• 제목/요약/키워드: 14dB

검색결과 2,434건 처리시간 0.03초

A Differential Voltage-controlled Oscillator as a Single-balanced Mixer

  • Oh, Nam-Jin
    • International journal of advanced smart convergence
    • /
    • 제10권1호
    • /
    • pp.12-23
    • /
    • 2021
  • This paper proposes a low power radio frequency receiver front-end where, in a single stage, single-balanced mixer and voltage-controlled oscillator are stacked on top of low noise amplifier and re-use the dc current to reduce the power consumption. In the proposed topology, the voltage-controlled oscillator itself plays the dual role of oscillator and mixer by exploiting a series inductor-capacitor network. Using a 65 nm complementary metal oxide semiconductor technology, the proposed radio frequency front-end is designed and simulated. Oscillating at around 2.4 GHz frequency band, the voltage-controlled oscillator of the proposed radio frequency front-end achieves the phase noise of -72 dBc/Hz, -93 dBc/Hz, and -113 dBc/Hz at 10KHz, 100KHz, and 1 MHz offset frequency, respectively. The simulated voltage conversion gain is about 25 dB. The double-side band noise figure is -14.2 dB, -8.8 dB, and -7.3 dB at 100 KHz, 1 MHz and 10 MHz offset. The radio frequency front-end consumes only 96 ㎼ dc power from a 1-V supply.

가상환경의 인터랙티브 사운드를 위한 'EVE-SoundTM' 툴킷 ('EVE-SoundTM' Toolkit for Interactive Sound in Virtual Environment)

  • 남양희;성숙정
    • 정보처리학회논문지B
    • /
    • 제14B권4호
    • /
    • pp.273-280
    • /
    • 2007
  • 본 논문은 2D/3D 가상환경에서 실감 사운드의 실시간 합성을 위한 $EVE-Sound^{TM}$ 툴킷의 설계와 개발결과를 제시한다. $EVE-Sound^{TM}$는 사운드 효과 계산에 필요한 장면요소를 간추리는 전처리 도구와 실시간 렌더링 API들로 구성되며, 다중 모달리티의 실감 재현을 필요로 하는 가상현실, 게임 등의 각종 인터랙티브 콘텐츠에서 사용자에게 고급 그래픽 환경을 허용하면서 동시에 사운드의 실시간 재현을 가능하게 함을 목표로 하였다. 3차원 사운드 계산이 매우 복잡하기 때문에 기존의 사운드 API들이 간단한 사운드 효과와 재생을 제공하는 것과 달리, 복잡한 가상환경에서 3차원 사운드의 원리를 반영하되 그 렌더링을 실시간화하는 데 초점을 두었고, 이를 위해 새로운 장면 간략화 및 공간사운드 계산 방법이 제시되었다. 응용 사례 및 실험, 알고리즘 분석을 통해 제시된 툴킷의 활용성 및 향상된 실시간성을 확인하였다.

어류가 내는 소리에 관하여 (A Study on the Noises of Fishes)

  • 조암;장지원
    • 수산해양기술연구
    • /
    • 제8권1호
    • /
    • pp.14-22
    • /
    • 1972
  • For the development of acoustic fishing method, the noises of fishes have been recorded and analy/'ed by many scientists. Some specimens of fishes were selected as such Cyprinus carpio, Ctenopharyngodon idellus Carassius carassius, and pagrosol1ms major in this experiment. The noises such as feeding noise, driving away noise, jumping noise and fi llip noise were recorded by the tape recorder, Sony Model 262, through the underwa te r microph I one, Oki ST 6582, and analyzed in frequencies bv octave band analyzer, Rion SA-55, and sound pressure level of source by sound level meter, Rion NA-opNN The supplied feed was placed within 5em apart from the hydrophone. The result of analyzed noises were as follow. Cyprinus carjJio; Feeding noise 250- 500 cps, 92- 99 dB Driving away noise 125-2, 000 eps, 101-112 dB Jumping noise 125-2, 000 eps, 99-116.5 dB Ctenopharyngodon idcllus; Driving away noise 125-1, 000 cps, 96-109 dB Carassius carassius; Feeding noise 250- 500 cps, 91. 5- 99.5 dB Driving away noise 125-1, 000 eps, 99-108 dB Carassius auratus Feeding noise 250 eps, 94-101 dB Driving away noise 125-1, 000 cps, 98-110 dB Pagrosomus major Feeding noise 230-500 cps, 90-101 dB Fillip noise 500 cps, 98-108 dB (1) Feeding noise was produced as like as snap noise of twig and gulping down saliva noise in human and dominant frequency range of the noise is 250-500 cps and noise level 90-101 dB. (2) It was found that feeding noise were not a monotonic but a complex tones though fish took the same food. (3) Driving away noise was produced not so keen and the wave form of the noise is rising very sharp and big amplitude in the oscillograph. Dominant frequency range of this noise was about 150-1, 000 cps and noise level 96-112 dB except thut of carp. (4) The frequency of snapper's fillip noise, when it produced by caudal fin in swimming at the surface of water, was 500 cps and noise level 93-108 dB snd that of jumping noise of carp about 150-2, 000 cps and noise level 99-116.5 dB.

  • PDF

Hematological Characteristics of the Cultured Eel, Anguilla japonica by Vibration Stress

  • Kim, Dae-Hee;Nam, Myung-Mo;Lee, Si-Woo;Kang, Kyoung Ho;Kang, Yue Jai;Hur, Jun Wook
    • 한국해양생명과학회지
    • /
    • 제3권2호
    • /
    • pp.81-86
    • /
    • 2018
  • The purpose of this study is to determine the effects of vibration on primary (e.g. plasma cortisol), secondary (e.g. plasma glucose, aspartate aminotransferase (AST), alanine aminotransferase (ALT), Na+, K+ and Cl- and tertiary (e.g. mortality) stress responses in cultured eel, Anguilla japonica. For this purpose, three groups (including one control group and two stress groups) were set up. The control group was made exposed to vibration corresponding to 48 decibel (dB, V) (produced using electric vibrators) for 15 minutes per hour every day, and the two stress groups was made exposed to vibration corresponding to 58 and 68 dB (V) (produced using the same electric vibrators), equally, for 15 minutes per hour every day. Blood was sampled at day 0 (before starting vibration stress tests, BS), and days 1, 3, 5, 7, 9 and 11 (after starting vibration stress tests). As a result, plasma cortisol showed trend to continuously rise by consecutive stress from 4.1±0.1 ng/ml in BS. In 48 dB group (control), cortisol showed the highest level with 7.6±0.9 ng/ml after 7 days (p<0.05), but at 9 and 11 days was not significantly compared with BS level. In 58 dB group, the cortisol showed the highest level with 43.1±4.8 ng/ml after 1st day. Cortisol of 68 dB group increased significantly during the experimental period (14.4±2.3~32.0±5.7 ng/ml) (p<0.05). In 58, and 68 dB groups during the experimental period differed significantly compared to 48 group (p<0.05). Glucose in 48 dB were increased from 42.0 ±5.7 (BS) to 52.5±2.1 (1 day), the level was not significantly from 1 to 11 days. Glucose in 58 and 68 dB groups was increased significantly than BS during experimental period (p<0.05). K+ in 68 dB increased significantly (p<0.05) from 2.3±0.2 mE/ql (BS) to 3.3±0.5 mE/ql at 5 days. In 48 and 58 dB groups during the experimental period differed significantly (p<0.05). Na+ and Cl- levels were not differed significantly during the experimental period. AST and ALT in 58 and 68 dB groups showed trend to continuously rise by consecutive stress. At 7 and 9 days in AST, between 48, 58 and 68 dB groups differed significantly (p<0.05). In 48, 58 and 68 dB groups at 1 day, blood hematocrit increased significantly higher than BS. The 11 days after vibration stress, the mortality in 48, 58 and 68 dB groups was 1.1, 5.1 and 5.8%, respectively. The present results have shown that A. japonica exhibited ''typical'' physiological responses when exposed to chronic vibration stress. These data suggested that chronic vibration stress caused substantial stress in the fish; especially the persisting elevated plasma AST and ALT levels observed would be expected to adverse effect. In conclusion, chronic vibration stress could greatly affects the hematological characteristics in A. japonica.

GaAs Hyperabrupt Junction 바랙터 다이오드와 리액턴스 정합을 이용한 Ka-Band 아날로그 위상변화기의 설계 (Design and fabrication of Ka-Band Analog Phase Shifter using GaAs Hyperabrupt Junction Varactor Diodes and Reactance Matching)

  • 조성익
    • 한국전자파학회논문지
    • /
    • 제14권5호
    • /
    • pp.521-526
    • /
    • 2003
  • 본 논문에서는 Ka-band에 대한 반사형 아날로그 위상변화기의 설계 및 제작결과를 기술하였다. 큰 위상 변화를 가지기 위해서 병렬의 GaAs hyperabrupt junction 바랙터 다이오드와 리액턴스 정합 방법을 사용하였으며 이론적인 설계공식도 도출하였다. Ka-band에서는 조립과정도 중요하며 조립과정중 발생할 수 있는 기생성분을 최소화하기 위한 조립절차도 포함하였다. 제작결과는 Ka-Band에서 기존 것보다 큰 220$^{\circ}$$\pm$7$^{\circ}$ 가변의 위상변화와 삽입손실이 5 dB$\pm$1 dB를 가진 우수한 성능의 측정된 결과를 얻었다.

소구경 화기의 사격음 특성에 대한 비교분석 연구 (A Experimental Comparison Analysis for the Characteristics of Impulse Noise Caused by Shooting of Small Arms)

  • 박미유;심철보;홍준석
    • 한국소음진동공학회논문집
    • /
    • 제26권5호
    • /
    • pp.578-583
    • /
    • 2016
  • In order to provide a basis data for design of small arms and their silencer, an experimental study on firing noise of small arms was performed around the muzzle of a gun. For this experimental comparison analysis, the target small arms were included most operating small arms in our country. The sound pressure levels were measured at a certain distance which was predetermined according to US army firing test procedure, TOP 3-2-045. By this experimental study, the sound pressure levels of 5.56 mm caliber small arms are 143 dB ~ 145.4 dB and 7.62 mm caliber small arms are 144 dB ~ 145.2 dB. Between the heavy machine gun K12 and M60, the sound pressure level of K12 is slightly lower than M60.Also silencer for K14 snifer rifle was tested. Using this result, it has been found that the reduction effect of the silencer is 15.4 dB but the improvements of silencer performance in the high frequency range have to be studied later on.

KRM 모델을 이용한 고등어(Scomber japonicus)의 음향산란특성 규명 (Acoustic scattering characteristics of chub mackerel (Scomber japonicus) by KRM model)

  • 박근창;오우석;오선영;이경훈
    • 수산해양기술연구
    • /
    • 제58권1호
    • /
    • pp.32-38
    • /
    • 2022
  • In this study, Target strength for multi-frequency (38 kHz, 70 kHz, 120 kHz and 200 kHz) of chub mackerel (Scomber japonicus) was estimated using by the KRM model. The body shape of the Chub mackerel was described by an X-ray system and the body length of 20 individuals ranged from 16 cm to 28 cm. The swimbladder tilt angle ranged between -8 and -14°, the maximum TS value according to the swimming angle of chub mackerel was -33.0 dB at -11°. The averaged TScm according to fork length was -66.02 dB at 38 kHz, -66.50 dB at 70 kHz, -66.00 dB at 120 kHz and -67.35 dB at 200kHz, respectively.

여자 500m 쇼트트랙 스피드 스케이팅의 스타트 기술분석 (Analysis of the Female 500m Sprint Starting Motion in Short Track Speed Skating)

  • 백진호;곽창수;정남주
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.285-299
    • /
    • 2004
  • The purpose of this study is to identify female 500m sprint start motion by the center of gravity position in short track speed skating. The center of gravity position ratio was divided into three type(type A front : 80%-back : 20%, type B front : 70%-back 30%, type C front: 50%-back : 50%). Three video cameras were used for 3D motion analysis with DLT method and the results were as follows: The elapsed time in starting motion was appeared that type B was the shortest and type A was the longest. It was appear that the stroke length of type A was longer than that type B and C during starting phase. This result was similar to displacement of center of gravity. It was appeared that skill type of center of gravity position ratio type B' ankle and knee joint angle were lower than that of type A and C. Observing these results it was conclusion that skill type B of center of gravity position ratio was more faster than that of type A and C. But it is important that these skill type needed to verifying more subjects.

B3 Pliot plant를 이용한 고농도 질소부하에서의 고도처리에 관한 연구 (The study for Biological nutrient removal of High-strength nitrogen loading rate using B3 pilot plant)

  • 엄태규;한동엽;김부길
    • 한국환경과학회지
    • /
    • 제14권8호
    • /
    • pp.771-775
    • /
    • 2005
  • The purpose of this research was to investigate applicative possibility of field. Pilot-scale experiments were conducted, at outdoor temperature, HRT l0hour, IR(Internal Recycle) $150\%$ and used $2.8m^3$ Reactor. External carbon source was varied 80 to 120 mg/L. When External carbon source and Alkalinity were injected to the B3 pilot plant, the removal efficiencies of COD and BOD were not decreased. Nitrification rate were 5.95, 5.40, 4.08 $mgNH_4^+-N/gSS/d$ during operation periods and denitrification rate was $3.l2mgNO_3^--N/gSS/d.$ When we surveyed the relationship between loading rate of nitrogen and nitrogen removal quantity, this data was 0.949, B3 process will be possible application process of field.

발생 해역별 태풍의 수와 세기에 관한 연구 (A Study on Typhoon Numbers and Intensity According to the Sea Areas of Occurrence)

  • 설동일
    • 한국항해항만학회지
    • /
    • 제33권10호
    • /
    • pp.679-683
    • /
    • 2009
  • 최근 22년간(1986-2007년)의 기상청 자료를 이용하여 태풍의 발생 해역별(A해역: 캐롤라인 마샬군도 부근 해역, B해역 : 북위 20도 이북 해역, C해역 : 필리핀 근해, D해역 : 남중국해)로, 태풍의 발생 수 및 세기에 관하여 분석하였다. 태풍의 연평균 발생 수는 26.3개로, 모든 해역에서 공통적으로 감소하는 추세를 보인다. 특히, A해역에서 감소 추세가 현저하고, D해역에서는 감소 추세가 미미하다. 태풍이 가장 많이 발생하는 해역은 A해역(연평균 13.8개, 전체의 약 53%)이고, 그 다음은 C해역(5.6개, 약 21%), B해역(3.8개, 약 14%), D해역(3.1개, 약 12%)의 순서이다. 태풍의 세기는 A해역에서 발생하는 것이 가장 강하고(중심최저기압의 평균 951hPa), 그 다음은 C해역(970hPa), B해역(975hPa), D해역(983hPa)의 순서이다. 그리고 전 해역을 대상으로 하여 연평균 중심최저기압의 시계열 분포를 살펴보면, 태풍의 중심최저기압은 미세하게 하강하는 추세를 보인다. 이는 태풍의 세기가 서서히 강해지고 있음을 의미한다. 금번의 연구 결과는 지구 온난화에 따른 태풍의 수와 세기의 변화에 대한 여러 수치실험 결과와 일치한다.