• Title/Summary/Keyword: 14v lymph node

Search Result 6, Processing Time 0.063 seconds

Indication of Dissection of the 14v Lymph Node in Advanced Distal Gastric Cancer (원위부 진행성 위암에서의 상장간막정맥(14v) 림프절 절제술의 적응증)

  • Lim, Jung-Taek;Jung, Oh;Kim, Ji-Hoon;Oh, Sung-Tae;Kim, Byung-Sik;Park, Kun-Choon;Yook, Jeong-Hwan
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.154-160
    • /
    • 2006
  • Purpose: According to the 2nd English Edition of the Japanese Gastric Cancer Association (JGCA) in 1998, in case of distal gastric cancer, the 14v (superior mesenteric vein) lymph node (LN) is included in the N2 group. However, in Korea, a modified radical gastrectomy is performed, and a 14v LN dissection is not done as a routine procedure. Thus, we investigated the rate of metastatic 14v LNs, evaluated the necessity of dissection of the 14v LN, and searched for indications of 14v LN dissection. Materials and Methods: From April 2004 to August 2005, we enrolled the patients who were diagnosed as having advanced gastric cancer in the distal third portion of the stomach. We peformed a distal gastrectomy with D2 lymph node dissection as defined in the 2nd English edition of the JGCA classification. We calculated the positive rate of metastatic LNs of each station and analyzed the relationship between the positive rates of No.6 LNs and 14v LNs. We also compared the positive 14v LN group with the negative 14v LN group. Results: The total number of patients was 50, the mean age was 56 (range $30{\sim}80$) years, and sex ratio (Male/Female) was 1.63 : 1. In 47 (94%) cases, distal a gastrectomy with gastroduodenostomy was done, and in the remaining 3 (6%) cases, a distal gastrectomy with gastrojejunostomy was done. The most frequently metastatic LNs were nos. 3 and 6 (54%). The metastatic rate of the f4v LN was 10%, which was similar to that of LN no. 9. In the comparison of the 14v positive group with the 14v negative group, there were significant differences in the numbers of metastatic LNs (mean 25.4 vs 4.91, P<0.001) and the numbers of metastatic no. 6 LNs, (mean 6.8 vs 1.42, P<0.001), and if no. 6 LNs were metastatic, the possibility of metastasis to the 14v LN was 19.2%. In the 14v positive group, all cases were more than stage 3 by the UICC 6th edition. Conclusion: In cases of advanced cancer with metastasis to the no. 6 IN, there was a good chance of metastasis to the 14v LN. Thus, in the operative field, if the tumor is advanced to more than stage 3 by the UICC classification and the no. 6 LN is metastatic, a 14v LN dissection is necessary. However, the usefulness of a 14v LN dissection should be evaluated prospectively through an analysis of tumor recurrence and long-term survival.

  • PDF

Virtual lymph node analysis to evaluate axillary lymph node coverage provided by tangential breast irradiation

  • Park, Shin-Hyung;Kim, Jae-Chul;Lee, Jeong Eun;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.33 no.1
    • /
    • pp.50-56
    • /
    • 2015
  • Purpose: To investigate the coverage of axillary lymph node with tangential breast irradiation fields by using virtual lymph node (LN) analysis. Materials and Methods: Forty-eight women who were treated with whole breast irradiation after breast-conserving surgery were analyzed. The axillary and breast volumes were delineated according to the Radiation Therapy Oncology Group (RTOG) contouring atlas. To generate virtual LN contours, preoperative fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scans with identifiable LN were fused with the CT scans, and the virtual LN contour were delineated on the CT. Results: The median level I and II axillary volume coverage percentages at the $V_{D95%}$ line were 33.5% (range, 5.3% to 90.4%) and 0.6% (range, 0.0% to 14.6%), respectively. Thirty-one LNs in 18 patients were delineated (26 in level I and 5 in level II). In the level I axilla, 84.6% of virtual LNs were encompassed by the 95% isodose line. In the level II axilla, by contrast, none of the virtual LNs were encompassed by the 95% isodose volumes. There was a substantial discrepancy between the RTOG contouring atlas-based axillary volume analysis and the virtual LN analysis, especially for the level I axillary coverage. The axillary volume coverage was associated with the body mass index (BMI) and breast volume. Conclusion: The tangential breast irradiation did not deliver adequate therapeutic doses to the axillary region, particularly those in the level II axilla. Patients with small breast volumes or lower BMI showed reduced axillary coverage from the tangential breast fields. For axillary LN irradiation, individualized anatomy-based radiation fields for patients would be necessary.

Predictive Role of Tumor Size in Breast Cancer with Axillary Lymph Node Involvement - Can Size of Primary Tumor be used to Omit an Unnecessary Axillary Lymph Node Dissection?

  • Orang, Elahe;Marzony, Eisa Tahmasbpour;Afsharfard, Aboulfazl
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.717-722
    • /
    • 2013
  • Background: Breast cancer is the most common cancer among women worldwide. The aim of this study was to investigate the relationship between tumor size and axillary lymph node involvement (ALNI) in patients with invasive lesions, to find the best candidates for a full axillary dissection. Additionally, we evaluated the association between tumor size and invasive behavior. The study was based on data from 789 patients with histopathologically proven invasive breast cancer diagnosed in Shohada University hospital in Tehran, Iran (1993-2009). Cinical and histopathological characteristics of tumors were collected. Patients were divided into 6 groups according to primary tumor size: group I ($0.1-{\leq}1cm$), II ($1.1-{\leq}2cm$), III ($2.1-{\leq}3cm$), IV ($3.1-{\leq}4cm$), V ($4.1-{\leq}5cm$) and VI (>5cm). The mean(${\pm}SD$) size of primary tumor at the time of diagnosis was $3.59{\pm}2.69$ cm that gradually declined during the course of study. There was a significant correlation between tumor size and ALNI (p<0.001). A significant positive correlation between primary tumor size and involvement of surrounding tissue was also found (p<0.001). The mean number of LNI in group VI was significantly higher than other groups (p<0.05). We observed more involvement of lymph nodes, blood vessels, skin and areola-nipple tissue with increase in tumor size. We found 15.3% overall incidence of ALNI in tumors ${\leq}2cm$, indicating the need for more investigation to omit full axillary lymph node dissection with an acceptable risk for tumors below this diameter. While in patients with tumors ${\geq}2cm$, 84.3% of them had nodal metastases, so the best management for this group would be a full ALND. Tumor size is a significant predictor of ALNM and involvement of surrounding tissue, so that an exact estimation of the size of primary tumor is necessary prior to surgery to make the best decision for management of patients with invasive breast cancer.

Five-year Survival Associated with Stage I Gastric Cancer after Resection of Early Recurrence at Nodal Station No. 14v: a Case Report

  • Abe, Iku;Kinoshita, Takahiro;Kaito, Akio;Sunagawa, Hideki;Watanabe, Masahiro;Sugita, Shizuki;Tonouchi, Akiko;Sato, Reo
    • Journal of Gastric Cancer
    • /
    • v.17 no.2
    • /
    • pp.186-191
    • /
    • 2017
  • The role of nodal station No. 14v (along the superior mesenteric vein) in lymphadenectomy for distal gastric cancer remains elusive. A 73-year-old woman underwent endoscopic submucosal dissection for gastric cancer, and was referred to our division for additional surgery because of pathologically non-curative resection. A laparoscopic distal gastrectomy with D1+ dissection was performed, with a final diagnosis of pT1bN1M0, Stage IB (2 nodal metastases to No. 6). Four months post-surgery, abdominal computed tomography revealed a 14-mm solitary nodule along the superior mesenteric vein. The lesion was excised and pathologically identified as a lymph node metastasis. Adjuvant chemotherapy with tegafur-gimeracil-oteracil potassium (S-1) was administered for the metastasis. Presently the patient survives without recurrence, 5.5 years after the second operation. Our findings suggest that there is lymphatic flow from the No. 6 to the No. 14v nodal station. Some patients with a No. 6 metastasis may benefit from a No. 14v lymphadenectomy, even in early-staged disease.

Dosimetric Comparison of Intensity Modulated Radiation, Proton Beam Therapy and Proton Arc Therapy for Para-aortic Lymph Node Tumor (대동맥림프절 종양에 대한 세기조절방사선치료, 양성자치료, 양성자회전치료의 선량 비교평가)

  • Kim, JungHoon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.331-339
    • /
    • 2014
  • To test feasibility of proton arc therapy (PAT) in the treatment of para-aortic lymph node tumor and compare its dosimetric properties with advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT) and conventional 3D conformal proton beam therapy (PBT). The treatment plans for para-aortic lymph node tumor were planned for 9 patients treated at our institution using IMRT, PBT, and PAT. Feasibility test and dosimetric evaluation were based on comparisons of dose volume histograms (DVHs) which reveal mean dose, $D_{30%}$, $D_{60%}$, $D_{90%}$, $V_{30%}$, $V_{60%}$, $V_{90%}$, organ equivalent doses (OEDs), normal tissue complication probability (NTCP), homogeneity index (HI) and conformity index (CI). The average doses delivered by PAT to the liver, kidney, small bowel, duodenum, stomach were 7.6%, 3%, 17.3%, 26.7%, and 14.4%, of the prescription dose (PD), respectively, which is higher than the doses delivered by IMRT (0.4%, 7.2%, 14.2%, 15.9%, and 12.8%, respectively) and PBT (4.9%, 0.5%, 14.12%, 16.1% 9.9%, respectively). The average homogeneity index and conformity index of tumor using PAT were 12.1 and 1.21, respectively which were much better than IMRT (21.5 and 1.47, respectively) and comparable to PBT (13.1 and 1.23, respectively). The result shows that both NTCP and OED of PAT are generally lower than IMRT and PBT. This study demonstrates that PAT is better in target conformity and homogeneity than IMRT and PBT but worse than IMRT and PBT for most of dosimetric factor which indicate that PAT is not recommended for the treatment of para-aortic lymph node tumor.

F-18-FDG Whole Body Scan using Gamma Camera equipped with Ultra High Energy Collimator in Cancer Patients: Comparison with FDG Coincidence PET (종양 환자에서 초고에너지(511 keV) 조준기를 이용한 전신 F-18-FDG 평면 영상: Coincidence 감마카메라 단층 촬영 영상과의 비교)

  • Pai, Moon-Sun;Park, Chan-H.;Joh, Chul-Woo;Yoon, Seok-Nam;Yang, Seung-Dae;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.65-75
    • /
    • 1999
  • Purpose: The aim of this study is to demonstrate the feasibility of 2-[fluorine-18] fluoro-2-deoxy-D-glucose (F-18-FDG) whole body scan (FDG W/B Scan) using dual-head gamma camera equipped with ultra high energy collimator in patients with various cancers, and compare the results with those of coincidence imaging. Materials and Methods: Phantom studies of planar imaging with ultra high energy and coincidence tomography (FDG CoDe PET) were performed. Fourteen patients with known or suspected malignancy were examined. F-18-FDG whole body scan was performed using dual-head gamma camera with high energy (511 keV) collimators and regional FDG CoDe PET immediately followed it Radiological, clinical follow up and histologic results were correlated with F-18-FDG findings. Results: Planar phantom study showed 13.1 mm spatial resolution at 10 cm with a sensitivity of 2638 cpm/MBq/ml. In coincidence PET, spatial resolution was 7.49 mm and sensitivity was 5351 cpm/MBq/ml. Eight out of 14 patients showed hypermetabolic sites in primary or metastatic tumors in FDG CoDe PET. The lesions showing no hypermetabolic uptake of FDG in both methods were all less than 1 cm except one lesion of 2 cm sized metastatic lymph node. The metastatic lymph nodes of positive FDG uptake were more than 1.5 cm in size or conglomerated lesions of lymph nodes less than 1cm in size. FDG W/B scan showed similar results but had additional false positive and false negative cases. FDG W/B scan could not visualize liver metastasis in one case that showed multiple metastatic sites in FDG CoDe PET. Conclusion: FDG W/B scan with specially designed collimators depicted some cancers and their metastatic sites, although it had a limitation in image quality compared to that of FDG CoDe PET. This study suggests that F-18-FDG positron imaging using dual-head gamma camera is feasible in oncology and helpful if it should be more available by regional distribution of FDG.

  • PDF