• 제목/요약/키워드: 10 GHz

검색결과 3,814건 처리시간 0.035초

스핀 스프레이 방식으로 제조된 바륨계 페라이트 박막의 EMI (Electromagnetic Interference) 차폐 특성 (EMI (Electromagnetic Interference) Shielding Properties of Barium-Based Ferrite Thin Films Prepared by Spin Spray Method)

  • 오혜령;박연주;이우성;유찬세;유명재;서인태
    • 한국전기전자재료학회논문지
    • /
    • 제37권2호
    • /
    • pp.195-201
    • /
    • 2024
  • The low-temperature deposition of BaNi(2-x)CoxFe16O27 thin films with a Ba hexaferrite structure for electromagnetic shielding was studied. The BaNi(2-x)CoxFe16O27 thin films produced through the spin spray process were suitable for thin film deposition on a flexible substrate because it crystallized well at low temperature below 90℃. The change in shielding characteristics depending on the Co content of the BaNi(2-x)CoxFe16O27 thin film was investigated, and excellent shielding characteristics with S21 of -1 dB were obtained in a wide frequency range of 26~40 GHz when the Co content was 0.4 or more. The purpose of this study is to analyze changes in shielding properties caused by change in Co content in relation to phase changes in BaNi(2-x)CoxFe16O27 and obtain basic data for developing excellent flexible electromagnetic wave shielding materials.

국내 기존 합성단위도 방법의 비교 (The Comparison of Existing Synthetic Unit Hydrograph Method in Korea)

  • 정성원;문장원
    • 한국수자원학회논문집
    • /
    • 제34권6호
    • /
    • pp.659-672
    • /
    • 2001
  • 수공구조물의 설계홍수량 산정은 일반적으로 유출자료의 통계적 분석을 통해 산정된다. 하지만 자료의 부족으로 통계적인 방법을 이용하기 힘든 경우 이에 대한 대안으로 주로 강우-유출모형이 이용되고 있으며, 이 중 유출모형은 합성단위도법이 많이 이용되고 있다. 이러한 합성단위도 방법 중 국내에서는 Nakayasu 방법, Snyder 방법, SCS 방법, HYMO 방법 등이 주로 이용되거나 제안되었으며, 본 연구에서는 이러한 기존 방법들과 최근 개발된 건기연의 합성단위도법을 총 10개 유역의 지점 대표단위도와 비교 검토함으로써 국내 수문특성에 가장 적합한 방법을 결정해보고자 하였다. 먼저 지점 대표단위도와 각 방법으로부터 합성된 단위도의 첨두유량 및 첨두시간을 비교하였으며, 평균제곱근오차의 산정과 비교를 통해 단위도의 형상을 비교하였다. 그 결과, 일본에서 개발된 Nakayasu 방법은 단위도의 첨두유량, 첨두시간과 단위도의 형상에서 실제와 매우 다른 왜곡된 결과를 나타내고 있었으며, 나머지 방법들은 지점에 따라 차이는 있으나 전반적으로 건기연(2000)의 방법이 실제 대표단위도에 가장 근접한 결과를 주고 있었다. 또한, 합성단위도 개발에 이용된 자료, 지점 및 유역특성 등을 조사한 결과, 과거의 성과를 함께 이용한 건기연의 방법이 가장 포괄적임을 알 수 있었다. 따라서 수문실무에서 합성단위도법을 적용할 경 우, Nakayasu 방법을 이용하여 설계홍수량을 추정하는 방법은 지양되어야 할 것으로 보여지며, 건기연의 방법을 이용하는 것이 가장 적절한 결과를 줄 것으로 판단할 수 있었다. 하지만 만약 SCS나 Nakayasu 방법을 적용한다 할 지라도 국내 자료를 통해 해당 모형의 매개변수나 회귀적 등을 조정하여 이용한다면 보다 적절한 결과를 얻을 수 있을 것으로 생각된다.다. 재생 $Al_2$O$_3$시편의 치밀화를 위하여 5~20wt%의 폐유리분말을 첨가하여 1200~1$650^{\circ}C$에서 5시간 소결한 시편은 폐유리분말의 첨가량이 증가함에 따라 최대 밀도와 3점곡강도를 나타내는 온도는 감소하였으나, 140$0^{\circ}C$이상에서는 페유리분말을 첨가하지 않은 시편에 비하여 밀도와 3점곡강도가 감소하여 재생 $Al_2$O$_3$세라믹스의 소결성 향상에는 기여하지 못하였다.TEX>$_{0}$=32900 GHz, $\tau$$_{f}$ =-2.2 ppm/$^{\circ}C$이었다. B$_2$O$_3$첨가의 경우 최적의 첨가량은 1.0~2.5 wt%이었으며 8$50^{\circ}C$에서 소결한 경우 얻어진 유전특성은 $\varepsilon$$_{r}$20.3~22.1, Q$\times$f$_{0}$=48700~54700 GHz, $\tau$$_{f}$ =+2.4~+8.2ppm/$^{\circ}C$이었다.describe the desired urban resort nature of the stadium. From this historical perspective it seems that stadiums have great potential as urban resorts. The factor that will determine their success is

  • PDF

1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석 (Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC)

  • 김성일;강광용;이해영
    • 대한전자공학회논문지SD
    • /
    • 제44권8호
    • /
    • pp.52-59
    • /
    • 2007
  • 본 논문에서는 이더넷 광 네트워크 구현용 핵심 부품인 1.25 Gbps 단일집적 양방향 광전 SoC (Monolithic integrated hi-directional optoelectronic system-on-a- chip)의 전기적 혼신을 감소시키기 위한 임플란트의 전기적 절연 특성을 분석하였으며, 측정결과로부터 임플란트의 등가회로를 추출하였다. InP 기판상에 단일집적된 양방향 광전 SoC의 구성은 다음과 같다. 먼저 송신부는 전기신호를 광신호로 바꾸어 전송하는 레이저 다이오드(Laser Diode)와 레이저 다이오드의 출력을 모니터링하기 위한 모니터 포토다이오드(Monitor Photodiode)로 구성된다. 그리고 수신부는 디지털로 변조된 후 입력된 광신호를 전기신호로 변환하는 디지털 포토다이오드(Digital photodetector)로 구성된다. IEEE 802.3ah와 ITU-T G.983.3가 요구하는 기가비트 수동 광 네트워크 (Gigabit-Passive Optical Network)용 ONU (Optical Network Unit)의 양방향 광전 모듈의 규격을 만족하기 위해서는 수신부의 수신감도는 -24 dBm (@ BER (Bit Error Rate)=10-12)을 만족해야 하므로, 모듈 내의 전기적 혼신은 DC에서 3 GHz까지 -86 dB이하로 유지되어야 한다. 한편, 임플란트 구조의 측정 및 분석 결과, 단일 InP 기판상에 집적된 레이저 다이오드와 모니터 포토다이오드 간의 간격과, 그리고 모니터 포토다이오드와 디지털 포토다이오드간의 간격을 200 mm 이상을 유지하면서, 20 mm 폭의 임플란트를 삽입하였을 경우, -86 dB 이하의 전기적 혼신을 만족하였다. 본 논문에서 사용하고 분석한 임플란트 구조 및 특성은 단일집적 양방향 광전 SoC 뿐만 아니라, 아날로그/디지털 혼합모드 SOC의 설계 제작용 기본 데이터로 활용할 수 있다., 1.0 mm로 나타났다. 하체 고정기구를 사용한 환자군에서 디지털재구성사진과 모의 치료사진의 차이는 좌우, 전후, 두미 방향에 따라 각각 $1.3{\pm}1.9\;mm$, $1.8{\pm}1.5\;mm$, $1.1{\pm}1.1\;mm$, 디지털재구성사진과 조사영역사진 간의 차이는 각각 $1.0{\pm}1.8\;mm$, $1.2{\pm}0.9\;mm$, $1.2{\pm}0.8\;mm$, 조사영역사진 간의 평균 표준편차는 각각 0.9 mm, 1.6 mm, 0.8 mm로 고정기구를 사용하지 않았을 때보다 유의하게 재현성이 향상된 것으로 나타났다. 결 론: 본 연구에서 고안된 하체 고정기구는 골반부암 환자 치료 시 편안함을 제공해 주고 재현성 향상에 도움을 주는 것으로 사료된다..) 이 때 방사선 조사량의 중앙값은 3,600 cGy이었다. 이후 추가 방사선 치료 시 계획용 CT를 사용하지 않고 2-oblique fields 사용하여 치료한 경우가 87명(35.4%)이었는데 방사선 조사량의 중앙값은 1,800 cGy이었다. 전 환자에서 1일 1회 180 cGy로 치료하였다. 전 환자에서 조사된 총 방사선량의 중앙값은 5,580 cGy이었다. 수술 후 방사선 치료를 시행한 경우 중앙값은 5,040 cGy이었고 수술을 받지 않은 환자 중앙값은 5,940 cGy이었다. 근접조사 방사선 치료는 총 34명(13.8%)에서 시행되었고, 전 환자에서 high dose rate Iridium-192를 사용하였다. 조사범위는 종양에서 longitudinal margin의 중앙값은 1 cm, prescribed isodose curve에서 axial length의 평균값은 8.25 cm, 폭은 2 cm, 그리고 전후 폭의 중앙값도 2 cm이었다. Fraction size의 중앙값은

Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법 (Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method)

  • 한용희;김태형;천송이;김동혁;이광식;은충기;전재량;문치웅
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권1호
    • /
    • pp.31-39
    • /
    • 2009
  • 목적 : 본 연구는 PRF(Proton Resonance Frequency)를 이용한 MR 온도감시 영상에서 시간 해상도를 keyhole방법 적용으로 향상시키고자하였다. 제시된 keyhole방법과 기존 온도영상 방법 사이의 비교를 위해 온도 값에 대한 RMS(Root Mean Square) 오차와 SNR(Signal to Noise Ratio)을 비교하였다. 대상 및 방법 : PRF 방법과 GRE(Gradient Recalled Echo)를 이용하여 MR 온도영상을 구현하였으며 장비로는 임상용 1.5T MRI 장치를 이용하였다. 인체모사 조직인 2% 한천 젤 팬텀과 돼지 근육조직으로 실험을 수행하였다. 2.45GHz대역의 마이크로파 발생장치로 MR호환 동축 슬롯 안테나를 구동하여 MRI장치 내에서 대상 조직과 팬텀을 5분간 가열하였다. 가열 직후 10분 동안에 순차적으로 MR 원 데이터를 획득하였다. 획득된 원 데이터는 PC로 전송되어 전체 위상을 부호화하여 얻은 원 데이터의 바깥영역과 K-space의 중앙 영역을 각각 128, 64, 32, 16으로 위상부호화된 데이터로 keyhole영상을 재구성하였다. 256개로 전체 부호화된 자체-참조 온도영상과 RMS 오차를 비교하였으며, zero-filling 영상과 SNR비교를 하였다. 결과 : keyhole 온도 영상에서 위상부호화 수가 128, 64, 32, 16으로 줄어들수록 RMS 오차로 산출한 온도의 차이가 0.538, 0.712, 0.786, 0.845$^{\circ}C$ 만큼 증가하였으나 SNR 값은 keyhole의 위상부호화 수가 줄어도 유지되었다. 결론 : 본 연구는 고정된 매트릭스 크기에 keyhole 방법 적용을 이용하여 온도 감시에서의 시간해상도 증가와 SNR 값을 유지하는 결과를 도출하여 성공적인 적용을 보여 주었다. 본 연구를 기반으로 한 다음 연구에서는 최적화된 변수를 이용한 keyhole 방법 적용으로 최소 온도 오차의 실시간 MR 온도 감시가 가능할 것이라 예상된다.

  • PDF

산화물 박막을 이용한 인덕터, 캐패시터 및 LC 복합 소자 제조 (Fabrication of Inductors, Capacitors and LC Hybrid Devices using Oxides Thin Films)

  • 김민홍;여환국;황기현;이대형;김인태;윤의준;김형준;박순자
    • 한국재료학회지
    • /
    • 제7권3호
    • /
    • pp.175-179
    • /
    • 1997
  • 고밀도 고기능 전자기기의 발전과 고주파 이동통신의 증대에 따라 전자소자의 소형화, 집적화가 요구되고 있으며, 이는 전자소자의 박막화를 필요로 한다. 캐패시터, 인덕터는 전기 회로를 구성하는 기본적인 소자로서 그 응용 범위는 무수히 많으며, 따라서 이들 소자의 박막화는 전자소자의 소형화, 경량화에 큰 영향을 끼치리라 생각된다. 본 연구에서는 강자성 및 강유전 산화물 박막을 이용하여 인덕터, 캐터시터, LC 복합소자를 제조하였다. 고온 산화분위기에서 안정한 Au를 리프트 오프법으로 금속배선 패턴을 향상하였고, 스퍼터링, 화학기상증착법 등을 이용하여 산화물 박막을 증착하였다. 0.5-15GHz에서 network analyzer로 측정하고 Microwave Design System으로 분석한 결과 5nH의 인덕턴스, 10,000pF의 캐패스턴스, $10^{6}-10^{9}Hz$ 정도의 공진 주파수 값을 얻었다.

  • PDF

Direction of Tissue Contraction after Microwave Ablation: A Comparative Experimental Study in Ex Vivo Bovine Liver

  • Junhyok Lee;Hyunchul Rhim;Min Woo Lee;Tae Wook Kang;Kyoung Doo Song;Jeong Kyong Lee
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.42-51
    • /
    • 2022
  • Objective: This study aimed to investigate the direction of tissue contraction after microwave ablation in ex vivo bovine liver models. Materials and Methods: Ablation procedures were conducted in a total of 90 sites in ex vivo bovine liver models, including the surface (n = 60) and parenchyma (n = 30), to examine the direction of contraction of the tissue in the peripheral and central regions from the microwave antenna. Three commercially available 2.45-GHz microwave systems (Emprint, Neuwave, and Surblate) were used. For surface ablation, the lengths of two overlapped square markers were measured after 2.5- and 5-minutes ablations (n = 10 ablations for each system for each ablation time). For parenchyma ablation, seven predetermined distances between the markers were measured on the cutting plane after 5- and 10-minutes ablations (n = 5 ablations for each system for each ablation time). The contraction in the radial and longitudinal directions and the sphericity index (SI) of the ablation zones were compared between the three systems using analysis of variance. Results: In the surface ablation experiment, the mean longitudinal contraction ratio and SI from a 5-minutes ablation using the Emprint, Neuwave, and Surblate systems were 28.92% and 1.04, 20.10% and 0.53, and 24.90% and 0.45, respectively (p < 0.001). A positive correlation between longitudinal contraction and SI was noted, and a similar radial contraction was observed. In the parenchyma ablation experiment, the mean longitudinal contraction ratio and SI from a 10-minutes ablation using the three pieces of equipment were 38.60% and 1.06, 32.45% and 0.61, and 28.50% and 0.50, respectively (p < 0.001). There was a significant difference in the longitudinal contraction properties, whereas there was no significant difference in the radial contraction properties. Conclusion: The degree of longitudinal contraction showed significant differences depending on the microwave ablation equipment, which may affect the SI of the ablation zone.

초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도 (In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound)

  • 이수영;조상현;이충휘;김종만
    • 한국전문물리치료학회지
    • /
    • 제10권1호
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

아몰퍼스 FeCoSiB 박막의 고감도 스트레인 검출특성 (High Sensitive Strain Detection of FeCoSiB Amorphous Films)

  • 신광호;황정현일;사공건
    • 센서학회지
    • /
    • 제9권1호
    • /
    • pp.22-27
    • /
    • 2000
  • 고자왜특성과 연자성특성을 가짐으로서 우수한 자기기계결합특성을 나타내는 아몰퍼스 FeCoSiB 박막의 스트레인 검출특성에 대해 연구하였다. 투자율은 박막기판을 마이크로메타를 이용하여 벤딩시켜 박막에 스트레인을 인가하면서 조사하였으며, 이때 박막에 스트레인이 인가되면 박막의 자기기계결합에 의해 투자율이 변화하였다. 스트레인에 의한 성능지수 $F=({\Delta}{\mu}/{\mu})/{\varepsilon}$ (단위스트레인에 대한 투자율의 변화)가 $1.2{\times}10^5$라는 매우 높은 값을 나타내어 본 연구에서 제작한 박막이 스트레인에 대하여 고감도특성을 가지고 있음을 알 수 있었다. 또한 제작된 박막을 센서소자로 응용하기 위해 박막을 미세 가공하고, 스트레인에 대한 고주파 임피던스의 변화를 조사하였으며, 박막의 우수한 자기기계결합특성으로 박막패턴의 임피던스는 인가된 스트레인에 의해 민감하게 변화되었다. 특히, 100MHz의 구동주파수에 있어서 $300{\times}10^{-6}$의 스트레인이 인가된 경우 46%의 임피던스변화율이 얻어졌다. 따라서 본 연구에서 제작한 박막소자는 초고감도의 스트레인 센서로 사용될 수 있을 것으로 기대된다.

  • PDF

Glass첨가에 의한 BaO-Nd2O3-TiO2계 세라믹스의 저온소결과 마이크로파 유전특성 (The Effect of Glass Addition on the Sintering and Dielectric Properties of BaO-Nd2O3-TiO2 Microwave Ceramics)

  • 신동순;최영진;박재환;남산;박재관
    • 한국세라믹학회지
    • /
    • 제40권1호
    • /
    • pp.98-103
    • /
    • 2003
  • BaO-Nd$_2$O$_3$-TiO$_2$계 유전체 세라믹스에 유리를 첨가하여 저온소결특성과 마이크로파 유전특성을 조사하였다. 알칼리가 첨가된 lithium borosilicate계 유리 프릿을 10~30wt% 범위로 첨가함으로서 소결온도를 130$0^{\circ}C$에서 100$0^{\circ}C$로 낮추었으며, 95% 이상의 상대밀도를 갖는 소결체를 얻을 수 있었다. 유리의 첨가량이 l0wt% 이상으로 증가함에 따라 결정상의 변화가 뚜렷이 나타났고 이에 따라 밀도 및 전기적 특성이 크게 변화하였다 l0wt%의 유리 프릿을 첨가하여 100$0^{\circ}C$에서 소결한 경우 유전율($\varepsilon$$_{r}$) 65 및 품질계수(Qxf) 2800GHz의 특성을 얻을 수 있었다.

강자성공명을 이용한 $Co_{84}\;Hf_{16}$ 박막의 자기적 성질 연구 (The Magnetic Properties of $Co_{84}\;Hf_{16}$ Thin Films by FMR)

  • 김기현;장재호;김영호
    • 한국자기학회지
    • /
    • 제7권4호
    • /
    • pp.191-195
    • /
    • 1997
  • DC magnetron sputtering 방법에 의해 $Co_{84}$H $f_{16}$ 박막 (1300 .angs. , 2150 .angs. )을 제작하였다. 박막의 자기적 특성을 조사하기 위해서 J-band (7.42 GHz) 마이크로파 영역의 강자성 공명 (ferromagnetic resonance) 장치를 이용하였다. 측정된 공명 흡수선의 주 모드(main mode)로부터 계산된 분광학적 분리상수 g 값은 1300 .angs. , 2150 .angs. 일 때 각각 2.06과 2.07이었으며, 상온에서의 유효 자화(4 .pi. $M_{eff}$)값은 10385 emu/$cm^{3}$,10770 emu/$cm^{3}$였다. 자기 이방성을 조사하기 위해 VSM(vibrating sample magnetometer)을 이용하여 측정된 포화자화(4 .pi. $M_{s}$ )값은 16409 emu/$cm^{3}$와 14222 emu/$cm^{3}$였다. 유효 이방성 자기장 $H_{A}$ (effective anisotropy field)과 일축 이방성상수 $K_{u}$ (uniaxial anisotropy constant)는 각각 6024 Oe, 3452 Oe와 3.93 * $10^{6}$ erg/$cm^{3}$, 1.95 * $10^{6}$erg/$cm^{3}$였다. 77K에서 상온까지 온도에 따른 유효 포화 자화(4 .pi. $M_{eff}$)값을 측정하였으며, 포화자화의 온도의존성은 Bloch 법칙을 잘 만족시켰다. 이 포화자화곡선을 최적화하여 Bloch 상수 B, C를 구하였고, 77K에서 0K까지 외삽법으로 구한 $M_{eff}$(0)는 각각 894 erg/$cm^{3}$, 891 erg/$cm^{3}$였으며, 스핀파 경도 상수 D값과 교환 경도 상수 $A_{eff}$는 각각 148 meV .angs. $^{2}$, 103.8 meV .angs. $^{2}$와 1.77 * $10^{-6}$ erg/cm, 0.67 * $10^{-6}$ erg/cm 였다.다.

  • PDF