeon-bi was 1/8 square-inch-spoon. Based on these values, this study also aimed to adjust the diameter of Firmiana-Seed-sized pill preparation, currently known as 6.5mm, so that one square-inch-spoon of powder preparation creates 16 pills. Methods : Calculated the ratio between the floor areas of square-inch-spoon and Jeon-bi and measured the ratio of volume; assumed that powder preparations were stacked as much as possible in the shape of a square pyramid when scooped comfortably, then calculated the slopes of 1/3 Hap and 1/4 Hap; measured the volumes of powdered Oryeongsan and Lijungwhan in square-inch-spoon and Jeon-bi; created the powders into Firmiana-Seed-sized pill preparation; adjusted the diameter of Firmiana Seed so that 16 pills could be created. Results : Inferring from the floor areas, the volume of square-inch-spoon is 9.2 times that of Jeon-bi; one square-inch-spoon should be 1/3 Hap for the powder to reach its maximum slope of 47° and, according to actual measurement of powder preparations, reach its maximum volume; when created into Firmiana-Seed-sized pill preparations, one square-inch-spoon should be 1/3 Hap so that approximately 16 pills were created. Conclusions : One square-inch-spoon of powder preparation was 1/3 Hap(2.17mL), Jeon-bi was 1/8 square-inch-spoon(0.27mL), and the diameter of Firmiana-Seed-sized pill preparation was 5.5mm.

악관절기능장애자의 방사선학적 연구 (A RADIOGRAPHIC STUDY ON TEMPOROMANDIBULAR JOINT TROUBLE)

  • 최병운
    • 치과방사선
    • /
    • 제9권1호
    • /
    • pp.13-18
    • /
    • 1979
  • The purpose of this study was to investigate the radiographic images of Temporomandibular joint trouble patients. This study included 186 patients with the chief complaints of TMJ pain and dysfunction. Their age ranged from 17 to 68 years. All patients were identified in the department of Dental mary of College of Dentistry, Seoul National University, Apr. 1978 to Jun. 1979. The author has observed the radiographic variations of two positions of condylar head taken by modified transcranial oblique-lateral projection, which are one in centric occlusion and the other in 1 inch(2.54㎝) mouth open. The results were obtained as follows; 1. In centric occlusion, the distances and positional relationship between the summit of condylar head and the deepest point of articular fossa revealed more or less large variations; Normal range is of 37.9%, anterior displacement of 37.3% and posterior displacement of 22.6%. 2. In the horizontal movement of condylar heads when on 1 inch mouth open, it was revealed that normalrange was of 46.5%, anterior displacement of 12.3%, posterior displacement of 41. 1 %. 3. In the positional interrelationship of both condylar heads when on 1 inch mouth open, it was revealed that symmetry(71. 5%) occurred approximately 2.5 times as many as asymmetry. 4. In both centric occlusion and 1 inch mouth open, it was showed that almost all estimated figures were greater in male than in female, and in the horizontal movement of condylar head when on 1 inch open, it was showed that hypermobility was dominant in male and hypomobility in female.

  • PDF

Auxiliary Address Pulse Driving Scheme for Improving Luminance and Luminous Efficiency in 42-inch WVGA Plasma Display Panel

  • Park, Ki-Hyung;Lee, Eun-Cheol;Cho, Ki-Duck;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.329-332
    • /
    • 2003
  • The effects of an auxiliary address pulse driving scheme, in which an auxiliary short pulse was applied to the address electrode during a sustain-period, was examined under the various image patterns of the 42-inch WVGA ac-PDP. When the auxiliary address pulse driving scheme was applied, the luminance of the red, green and blue cells were measured respectively. The luminance, luminous efficiency and current were measured under the full-white pattern of the 42-inch ac-PDP. As a result, the luminance of blue cell was improved approximately by 17 %, whereas the luminous efficiency of the full-white pattern was improved approximately by 34 % without a misfiring discharge in comparison with conventional driving scheme.

  • PDF

Auxiliary Address Pulse Driving Scheme for Improving Luminance and Luminous Efficiency in 42-inch WVGA Plasma Display Panel

  • Park, Ki-Hyung;Lee, Eun-Cheol;Cho, Ki-Duck;Tae, Heung-Sik
    • Journal of Information Display
    • /
    • 제5권1호
    • /
    • pp.16-21
    • /
    • 2004
  • The effects of an auxiliary address pulse driving scheme, in which an auxiliary short pulse is applied to the address electrode during a sustain-period, were examined under the various image patterns of the 42-inch WVGA ac-PDP. When the auxiliary address pulse driving scheme was applied, the luminance of the red, green and blue cells were measured respectively. And the luminance, luminous efficiency, and current were measured under the full-white pattern of the 42-inch ac-PDP. As a result, the luminance of blue cells was improved approximately by 17 %, whereas the luminous efficiency of the full-white pattern was improved approximately by 34 % without a misfiring discharge in comparison with conventional driving scheme.

스윙형 역지밸브의 고장 원인 분석과 열림 특성에 관한 실험적 연구 (Analyses of Failure Causes and an Experimental Study on the Opening Characteristics of Swing Check Valves)

  • 송석윤;유성연
    • 한국유체기계학회 논문집
    • /
    • 제8권6호
    • /
    • pp.15-25
    • /
    • 2005
  • Check valves playa vital role in the operation and protection of nuclear power plants. Check valves failure in nuclear power plants often lead to a plant transient or trip. The analysis of historical failure data gives information on the populations of various types of check valves, the systems they are installed in, failure modes, effects, methods of detection, and the mechanisms of the failures. A majority of check valve failures are caused by improper application. The experimental apparatus is designed and installed to measure the disc positions with flow velocity, Vopen and Vmin for 3 inch and 6 inch swing check valves. The minimum flow velocity necessary to just open the disc at a full open position is referred to as Vopen, and Vmin is defined as the minimum velocity to fully open the disc and hold it without motion. In the experiments, Vmin is determined as the minimum flow velocity at which the back stop load begins to increase after the disc is fully opened or the oscillation level of disc is reduced below $1^{\circ}$. The results show that the Vmin velocities for 3 inch and 6 inch swing check valves are about 27.3% and 17.5% higher than the Vopen velocities, respectively.