• Title/Summary/Keyword: 120 Hz

Search Result 488, Processing Time 0.03 seconds

Study on Fiber Laser Annealing of p-a-Si:H Deposition Layer for the Fabrication of Interdigitated Back Contact Solar Cells (IBC형 태양전지 제작을 위한 p-a-Si:H 증착층의 파이버 레이저 가공에 관한 연구)

  • Kim, Sung-Chul;Lee, Young-Seok;Han, Kyu-Min;Moon, In-Yong;Kwon, Tae-Young;Kyung, Do-Hyun;Kim, Young-Kuk;Heo, Jong-Kyu;Yoon, Ki-Chan;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.430-430
    • /
    • 2008
  • Using multi plasma enhanced chemical vapor deposition system (Multi-PECVD), p-a-Si:H deposition layer as a $p^+$ region which was annealed by laser (Q-switched fiber laser, $\lambda$ = 1064 nm) on an n-type single crystalline Si (100) plane circle wafer was prepared as new doping method for single crystalline interdigitated back contact (IBC) solar cells. As lots of earlier studies implemented, most cases dealt with the excimer (excited dimer) laserannealing or crystallization of boron with the ultraviolet wavelength range and $10^{-9}$ sec pulse duration. In this study, the Q-switched fiber laser which has higher power, longer wavelength of infrared range ($\lambda$ = 1064 nm) and longer pulse duration of $10^{-8}$ sec than excimer laser was introduced for uniformly deposited p-a-Si:H layer to be annealed and to make sheet resistance expectable as an important process for IBC solar cell $p^+$ layer on a polished n-type Si circle wafer. A $525{\mu}m$ thick n-type Si semiconductor circle wafer of (100) plane which was dipped in a buffered hydrofluoric acid solution for 30 seconds was mounted on the Multi-PECVD system for p-a-Si:H deposition layer with the ratio of $SiH_4:H_2:B_2H_6$ = 30:120:30, at $200^{\circ}C$, 50 W power, 0.2 Torr pressure for 20 minutes. 15 mm $\times$ 15 mm size laser cut samples were annealed by fiber laser with different sets of power levels and frequencies. By comparing the results of lifetime measurement and sheet resistance relation, the laser condition set of 50 mm/s of mark speed, 160 kHz of period, 21 % of power level with continuous wave mode of scanner lens showed the features of small difference of lifetime and lowering sheet resistance than before the fiber laser treatment with not much surface damages. Diode level device was made to confirm these experimental results by measuring C-V, I-V characteristics. Uniform and expectable boron doped layer can play an important role to predict the efficiency during the fabricating process of IBC solar cells.

  • PDF

Acoustic Estimate of the Krill (Euphausia superba) Density between South Shetland Islands and South Orkney Islands, Antarctica, During 2002/2003 Austral Summer (음향 조사에 의한 2002/2003 하계 시기의 남극 남쉐틀랜드 군도와 남오크니섬 사이의 크릴 밀도)

  • Kang, Don-Hyung;Shin, Hyoung-Chul;Lee, Yoon-Ho;Kim, Yong-Sin;Kim, Su-Am
    • Ocean and Polar Research
    • /
    • v.27 no.1
    • /
    • pp.75-86
    • /
    • 2005
  • Acoustic survey for density and biomass estimate of Antarctic krill, Euphausia superba, was conducted in the large area between South Shetland Islands and South Orkney Islands, during November 30-December 30, 2002. Considering oceanographic and geographic properties, the study area was divided into six sub-regions. Acoustic system and frequency used in the survey were quantitative echo sounder (Simrad Ek 500) and 38, 120-kHz split beam transducers. In order to discriminate krill aggregations in all acoustic signal, difference of mean volume backscattering strength $({\Delta}MVBS)$ method of the two frequencies was introduced. Averaged krill density for the overall surveyed area was $23.5g/m^2$, and spatially averaged estimates of krill density were $44.9g/m^2$ (north of the South Shetland Islands), $30.3g/m^2$ (Bransfield Strait), $11.3g/m^2$ (near the Elephant Island), $13.6g/m^2$ (north of the Elephant Island), $18.1g/m^2$(between Elephant Island and South Orkney Islands) and $21.7g/m^2$(northwest of the South Orkney Islands) at each sub-area. In the two sub-regions with surveyed area, estimated krill biomass in the north of the Elephant Island was 0.315 million tones with a CV of 18.35% $(6,766mile^2)$, and between Elephant Island and South Orkey Islands was 1.26 million tones with a CV of 9.45% $(20,299mile^2)$. As a whole, the krill density in the early summer season was low level, comparing with that of January-February. This suggested that major krill swarms in the around South Shetland Islands were reached in the mid-summer seasons from western part of the Antarctic Peninsula, and the low krill density also affects the density variation of the krill between Elephant Island and South Orkney Islands.

Development of welding process to rootpass for U-Groove without gap in pipe 1GR butt welding (파이프 1G 회전 맞대기 용접에서 갭 없는 U-그루브의 루트패스 용접공정 개발)

  • Son, Chang-Hui;Kim, Nam-Gyu;Cho, Sang-Myeong
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.40-40
    • /
    • 2010
  • 산업현장에서는 파이프 또는 탱크류의 1GR용접에서 안정적인 이면비드를 가지는 루트패스 용접을 위해 2~3mm의 루트갭을 띄우고 용접봉 또는 필러와이어를 사용하는 TIG용접을 주로 한다. TIG용접은 고품질의 이면비드가 얻어지며, 용접인자의 제어가 쉽다는 장점이 있어 루트패스 용접에 많이 사용되고 있지만, 루트갭을 띄우면 이면비드는 잘 얻어지지만 용착금속량이 많아지게 되어 제작원가가 상승되고, 또한 소모성 와이어를 사용하는 GMAW에 비해 생산성이 낮다. 따라서, 안정적인 이면비드를 가지면서 생산성이 높은 1GR GMAW 루트패스 용접공정의 개발이 요구되지만, 이 경우도 루트갭이 2~3mm로 정해져 있으면 Fit-up공정에서 공수가 많이 필요하므로 근본적으로 루트갭이 없는 그루브에 대한 루트패스 용접이 더 바람직하다. 본 연구에서는 루트면 2.7mm를 가지는 U-그루브의 갭 없는 루트패스 용접에서 안정적인 이면비드가 형성되는 조건을 검토하기 위해 2.7t의 평판에 대하여 경사상진 각을 주고 기초 실험 후, U-그루브 맞대기 용접 실험을 진행하였다. 이 때, 경사상진 각은 용융금속이 중력으로 인해 아크 후방으로 밀리게 되고, 그로 인해 아크가 모재에 직접 닿게 되어 용입이 더 깊게되므로, 이면비드의 형성에 더 유리하다. 두께 2.7t의 연강 시편 2개를 갭 없는 I-그루브 맞대기 이음에서 Ǿ1.2 연강 솔리드 와이어를 사용하여 GMAW용접을 실시하였고, 용접전류, 용접속도, 경사상진 각, 위빙 폭, 위빙 주파수를 변경하여 각 조건에 대한 이면비드를 관찰하였다. 그 결과 경사상진 각 $25^{\circ}$, 전류 200A, 위빙폭 3mm, 위빙주파수 3Hz의 조건에서 안정적인 이면비드를 얻을 수 있었다. 또한, 현장에서 Fit-up중 발생할 수 있는 루트갭의 문제에 대하여 루트갭 1.2mm의 I-그루브 맞대기 용접에서 경사상진 각, 위빙 폭, 위빙 주파수는 갭 없이 실시한 실험에서 얻어진 가장 안정적인 결과를 사용하였고, 용접 전류, 용접 속도를 변경하여 이면비드를 관찰하였다, 그 결과 갭이 없을 때보다 약 80A 낮은 전류 조건인 120A에서 안정적인 이면비드를 얻을 수 있었다. 앞선 실험들을 기초로 하여 U-그루브 맞대기 용접을 실시 하였고, I-그루브 맞대기 용접에서 사용한 조건들과 유사한 용접 전류, 용접 속도에서 안정적인 이면비드를 얻을 수 있었다.

  • PDF

Kinematic Analysis of 100-m Women's Hurdlers at IAAF World Championships, Daegu 2011 (2011 대구세계육상선수권대회 여자 100m 허들 선수들의 운동학적 분석)

  • Ryu, Jae-Kyun;Park, Young-Jin;Ryu, Ji-Seon;Kim, Tae-Sam;Hwang, Won-Seob;Park, Sang-Kyoon;Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.541-550
    • /
    • 2011
  • The purpose of this study was to investigate the kinematic characteristics of the $5^{th}$ and $6^{th}$ hurdle clearances during the final of the 100-m hurdles event at the IAAF World Championships, Daegu 2011. To this end, the hurdling motions of the top 4 ranked female hurdlers in the competition were analyzed. A total of 12 cameras were used to record their motions, with a sampling frequency of 120 Hz. The cameras were calibrated using $11{\times}2{\times}1\;m$ control objects that covered all of the lanes ($1^{st}{\sim}8^{th}$ lanes). After analyzing all the data, we arrived at the following results. For the take-off phase, a negative relationship between the take-off time (CT) and athlete's rank was found. In addition, the average distances from the hurdle to take-off (L1) were shown to be 2.23 m and 2.17 m for the $5^{th}$ and $6^{th}$ hurdles, respectively. For the distance from the hurdle to landing (L2), Pearson ($1^{st}$ rank) and Carruthers($2^{nd}$ rank) showed inconsistent patterns whereas Harper ($3^{rd}$ rank) and Porter ($4^{th}$ rank) showed consistent patterns. All althetes revealed similar 3 steps patterns between hurdles, which consisted of a shorter $1^{st}$ step, longer $2^{nd}$ step and shorter $3^{rd}$ step.

The Effects of Needle Electrode Electrical Stimulation on Cellular Necrosis Blocking the Hippocampus after Induction of Ischemia (침전극저주파 자극이 해마의 세포사 차단에 미치는 영향)

  • Lee, Jung-Sook;Kim, Byung-Ki;Kim, Sung-Won;Kim, Ji-Sung;Kim, Dong-Il;Song, Chi-Won
    • Journal of Oriental Neuropsychiatry
    • /
    • v.20 no.2
    • /
    • pp.111-120
    • /
    • 2009
  • Objectives : This study was performed to investigate the effects of Needle Electrode Electrical Stimulation (NEES) on ischemia-induced cerebrovascular accidents. After obstruction and reperfusion of ${\ast}{\ast}$ arteries in white mice, the amounts of necrosis and inflammation related substances IL-6, Caspase-3, and PARP, C-fos were measured in neurons of the hippocampus. The following results were obtained. Methods : This study used 21 male specific pathogen free (SPF) SD (Sprague Dawley) rats, 8 weeks of age and approximately 300 g in weight, that were given at least 1 week to adapt to the lab environment Each exposed artery was completely occluded with non-absorbent suture thread and kept in that state for 5 minutes. The sutures were then removed to allow reperfusion of blood. Test group is control group for comparison with the common carotid artery occlusion models, a GI group that underwent common carotid artery occlusion, and a needle electrode electrical stimulation (NEES) group that underwent NEES after artery occlusion. The GI and NEES groups were given 12, 24, or 48 hours of reperfusion before NEES. NEES device (PG6, ITO, Japan, 9V, current, 2Hz) was used to stimulate the right and left acupoint ST36 of the SD rats for 30 minutes while they were sedated with 3% isoflurane. An immunohistochemistry test was done on the forebrains of the GI induced rats. All the data collected from this study was symbolized and analyzed using a statistics processing program (SPSS 12.0K/PC). The level of significance was set at ${\alpha}$=0.05 and a T-TEST analysis was used to find out the effects of treatment on each of the groups: the normal group, the CVA induced group, and the treatment after CVA induction group. Results : Both PARP and C-fos immuno-reactive cells, related to apoptosis, were greater in the GI groups than the NEES group. Caspase and IL-6 immuno-reactive cells, related to inflammation, were greater in the GI and NEES groups than the control group. Conclusions : This research was conducted to study the effects of NEES on CVA due to ischemia. Occlusion and reperfusion was performed on the common carotid arteries of white rats, after which amounts of substances related to neuron necrosis and inflammation - PARP, IL-6, Caspase-3, and C-fos - were measured in the Hippocampus

  • PDF

Water Repellent Finishes of Polyester Fiber Using Glow Discharge (글로우방전을 이용한 폴리에스테르섬유의 발수가공)

  • Mo, Sang Young;Kim, Gi Lyong;Kim, Tae Nyun;Chun, Tae Il
    • Textile Coloration and Finishing
    • /
    • v.5 no.4
    • /
    • pp.29-41
    • /
    • 1993
  • In order to surface Hydrophobilization of Poly(ethylene terephthalate) (PET) fiber samples were treated in the atmosphere of CF$_{4}$ or $C_{2}$F$_{6}$glow discharge. The sample used in this study was PET film which is 75$\mu$m thick made by Teijin, O-Type(Japan). The cleaned samples were placed in plasma reactor made of pyrex glass cylinder, and plasma processing was carried out by glow discharge of CF$_{4}$ or $C_{2}$F$_{6}$ gas, being continuously fed by gas flow and continuously pumped out by a vacuum system. Electric power source for generate plasma state was sustained alternating current(60Hz) and voltage was sustained 600 volt. The duration of plasma treatment varied from 15 to 120 seconds except special case, the monomer gase pressure varied from 0.02 to 0.3 Torr and power range was 10 to 90 watts. The hydrophobic features of changed PET surface were evaluated by contact angle measurement and surface chemical characteristics were analyzed by ESCA. Results can be summerized as follows. 1. The most favorable setting position of substrate was the center area between the two electrodes. 2. $C_{2}$F$_{6}$ discharge current was lower than that of CF$_{4}$ when same voltage was sustained. Treated efficiency between CF$_{4}$ and $C_{2}$F$_{6}$ did not revealed significant differences under same electric power(wattage). 3. When monomer pressure is very low below 0.02 torr, as though substrate is exposed to CF$_{4}$ or $C_{2}$F$_{6}$ plasma, it tend to be hydrophilic through a little of fluorine bond and a great deal of oxidizing reaction. 4. There brought good hydrophobilization when monomer pressure was more 0.1 torr and duration of glow discharge treatment was over 45 seconds. When monomer pressure was too high, discharge current became low. Although prolong the duration, there was no more high hydrophobilization. 5. According to ESCA analysis, there were a little CF bond and a prevailing CF$_{2}$ bond in CF$_{4}$-treated substrate. There were CF$_{3}$, a little CF and a prevailing CF$_{2}$ bond in $C_{2}$F$_{6}$-treated substrate.d substrate.

  • PDF

The multi-frequency characteristics of anchovy schools in the east of South Sea of South Korea (남해 동부 멸치어군의 다중주파수 특성)

  • Park, Yeongguel;Seo, Young-Il;Oh, Taeg-Yun;Park, Junseong;Jang, Choong-Sik;Kang, Myounghee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.2
    • /
    • pp.235-244
    • /
    • 2015
  • The multi-frequency characteristics of anchovy schools were investigated using six acoustic lines collected at 38 and 120 kHz while a primary trawl survey was conducted from 14 April and 18 April of 2014 in off the coast of Tongyeong and Geo-je. Here, the frequency characteristics mean ${\Delta}MVBS$ that is the difference of Mean Volume Backscattering Strength at two frequencies. To use the characteristics effectively, the optimal cell size ($10{\times}2m$) was determined by examining several different cell sizes in consideration with the shapes of fish schools and the ${\Delta}MVBS$ pattern. By examining 6 histograms of ${\Delta}MVBS$, afternoon groups were occupied more in the ${\Delta}MVBS$ range of -6~-4 dB than that of -4~-2 dB, comparing to morning groups. The ${\Delta}MVBS$ range of the morning groups was between -16.9 dB and 11.6 dB, and that of the afternoon groups -16.7 dB and 13.0 dB. The average and standard deviation were $-3.9{\pm}3.6$ dB in the morning and $-4.1{\pm}3.4$ dB in the afternoon, suggesting that morning groups were 2 dB higher than afternoon groups. The ${\Delta}MVBS$ range of all anchovy schools regardless of morning and afternoon was between -16.9 dB and 13.0 dB, their average ${\Delta}MVBS$ was $-4.1{\pm}3.5$ dB. The characteristics can support to identify anchovy species in the waters where multiple fish species are distributed. It is hoped that this study presents the availability and benefit of acoustic data from a primary trawl survey.

Development of the Heuristic Attention Model Based on Analysis of Eye Movement of Elementary School Students on Discrimination task (변별과제에서 초등학생의 안구운동 분석을 통한 발견적 주의 모델 개발)

  • Shin, Won-Sub;Shin, Dong-Hoon
    • Journal of The Korean Association For Science Education
    • /
    • v.33 no.7
    • /
    • pp.1471-1485
    • /
    • 2013
  • The purpose of this study was to develop a HAM (Heuristic Attention Model) by analyzing the difference between eye movements according to the science achievement of elementary school students on discrimination task. Science achievement was graded by the results of the Korea national achievement test conducted in 2012 for a random sampling of classes. As an assessment tool to check discrimination task, two discrimination measure problems from TSPS (Test of Science Process Skill, developed in 1994) which were suitable for an eye tracking system were adopted. The subjects of this study were 20 students from the sixth grade who agreed to participate in the research. SMI was used to collect EMD (eye movement data). Experiment 3.2 and BeGaze 3.2 programs were used to plan experiments and analyze EMD. As a result, eye movements of participants in discrimination tasks varied greatly in counts and duration of fixation, first fixation duration, and dwell time, according to students' science achievement and difficulty of the problems. By the analysis of EMD, strategies of the students' problem-solving could be found. During problem solving, subjects' eye movements were affected by visual attention; bottom-up attention, top-down attention and convert attention, and aflunter attention. In conclusion, HAM was developed, and it is believed to help in the development of a science learning program for underachievers.

Liposome-Microencapsulation of Lysozyme and Its Stimulated Release (Lysozyme의 Liposome 미세캡슬화와 유출 촉진)

  • Kim, Tae-Jong;Kim, Young-Sook;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.399-404
    • /
    • 1996
  • Encapsulation of lysozyme using lecithin vesicles and its stimilated release properties were studied. Lecithin vesicles were prepared by the dehydration-rehydration (DR)method. The highest encapsulation efficiency (EE) value of 80.1% was obtained by sonicating the multilamellar vesicles (MLVs) at 100 KHz for 120 min in bath sonicator. The value of entrapment progressively increased with the concentration of lysozyme, while the EE value decreased with the increase of enzyme concentration up to 50mg per 100mg per 100mg of lecithin, and then became nearly constant. At the pH of 5.9, only a small amount of lysozyme was released from DR vesicles during incubation at $37^{\circ}C$ As the pH decreased to 3.0, lysozyme was released more rapidly. Lysozyme release was accelerated for 24h and reached a plateau after 72h incubation with 1% Tween 80, $Ca^{2+}$ gave a pulse-like-release in the first hour, which was followed by a slow release.

  • PDF

KrF 엑시머 레이저를 이용한 웨이퍼 스텝퍼의 제작 및 성능분석

  • 이종현;최부연;김도훈;장원익;이용일;이진효
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 1993
  • This paper describes the design and development of a KrF excimer laser stepper and discusses the detailed system parameters and characterization data obtained from the performance test. We have developed a deep UV step-and-repeat system, operating at 248 nm, by retrofitting a commercial modules such as KrF excimer laser, precision wafer stage and fused silica illumination and 5X projection optics of numerical aperture 0.42. What we have developed, to the basic structure, are wafer alignment optics, reticle alignment system, autofocusing/leveling mechanisms and environment chamber. Finally, all these subsystem were integrated under the control of microprocessor-based controllers and computer. The wafer alignment system comprises the OFF-AXIS and the TTL alignment. The OFF-AXIS alignment system was realized with two kinds of optics. One is the magnification system with the image processing technique and the other is He-Ne laser diffraction type system using the alignment grating on the wafer. 'The TTL alignment system employs a dual beam inteferometric method, which takes advantages of higher diffraction efficiency compared with other TTL type alignment systems. As the results, alignment accuracy for OFF-AXIS and TTL alignment system were obtained within 0.1 $\mu\textrm{m}$/ 3 $\sigma$ for the various substrate on the wafers. The wafer focusing and leveling system is modified version of the conventional systems using position sensitive detectors (PSD). This type of detection method showed focusing and leveling accuracies of about $\pm$ 0.1 $\mu\textrm{m}$ and $\pm$ 0.5 arcsec, respectively. From the CD measurement, we obtained 0.4 $\mu\textrm{m}$ resolution features over the full field with routine use, and 0.3 $\mu\textrm{m}$ resolution was attainable under more strict conditions.

  • PDF