• Title/Summary/Keyword: 120Hz

Search Result 483, Processing Time 0.025 seconds

In situ acoustic characteristics of the large jellyfish Nemopilema nomurai in the East China Sea (동중국해에서 노무라입깃해파리의 in situ 음향산란특성)

  • Yoon, Eun-A;Hwang, Doo-Jin;Shin, Hyeong-Ho;Gwa, Du-Seong;Cha, Cheol-Pyo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.3
    • /
    • pp.256-268
    • /
    • 2012
  • The Nemopilema nomurai is a large jellyfish attaining a weight of 200 kg and bell diameter of 2 m when fully grown. To prevent damage to this species, this study determined the acoustic characteristics of N. nomurai using frequencies 38 and 120 kHz. The CPUE of N. nomurai and the averaged SV of 38 and 120 kHz had a lower (+) correlation coefficient and relationship at 120 kHz (R=0.51) than at 38 kHz (R=0.15) was significant. In addition, the averaged SV at 120 kHz was higher than at 38 kHz. The ${\Delta}MVBS_{120-38}$ in section catches ${\geq}97.8%$ wet mass of N. nomurai was -2.2 to 5.6 dB. The ${\Delta}TS_{120-38}$ in situ TS was extracted in sections catches of only N. nomurai by FMT. It was found that the averaged in situ ${\Delta}TS_{120-38}$ were at 0.6 and 0.1 dB. Furthermore, it results showed a close relationship between the bell diameter and TS of N. nomurai. The dominance of smaller N. nomurai (11.0~20.0 cm bell diameter in the air) corresponded to a similar proportion of low TS values (-69.0~-65.0 dB). A small number of larger N. nomurai (25.0~38.0 cm bell diameter in the air) were collected, in which TS values were the highest (-62.0~-58.0 dB).

Novel Impulsive Driving Schemes for 120Hz LCD Panels

  • Nam, Hyoung-Sik;Oh, Jae-Ho;Shin, Byung-Hyuk;Oh, Kwan-Young;Berkeley, Brian H.;Kim, Nam-Deog;Kim, Sang-Soo
    • Journal of Information Display
    • /
    • v.9 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Two new impulsive driving technologies for 120Hz liquid crystal display (LCD) panels are proposed to improve moving picture quality. One technology generates the dark frame using an adder and a shifter simply without using any look up tables (LUTs). It results in a cost effective impulsive scheme with motion picture quality comparable to that of high speed driving. The other is a backlight flashing method designed to avoid ghost images. The issue of ghost images caused by the slow response time of liquid crystal (LC) is solved by means of 120Hz overdriving and 120Hz backlight flashing. Using the perceived blur edge time (PBET) metric, measured moving picture response time (MPRT) values were 10.8ms and 4.4ms, respectively, while that of 120Hz high speed driving was 10.1ms.

Target strength of juvenile Antarctic silverfish (Pleuragramma antarcticum) (남극 은암치(Pleuragramma antarcticum) 치어의 음향산란특성)

  • Sara, LEE;Wooseok, OH;Hyoung Sul, LA;Wuju, SON;Jeong-Hoon, KIM;Kyounghoon, LEE
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.4
    • /
    • pp.345-351
    • /
    • 2022
  • In this study, the target strength for multi-frequency (38 kHz, 120 kHz, 200 kHz) of juvenile silverfish (Pleuragramma antarcticum) was estimated using by the KRM (Kirchhoff-ray mode) model. The body shape of the silverfish was described by a picture and the body length of nine individuals ranged in 1.8 cm to 8.8 cm. The maximum TScm according to the total length for the constant term (b20) was -92.93 dB at 38 kHz, -86.63 dB at 120 kHz, and -85.89 dB at 200 kHz, respectively. The averaged TScm according to total length for the constant term (b20) was -100.0 dB at 38 kHz, -93.0 dB at 120 kHz, and -106.9 dB at 200 kHz, respectively.

Power Factor Correction LED driver with small 120Hz current ripple (낮은 120Hz 출력 전류 리플을 갖는 역률개선 LED 구동 회로)

  • Park, Hyun-Seo;Park, Jae-sung;Oh, Dong-sung;Hong, Sung-Soo;Han, Sang-Kyoo
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.382-383
    • /
    • 2011
  • 본 논문에서는 출력 LED 전류의 120Hz 저주파 리플 저감을 위한 새로운 방식의 역률개선 LED 구동 회로를 제안한다. 제안된 회로는 역률개선용 플라이백 컨버터의 출력이 LED 구동을 위한 부스트 컨버터의 입력이 되는 구조로 높은 역률 보상과 출력 LED 전류의 120Hz 리플 저감이 가능하고, 기존에 비해 저 내압 및 저 용량의 부피가 작은 링크 캐패시터를 사용 할 수 있는 장점이 있다. 또한 제안 회로는 전력평형 만족을 위해 하나의 PWM IC 만으로 플라이백 컨버터와 부스트 컨버터를 각각 DCM 및 BCM모드로 제어하여 스위치 및 다이오드의 전류 스트레스 저감이 가능한 장점이 있다. 최종적으로 시작품을 제작하여 고찰된 실험결과를 제시하여, 제안 회로의 우수성과 이론적 분석의 타당성을 검증한다.

  • PDF

A Study on Pitch Perception of Normal Korean (한국 성인 음성의 음도인식에 관한 연구)

  • Jeong, Ok-Ran;Kim, Hyung-Soon;Kim, Young-Tae;Sub, Jang-Su
    • Speech Sciences
    • /
    • v.1
    • /
    • pp.315-323
    • /
    • 1997
  • This study attempts to determine the fundamental frequency level of male and female voices that Koreans perceive as normal. Seventy-three college students majoring in Speech Pathology participated in the study on a voluntary basis. The subjects listened to a male voice with fundamental frequency of 60 Hz, 80 Hz, 100 Hz, 120 Hz, 140 Hz, 160 Hz, 180 Hz, and 200 Hz, and a female voice with fundamental frequency of 140 Hz, 160 Hz, 180 Hz, 200 Hz, 220 Hz, 240 Hz, 260 Hz, and 280 Hz. The PSOLA (Pitch Synchronous Overlap). method and harmonic modeling method of speech signal were used to change pitch in the 20 Hz interval. The voices were presented in a random order to prevent listener bias. The results were as follows; Firstly, $46.6\%$ judged male voice with 120 Hz as normal, and $19.2\%$ judged 140 Hz as normal, and another $19.2\%$ judged 160 Hz as normal. Secondly, $50.7\%$ perceived female voice with 220 Hz as normal, and $32.9\%\;and\;30.1\%$ responded to 200 Hz and 240 Hz, respectively. The problems and recommendations for a future investigation are discussed.

  • PDF

Investigations of the Potential Fisheries Resources in the Southern Waters of Korea - Hydroacoustic Investigations of Abundance and Distributing of Fish - (한국 남해안의 잠재어업자원 조사연구 - 어업생물자원의 음향학적 조사 -)

  • Lee, Dae-Jae;Kim, Jin-Geon;Sin, Hyeong-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.3
    • /
    • pp.259-273
    • /
    • 1998
  • The hydroacoustic surveys to provide the essential information for the assessment, management and utilization of fishery resources in the southern waters of Korea were carried out during five research cruises between October 1996 and October 1997 by the training ship KAYA of Pukyong National University. These hydroacoustic investigations were designed to obtain more precise estimates of the geographic distribution, absolute abundance and biological characteristics of the fishery resources, and the vertically integrated densities of fish in terms of volume backscattering strength(SV) by survey region and depth bins, such as the entire water column and the 0~ 10 m from bottom fraction, were measured separately. Hydroacoustic data were collected by using a Simrad EK 500 Scientific echo sounder operating at two frequencies of 38kHz and 120kHz and the data stored in field were later processed on a HP PC using a Simrad EP 500 echo integration and target strength analysis system. The biological compositions of echo signal were identified and sampled using a demersal trawl during daylight hours. The mean target strength to scale the echo integration data for hydroacoustic surveys was derived from the relationship between the SV and the weight of trawl catch per unit volume of the water column sampled by demersal trawls. The results obtained can be summarized as follow : 1. The mean volume backscattering strength for the entire water column in the southern waters of Korea between 1996 and 1997 were -67.2 dB and -70.9 dB at two frequencies of 38 kHz and 120 kHz , respectively, and for the bottom layer of the 0-10 m from bottom friction were -68.8 dB, -70.2 dB, respectively. That is, the volume backscattering strength for the entire water column at low frequency was higher than that at high frequency. 2. The relationship between the mean backscattering strength (〈SV〉, dB) for the depth strata of trawl hauls and the weight (C, kg/m3) per cubic meter of the catch sampled by bottom trawling in the southern waters of Korea in January and July 1997 were expressed by the following equations: 38 kHz : 〈SV〉= -28.2 + 10 log(C), 120 kHz : 〈SV〉= -32.4 + 10 log(C). The mean weight -normalized target strengths derived from these equitions were -28.2 dB/ kg, -32.4 dB/ kg at 38 kHz and 120 kHz , respectively. That is, the mean weight -normalized target strength at 38 kHz was 4.2 dB higher than that at 120 kHz. 3. The distribution density of fish in terms of biomass per unit volume in the southern waters of Korea were estimated to be 125.9 $\times$ 10-6 kg/m3 and 141.3 $\times$ 10-6 kg/m3 at 38 kHz and 120 kHz , respectively.

  • PDF

Target strength estimation by tilt angle and size dependence of rockfish (Sebastes schlegeli) using ex-situ and acoustic scattering model (현수법과 모델을 이용한 조피볼락의 유영자세각과 체장에 따른 음향 후방산란강도)

  • YOON, Euna;KIM, Kiseon;LEE, Intae;JO, Hyeon-Jeong;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.2
    • /
    • pp.152-159
    • /
    • 2017
  • Rockfish was a commercially important fish specie in marine ranching areas in Korea. To estimate density and biomass of rockfish using acoustic method, target strength (TS) information is required on the species. This study measured TS dependence on tilt angle and size on 14 live rockfish individuals at 38, 70, and, 120 kHz by ex-situ measurement (tethered method) and acoustic scattering model (Krichhoff ray mode, KRM). The swimbladdered angle ranged from 18 to $30^{\circ}$ ($mean{\pm}s.d.=26{\pm}4^{\circ}$). The mean TS for all individuals was highest -35.9 dB of tilt angle $-17^{\circ}$ at 38 kHz, -35.4 dB of tilt angle $-25^{\circ}$ at 70 kHz, and -34.9 dB of tilt angle $-22^{\circ}$ at 120 kHz. The ex-situ TS-total length (TL, cm) relationships were $TS_{38kHz}=20log_{10}(TL)-67.1$, $TS_{70kHz}=20log_{10}(TL)-68.6$, and $TS_{120kHz}=20log_{10}(TL)-69.9$, respectively. The model TS-total length (TL, cm) relationships were $TS_{38kHz}=20log_{10}(TL)-66.4$, $TS_{70kHz}=20log_{10}(TL)-67.0$, $TS_{120kHz}=20log_{10}(TL)-67.0$. The two measurements between the ex-situ TS and KRM model for TS-tilt angle and fish size were found to be significantly correlated.

The Effects of 120 Hz High Frequency Electroacupuncture on the Gastric Mucosa in Cold-Restraint Stressed Rats (고빈도 120 Hz 전침이 Cold-Restraint 스트레스 유발 흰쥐의 위점막에 미치는 영향(影響))

  • Jo, Mee-Hyeong;Ahn, Chang-Beohm;Song, Choon-Ho;Yoon, Hyoun-Min;Kim, Cheol-Hong;Jang, Kyung-Jeon
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.101-115
    • /
    • 2004
  • Objective : The present studies investigated the effects of 120 Hz high frequency electroacupuncture (EA) on the stress-induced stomach dysfunction in relation to its effect on the level of stress hormones and gastric mucosal damages. The gastric mucosal injury was induced by cold-restraint stress and two acupoints corresponding to Zusanli and Sanyinjiao in man were used. Methods : Cold-restraint stress produced typical gastric lesions in all rats of the stressed groups, but the number of ulcers as well as the mean ulcer diameter were reduced by 120 Hz EA pre-treatment. Results : The degranulation value of gastric mast cell was significantly higher in cold-restrained rats than in control ones. However, with the significant reduction of degranulation values of gastric mast cells in EA pre-treated rats compared with cold-restrained rats. Cold-restarint stress induced an elevated mRNA expression of pro-inflammatory gene such as cyclooxygenases-2 and tumor necrosis factor $(TNF)-{\alpha}$, but these expression were down-regulated in EA pre-treated rats. Immunohistochemical analysis showed that while the $inhibitory-{\kappa}B{\alpha}$ and $TNF-{\alpha}$ immunorection in the surface epithelium of the stomach tended to increase, both reactions in the EA pre-treated rats showed similar pattern as observed in controls. Conclusion : These results suggest that 120 Hz EA may act as a therapeutical means for gastric mucosal damages through an activation of pituitary adrenal system. It could be concluded that 120 Hz high frequency electroaucupuncture affords a good protective potential against stress-induced gastrointestinal dysfunction.

  • PDF

The Effects of 120Hz High Frequency Electroacupuncture on the Cold-Restraint-Induced Gastric Mucosal Damages (Cold-Restraint 스트레스 유발 위점막손상에 미치는 고빈도 120Hz 전침의 효과)

  • Jo, Mee-hyeong;Choi, Byung-tae;Jang, Kyung-jeon
    • Journal of Acupuncture Research
    • /
    • v.20 no.3
    • /
    • pp.177-193
    • /
    • 2003
  • Objective : The present studies investigated the effects of 120Hz high frequency electroacupunctue(EA) on the stress-induced stomach dysfunction in relation to its effect on the level of stress hormone and gastric mucosal damages. The gastric mucosal injury was induced by cold-restraint stress and two acupoints corresponding to Zusanli and Sanyinjiao in man were used. Methods: Cold-restraint stress produced typical gastric lesions in all rats of the stressed groups, but he number of ulcers as well as the mean ulcer diameter were reduced by 120 Hz EA pre-treatment. The cold-restraint stress also induced an increase in catecholamine response involving epinephrine, norepinephrine and dopamine, but an slight decline were observed in EA pre-treated rats compared with cold-restrained rats. Results: The degranulation value of gastric mast cell was significantly higher in cold-restrained rats than in control ones. However, with the significant reduction of degranulation values of gastric mast cells in EA pre-treated rats compared with cold-restrained ones, $PGE_2$ content in the gastric mucosa of EA pre-treated rats was also different from that observed in cold-restrained rats. Cold-restraint stress induced an elevated mRNA expression of pro-inflammatory gene such as cyclooxygenases-2 and tumor necrosis factor(TNF)-${\alpha}$, but these expression were down-regulated in EA pre-treated rats. Immunohistochemecal analysis showed that while the inhibitory-${\kappa}B{\alpha}$ an TNF-${\alpha}$ immunoreaction in the surface epithelium of the stomach tended to increase, both reactions in the EA pre-treated rats showed similar pattern as observed in controls. Conclusions : These results suggest that 120 Hz EA may act as a therapeutical means for gastric mucosal damages through a activation of pituitary adrenal system. it could be concluded that 120 hz high frequency electroacupuncture affords a good protective potential against stress-induce gastrointestinal dysfunction.

  • PDF

Target Strength Measurements of Live Golden Cuttlefish Sepia esculenta at 70 and 120 kHz

  • Lee, Dae-Jae;Demer, David A.
    • Fisheries and Aquatic Sciences
    • /
    • v.17 no.3
    • /
    • pp.361-367
    • /
    • 2014
  • Cuttlefish Sepia esculenta are commercially important in Korea. Assessments of their biomass currently depend on fishery-landings data, which may be biased. Towards fishery-independent acoustic surveys of cuttlefish, target strength (TS) measurements at 70 and 120 kHz were made of 23 live cuttlefish, in early May 2010. The fish were caught by traps in the inshore waters around Geojedo, Korea. The TS were measured using split-beam echosounders (Simrad ES60 and EY500, respectively). The cuttlefish mantle lengths (L) ranged from 15.6 to 23.5 cm (mean L=17.8 cm) and their masses (W) ranged from 335 to 1020 g (mean W=556.1 g). Their mean TS values at 70 and 120 kHz were -33.01 dB (std=1.39 dB) and -31.76 dB (std=2.15 dB), respectively. The mean TS at 70 kHz was 0.17 dB higher than the TS-length relationship resulting from a least-squares fit to the data ($TS=24.67{\log}_{10}L(cm)-64.03$, $r^2$ = 0.52, N=23). The mean TS at 120 kHz was 0.45 dB higher than the fitted TS-length relationship ($TS=40.59{\log}_{10}L(cm)-82.96$, $r^2$ = 0.58, N=23). The differences between the mean TS values and an equation regressed from all of the TS measurements at both frequencies ($TS=24.92{\log}_{10}L(cm)-4.92{\log}_{10}{\lambda}(m)-22.82$, $r^2$ = 0.86, N=46) was 0.22 dB at 70 kHz and 0.31 dB at 120 kHz, respectively.