• Title/Summary/Keyword: 1.5 generation

Search Result 3,686, Processing Time 0.104 seconds

The Long-term Operating Evaluation of the Grid Connected Photovoltaic System (태양광발전시스템의 장기운전에 의한 성능특성 분석)

  • Kim, Eui-Hwan;Kang, Seng-Won;Kim, Jae-Eon
    • New & Renewable Energy
    • /
    • v.7 no.2
    • /
    • pp.28-35
    • /
    • 2011
  • Recently, photovoltaic systems have been devolved into much larger systems up to MW-scale. Photovoltaic industry participants give their focus on power generation capability of photovoltaic modules because their benefits can be decided from the amount of generation. The information on long-term performance change of photovoltaic modules helps to estimate the amount of power generation and evaluate the economic cost-benefits. Long-term performance of a PV system has been analyzed with operation data for 12 years from 1999 to 2010. In the first year, the amount of yearly power generation was 57.7 MWh with 13.2% capacity factor. In 2007, the amount of yearly generation was 44.3 MWh with 10.14% capacity factor, and in 2010, the amount was decreased down to 38.1 MWh with 8.7% capacity factor. The result means that long-term capacity factor has been 4.5% decreased for 12 years and that the amount of generation has been decreased 34.0% for 12 years which is 2.8 % per year. The latter capacity factor has been decreased faster than 0.20%, the average rate for 10 years. The performance decrease of the PV system is meant to be accelerated. The decrease of performance and utilization is due to aged deterioration of photovoltaic modules and lowering conversion efficiency of PCS.

Wide Spectrum of Inhibitory Effects of Sertraline on Cardiac Ion Channels

  • Lee, Hyang-Ae;Kim, Ki-Suk;Hyun, Sung-Ae;Park, Sung-Gurl;Kim, Sung-Joon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.5
    • /
    • pp.327-332
    • /
    • 2012
  • Sertraline is a commonly used antidepressant of the selective serotonin reuptake inhibitors (SSRIs) class. In these experiments, we have used the whole cell patch clamp technique to examine the effects of sertraline on the major cardiac ion channels expressed in HEK293 cells and the native voltage-gated $Ca^{2+}$ channels in rat ventricular myocytes. According to the results, sertraline is a potent blocker of cardiac $K^+$ channels, such as hERG, $I_{Ks}$ and $I_{K1}$. The rank order of inhibitory potency was hERG > $I_{K1}$ > $I_{Ks}$ with $IC_{50}$ values of 0.7, 10.5, and 15.2 ${\mu}M$, respectively. In addition to $K^+$ channels, sertraline also inhibited $I_{Na}$ and $I_{Ca}$, and the $IC_{50}$ values are 6.1 and 2.6 ${\mu}M$, respectively. Modification of these ion channels by sertraline could induce changes of the cardiac action potential duration and QT interval, and might result in cardiac arrhythmia.

Generation of Reactive Oxygen Species and Subsequent DNA Fragmentation in Bovine Cultured Somatic Cells

  • Hwang, In-Sun;Kim, Ho-Jeong;Park, Chun-Keun;Yang, Boo-Keun;Cheong, Hee-Tae
    • Reproductive and Developmental Biology
    • /
    • v.35 no.4
    • /
    • pp.485-489
    • /
    • 2011
  • The present study was conducted to examine the reactive oxygen species (ROS) generation levels and subsequent DNA damage in the bovine cultured somatic cells. Bovine ear skin cells were classified by serum starvation, confluence and cycling cells. Cells were stained in 10 ${\mu}M$ dichlorohydrofluorescein diacetate ($H_2DCFDA$) or 10 ${\mu}M$ hydroxyphenyl fluorescein (HPF) dye to measure the $H_2O_2$ or $^{\cdot}OH$ radical levels. The samples were examined with a fluorescent microscope, and fluorescence intensity was analyzed in each cell. $H_2O_2$ and $^{\cdot}OH$ radical levels of cultured somatic cells were high in confluence group ($7.1{\pm}0.7$ and $8.4{\pm}0.4$ pixels/cell, respectively) and significantly low in serum starvation group ($4.9{\pm}0.4$ and $7.0{\pm}0.4$ pixels/cell, respectively, p<0.05). Comet tail lengths of serum starvation ($148.3{\pm}5.7$ ${\mu}M$) and confluence ($151.1{\pm}5.0$ ${\mu}M$) groups were found to be significantly (p<0.05) increased in comparison to that of cycling group ($137.1{\pm}7.5$ ${\mu}M$). These results suggest that the culture type of donor cells can affect the ROS generation, which leads the DNA fragmentation of the cells.

Mechanism and regulation of body malodor generation (1) -Effect of iron in axillary malodor and using an antioxidant as a deodorant-

  • Ichinose, N.;lida, S.;Gomi, T.;Someya, K.;Hirano, K.;Ogura, M.;Yamazaki, S.;Sakurai, K.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.139-144
    • /
    • 2003
  • Using GC/MS and GC/Olfactmetry analysis, we identified two vinyl ketones such as 1-Octen-3-one (OEO) and cis-1, 5-Octadien-3-one (ODO) as key materials in axillary odor. OEO and ODO showed a strong metallic odor and low odor threshold. These two materials were occurred from the reaction of unsaturated long fatty acids in lipids and the iron ion in our body's metabolism. Then, it was recognized that Morus alba (Japanese name, Kuwa) extract, one of the plant extract, showed a very good effect to control the generation of these vinyl ketones due to its remarkable anti-oxidization effects.

  • PDF

Research on the Distribution and Damage of the Fall Webworm Hyphantria cunea Durury (미국 흰불나방의 피해(被害)와 분포조사(分布調査))

  • Ko, Jeho;Lee, Sangok
    • Journal of Korean Society of Forest Science
    • /
    • v.7 no.1
    • /
    • pp.35-39
    • /
    • 1968
  • 1. The Fall webworm, Hyphantria cunea was widely distributed ranging from Seoul to Kangnung, Yung-ju, Taegu, Iri and Kwang-ju in 1967. 2. Heavily infested tree species by the Fall webworm were Sycamore, Cherry, ash-leaved maple, poplar, and elm. 3. The average number of larval masses per damaged garden tree and roadside tree was 7.0 and 3.4 respectively. 4. Trees of 6-10m in height had most number of larval masses and were most heavily infested. 5. More larval masses were found in the median and lower parts than higher parts of the crown. 6. The ratio of damaged by second generation was 55% higher than by first generation. The ratio of damage by 3rd generation is 18% less than by first generation.

  • PDF

Big Data and Knowledge Generation in Tertiary Education in the Philippines

  • Fadul, Jose A.
    • Journal of Contemporary Eastern Asia
    • /
    • v.13 no.1
    • /
    • pp.5-18
    • /
    • 2014
  • This exploratory study investigates the use of a computational knowledge engine (WolframAlpha) and social networking sites (Gmail, Yahoo and Facebook) by 200 students at De La Salle-College of Saint Benilde, their "friends" and their "friends of friends" during the 2009 through 2013 school years, and how this appears to have added value in knowledge generation. The primary aim is to identify what enhances productiveness in knowledge generation in Philippine Tertiary Education. The phenomenological approach is used, therefore there are no specific research questions or hypotheses proposed in this paper. Considering that knowledge generation is a complex phenomenon, a stochastic modelling approach is also used for the investigation that was developed specifically to study un-deterministic complex systems. A list of salient features for knowledge generation is presented as a result. In addition to these features, various problem types are identified from literature. These are then integrated to provide a proposed framework of inclusive (friendly) and innovative social networks, for knowledge generation in Philippine tertiary education. Such a framework is necessarily multidisciplinary and useful for problem-solving in a globalized and pluralist reality. The implementation of this framework is illustrated in the three parts of the study: Part 1: Online lessons, discussions, and examinations in General Psychology, Introduction to Sociology, and Life and Works of Jose Rizal, for the author's students in De La Salle-College of Saint Benilde; Part 2: Facebook Report analytics of students and teachers, their friends and their friends of friends via WolframAlpha; and Part 3: Social Network Analysis of the people and groups influencing the courses' scope-and-sequence in the new General Education Curriculum for Tertiary Schools and Institutions in the Philippines.

Application of probabilistic safety assessment (PSA) to the power reactor innovative small module (PRISM)

  • Alrammah, Ibrahim
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3324-3335
    • /
    • 2022
  • Several countries show interest in the Generation-IV power reactor innovative small module (PRISM), including: Canada, Japan, Korea, Saudi Arabia and the United Kingdom. Generation IV International Forum (GIF) has recommended the utilizing of probabilistic safety assessment (PSA) in evaluating the safety of Generation-IV reactors. This paper reviews the PSA performed for PRISM using SAPHIRE 7.27 code. This work shows that the core damage frequency (CDF) of PRISM for a single module is estimated by 8.5E-8/year which is lower than the Generation-IV target that is 1E-6 core damage per year. The social risk of PRISM (likelihood of latent cancer fatality) with evacuation is estimated by 9.0E-12/year which is much lower than the basic safety objective (BSO) that is 1E-7/year. The social risk without evacuation is estimated by 1.2E- 11/year which is also much lower than the BSO. For the individual risk (likelihood of prompt fatality), it is concluded that it can be considered negligible with evacuation (1.0E-13/year). Assuming no evacuation, the individual risk is 2.7E-10/year which is again much lower than the BSO. In comparison with other PSAs performed for similar sodium fast reactors (SFRs), it shows that PRISM concept has the lowest CDF.

Design of Aerosol Generator for Inhalation Toxicology Study of Lead and Evaluation with Real Time Monitoring (납의 흡입독성 연구를 위한 에어로졸 발생장치의 고안 및 실시간 모니터링을 이용한 성능평가)

  • Jeung Jae Yeal;Kim Jung Man;Kim Tae Hyeung;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.2
    • /
    • pp.373-379
    • /
    • 2002
  • This paper was the design of aerosol generator for inhalation toxicology study of lead and evaluation with real time monitoring, and applied several engineering methodology to classical aerosol generator to cope with it's disadvantages. According to the testing conditions, source temperature 50℃ and inlet-duct band heater temperature 150℃, aerosol generation results for sodium chloride and lead acetate were as followings: CPM(Count Per Minute) for Sodium chloride that used for the testing material in aerosol generation and inhalation system was decreased in the 2nd and the 3rd hour's serial trials, but CVs(coefficient of variation) were maintained within 10%. CPMs for 5 and 2.5 gram of lead acetate that used for aerosol generation and inhalation exposure of lead showed similar results because of the sedimentation of lead acetate on piezoelectric crystal with time. For that reason, heating and mixing of nebulizing solution will be needed to generate lead aerosol with stable profile and maximum generation efficiency. Fluctuations of 10 and 5 gram lead acetate were low but 2.5gram was high. However, CVs for 10, 5, and 2.5gram lead acetate were within 10%. Considering the theoretical efficiencies for sodium chloride and lead acetate, 5gram sodium chloride and 2.5gram lead acetate were appropriate choice. Aerosol generation characteristics for two materials with 1 hour interval were different with respect to the fluctuation of CPM and the decrease to 10gram in it's material. For that reason, sodium chloride can not be used to estimate the aerosol generation and it's related parts for lead acetate. According to the testing conditions, source temperature 20, 50, 70℃, and inlet-duct band heater temperature 20, 50, 100, 150, 200℃, aerosol generation results for sodium chloride and lead acetate were as followings: Excluding inlet-duct band temperature 200℃, maximum CPM for sodium chloride was manifested in source temperature 70℃ with each inlet-duct band temperature conditions. We suggest that this condition was the optimum in the design of aerosol generator, inhalation system, and the testing. Maximum CPMs for 10, 5, and 2.5gram sodium chloride were from source temperature 70℃ and inlet-duct band temperature 20℃. Excluding inlet-duct band temperature 50, 200℃, maximum CPMs for lead acetate were indicated in source temperature 50℃ with each inlet-duct band temperature conditions. We suggest that this condition was the optimum in the design of aerosol generator, inhalation system, and the testing for lead inhalation study. Source and inlet-duct band temperatures for 10, 5, 2.5gram lead acetate were 50 and 100℃, 50 and 100℃, 50 and 150℃, respectively. In conclusion, considering above 2 paragraphs of results for aerosol generation, 5gram efficiencies for sodium chloride, lead acetate were higher than 2.5gram's. If inlet-duct band temperature was same, aerosol generation was increased with increase of source temperature. To get maximum aerosol generation will be the conditions that set the appropriate inlet-duel band temperature for each materials and increase the source temperature.

Estimation of Ventilation and Generation Rates Using Nitrogen Dioxide Measurements of Indoor and Outdoor in Houses (주택 실내.외 이산화질소 측정을 이용한 환기량 및 발생량 추정)

  • Yang, Won-Ho;Im, Sung-Guk;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1069-1073
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ generation rate were estimated. Mean of ventilation rate was 1.41 ACH in houses, assuming a residential N02 deposition constant of 0.94 $hr^{-1}$. Mean generation rate of $NO_2$ was 16.5 ppbv/hr. According to house characterization, inside smoking and family number were higher $NO_2$ generation rates, and apartment was higher than single-family house. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

The policy study on the power grid operation strategy of new and renewable energy combined generation system (도서지역의 신재생에너지복합발전 전력계통 운영방안에 관한 정책연구)

  • Kim, Eui Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.109.1-109.1
    • /
    • 2011
  • KEPCO was operating power plants with diesel generators in 49 islands including Baekryeong-Do, and the generation capacity was about 66 MW in 2008. The cost of fuel is increasing by the international oil price inflation and continuous rise of oil price is predicted. For the stabilizing of electric power supply to the separate islands, renewable energy and fuel cell systems were considered. Hydrogen is made using renewable energy such as wind power and solar energy, and then a fuel cell system generates electricity with the stored hydrogen. Though the system efficiency is low, it is treated as the only way to secure the stable electric supply using renewable energy at this present. The analytic hierarchy process was used to select suitable candidate island for the system installation and 5 islands including Ulleung-Do were selected. Economic evaluation for the system composed of a kerosene generator, a wind power, an electrolysis, and a fuel cell system was conducted with levelized generation cost based on present value methode. As the result, the necessity of renewable energy combined generation system and micro grid composition in the candidated islands was confirmed. Henceforth, the development of an integration technology which connects micro grid to the total power grid will be needed.

  • PDF