• Title/Summary/Keyword: 13A 가스그룹

Search Result 9, Processing Time 0.028 seconds

Test Gases for Gas Burning Appliances of New Gas Group (새 가스그룹의 가스기기 시험가스)

  • Ha, Young-Cheol;Kim, Sung-Min;Lee, Chang-Eon;Choi, Kyoung-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.439-444
    • /
    • 2011
  • To determine the test gases for gas appliances of new gas group, the interrelation between gas interchangeability, including thermal efficiency, of 13A gas appliances and present 13A test gases was experimentally investigated. The test results show that the Wobbe indices in the case of incomplete combustion and the flame lifting limit gas for the new gas group are respectively 2% higher than the upper limit and 1% lower than the lower limit of the Wobbe index range. The most suitable composition of R gas is 96 mol% of methane and 4 mol% of propane; LNG could be also used as R gas. Further, analysis results showed that the hydrogen concentration of flash back limit gas could be lowered from 30 vol% to 23 vol%.

New Method for Estimating Gas Interchangeability for 13A Gas Appliances (13A 가스기기 새 가스호환성 판정법)

  • Ha, Young-Cheol;Park, Seo-Jong;Park, Won-Sic;Choi, Kyoung-Seok;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.961-967
    • /
    • 2011
  • The objective of this study was to develop a new method for estimating gas interchangeability for 13A gas appliances. The three basic principles for the development of this method are as follows: 1) to derive the secondary interchangeability factor that represents the effect of gas composition, in addition to the major interchangeability factor, i.e., Wobbe index; 2) to test every type of and each maker's domestic gas appliances that are widely used in our country, particularly including premixed gas appliances; and 3) to develop a simple estimation method. On the basis of these principles, thirty representative gas appliances were tested, and as a result, a simple two-dimensional interchangeability diagram consisting of Wobbe index and relative density was developed. Unlike conventional methods for estimating interchangeability, this method can be applied to premixed gas appliances, which have a narrow stable flame range, and the interchangeability range of this method then becomes narrower than that of the conventional methods.

Comparison of Carbon Dioxide Emission Concentration according to the Age of Agricultural Heating Machine (농업용 난방기의 사용 연식에 따른 이산화탄소 배출농도 비교)

  • Na-Eun Kim;Dae-Hyun Kim;Yean-Jung Kim;Hyeon-Tae Kim
    • Journal of Bio-Environment Control
    • /
    • v.32 no.3
    • /
    • pp.190-196
    • /
    • 2023
  • This study was carried out to collect gas emitted from agricultural heaters using kerosene and to identify the emission concentration of carbon dioxide according to the age of agricultural heating machine. As a result of the linear regression analysis, the carbon dioxide emissions according to the year of agricultural heating machine are R2 = 0.84, which follows y = 26.99x+721.98. Distributed analysis was classified into three groups according to the age of agricultural heating machine. As a result of the distributed analysis, it was 2.196×10-13, which was smaller than the 0.05 probability set for the analysis, which means that there is a difference in at least one group. As a result, the age of the agriculture machine was divided into three groups and the difference between groups was tested. A statistical analysis result was derived that there was a difference in the emission concentration of carbon dioxide according to the age of agricultural heating machine. It is thought that it can be used to investigate greenhouse gas emissions by investigating the amount of carbon dioxide generated by agricultural heaters in the agricultural field of Korea.

Analysis of computational fluid dynamics on design of nozzle for integrated cryogenic gas and MQL(minimum quantity lubrication) (극저온 가스와 MQL(minimum quantity lubrication)의 복합 분사를 위한 하이브리드 노즐 설계에 관한 전산유체역학 해석)

  • Song, Ki-Hyeok;Shin, Bong-Cheol;Yoon, Gil-Sang;Ha, Seok-Jae
    • Design & Manufacturing
    • /
    • v.13 no.3
    • /
    • pp.41-47
    • /
    • 2019
  • In conventional machining, the use of cutting fluid is essential to reduce cutting heat and to improve machining quality. However, to increase the performance of cutting fluids, various chemical components have been added. However, these chemical components during machining have a negative impact on the health of workers and cutting environment. In current machining, environment-friendly machining is conducted using MQL (minimum quantity lubrication) or cryogenic air spraying to minimize the harmful effects. In this study, the injection nozzle that can combined injecting minimum quantity lubrication(MQL) and cryogenic gas was designed and the shape optimization was performed by using computational fluid dynamics(CFD) and design of experiment(DOE). Performance verification was performed for the designed nozzle. The diameter of the sprayed fluid at a distance of 30 mm from the nozzle was analyzed to be 21 mm. It was also analyzed to lower the aerosol temperature to about 260~270K.

Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange (온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.647-657
    • /
    • 2015
  • To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.

Formation of compound layers and Wear behavior of AISI4115 steels by gaseous nitriding process (AISI4115 기계구조용 합금강의 질화 가스분위기에 따른 화합물층의 형성 및 내마모특성)

  • Kim, Taehwan;Son, Seokwon;Cho, Kyuntaek;Lee, Kee-ahn;Lee, Won-beom
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.5
    • /
    • pp.267-277
    • /
    • 2021
  • Nitriding layers developed during gaseous nitriding of AISI4115 steels for the application of steel bushing part were investigated. The compound layer thickness of about 10㎛, 0.3mm of case depth under the same conditions, and conventional nitriding, nitrocarburizing, and controlled nitriding were performed in three methods. In the controlled nitriding, KN was controlled by measuring the hydrogen partial pressure. The nitrided samples were analyzed by micro Vickers hardness test, optical microscopy and scanning electron microscopy. The phases of compound layer were identified by X-ray diffraction and electron backscatter diffraction. The controlled nitriding specimen indicated the highest surface hardness of about 860 HV0.1. The compound layer of the conventional nitriding and nitrocarburizing specimen was formed with about 46% porous layer and 𝜺 + 𝜸' phase, and about 13% porous layer and about 80% 𝜸' phase were formed on the controlled nitriding specimen. As a result of the Ball-on-disk wear test, the worn mass loss of ball performed on the surface of the controlled nitriding specimen was the largest. The controlled nitriding specimen had the highest surface hardness due to the lowest porous percentage of compound layer, which improved the wear resistance.

The Prognostic Value of Fibroblastic Foci Quantity in Patients with Usual Interstitial Pneumonia (UIP 환자에서 측정된 Fibroblastic Foci량이 예후에 미치는 영향)

  • Park, Sung-Woo;Lee, Young-Mok;Lee, June-Hyeuk;Kim, Ki-Up;Kim, Do-Jin;Uh, Soo-Taek;Kim, Yong-Hoon;Park, Choon-Sik;Kim, Hyun-Jo;Youm, Wook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.540-549
    • /
    • 2001
  • Background : Usual interstitial pneumonia (UIP) is a progressive fibrous lung disease with occasional fatal outcomes. However, the extent and rate of progression varies markedly from one patient to another. As a result, it is difficult to determine the time of the initial treatment and assess the disease activity and course. Fibroblast foci (FF) is well known to synthesize collagen actively by their myofibroblasts component. However, the prognostic value of the FF have not been evaluated in patients with VIP. Therefore this study was undertaken to determine how the number of fibroblastic foci can reflect the disease activity and progression. Methods: Twenty patients with UIP(M : F=13 : 7), who were diagnosed by a surgical lung biopsy. The number of fibroblastic foci was analyzed in terms of its correlation with the clinical manifostations, pulmonary function test, arterial blood gas analysis, and a bronchoalveolar lavage(BAL). Results : The number of fibroblastic foci did not correlate with the various lung function tests and the other clinical parameters. Interestingly, the percentage of neutrophils in the bronchoalveolar lavage fluid did correlate with the quantity of the normalized Vv of FF(r=0.60, p<0.05). The patients were divided into 2 groups, group I and II, arbitrarily, according to the value of the normalized Vv. The clinical parameters and the PIT results were not different between the two groups. In particular, the survival rate between the two groups according to the Kaplan-Meier analysis were not different. Conclusion : A large number of FF does not imply a bad prognosis in patients with UIP.

  • PDF

Effect of Heating Methods on the Oxidative Stability of Deep-fat Fried Instant Noodles in Cooking (조리시 가열방법이 유탕면의 산화안정성에 미치는 영향)

  • Chung, Soo-Yeon;Lee, Jin-Won;Han, Sung-Hee;Lee, Seog-Won;Rhee, Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.5
    • /
    • pp.500-505
    • /
    • 2007
  • The objective of this study was to investigate the effects of cooking methods (cooking apparatus and reaction level of oxygen) on the rancidity, reactive oxygen species (ROS), and furans produced while cooking deep-fired instant noodles. The sample rancidities showed a decreasing trend regardless of the cooking apparatus, as the available oxygen content in the cooking pot was reduced. In particular, soaking and then cooking using a microwave oven was found to be the most effective method to retard rancidity development. The ROS concentration after cooking had a similar trend to the rancidity. The furan concentrations of the samples significantly decreased under all cooking conditions as compared to the control, and the lowest value was 10.69 ppb for the sample cooked in a microwave oven without a cooking pot lid after soaking. The results indicate that cooking in a microwave oven with soaking was the most effective method for the oxidative stability of deep-fried instant noodles.

The Clinical Effects of Normocapnia and Hypercapnia on Cerebral Oxygen Metabolism in Cardiopulmonary Bypass (체외순환 시 뇌대사에 대한 정상 탄산분압과 고 탄산분압의 임상적 영향에 관한 비교연구)

  • 김성룡;최석철;최국렬;박상섭;최강주;윤영철;전희재;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.35 no.10
    • /
    • pp.712-723
    • /
    • 2002
  • Substantial alterations in cerebral blood flow(CBF) are known to occur during cardiopulmonary bypass(CPB). Many investigators have speculated that these changes may be responsible for both minor and major cerebral damages after CPB. More recently, these changes in CBF have been observed to be intimately related to the arterial carbon dioxide tension(Pa$CO_2$) maintained during CPB. The present study was prospectively designed to investigate the clinical effects of normocapnic and hypercapnic CPB on the cerebral oxygen metabolism in cardiac surgery Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized to either normocapnic group (Pa$CO_2$35~40 mmHg, n=18) or hypercapnic group(Pa$CO_2$, 45~55 mmHg, n=18) with moderately hypothermic nonpulsatile CPB(nasopharyngeal temperature of 29~3$0^{\circ}C$). In each patient, middle cerebral artery blood flow velocity( $V_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v) $O_2$), cerebral oxygen extraction(COE), cerebral metabolic rate for oxygen(CMR $O_2$), cerebral oxygen transport( $T_{E}$ $O_2$), $T_{E}$ $O_2$/CMR $O_2$ ratio, cerebral desaturation(internal jugular bulb blood oxygen saturation $\leq$ 50%), and arterial and jugular bulb blood gas were evaluated throughout the operation. Postoperative neuropsychologic complications were assessed in all patients. All variables were compared between the two groups. Result: VMCA(169.13 $\pm$ 8.32 vs 153.11 $\pm$8.98%), TE $O_2$(1,911.17$\pm$250.14 vs 1,757.40$\pm$249.56), $T_{E}$ $O_2$,/CMR $O_2$ ratio(287.38$\pm$28.051 vs 246.77$\pm$25.84), $O_2$ tension in internal jugular bulb (41.66$\pm$9.19 vs 31.50$\pm$6.09 mmHg), and $O_2$saturation in internal jugular bulb(68.97$\pm$10.96 vs 58.12$\pm$12.11%) during CPB were significantly lower in normocapnic group(p=0.03), whereas hypercapnic group had lower C(a-v) $O_2$(3.9$\pm$0.3 vs 4.9$\pm$0.3 mL/dL), COE(0.3$\pm$0.03 vs 0.4$\pm$0.03), CMR $O_2$(5.8 $\pm$0.5 vs 6.8$\pm$0.6), and arterial blood pH(7.36$\pm$0.09 vs 7.46$\pm$0.07, p=0.04) during CPB. Hypercapnic group had lower incidence of cerebral desaturation than normocapnic group(3 vs 9 patients, p=0.03). Duration of the neuropsychologic complication(delirium) were shorter in hypercapnic group than in normocapnic group(36 vs 60 hrs, p=0.009). Conclusion: These findings suggest that hypercapnic CPB may have salutary effects on the cerebral oxygen metabolism and postoperative neurologic outcomes in cardiac surgery.surgery.