• 제목/요약/키워드: 12 lead ECG

검색결과 35건 처리시간 0.027초

HRECG에 의한 Late Potential의 검출에 관한 예비 연구 (Preliminary Study on the Detection of Late Potentials using High-Resolution Electrocardiography)

  • 우응제;박승훈
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.63-65
    • /
    • 1993
  • We have done a preliminary study on the detection of ventricular late potentials using high-resolution electrocardiography. We designed a battery powered low-noise ECG amplifier. We used the XYZ lead system and the amplifier provides 3 channels of X, Y, and Z signals with a conventional gain and another 3 channels of the amplitude-limited X, Y, and Z signals with high-gain. 12-bit data acquisition system interfaces the amplifiers to a personal computer for further signal analysis. Beat alignment algorithm was implemented on the low-gain signals to synchronize the signal averaging of the high-gain amplitude-limited signals. We suggest the use of the weighted vector sum of X', Y', and Z' signals based on the SNR of each channel. We speculate that this new method will increase the accuracy of the LP detector at the expense of more complicated hardware.

  • PDF

복식호흡이 젊은 성인의 심전도축에 미치는 영향 (Effect of Abdominal Respiration on the Electrical Axis of ECG in Young Adults)

  • 윤려민;김영식;윤임실;정한나;남정수;윤중수;이원준;최현주
    • 생명과학회지
    • /
    • 제20권5호
    • /
    • pp.723-728
    • /
    • 2010
  • 복식호흡은 혈압의 하강이나 심리적 진정 효과를 위한 이완 요법으로 사용되고 있는데, 이는 복식호흡이 자율신경계에 영향을 미치기 때문이다. 그러나 복식호흡으로 인한 심장의 전위 변화에 대해서는 연구가 전무하다. 따라서 본 연구에서는 복식호흡을 할 때에 심전도상의 변화를 건강한 젊은 남자 10명(평균$22.40{\pm}2.5$세)과 여자 10명(평균 $20.9{\pm}0.9$세)을 대상으로 알아보고자 하였다. 본 연구의 결과, P, R, T 진폭과, QTc 간격이 남녀 모두에서 복식호흡과 흉식호흡간의 차이가 없었다. 그러나 복식호흡 시에 PR 간격은 남자가 여자보다 유의하게 길었다. 심장 전기축에서 P축은 호흡 방식에 따라서 영향을 받지 않았으나, 남자에서는 복식호흡에서 심장의 QRS축이 증가하였고, 여자는 T 전기축이 증가하였다. 따라서 복식호흡은 심실이 탈분극과 이완되는 재분극 시의 전기축에 유의한 영향을 미치는 것으로 나타났다.

일회용 단일 심전도패드(SIM-Tree)의 기존 방법과 비교를 통한 효과 분석 (Effectiveness of Disposable Single Electrocardiogram Electrode (SIM-Tree) Comparing with Conventional Method)

  • 김혜선;최효정;김호중
    • 한국산학기술학회논문지
    • /
    • 제19권11호
    • /
    • pp.435-440
    • /
    • 2018
  • 본 연구의 목적은 기존의 심전도 측정 방법과 새로 발명된 일체형 심전도의 효과에 대한 비교분석을 시행하여 실행효과를 확인하기 위함이다. 이를 위해 46세의 건강한 남성모델을 대상으로 연구에 대한 정보가 없는 심전도 측정 유경험자를 대상으로 진행하였다. 기간은 2018년 6월 1일에서 6월 15일까지 한 기관에 연구와 회의로 내방한 인원 중에서 참여자를 선발하였고 이들에게 12리드형 기존 심전도(C)와 새로 개발된 심전도 방법인 SIM-Tree(SIM)를 간단한 교육 후 시행하여 참가자의 특성, 시행만족도, 각 단계별 시간, 그리고 연구에 대한 정보가 없는 순환기내과 교수의 일치도를 측정 비교하였다. 연구결과, 전체 참여자는 104명이었으며, 전체 시행시간은 SIM이 평균 65.39초로 C의 평균 94.38초에 비해서 통계적으로 빨랐다(p<0.05). 참가자의 만족도 조사에서 SIM이 평균 97.69로 C의 평균 68.5초에 비해서 높게 나타났다(p<0.05). 순환기 내과 교수를 통한 일치도 분석에서 급내상관계수(Intra-class correlation coefficient, ICC)점수가 0.959점으로 충분히 높게 나타났다(p<0.05). 결론적으로 새로 개발 된 SIM-Tree는 시술시간과 만족도에서 기존방법에 비해 효과적으로 나타났고 측정결과에서 기존방법과 높은 일치도를 보였다.

특발성 발작성 심방세동 환자에서 P파 간격분산의 의의 (P Wave Dispersion as a Predictor of Idiopathic Paroxysmal Atrial Fibrillation)

  • 홍그루;김웅;박종선;신동구;김영조;심봉섭
    • Journal of Yeungnam Medical Science
    • /
    • 제18권2호
    • /
    • pp.267-276
    • /
    • 2001
  • 특발성 발작성 심방세동 환자에서 P파 간격 분산은 대조군에 비해 유의하게 증가해 있었으며, 동율동으로 전환 후 약물로 예방 치료를 받은 경우 12개월 후 추적 검사했을 때 최대 P파 간격과 P파 간격분산이 통계적으로 의미있게 감소한다는 것을 알 수 있었다. 이는 아마도 발작성 특발성 심방세동 환자에서 정상인보다 심방내의 전기적 불안정성과 불균질성의 증가에 기인한다고 보여지며, 약물 치료를 했을 때 이러한 전기적 불안정성이 감소한다는 것을 알 수 있었다. 따라서 P파 간격분산은 향후 발작성 심방세동 환자의 선별 검사로서, 또한 치료 후 재발을 예측할 수 았는 예후 인자로서 유용하게 사용될 수 있으리라는 예측을 해보며, 이를 규명하기 위해 추후 더 많은 표본들에 대한 전향적인 시도가 이루어져야 될 것으로 사료된다.

  • PDF

완전방실블록 환자에서 쌍극의 영구박동기를 이식후 반복 발생된 증상이 단극으로 전환후 증상이 소실된 예 (A Case of Disappearing Symptoms Developed Repetitively in a Complete Atrioventricular Block Patient Implanted Bipolar Permanent Pacemaker After Converting It into Unipolar System)

  • 권준영;최교원;신동구;김영조;심봉섭;이현우
    • Journal of Yeungnam Medical Science
    • /
    • 제11권1호
    • /
    • pp.181-185
    • /
    • 1994
  • 저자들은 완전방실블록 환자에서 쌍극의 영구심장박동기를 이식후에도 계속되는 실신발작을 보여 단극의 영구심장박동기로 바꾼 후 그 증상이 소실된 예를 경험하였기에 이를 보고하는 바이다.

  • PDF

중증 서맥성 전도장애 개에서 피부경유 심박 조절 하에 기관내 스텐트 장착 (Intratracheal Stenting Under the Aid of Transcutaneous Cardiac Pacing in a Dog with Severe Bradycardic Conduction Defect)

  • 이승근;현창백;장광호
    • 한국임상수의학회지
    • /
    • 제25권5호
    • /
    • pp.400-404
    • /
    • 2008
  • 10살된 암컷 요오크셔테리어(체중 3 kg)가 심한 호흡곤란 청색증, 간헐성 발작 증상으로 진료가 의뢰되었다 신체검사 결과 지속성 맥박결손을 동반한 불규칙 서맥이 부정기적으로 관찰되었다. 심전도 검사에서 고도의 방실차단이, 방사선검사에서 중증 기관허탈이 진단되었다. 피부경유 심박조절 하에 자동확장 기관내 스텐트를 성공적으로 장착할 수 있었다.

國內 飼育 원숭이의 心電圖에 관한 硏究 (Studies on the Electrocadiogram in Non-human Primates Reared in Korea)

  • 서진석;서지민;이버들;송근호;이수진;김덕환;현병화;신남식
    • 한국임상수의학회지
    • /
    • 제19권2호
    • /
    • pp.132-138
    • /
    • 2002
  • Non-human primates are widely used for experimental animal and raised as companion animal in Korea. To establish the electrocadiogram (ECG) of non-human primates that are domestically raised, the author measured bipolar limb leads and augmented unipolar limb leads, after tiletamine/zolazepam (TZ) injection as sedative agents. The amplitudes of P,Q, R,S and T wave and duration time of P wave, QRS complex, PR and QT interval in each lead of ECG were evaluated in 7 non-human primates at 15 minutes after TZ injection, respectively. The amplitude of P wave in I, II,III, aVR, aVL and aVF leads revealed 0.06$\pm$ 0.05,0.14$\pm$ 0.05, 0.1 $\pm$ 0.05,-0.11 $\pm$ 0.06,-0.04$\pm$ 0.04 and 0.12$\pm$ 0.05 mV respectively. The amplitude of Q wave revealed -0.16$\pm$ 0.15, -0.23$\pm$ 0.18, -0.17$\pm$ 0.13, 0.16$\pm$0.13, 0.04$\pm$ 0.09 and -0.2$\pm$0.13 mV, respectively. The amplitude of R wave revealed 0.56$\pm$0.56, 1.24$\pm$ 0.67, 0.92$\pm$0.33, -0.37$\pm$ 1.14, -0.22$\pm$ 0.47 and 1.12 $\pm$ 0.47 mV, respectively. The amplitude of S wave revealed -0.02$\pm$ 0.08, -0.04$\pm$0.06, -0.06$\pm$0.04, 0.02$\pm$0.04, 0.04$\pm$0.09 and -0.04 $\pm$ 0.06 mV, respectively. The amplitude of T wave revealed -0.01 $\pm$ 0.15,-0.02$\pm$ 0.13, 0.01 $\pm$ 0.08, 0.02$\pm$ 0.12, 0.01 $\pm$ 0.11 and -0.03$\pm$ 0.09 mV, respectively. The duration time of P wave revealed 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.02, 0.05 $\pm$ 0.02, 0.04$\pm$ 0.01 and 0.04$\pm$ 0.01 sec, respectively. The duration time of QRS complex revealed 0.05 $\pm$ 0.02,0.05$\pm$ 0.01, 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.01 and 0.05 $\pm$ 0.01 sec, respectively. The duration time of PR interval revealed 0.08$\pm$ 0.01, 0.07$\pm$0.01,0.08$\pm$ 0.03, 0.08$\pm$0.01, 0.08$\pm$ 0.01 and 0.08$\pm$0.01 sec, respectively. The duration time of QT interval revealed 0.23$\pm$ 0.06, 0.22$\pm$ 0.05, 0.23 $\pm$ 0.06, 0.23$\pm$ 0.06, 0.24$\pm$ 0.05 and 0.22$\pm$ 0.02 sec, respectively. No significant changes were observed in e amplitude of P and T waves. The amplitude of QRS complex in ketamine group was higher than that of TZ group. However, no significant changes were observed in both intra-group and inter-group. There were no significant changes in the duration time of P wave, QRS complex and PR interval obtained from both groups. Also, the duration time of QT interval in TZ group was significantly longer at 30 min.(P< 0.05) an that of 10 minutes after injection. However, significant difference was not found between two groups. The mean cardiac electric axis in ketamine group tended to decrease until 30 min. after injection and then gradually increase. However, mean cardiac electric axis of TZ group was increased until 30 min. after injection and then decreased. But significant differences were not observed between groups. These results suggest that the ECG pattern after TZ injection to non-human primates reared in korea was established. It was also considered that the injection of ketamine and TZ didn't significantly affect on ECG pattern of the non-human primates.

홀터 심전계를 위한 심방세동 신호 추출 알고리즘 (Atrial Fibrillation Waveform Extraction Algorithm for Holter Systems)

  • 이전;송미혜;이경중
    • 전자공학회논문지SC
    • /
    • 제49권3호
    • /
    • pp.38-46
    • /
    • 2012
  • 심방세동은 발작성 심방세동 단계에서부터 검출 및 분석하여 적절한 치료를 실시하여야 하며, 홀터 심전계를 통해서만 측정할 수 있다. 현재 12채널 심전계를 통해서는 심방세동 신호를 추출할 수 있는 효과적인 방법들이 개발되어 있으나, 홀터 심전계를 위한 방법으로는 심실활동 템플릿을 단순 제거하는 ABS(averaged beat subtraction)방법이 사용되고 있다. 최근 단일 채널 심전도로부터 심방세동 신호를 추출하기 위한 PCA(principal component analysis) 또는 SVD(singular value decomposition) 기반의 알고리즘이 제안되기도 하였으나, 구현이 복잡하고 전문가의 개입이 필요한 한계가 있다. 본 논문에서는 주 입력인 심방세동 심전도에서 심실활동을 이벤트로서 검출한 뒤 이를 기준 입력으로 하는 이벤트 동기 적응필터(ESAF, event-synchronous adaptive filter)를 제안하고, 심방세동 신호 추출 성능을 평가해 보았다. 그 결과 기존 ABS 방법에 비해 우수할 뿐만 아니라, 전문가의 개입 없이도 PCA 또는 SVD 기반의 알고리즘과도 대등한 성능을 보였다. 나아가 이형성 심실활동이 있는 경우에도 효과적으로 대응할 수 있는 확장 ESAF 방법을 제안하였으며, 단형성 심실활동이 있는 경우와 유사한 수준의 성능을 확인하였다. 제안된 알고리즘을 홀터 심전계에 적용하면 발작성 심방세동 심전도의 분석뿐만 아니라 항부정맥 약물의 치료효과를 실시간으로 보다 정확하게 평가할 수 있을 것으로 기대된다.

동방결절 기능 부전군을 가진 페키니즈 종의 개에 대한 심장 박동수 반응형 영구 심장 박동기의 장착 (Rate-Responsive Permanent Pacemaker Implantation in a Pekingese Dog with a Sick Sinus Syndrome)

  • 한동현;최란;현창백
    • 한국임상수의학회지
    • /
    • 제27권5호
    • /
    • pp.569-572
    • /
    • 2010
  • 간헐적인 기절과 운동 불내성의 주요증상을 호소하는 4살 령의 중성화된 암컷 페키니즈 개 (체중 3.6 kg)가 내원하였다. 신체검사상 지속적인 맥박 결손을 가진 아주 불규칙한 심박동(irregularly irregular heart rhythm)이 나타났다. 12 유도 표면 심전도에서는 동방결절 기능 부전군을 의미하는 간헐적인 방실 접합부 이탈박동과 함께 특이적인 동정지가 나타났다. 본 환자에 대한 심장 박동수 반응형의 양극성 심장 박동조절기(VVIR type)를 이용한 영구적 경정맥형 심박 조율시술은 우심실 내에서 실시되었다. 심장 박동기 장착 이후, 환자의 임상증상은 눈에 띠게 호전되었다. 시술이후 아직까지 기절의 증상은 더 이상 나타나지 않고 있다.

관상동맥 회로술 치험 1예 (Aorto-Coronary Bypass Graft -A Case Report-)

  • 이두연
    • Journal of Chest Surgery
    • /
    • 제12권3호
    • /
    • pp.297-305
    • /
    • 1979
  • Occlusive coronary artery disease presents a potential threat to a significant population in the United States. According to many case reports, the increasing incidence of coronary artery disease due to atherosclerosis is noted in Korean, recently. Operative vascular procedures have increased steadily in number over the past 20 years in the United States. There have been many isolated case reports about coronary artery surgery, but these had little clinical impact. Nowadays, major three coronary bypass surgery has developed principally at three cardiac centers in the United States since 1967. Among three coronary bypass operation, the aorta-coronary artery saphenous vein bypass graft was first demonstrated by Favolaro and Effler at the Cleveland Clinic in 1967. We experienced one case of coronary artery disease, which was treated successfully by aorta-coronary saphenous vein graft with mild hypothermia under extracorporeal circulation in May, 1977. Saphenous vein was removed from above the knee and was 2.5 mm in diameter. The left ventricle was not vented for the left ventricle was not overdistended. Temporary artificial pace-maker-Medtronic-was implanted for the prevention and treatment of post-operative arrhythmia and heart block in post-operative first day. He is a 57 year old male businessman who had been suffered from hypertension [200 mmHg in systolic pressure] since 4 years ago, who had intermittent conservative treatment at local clinic. He had been afflicted with severe chest pain with choking sensation for 50 days. This symptom was aggravated exposing cold weather, or cold water, but was respond to rest. Pre-operative ECG revealed no any other ischemic sign except sinus bradycardia. Significant S-T segment depression was noted at lead II, AVF after double 5 minutes exercise, indicating positive Master`s test. Serum cholesterol was slight elevated to 253 mg/dl. Final pre-operative diagnosis was made by coronary arteriogram, which showed about 1.0-cm segmental 90 % occlusive atherosclerotic lesion in the proximal part of right coronary artery above the origin of acute marginal artery. Left coronary artery revealed good patency and there was no collateral circulation between right and left coronary artery .Hospital course was not eventful. He was discharged with good result on the post-operative day. He has been free from chest pain for longer than 2 years. And also the arterial flow in the coronary bypass graft is auscultated with the pocket-sized ultrasonic velocity detector, which shows the patency of the coronary bypass graft good.

  • PDF