• Title/Summary/Keyword: 12m × 3m 모듈

Search Result 61, Processing Time 0.023 seconds

Highly Efficient Biogas Upgrading Process Using Polysulfone Hollow Fiber Membrane at Low Temperature (폴리술폰 중공사막을 이용한 바이오가스 고순도화 고효율 저온 분리 공정)

  • Kim, Se Jong;Han, Sang Hoon;Yim, Jin Hyuk;Lee, Chung Seop;Chang, Won Seok;Kim, Gill Jung;Ha, Seong Yong
    • Membrane Journal
    • /
    • v.32 no.2
    • /
    • pp.140-149
    • /
    • 2022
  • In this study, the conditions of low temperature and high pressure of biogas upgrading process using polysulfone membrane have been designed and tested to achieve the high recovery and efficiency corresponding to those of the highly selective polymeric materials. Polysulfone hollow fiber membrane with 4-component dope solution was spun via non-solvent induced phase separation. The hollow fiber membrane was mounted into a 1.5 inch housing. The effective area was 1.6 m2, and its performance was examined in various operation temperatures and pressures. CO2 and CH4 permeances were 412 and 12.7 GPU at 20℃, and 280 and 3.6 GPU at -20℃, respectively, while the CO2/CH4 selectivity increased from 32.4 to 77.8. Single gas test was followed by the mixed gas experiments using single-stage and double stage where the membrane area ratio varied from 1:1 to 1:3. At the single-stage, CH4 purity increased and the recovery decreased as the stage-cut increased. At the double stage, the area ratio of 1:3 showed the higher CH4 recovery as decreasing the operation temperature at the same purity of CH4 97%. Finally, polysulfone hollow fiber membranes have yielded of both CH4 purity and recovery of 97% at -20℃ and 16 barg.

Predictions of the Cooling Performance on an Air-Cooled EV Battery System According to the Air Flow Passage Shape (공기 유로 형상에 따른 공랭식 전기자동차 배터리 시스템의 냉각 성능 예측)

  • Jeong, Seok Hoon;Suh, Hyun Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.12
    • /
    • pp.801-807
    • /
    • 2016
  • This paper aims to compare and study the cooling performance of a battery system in accordance with the inlet and outlet geometry of the air passage in an EV. The arrangement and the heat source of the battery module were fixed, and the inlet/outlet area and its geometry were varied with the analysis of the cooling performance. The results of this study provide suggestions for the air flow stream line inside of a battery, the velocity field, and the temperature distributions. It was confirmed that the volume flow rate of air should be over $400m^3/h$, in order to satisfy conditions under $50^{\circ}C$, which is the limit condition for stable operation. It was also revealed that the diffuser outlet geometry can improve the cooling performance of battery system.

Performance Analysis of Photovoltaic System for Greenhouse (태양광 발전시스템의 발전 성능 분석)

  • Kwon, Sun-Ju;Min, Young-Bong;Choi, Jin-Sik;Yoon, Yong-Cheol
    • Journal of agriculture & life science
    • /
    • v.46 no.5
    • /
    • pp.143-152
    • /
    • 2012
  • This study was performed to reduce the operating cost of a greenhouse by securing electric energy required for greenhouse operation. Therefore, it experimentally reviewed the performance analysis of photovoltaic system in terms of maximum amount of generated electric power based on the amount of horizontal solar radiation during daytime. That is to say, the maximum solar radiation at 300, 400, 500, 600, 700, 800 and 900 W. $m^{-2}$, respectively. The amount of momentary electric power of the photovoltaic system at any was about 970 W and we found that the momentary efficiency of the photovoltaic system that was used for this experiment was 97%. In the case of this system, we found that electric power will be generated when amount of horizontal solar radiation is more than 200 W. $m^{-2}$, at minimum. If the amount of horizontal solar radiation is increased, the maximum power generation is also increased. At that time, the maximum efficiencies were 30, 78, 86 and 90%, respectively. However, when the amount of insolation was about 800 W. $m^{-2}$, the maximum power generation tended to be lower than 700 W. $m^{-2}$. The efficiency which caused the maximum electric power was decreased to less than 97% of the momentary generated electric power. When the total amounts of horizontal solar radiation per day were 3.24, 8.10, 10, 90, 12.70, 14.33, 19.53 and $21.48MJ{\cdot}m^{-2}$ respectively, the total amounts of power energy were 0.03, 0.40, 3.60, 4.37, 4.71, 4.70 and 4.91 kWh. And it represented that the total amounts of power energy were either decreased or increased a bit on the border between some solar radiations. The temperature at the back of the array tended to be higher than the temperature at the front but it demonstrated an increased when the amount of solar radiation increased. In the case of this system, the performance of the module in terms of degradation has not been shown yet.

Development of UV-IR Camera using IR Module and Improved UV Filter Transmittance (투과율 향상 UV 필터와 IR 모듈을 이용한 자외선-적외선(UV-IR) 카메라 개발)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il;Kim, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.37-43
    • /
    • 2012
  • UV-IR diagnostic technology is being used for predictive maintenance of high voltage equipment together with IR-thermography and ultrasonic devices. In this paper, the UV-IR camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. UV-IR camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. In a distance of 5m with the UV-IR it is possible to detect partial discharge with a PD level of 2.5 pC and a RIV(Radio Influence Voltage) level of $3.6dB{\mu}V$.

Data Mining Approaches for DDoS Attack Detection (분산 서비스거부 공격 탐지를 위한 데이터 마이닝 기법)

  • Kim, Mi-Hui;Na, Hyun-Jung;Chae, Ki-Joon;Bang, Hyo-Chan;Na, Jung-Chan
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.3
    • /
    • pp.279-290
    • /
    • 2005
  • Recently, as the serious damage caused by DDoS attacks increases, the rapid detection and the proper response mechanisms are urgent. However, existing security mechanisms do not effectively defend against these attacks, or the defense capability of some mechanisms is only limited to specific DDoS attacks. In this paper, we propose a detection architecture against DDoS attack using data mining technology that can classify the latest types of DDoS attack, and can detect the modification of existing attacks as well as the novel attacks. This architecture consists of a Misuse Detection Module modeling to classify the existing attacks, and an Anomaly Detection Module modeling to detect the novel attacks. And it utilizes the off-line generated models in order to detect the DDoS attack using the real-time traffic. We gathered the NetFlow data generated at an access router of our network in order to model the real network traffic and test it. The NetFlow provides the useful flow-based statistical information without tremendous preprocessing. Also, we mounted the well-known DDoS attack tools to gather the attack traffic. And then, our experimental results show that our approach can provide the outstanding performance against existing attacks, and provide the possibility of detection against the novel attack.

Graft-taking and Growth Characteristics of Grafted Cucumber(Cucumis sativus L.) Seedlings as Affected by Light Quality and Blink Cycle of LED Modules (LED 모듈의 광질 및 점멸주기에 따른 오이접목묘의 활착 및 생장 특성)

  • Kim, Hyeong Gon;Choi, Yu Hwa;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.2
    • /
    • pp.143-149
    • /
    • 2019
  • This study was conducted to investigate the graft-taking and growth of grafted cucumber seedlings as affected by light quality and blink cycle of LED modules. Four light quality treatments, namely blue, red, blue+red, white LED and four blink cycle levels of 5s/5s, 7s/3s, 9s/1s and control were provided to investigate the effect of lighting quality and blink cycle on the graft-taking and growth of grafted cucumber seedlings. Photoperiod for the control was 12/12 h. Photosynthetic photon flux, air temperature, and relative humidity for healing were maintained at $100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, $25^{\circ}C$, and 90%, respectively. There was no significant difference in graft-taking of grafted cucumber seedlings according to light quality except the blue LED with the blink cycle of 5s/5s. Regardless of the blink cycle, there was no significant difference in graft-taking of cucumber seedlings healed under red, blue+red, and white LED modules. These results implied that the effects of light quality and blink cycle on the graft-taking were not significant. Differences in the leaf length, leaf area, and fresh weight of cucumber seedlings healed blue or red LED with the blink cycle of 9s/1s were found to be significant. There was no significant effect of the blink cycle on the growth of cucumber seedlings healed under white LED modules. The prices of white LED are gradually falling due to increased demand. Considering the manufacturing unit price of white LED modules, the cost savings of 10-15% are expected as compared to the conventional blue/red LED modules. Therefore, it was concluded that the use of white LED modules will be economical as an artificial lighting sources for healing of grafted seedlings.

Clonal Growth and Shoot Modules Dynamics of Phragmites longivalvis in a Reclaimed Land (간척지 갈대의 영양생장과 지상부 모듈의 개체군 동태)

  • Choung, Yeon-Sook;Kim, Joon-Ho
    • The Korean Journal of Ecology
    • /
    • v.12 no.3
    • /
    • pp.171-182
    • /
    • 1989
  • The structure, clonal grwoth, shoot modules dynamics and rhizome respiratory rate of the Phragmites longivalvis circular patch were studied in a 15-year-old reclaimed land on Mado of the western Korea for two growing seasons. Clonal growth by P. longivalvis resulted in subpopulations of shoot modules which may be separated into pioneer, mature and senile growth phase. The radial growth of circular patch was 208 cm per a year. The shoot phytomass, shoot height and spike frequency were the lowest in the senile phase, and were the highest in the mature phase. The maximum shoot phytomass of pioneer, mature and senile phase in August was 347, 536 and 195g/$\m^2$ for the first year, and 609, 748 and 248g/$\m^2$ for the second year, respectively. The birth rates of shoot modules were the highest during the early spring. Of all modules, the percemtage of spring cohort of pioneer, mature and senile growth phase were 52, 82 and 70% for the first year, and 83, 88 and 85% for the second year, respectively. The flowering shoots were only derived from spring cohorts. The death rates of shoot modules of the pioneer and mature phase were the highest in October. The module is an annual semelparous plant though the genet is a perennial iteroparous plant. Their survivorship curve was negatively (Deevey type I). The density of shoot modules of the pioneer, mature and senile growth phase increased as much as 4.0, 1.6 and 2.3 times for one year, respectively. The respiratory rate was the highest in the lowest in the senile growth phase.

  • PDF

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

THERMAL-FLUID PERFORMANCE ANALYSIS OF COMPACT HEAT EXCHANGERS HAVING A PERIODIC CHANNEL CONFIGURATION (주기적인 채널형상을 갖는 고밀도 열교환기의 열유동 성능해석)

  • Kim, M.H.;Lee, W.J.
    • Journal of computational fluids engineering
    • /
    • v.12 no.3
    • /
    • pp.47-54
    • /
    • 2007
  • A periodic CFD approach for the performance analysis of compact high temperature heat exchangers is introduced and applied to selected benchmark problems, which are a fully developed 2D laminar heat transfer, a conjugate heat transfer between parallel plates which have exact solutions, and a heat transfer in a real high temperature heat exchanger module. The results for the 2D laminar heat transfer and the 2D conjugate heat transfer showed a very good agreement with the exact solutions. For the high temperature heat exchanger module, the pressure drops were predicted well but some difference was observed in the temperature parameters when compared to the full channel CFD analysis due to assumptions introduced into the periodic approach. Considering its assumptions and simplicities, however, the results showed that the periodic approach provides physically reasonable results and it is sufficient to predict the performance of a heat exchanger within an engineering margin and with much less CPU time than the case of a full channel analysis.

A 6-Bit MMIC Digital Attenuator with High Attenuation Accuracy and Small Phase Variation for X-band TR Module Applications (X-band 송수신 모듈을 위한 높은 감쇠 정확도와 작은 위상 변동을 가진 6 비트 MMIC 디지털 감쇠기)

  • Ju, In-Kwon;Yom, In-Bok;Lee, Jeong-Won;Lee, Soo-Ho;Ahn, Chang-Soo;Kim, Sun-Joo;Park, Dong-Un;Oh, Seung-Hyeup
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.452-459
    • /
    • 2009
  • A 6-bit MMIC digital attenuator applicable to X-band TR module has been developed by using $0.5{\mu}m$GaAs pHEMT processes. The Switched-T attenuator scheme and the switched-path attenuator scheme were adopted to obtain low insertion loss and small phase variation, respectively. Resistors and transmission lines are optimized to achieve the digital attenuator with high attenuation accuracy and small phase variation. The digital attenuator has RMS error of 0.4dB, resolution of 0.5dB and dynamic range of 31.5dB. The measurement results show that in-out VSWRs are less than 1.5, phase variation is from -7 to +2 degrees and IIP3 is 36.5dBm.